Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38829298

RESUMO

BACKGROUND: The effect of left ventricular septal myocardial pacing (LVSP) and left bundle branch pacing (LBBP) on ventricular synchrony and left ventricular (LV) hemodynamic status is poorly understood. OBJECTIVES: The aim of this study was to investigate the impact of LVSP and LBBP vs biventricular pacing (BVP) on ventricular electrical synchrony and hemodynamic status in cardiac resynchronization therapy patients. METHODS: In cardiac resynchronization therapy candidates with LV conduction disease, ventricular synchrony was assessed by measuring QRS duration (QRSd) and using ultra-high-frequency electrocardiography. LV electrical dyssynchrony was assessed as the difference between the first activation in leads V1 to V8 to the last from leads V4 to V8. LV hemodynamic status was estimated using invasive systolic blood pressure measurement during multiple transitions between LBBP, LVSP, and BVP. RESULTS: A total of 35 patients with a mean LV ejection fraction of 29% and a mean QRSd of 168 ± 24 ms were included. Thirteen had ischemic cardiomyopathy. QRSd during BVP, LVSP, and LBBP was the same, but LBBP provided shorter LV electrical dyssynchrony than BVP (-10 ms; 95% CI: -16 to -4 ms; P = 0.001); the difference between LVSP and BVP was not significant (-5 ms; 95% CI: -12 to 1 ms; P = 0.10). LBBP was associated with higher systolic blood pressure than BVP (4%; 95% CI: 2% to 5%; P < 0.001), whereas LVSP was not (1%; 95% CI: 0% to 2%; P = 0.10). Hemodynamic differences during LBBP and LVSP vs BVP were more pronounced in nonischemic than ischemic patients. CONCLUSIONS: Ultra-high-frequency electrocardiography allowed the documentation of differences in LV synchrony between LBBP, LVSP, and BVP, which were not observed by measuring QRSd. LVSP provided the same LV synchrony and hemodynamic status as BVP, while LBBP was better than BVP in both.

2.
JACC Clin Electrophysiol ; 10(3): 463-474, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38085214

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) represents a new, nonthermal ablation energy for the ablation of atrial fibrillation (AF). Ablation energies producing thermal injury are associated with an inflammatory response, platelet activation, and coagulation activation. OBJECTIVES: This study aimed to compare the systemic response in patients undergoing pulmonary vein isolation (PVI) using pulsed-field and radiofrequency (RF) energy. METHODS: Patients with AF indicated for PVI were enrolled and randomly assigned to undergo PVI using RF (CARTO Smart Touch, Biosense Webster) or pulsed-field (Farapulse, Boston-Scientific) energy. Markers of myocardial damage (troponin I), inflammation (interleukin-6), coagulation (D-dimers, fibrin monomers, von Willebrand antigen and factor activity), and platelet activation (P-selectin, activated GpIIb/IIIa antigen) were measured before the procedure (T1), after trans-septal puncture (T2), after completing the ablation in the left atrium (T3), and 1 day after the procedure (T4). RESULTS: A total of 65 patients were enrolled in the pulsed-field ablation (n = 33) and RF ablation (n = 32) groups. Both groups were similar in baseline characteristics (age 60.5 ± 12.7 years vs 64.0 ± 10.7 years; paroxysmal AF: 60.6% vs 62.5% patients). Procedural and left atrial dwelling times were substantially shorter in the PFA group (55:09 ± 11:57 min vs 151:19 ± 41:25 min; P < 0.001; 36:00 ± 8:05 min vs 115:58 ± 36:49 min; P < 0.001). Peak troponin release was substantially higher in the PFA group (10,102 ng/L [IQR: 8,272-14,207 ng/L] vs 1,006 ng/L [IQR: 603-1,433ng/L]). Both procedures were associated with similar extents (>50%) of platelet and coagulation activation. The proinflammatory response 24 h after the procedure was slightly but nonsignificantly higher in the RF group. CONCLUSIONS: Despite 10 times more myocardial damage, pulsed-field ablation was associated with a similar degree of platelet/coagulation activation, and slightly lower inflammatory response. (The Effect of Pulsed-Field and Radiofrequency Ablation on Platelet, Coagulation and Inflammation; NCT05603637).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Inflamação , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
3.
Catheter Cardiovasc Interv ; 102(7): 1331-1340, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37855202

