Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Bone Joint J ; 100-B(11): 1455-1462, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30418069

RESUMO

AIMS: Osteolysis, secondary to local and systemic physiological effects, is a major challenge in total hip arthroplasty (THA). While osteolytic defects are commonly observed in long-term follow-up, how such lesions alter the distribution of stress is unclear. The aim of this study was to quantitatively describe the biomechanical implication of such lesions by performing subject-specific finite-element (FE) analysis on patients with osteolysis after THA. PATIENTS AND METHODS: A total of 22 hemipelvis FE models were constructed in order to assess the transfer of load in 11 patients with osteolysis around the acetabular component of a THA during slow walking and a fall onto the side. There were nine men and two women. Their mean age was 69 years (55 to 81) at final follow-up. Changes in peak stress values and loads to fracture in the presence of the osteolytic defects were measured. RESULTS: The von Mises stresses were increased in models of those with and those without defects for both loading scenarios. Although some regions showed increases in stress values of up to 100%, there was only a moderate 11.2% increase in von Mises stress in the series as a whole. The site of fracture changed in some models with lowering of the load to fracture by 500 N. The most common site of fracture was the pubic ramus. This was more frequent in models with larger defects. CONCLUSION: We conclude that cancellous defects cause increases in stress within cortical structures. However, these are likely to lead to a modest decrease in the load to fracture if the defect is large (> 20cm3) or if the patient is small with thin cortical structures and low bone mineral density. Cite this article: Bone Joint J 2018;100-B:1455-62.


Assuntos
Acetábulo/fisiopatologia , Artroplastia de Quadril/efeitos adversos , Osteólise/etiologia , Acidentes por Quedas , Acetábulo/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Análise de Elementos Finitos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Osteólise/diagnóstico por imagem , Osteólise/fisiopatologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/fisiopatologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Osso Púbico/lesões , Osso Púbico/fisiopatologia , Estresse Mecânico , Tomografia Computadorizada Espiral/métodos , Caminhada/fisiologia , Suporte de Carga
2.
Bone Joint J ; 99-B(4): 465-474, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28385935

RESUMO

AIMS: The purpose of this study was to determine the sensitivity, specificity and predictive values of previously reported thresholds of proximal translation and sagittal rotation of cementless acetabular components used for revision total hip arthroplasty (THA) at various times during early follow-up. PATIENTS AND METHODS: Migration of cementless acetabular components was measured retrospectively in 84 patients (94 components) using Ein-Bild-Rontgen-Analyse (EBRA-Cup) in two groups of patients. In Group A, components were recorded as not being loose intra-operatively at re-revision THA (52 components/48 patients) and Group B components were recorded to be loose at re-revision (42 components/36 patients). RESULTS: The mean proximal translation and sagittal rotation were significantly higher in Group B than in Group A from three months onwards (p < 0.02). Proximal translation > 1.0 mm within 24 months had a positive predictive value (PPV) of 90% and a specificity of 94%, but a sensitivity of 64%. Proximal translation > 1.0 mm within the first 24 months correctly identified 76 of 94 (81%) of components to be either loose or not loose. However, ten components in Group B (24%) did not migrate proximally above 1.0 mm within the first 60 months. CONCLUSION: The high PPV of EBRA-Cup measurements of proximal translation (90%) shows that this can be used in early follow-up to identify patients at risk of aseptic loosening. The absence of proximal translation within the first 60 months indicates a component is not likely to be loose at re-revision THA although it does not exclude late aseptic loosening as a cause of failure. Cite this article: Bone Joint J 2017;99-B:465-74.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Falha de Prótese/etiologia , Acetábulo/patologia , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Estudos de Casos e Controles , Feminino , Seguimentos , Migração de Corpo Estranho/patologia , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pós-Operatório , Valor Preditivo dos Testes , Desenho de Prótese , Reoperação/efeitos adversos
3.
Bone Joint J ; 99-B(4): 458-464, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28385934