RESUMO

BACKGROUND: The presented study investigates the application of bi-arterial 3D printed models to guide transseptal puncture (TSP) in left atrial appendage closure (LAAC). AIMS: The objectives are to (1) test the feasibility of 3D printing (3DP) for TSP guidance, (2) analyse the distribution of the optimal TSP locations, and (3) define a CT-derived 2D parameter suitable for predicting the optimal TSP locations. METHODS: Preprocedural planning included multiplanar CT reconstruction, 3D segmentation, and 3DP. TSP was preprocedurally simulated in vitro at six defined sites. Based on the position of the sheath, TSP sites were classified as optimal, suboptimal, or nonoptimal. The aim was to target the TSP in the recommended position during the procedure. Procedure progress was assessed post hoc by the operator. RESULTS: Of 68 screened patients, 60 patients in five centers (mean age of 74.68 ± 7.64 years, 71.66% males) were prospectively analyzed (3DP failed in one case, and seven patients did not finally undergo the procedure). In 55 patients (91.66%), TSP was performed in the optimal location as recommended by the 3DP. The optimal locations for TSP were postero-inferior in 45.3%, mid-inferior in 45.3%, and antero-inferior in 37.7%, with a mean number of optimal segments of 1.34 ± 0.51 per patient. When the optimal TSP location was achieved, the procedure was considered difficult in only two (3.6%) patients (but in both due to complicated LAA anatomy). Comparing anterior versus posterior TSP in 2D CCT, two parameters differed significantly: (1) the angle supplementary to the LAA ostium and the interatrial septum angle (160.83° ± 9.42° vs. 146.49° ± 8.67°; p = 0.001), and (2) the angle between the LAA ostium and the mitral annulus (95.02° ± 3.73° vs. 107.38° ± 6.76°; p < 0.001), both in the sagittal plane. CONCLUSIONS: In vitro TSP simulation accurately determined the optimal TSP locations for LAAC and facilitated the procedure. More than one-third of the optimal TSP sites were anterior.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Punções/métodos
4.
J Cardiovasc Electrophysiol ; 34(9): 1885-1895, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37529864

RESUMO

INTRODUCTION: Observational studies have shown low bleeding rates in patients with atrial fibrillation (AF) treated by left atrial appendage closure (LAAC); however, data from randomized studies are lacking. This study compared bleeding events among patients with AF treated by LAAC and nonvitamin K anticoagulants (NOAC). METHODS: The Prague-17 trial was a prospective, multicenter, randomized trial that compared LAAC to NOAC in high-risk AF patients. The primary endpoint was a composite of a cardioembolic event, cardiovascular death, and major and clinically relevant nonmajor bleeding (CRNMB) defined according to the International Society on Thrombosis and Hemostasis (ISTH). RESULTS: The trial enrolled 402 patients (201 per arm), and the median follow-up was 3.5 (IQR 2.6-4.2) years. Bleeding occurred in 24 patients (29 events) and 32 patients (40 events) in the LAAC and NOAC groups, respectively. Six of the LAAC bleeding events were procedure/device-related. In the primary intention-to-treat analysis, LAAC was associated with similar rates of ISTH major or CRNMB (sHR 0.75, 95% CI 0.44-1.27, p = 0.28), but with a reduction in nonprocedural major or CRNMB (sHR 0.55, 95% CI 0.31-0.97, p = 0.039). This reduction for nonprocedural bleeding with LAAC was mainly driven by a reduced rate of CRNMB (sHR for major bleeding 0.69, 95% CI 0.34-1.39, p = .30; sHR for CRNMB 0.43, 95% CI 0.18-1.03, p = 0.059). History of bleeding was a predictor of bleeding during follow-up. Gastrointestinal bleeding was the most common bleeding site in both groups. CONCLUSION: During the 4-year follow-up, LAAC was associated with less nonprocedural bleeding. The reduction is mainly driven by a decrease in CRNMB.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Anticoagulantes/efeitos adversos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico
5.
Eur Heart J Suppl ; 25(Suppl E): E25-E32, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37234230

RESUMO

The association between antithrombotics (ATs) and the risk of gastrointestinal bleeding is well known; however, data regarding the influence of ATs on outcomes are scarce. The goals of this study are: (i) to assess the impact of prior AT therapy on in-hospital and 6-month outcomes and (ii) to determine the re-initiation rate of the ATs after a bleeding event. All patients with upper gastrointestinal bleeding (UGB) who underwent urgent gastroscopy in three centres from 1 January 2019 to 31 December 2019 were retrospectively analysed. Propensity score matching (PSM) was used. Among 333 patients [60% males, mean age 69.2 (±17.3) years], 44% were receiving ATs. In multivariate logistic regression, no association between AT treatment and worse in-hospital outcomes was observed. Development of haemorrhagic shock led to worse survival [odds ratio (OR) 4.4, 95% confidence interval (CI) 1.9-10.2, P < 0.001; after PSM: OR 5.3, 95% CI 1.8-15.7, P = 0.003]. During 6-months follow-up, higher age (OR 1.0, 95% CI 1.0-1.1, P = 0.002), higher comorbidity (OR 1.4, 95% CI 1.2-1.7, P < 0.001), a history of cancer (OR 3.6, 95% CI 1.6-8.1, P < 0.001) and a history of liver cirrhosis (OR 2.2, 95% CI 1.0-4.4, P = 0.029) were associated with higher mortality. After a bleeding episode, ATs were adequately re-initiated in 73.8%. Previous AT therapy does not worsen in-hospital outcomes in after UGB. Development of haemorrhagic shock predicted poor prognosis. Higher 6-month mortality was observed in older patients, patients with more comorbidities, with liver cirrhosis and cancer.