RESUMO

AIMS: This study aimed to determine the diagnostic performance of radiographic criteria to detect aseptic acetabular loosening after revision total hip arthroplasty (THA). Secondary aims were to determine the predictive values of different thresholds of migration and to determine the predictive values of radiolucency criteria. PATIENTS AND METHODS: Acetabular component migration to re-revision was measured retrospectively using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements (Sutherland method) in two groups: Group A, 52 components (48 patients) found not loose at re-revision and Group B, 42 components (36 patients) found loose at re-revision between 1980 and 2015. The presence and extent of radiolucent lines was also assessed. RESULTS: Using EBRA, both proximal translation and sagittal rotation were excellent diagnostic tests for detecting aseptic loosening. The area under the receiver operating characteristic (ROC) curves was 0.94 and 0.93, respectively. The thresholds of 2.5 mm proximal translation or 2° sagittal rotation (EBRA) in combination with radiolucency criteria had a sensitivity of 93% and specificity of 88% to detect aseptic loosening. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of radiolucency criteria were 41%, 100%, 100% and 68% respectively. Manual measurements of both proximal translation and sagittal rotation were very good diagnostic tests. The area under the ROC curve was 0.86 and 0.92 respectively. However, manual measurements had a decreased specificity compared with EBRA. Radiolucency criteria had a poor sensitivity and NPV of 41% and 68% respectively. CONCLUSION: This study shows that EBRA and manual migration measurements can be used as accurate diagnostic tools to detect aseptic loosening of cementless acetabular components used at revision THA. Radiolucency criteria should not be used in isolation to exclude loosening of cementless acetabular components used at revision THA given their poor sensitivity and NPV. Cite this article: Bone Joint J 2017;99-B:458-64.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação/efeitos adversos , Reoperação/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Bone Joint J ; 97-B(8): 1038-45, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26224818

RESUMO

The outcome of 219 revision total hip arthroplasties (THAs) in 98 male and 121 female patients, using 137 long length and 82 standard length cemented collarless double-taper femoral stems in 211 patients, with a mean age of 72 years (30 to 90) and mean follow-up of six years (two to 18) have been described previously. We have extended the follow-up to a mean of 13 years (8 to 20) in this cohort of patients in which the pre-operative bone deficiency Paprosky grading was IIIA or worse in 79% and 73% of femurs with long and standard stems, respectively. For the long stem revision group, survival to re-revision for aseptic loosening at 14 years was 97% (95% confidence interval (CI) 91 to 100) and in patients aged > 70 years, survival was 100%. Two patients (two revisions) were lost to follow-up and 86 patients with 88 revisions had died. Worst-case analysis for survival to re-revision for aseptic loosening at 14 years was 95% (95% CI 89 to 100) and 99% (95% CI 96 to 100) for patients aged > 70 years. One additional long stem was classified as loose radiographically but not revised. For the standard stem revision group, survival to re-revision for aseptic loosening at 14 years was 91% (95% CI 83 to 99). No patients were lost to follow-up and 49 patients with 51 hips had died. No additional stems were classified as loose radiographically. Femoral revision using a cemented collarless double-taper stem, particularly with a long length stem, and in patients aged > 70 years, continues to yield excellent results up to 20 years post-operatively, including in hips with considerable femoral metaphyseal bone loss.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Fêmur/cirurgia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Taxa de Sobrevida , Resultado do Tratamento
5.
Biomed Res Int ; 2015: 758123, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25954757

RESUMO

Modularity at the head-neck junction of the femoral component in THA became popular as a design feature with advantages of decreasing implant inventory and allowing adjustment of leg length, offset, and soft tissue balancing through different head options. The introduction of a new modular interface to femoral stems that were previously monoblock, or nonmodular, comes with the potential for corrosion at the taper junction through mechanically assisted crevice corrosion. The incidence of revision hip arthroplasty is on the rise and along with improved wear properties of polyethylene and ceramic, use of larger femoral head sizes is becoming increasingly popular. Taper corrosion appears to be related to all of its geometric parameters, material combinations, and femoral head size. This review article discusses the pathogenesis, risk factors, clinical assessment, and management of taper corrosion at the head-neck junction.


Assuntos
Artroplastia de Quadril , Cabeça do Fêmur/metabolismo , Cabeça do Fêmur/patologia , Prótese de Quadril/efeitos adversos , Falha de Prótese , Corrosão , Feminino , Humanos , Masculino
6.
Bone Joint J ; 96-B(9): 1155-60, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25183583

RESUMO

Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam.


Assuntos
Acetábulo/diagnóstico por imagem , Luxação Congênita de Quadril/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Osteotomia , Posicionamento do Paciente , Acetábulo/cirurgia , Fluoroscopia , Luxação Congênita de Quadril/cirurgia , Articulação do Quadril/cirurgia , Humanos , Osteotomia/métodos , Decúbito Dorsal , Resultado do Tratamento , Adulto Jovem
7.
Bone Joint J ; 96-B(1): 48-53, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24395310

RESUMO

We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher-Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Músculo Esquelético/inervação , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Nádegas , Eletromiografia/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/irrigação sanguínea , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Falha de Prótese , Reoperação/efeitos adversos , Reoperação/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Acta Biomater ; 8(8): 3104-12, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22554886

RESUMO

Wear particle-induced orthopaedic prosthesis loosening is associated with elevated osteoclast activity. The immunoreceptor tyrosine-based activation motif (ITAM)-related molecules OSCAR, FcRγ, TREM2 and DAP12 are important for osteoclast formation. The aim of this study was to determine if these molecules are involved in peri-implant loosening by investigating their expression in peri-implant tissues obtained at revision of joint replacement components containing polyethylene (PE) wear particles, and in osteoclasts formed in vitro in the presence of PE particles. The results showed that there was a marked and statistically significant increase in protein levels of the ITAM-related molecules in the revision tissues. The levels of OSCAR, FcRγ, TREM2 and DAP12 mRNA in the revision tissues were also increased. In vitro PE particles stimulated osteoclast resorption in the presence of 50 ng ml(-1) receptor activator NFκB (RANKL) and significantly elevated the expression of OSCAR, FcRγ, TREM2 and DAP12 during osteoclast formation. These findings suggest that the ITAM signalling molecules and their co-receptors have a role in pathogenic bone loss associated with implant PE wear.


Assuntos
Prótese Articular , Osteoclastos/citologia , Osteoclastos/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Polietilenos/farmacologia , Próteses e Implantes , Receptores Imunológicos/metabolismo , Idoso , Idoso de 80 Anos ou mais , Dentina/metabolismo , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Fatores de Transcrição NFATC/genética , Fatores de Transcrição NFATC/metabolismo , Osteoartrite/patologia , Osteoclastos/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Receptores Imunológicos/genética , Doadores de Tecidos
9.
J Bone Joint Surg Br ; 93(6): 817-23, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21586783

RESUMO

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured -0.30 mm (-0.73 to 0.02) at two weeks and 0.00 mm (-0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was -0.34 mm (-1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Suporte de Carga , Adulto , Placas Ósseas , Parafusos Ósseos , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Rotação , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Fraturas da Tíbia/reabilitação , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
J Bone Joint Surg Br ; 92(9): 1317-24, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20798456

RESUMO

We dissected 20 cadaver hips in order to investigate the anatomy and excursion of the trochanteric muscles in relation to the posterior approach for total hip replacement. String models of each muscle were created and their excursion measured while the femur was moved between its anatomical position and the dislocated position. The position of the hip was determined by computer navigation. In contrast to previous studies which showed a separate insertion of piriformis and obturator internus, our findings indicated that piriformis inserted onto the superior and anterior margins of the greater trochanter through a conjoint tendon with obturator internus, and had connections to gluteus medius posteriorly. Division of these connections allowed lateral mobilisation of gluteus medius with minimal retraction. Analysis of the excursion of these muscles revealed that positioning the thigh for preparation of the femur through this approach elongated piriformis to a maximum of 182%, obturator internus to 185% and obturator externus to 220% of their resting lengths, which are above the thresholds for rupture of these muscles. Our findings suggested that gluteus medius may be protected from overstretching by release of its connection with the conjoint tendon. In addition, failure to detach piriformis or the obturators during a posterior approach for total hip replacement could potentially produce damage to these muscles because of over-stretching, obturator externus being the most vulnerable.


Assuntos
Articulação do Quadril/anatomia & histologia , Músculo Esquelético/anatomia & histologia , Nádegas/anatomia & histologia , Cadáver , Articulação do Quadril/cirurgia , Humanos
11.
Clin Orthop Relat Res ; 468(12): 3314-21, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20680531

RESUMO

BACKGROUND: Despite stem subsidence being a major complication of femoral impaction bone grafting in cemented revision hip arthroplasty, few studies have distinguished subsidence at the prosthesis-cement interface from that at the cement-bone interface. It is unknown how technique developments intended to improve the procedure influence stability of the stem. QUESTIONS/PURPOSES: We used a sensitive technique to measure subsidence of a cemented polished collarless double-taper stem at each interface after femoral impaction grafting and compared subsidence, radiographic loosening, complications, and reoperations over three series of hips defined by technique developments. PATIENTS AND METHODS: Three series were defined: Series 1 (n = 23, irradiated allograft), Series 2 (n = 12, double-washed, size-profiled graft, nonirradiated bone, long stems as required), and Series 3 (n = 21, modular tamps). Stem subsidence was analyzed with Ein Bild Röntgen Analyse software. Radiographic loosening, complications, and reoperations were also determined. RESULTS: The median subsidence at 12 months for Series 1, 2, and 3 were 2.1, 0.5, and 0.7 mm at the prosthesis-cement interface and 1.3, 0.1, and 0.1 mm at the cement-bone interface. There were two postoperative Vancouver B periprosthetic fractures in Series 1, four hips were revised for loosening in Series 1, and there were no fractures or loosening in Series 2 and 3 at minimum 2 years' followup. There were no surviving hips radiographically classified as possibly or probably loose. CONCLUSIONS: Evolution in techniques of femoral impaction grafting in this study were associated with reduced subsidence of the stem at both the prosthesis-cement interface and cement-bone interface when compared to the original series. Concurrent with reduced stem subsidence was the absence of periprosthetic fracture, radiographic loosening, and complications requiring rerevision.


Assuntos
Artroplastia de Quadril , Transplante Ósseo , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cimentos Ósseos/uso terapêutico , Transplante Ósseo/efeitos adversos , Feminino , Fêmur/diagnóstico por imagem , Fraturas Ósseas/etiologia , Fraturas Ósseas/prevenção & controle , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Prótese de Quadril , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Radiografia , Reoperação , Austrália do Sul , Fatores de Tempo , Transplante Homólogo , Resultado do Tratamento
12.
Clin Anat ; 21(7): 674-82, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18773474

RESUMO

Pelvic external fixators have a high rate of reported complications, most of which relate to pin placement. In this descriptive study, we analyzed the morphology of the ilium in cadaveric specimens and compared these with the measures obtained from normal human pelvic computer tomograph scans, and how these related to each of the three basic configurations of pin positioning for the external fixation of a pelvis: anterosuperior (Slätis type), anteroinferior (supra-acetabular), and subcristal. The irregular shape and size of the iliac wing and the abdominal wall overlying the pin's insertion site could hinder accurate placement of anterosuperior pins. Potential disadvantages of the use of anteroinferior pins was found related to the deep location of the anterior inferior iliac spine, interference with the hip flexion area, risk of hip joint penetration, and the variable obliquity of the ilium. As subcristal pins are positioned between two superficial bony landmarks of the iliac crest, our findings suggest that they are more likely to have a correct placement and avoid complications.


Assuntos
Fixadores Externos , Ílio/anatomia & histologia , Procedimentos Ortopédicos/instrumentação , Ossos Pélvicos/anatomia & histologia , Pinos Ortopédicos , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Procedimentos Ortopédicos/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Tomografia Computadorizada por Raios X
13.
J Bone Joint Surg Br ; 89(7): 879-86, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17673579

RESUMO

We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up. Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain. Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Cimentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/normas , Falha de Prótese , Radiografia , Resultado do Tratamento
14.
J Bone Joint Surg Br ; 83(6): 902-11, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11521937

RESUMO

Extensive osteolysis adjacent to implants is often associated with wear particles of prosthetic material. We have investigated if RANKL, also known as osteoprotegerin ligand, osteoclast differentiation factor or TRANCE, and its natural inhibitor, osteoprotegerin (OPG), may be important in controlling this bone loss. Cells isolated from periprosthetic tissues containing wear particles expressed mRNA encoding for the pro-osteoclastogenic molecules, RANKL, its receptor RANK, monocyte colony-stimulating factor (M-CSF), interleukin (IL)-1beta, tumour necrosis factor (TNF)alpha, IL-6, and soluble IL-6 receptor, as well as OPG. Osteoclasts formed from cells isolated from periprosthetic tissues in the presence and absence of human osteoblastic cells. When osteoclasts formed in the absence of osteoblastic cells, markedly higher levels of RANKL mRNA relative to OPG mRNA were expressed. Particles of prosthetic materials also stimulated human monocytes to express osteoclastogenic molecules in vitro. Our results suggest that ingestion of prosthetic wear particles by macrophages results in expression of osteoclast-differentiating molecules and the stimulation of macrophage differentiation into osteoclasts.


Assuntos
Proteínas de Transporte/metabolismo , Glicoproteínas/metabolismo , Glicoproteínas de Membrana/metabolismo , Osteoclastos/metabolismo , Osteólise/metabolismo , Receptores Citoplasmáticos e Nucleares/metabolismo , Células Cultivadas , Citocinas/metabolismo , Interleucina-6/metabolismo , Fator Estimulador de Colônias de Macrófagos/metabolismo , Macrófagos/metabolismo , Osteoprotegerina , Ligante RANK , RNA Mensageiro/metabolismo , Receptor Ativador de Fator Nuclear kappa-B , Receptores do Fator de Necrose Tumoral , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fator de Necrose Tumoral alfa/análise
15.
J Bone Joint Surg Br ; 82(8): 1182-8, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11132284

RESUMO

We studied the effect of the surface finish of the stem on the transfer of load in the proximal femur in a sheep model of cemented hip arthroplasty. Strain-gauge analysis and corresponding finite-element (FE) analysis were performed to assess the effect of friction and creep at the cement-stem interface. No difference was seen between the matt and polished stems. FE analysis showed that the effects of cement creep and friction at the stem-cement interface on femoral strain were small compared with the effect of inserting a cemented stem.


Assuntos
Cimentos Ósseos , Fêmur/fisiopatologia , Prótese de Quadril/efeitos adversos , Osseointegração , Animais , Fenômenos Biomecânicos , Força Compressiva , Análise de Falha de Equipamento , Análise de Elementos Finitos , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Distribuição Aleatória , Ovinos , Propriedades de Superfície , Análise de Sobrevida , Resistência à Tração , Fatores de Tempo , Suporte de Carga
16.
J Bone Joint Surg Br ; 82(6): 892-900, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10990320

RESUMO

Mononuclear osteoclast precursors are present in the wear-particle-associated macrophage infiltrate found in the membrane surrounding loose implants. These cells are capable of differentiating into osteoclastic bone-resorbing cells when co-cultured with the rat osteoblast-like cell line, UMR 106, in the presence of 1,25(OH)2 vitamin D3. In order to develop an in vitro model of osteoclast differentiation which more closely parallels the cellular microenvironment at the bone-implant interface in situ, we determined whether osteoblast-like human bone-derived cells were capable of supporting the differentiation of osteoclasts from arthroplasty-derived cells and analysed the humoral conditions required for this to occur. Long-term co-culture of arthroplasty-derived cells and human trabecular-bone-derived cells (HBDCs) resulted in the formation of numerous tartrate-resistant-acid-phosphatase (TRAP) and vitronectin-receptor (VNR)-positive multinucleated cells capable of extensive resorption of lacunar bone. The addition of 1,25(OH)2 vitamin D3 was not required for the formation of osteoclasts and bone resorption. During the formation there was release of substantial levels of M-CSF and PGE2. Exogenous PGE2 (10(-8) to 10(-6) M) was found to stimulate strongly the resorption of osteoclastic bone. Our study has shown that HBDCs are capable of supporting the formation of osteoclasts from mononuclear phagocyte precursors present in the periprosthetic tissues surrounding a loose implant. The release of M-CSF and PGE2 by activated cells at the bone-implant interface may be important for the formation of osteoclasts at sites of pathological bone resorption associated with aseptic loosening.


Assuntos
Artroplastia de Substituição/efeitos adversos , Reabsorção Óssea/fisiopatologia , Diferenciação Celular/fisiologia , Técnicas de Cocultura , Macrófagos/fisiologia , Osteoblastos/fisiologia , Osteoclastos/fisiologia , Falha de Prótese , Fosfatase Ácida/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Reabsorção Óssea/etiologia , Linhagem Celular , Técnicas de Cocultura/métodos , Dinoprostona/fisiologia , Feminino , Humanos , Isoenzimas/fisiologia , Fator Estimulador de Colônias de Macrófagos/fisiologia , Masculino , Pessoa de Meia-Idade , Ratos , Receptores de Vitronectina/fisiologia , Fosfatase Ácida Resistente a Tartarato
17.
J Arthroplasty ; 15(5): 654-62, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10960005

RESUMO

Osteoclasts are multinucleated bone-resorbing cells that are formed from precursors that circulate in the monocyte fraction. This study has determined the effect of phagocytosis of metal particles on osteoclast formation and bone resorption in vitro. Human peripheral blood monocytes were cocultured for 21 days with osteoblast-like UMR 106 cells, in the presence of 1,25-dihydroxyvitamin D3, dexamethasone, and human macophage colony-stimulating factor. Cobalt-chrome alloy (CoCr), stainless steel (316L-SS), titanium alloy (TiAlV), and commercially pure titanium (cpTi) particles (size range, 0.5-3.0 microm) and 1.0-microm latex particles were added to the cocultures as a single dose at the beginning of each experiment. All 5 types of particles were readily phagocytosed by the monocytes. After 4 days' exposure to high concentrations of all the metal particles, some cell death was found in the cocultures. After 14 days, a reduction in the number of CD14+ cells was seen in cocultures exposed to high concentrations of metal particles, particularly CoCr and 316L-SS particles. Phagocytosis of latex particles by osteoclast precursors did not affect the ability of these cells to undergo osteoclast differentiation. In contrast, exposure to metal wear particle preparations caused a dose-dependent reduction in the number of vitronectin receptor-positive osteoclastic cells formed and a dose-dependent reduction in the bone resorption produced by these cells. This decrease in resorption was greater after exposure to CoCr and 316L-SS particles compared with TiAlV and cpTi particles. This in vitro cell culture system may provide a useful model to compare the effect of different prosthetic materials on human osteoclast formation and bone resorption.


Assuntos
Reabsorção Óssea/fisiopatologia , Corpos Estranhos/fisiopatologia , Metais/farmacologia , Monócitos/fisiologia , Osteoclastos/fisiologia , Fagocitose , Falha de Prótese , Ligas/farmacologia , Diferenciação Celular , Células Cultivadas , Ligas de Cromo/farmacologia , Humanos , Técnicas In Vitro , Prótese Articular , Metais/metabolismo , Monócitos/citologia , Monócitos/efeitos dos fármacos , Osteoclastos/efeitos dos fármacos , Aço Inoxidável/farmacologia , Titânio/farmacologia
18.
J Orthop Res ; 17(5): 686-94, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10569477

RESUMO

Periprosthetic bone loss is an important contributory factor for aseptic loosening of total joint replacements. It has recently been shown that osteoclast precursor cells are present in the wear particle-associated macrophage infiltrate found in the membrane surrounding loose implants and that these cells are capable of differentiating into osteoclastic bone-resorbing cells. Long-term co-culture of arthroplasty-derived macrophages and the rat osteoblast-like cell line, UMR-106, in the presence of 1,25(OH)2D3 results in the formation of numerous multinucleated cells that are positive for tartrate-resistant acid phosphatase and vitronectin receptor and capable of extensive lacunar bone resorption. The aim of this study was to determine the effect of cytokines/growth factors, known to be present in the arthroplasty membrane, on this process of osteoclast differentiation. During osteoclast formation, increased levels of macrophage colony-stimulating factor, interleukin-6, and to a lesser extent, interleukin-1beta, but not tumour necrosis factor alpha, were detected in the co-culture supernatants. Addition of neutralising antibodies to human interleukin-1beta or tumour necrosis factor alpha to the co-culture system did not inhibit osteoclast formation. In contrast, co-cultures to which neutralising antibodies to human macrophage colony-stimulating factor or interleukin-6 were added contained fewer cells positive for tartrate-resistant acid phosphatase and vitronectin receptor and formed significantly fewer resorption pits. Time-course studies showed that macrophage colony-stimulating factor and interleukin-6 increase osteoclast formation mainly in the early stages of osteoclast differentiation. These results indicate that the release of macrophage colony-stimulating factor and interleukin-6 by activated cells in the arthroplasty membrane is likely to contribute to pathological bone resorption associated with aseptic loosening by stimulating differentiation of mononuclear phagocyte osteoclast precursors into mature bone-resorbing cells.


Assuntos
Reabsorção Óssea/metabolismo , Interleucina-6/metabolismo , Fator Estimulador de Colônias de Macrófagos/metabolismo , Osteoclastos/citologia , Periósteo/citologia , Acetábulo/citologia , Acetábulo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Anticorpos/farmacologia , Artroplastia de Quadril , Reabsorção Óssea/imunologia , Diferenciação Celular/imunologia , Células Cultivadas , Feminino , Fêmur/citologia , Fêmur/cirurgia , Humanos , Interleucina-1/imunologia , Interleucina-1/metabolismo , Interleucina-6/imunologia , Receptores de Lipopolissacarídeos/análise , Fator Estimulador de Colônias de Macrófagos/imunologia , Antígeno de Macrófago 1/análise , Macrófagos/química , Macrófagos/citologia , Macrófagos/imunologia , Masculino , Pessoa de Meia-Idade , Osteoclastos/imunologia , Periósteo/metabolismo , Fator de Necrose Tumoral alfa/imunologia , Fator de Necrose Tumoral alfa/metabolismo
19.
Clin Orthop Relat Res ; (363): 64-72, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10379306

RESUMO

The periacetabular osteotomy is a well established surgical procedure for the preventative treatment of degenerative joint disease caused by symptomatic acetabular dysplasia. Surgeons on several continents use varying surgical approaches to achieve the same effective osteotomy. Individual surgical approaches must provide accurate and adequate exposure for the osteotomy and the reorientation of the acetabular fragment. The aim of the surgical approach for such complex and expansive surgery is to minimize morbidity related to the approach. This article compares experiences among three common approaches including the modified Smith-Petersen, ilioinguinal, and direct anterior approaches and describes the double approach.


Assuntos
Acetábulo/cirurgia , Luxação do Quadril/cirurgia , Osteotomia/métodos , Humanos , Osteoartrite do Quadril/cirurgia , Resultado do Tratamento
20.
J Bone Joint Surg Br ; 80(4): 573-6, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9699814

RESUMO

We have compared prospectively the incidence of loosening of 20 femoral stems with a matt surface with that of 20 polished stems of an otherwise identical tapered, non-modular design of Exeter hip replacement. The stems were inserted using the same technique at operation and radiographs showed no difference in the adequacy of the cement mantle or of fixation. All the patients were reviewed regularly and none was lost to follow-up. After a minimum follow-up of nine years, four matt but no polished stems had been revised for aseptic loosening. Polished stems subsided slightly within the cement mantle early, but did not loosen.


Assuntos
Cimentação , Fêmur , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Acetábulo/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Ligas/química , Artrite Reumatoide/cirurgia , Artroplastia de Quadril , Feminino , Fraturas do Colo Femoral/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Estudos Prospectivos , Radiografia , Reoperação , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...