6.
J Atr Fibrillation ; 13(6): 20200449, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950349

RESUMO

BACKGROUND: Left atrial appendage (LAA) closure (LAAC) is accompanied by a high risk of complications. Due to the complex anatomy of the LAA and the oval-shaped ostium, the proper sizing of the device is often difficult. PURPOSE: To assess individualized fluoroscopy viewing angles using pre-procedural CT analysis and to compare the results of landing zone measurements obtained from CT, transesophageal echocardiography (TEE), intracardiac echocardiography (ICE), and fluoroscopy. METHODS: Patients with indications for LAAC were enrolled. Cardiac CT and TEE were done before the procedure; ICE and fluoroscopy measurements were done peri-procedurally. Multiplanar reconstruction of CT images, using FluoroCT software, was done, and optimal "personalized" viewing angles for fluoroscopy were determined. Moreover, a mean (using multiplanar CT reconstruction, derived from the LAA perimetr) amd maximum (using all four imaging modalitities) landing zone (LZ) of the LAA were masured. RESULTS: Twenty-five patients were analyzed. Despite significant correlation between LZs obtained from different imaging modalities, the values of LZs differed significantly; the mean LZ diameter on CT was 20.60 ± 3.42 mm, the maximum diameters were 21.99 ± 4.03 mm (CT), 18.72 ± 2.44 mm (TEE), 18.20 ± 2.68 mm (ICE), and 17.76 ± 3.24 mm (fluoroscopy). The mean CT diameter matched with the final device selection in 92% patients, while fluoroscopy or TEE maximum diameters in only 72% patients. Optimal viewing angles differed significantly from the fluoroscopy projections usually recommended by the manufacturer in 3 patients. CONCLUSIONS: CT provides the best measurement of the LZ and the best prediction of the optimum fluoroscopy projections for the implantation procedure.

7.
J Cardiovasc Electrophysiol ; 32(10): 2645-2654, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34402135

RESUMO

INTRODUCTION: The randomized PRAGUE-17 trial demonstrated noninferiority of left atrial appendage closure (LAAC) to non-vitamin K anticoagulants (NOACs) for the prevention of major cardiovascular or cerebrovascular events. However, the left atrial appendage is an important source of natriuretic peptides and plays a role in left atrial reservoir function. Changes of heart failure (HF) biomarkers after LAAC compared to NOAC has not been studied. The aim of the study was to compare the changes in concentrations of HF biomarkers between LAAC and NOAC patients. METHODS: Of 402 patients randomized in the PRAGUE-17 trial, biomarkers were analyzed in 144 patients (73 in the NOAC and 71 in the LAAC group). Both groups had similar baseline characteristics. Serum concentration of NT-proBNP, NT-proANP, Galectin-3, and GDF-15 were measured at baseline (before the procedure in the LAAC group), at the 6-month (and at 24-month for NT-proBNP) follow-up timepoint. RESULTS: There were no significant differences in baseline, 6 month, and delta (δ = baseline - 6 month) concentrations of NT-proANP between the groups (NOAC: baseline 2.6 [0.5; 4.9], 6-month 3.1 [1.8; 4.8], p = .068; LAAC: baseline 3.3 [1.1; 4.6], 6-month 2.6 [0.9; 5.3], p = .51; p value for δ in concentrations between groups = 0.42). Similarly, there were no significant differences in baseline, 6, 24 months, and delta concentrations of NT-proBNP between the groups (NOAC: baseline 461.0 [113.5; 1342.0], 6 month 440.0 [120.5; 1291.5], 24 month 798 [274; 2236], p = .39; LAAC: baseline 421.0 [100.0; 1320.0], 6 month 601.0 [145.0; 1230.0], 24 month 855 [410; 1367], p = .28; p value for δ in concentrations between groups = 0.73 at 6 months, and 0.58 at 24 months). Finally, no significant differences were present in baseline, 6 month, and δ concentrations of Galectin-3 and GDF-15 between the two groups. CONCLUSION: LAAC did not significantly influence the levels of HF biomarkers 6 months after the procedure.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Biomarcadores , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos
8.
Vnitr Lek ; 66(6): 1-9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33380146

RESUMO

Stroke is one of the most severe complications of atrial fibrillation. Oral anticoagulation is the first choice therapy in prevention of cardiac embolic events. Particularly in patients with the history of serious bleeding, oral anticoagulation may be contraindicated. Percutaneous left atrial appendage closure represents an alternative in prophylaxis of cardiac embolic events. This review article describes physiology and pathophysiology of the left auricle, the most frequently used devices and their indications and scientific rationale.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Anticoagulantes , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Hemorragia , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS