Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Eur Spine J ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38937348

RESUMO

PURPOSE: To investigate efficacy of 3-month teriparatide(TPD) and compare this treatment with vertebroplasty in terms of clinical and radiographic outcomes after osteoporotic vertebral compression fractures (OVCFs). METHODS: This is a retrospective matched cohort study. Patients who received conservative treatment with at least 3-month TPD treatment for acute OVCF with at least 6 months follow-up were included. Each enrolled TPD case was matched with 2 vertebroplasty cases using age and gender. 30 TPD cases and 60 vertebroplasty cases were enrolled. Patient-reported pain scores were obtained at diagnosis and 1, 3, 6 months after diagnosis. Radiographic parameters including middle body height, posterior body height, wedge angle and kyphotic angle were measured at diagnosis and 6 months after diagnosis. Fracture non-union and subsequent vertebral fracture were evaluated. RESULTS: TPD treatment showed inferior pain relief to vertebroplasty group at 1 month, but did not show difference at 3 and 6 months after diagnosis. In TPD cases, progression of vertebral body collapse was noted in terms of middle body height and wedge angle at final follow up. Instead, both middle body height and wedge angle increased significantly after operation in the vertebroplasty group. Fracture non-union was confirmed via MRI and 4 TPD patients were diagnosed with non-union (4/30, 13.3%). Subsequent compression fracture within 6 months was significant higher in vertebroplasty group (12/60, 20%) than in TPD group (1/30, 3.3%). CONCLUSION: In acute OVCFs, 3-month TPD treatment alone showed comparable pain improvement and less subsequent spine fracture than vertebroplasty.

2.
JBMR Plus ; 8(5): ziae031, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606146

RESUMO

Nonunion resulting from early bone resorption is common after bone transplantation surgery. In these patients, instability or osteoporosis causes hyperactive catabolism relative to anabolism, leading to graft resorption instead of fusion. Systemic zoledronate administration inhibits osteoclastogenesis and is widely used to prevent osteoporosis; however, evidence on local zoledronate application is controversial due to osteoblast cytotoxicity, uncontrolled dosing regimens, and local release methods. We investigated the effects of zolendronate on osteoclastogenesis and osteogenesis and explored the corresponding signaling pathways. In vitro cytotoxicity and differentiation of MC3T3E1 cells, rat bone marrow stromal cells (BMSCs) and preosteoclasts (RAW264.7 cells) were evaluated with different zolendronate concentrations. In vivo bone regeneration ability was tested by transplanting different concentrations of zolendronate with ß-tricalcium phosphate (TCP) bone substitute into rat femoral critical-sized bone defects. In vitro, zolendronate concentrations below 2.5 × 10-7 M did not compromise viability in the three cell lines and did not promote osteogenic differentiation in MC3T3E1 cells and BMSCs. In RAW264.7 cells, zoledronate inhibited extracellular regulated protein kinases and c-Jun n-terminal kinase signaling, downregulating c-Fos and NFATc1 expression, with reduced expression of fusion-related dendritic cell­specific transmembrane protein and osteoclast-specific Ctsk and tartrate-resistant acid phosphatase (. In vivo, histological staining revealed increased osteoid formation and neovascularization and reduced fibrotic tissue with 500 µM and 2000 µM zolendronate. More osteoclasts were found in the normal saline group after 6 weeks, and sequential osteoclast formation occurred after zoledronate treatment, indicating inhibition of bone resorption during early callus formation without inhibition of late-stage bone remodeling. In vivo, soaking ß-TCP artificial bone with 500 µM or 2000 µM zoledronate is a promising approach for bone regeneration, with potential applications in bone transplantation.

3.
Spine J ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38499068

RESUMO

BACKGROUND CONTEXT: Long-segment pedicle screw instrumentation is widely used to treat complex spinal disorders. Rods are routinely precontoured to maximize assistance on the correcting side of the deformity, but there often exists a residual gap discrepancy between the precontoured rods and screw tulips. No previous research has investigated the diminished pullout strength of the most proximal or distal pedicle screw resulting from a mismatched rod in long-segment pedicle screw instrumentation. PURPOSE: The present study aimed to investigate the decreased pullout force of pedicle screws affected by the gap discrepancy when forcefully engaging a mismatched rod into a tulip in a normal-density porcine spine. STUDY DESIGN: The pedicle screw fixation strength under axial pullout force was compared among three different gap discrepancies between rods and tulips using long porcine spine segments. METHODS: Twelve porcine lumbar vertebrae (L3-L6) were implanted with pedicle screws and rods. Screws on one side had no gap between the tulip and rod (0-mm group), while the most proximal screw on the other side had an intentional gap of 3 mm (3-mm group) or 6 mm (6-mm group). Three hours after forcefully engaging the rod into the tulips at room temperature, the set screws in all specimens were loosened, and each specimen was dissected into individual vertebrae for subsequent pullout testing. RESULTS: The control group exhibited significantly greater pullout strength (1987.68 ± 126.80 N) than the groups from different rod-tulip configurations (p<.05), with significantly greater strength in the 3-mm group (945.62 ± 97.43 N) than the 6-mm group (655.30 ± 194.49 N) (p<.05). Only 47.6% and 33.0% of the pullout strength was retained in the 3-mm and 6-mm groups, respectively, compared to the control group. CONCLUSIONS: Gap discrepancies between rods and tulips can significantly reduce pedicle screw pullout strength, with a correlation between decreased strength and increased gaps. Surgeons should avoid forcefully engaging mismatched rods and consider well-fitted contoured rods in spinal surgery to minimize the risk of screw loosening. CLINICAL SIGNIFICANCE: The gap discrepancy between rod and tulip significantly affected pullout strength, with greater gaps leading to reduced strength. Forcefully engaging mismatched rods into tulips in degenerative spinal surgery should be avoided to minimize the risk of early screw pullout.

4.
Front Bioeng Biotechnol ; 12: 1359883, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38380264

RESUMO

Despite advancements in pedicle screw design and surgical techniques, the standard steps for inserting pedicle screws still need to follow a set of fixed procedures. The first step, known as establishing a pilot hole, also referred to as a pre-drilled hole, is crucial for ensuring screw insertion accuracy. In different surgical approaches, such as minimally invasive or traditional surgery, the method of creating pilot holes varies, resulting in different pilot hole profiles, including variations in size and shape. The aim of this study is to evaluate the biomechanical properties of different pilot hole profiles corresponding to various surgical approaches. Commercially available synthetic L4 vertebrae with a density of 0.16 g/cc were utilized as substitutes for human bone. Four different pilot hole profiles were created using a 3.0 mm cylindrical bone biopsy needle, 3.6 mm cylindrical drill, 3.2-5.0 mm conical drill, and 3.2-5.0 mm conical curette for simulating various minimally invasive and traditional spinal surgeries. Two frequently employed screw shapes, namely, cylindrical and conical, were selected. Following specimen preparation, screw pullout tests were performed using a material test machine, and statistical analysis was applied to compare the mean maximal pullout strength of each configuration. Conical and cylindrical screws in these four pilot hole configurations showed similar trends, with the mean maximal pullout strength ranking from high to low as follows: 3.0 mm cylindrical biopsy needle, 3.6 mm cylindrical drill bit, 3.2-5.0 mm conical curette, and 3.2-5.0 mm conical drill bit. Conical screws generally exhibited a greater mean maximal pullout strength than cylindrical screws in three of the four different pilot hole configurations. In the groups with conical pilot holes, created with a 3.2-5.0 mm drill bit and 3.2-5.0 mm curette, both conical screws exhibited a greater mean maximal pullout strength than did cylindrical screws. The strength of this study lies in its comprehensive comparison of the impact of various pilot hole profiles commonly used in clinical procedures on screw fixation stability, a topic rarely reported in the literature. Our results demonstrated that pilot holes created for minimally invasive surgery using image-guided techniques exhibit superior pullout strength compared to those utilized in traditional surgery. Therefore, we recommend prioritizing minimally invasive surgery when screw implantation is anticipated to be difficult or there is a specific need for stronger screw fixation. When opting for traditional surgery, image-guided methods may help establish smaller pilot holes and increase screw fixation strength.

6.
Front Bioeng Biotechnol ; 11: 1182265, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324423

RESUMO

Ball-and-socket designs of cervical total disc replacement (TDR) have been popular in recent years despite the disadvantages of polyethylene wear, heterotrophic ossification, increased facet contact force, and implant subsidence. In this study, a non-articulating, additively manufactured hybrid TDR with an ultra-high molecular weight polyethylene core and polycarbonate urethane (PCU) fiber jacket, was designed to mimic the motion of normal discs. A finite element (FE) study was conducted to optimize the lattice structure and assess the biomechanical performance of this new generation TDR with an intact disc and a commercial ball-and-socket Baguera®C TDR (Spineart SA, Geneva, Switzerland) on an intact C5-6 cervical spinal model. The lattice structure of the PCU fiber was constructed using the Tesseract or the Cross structures from the IntraLattice model in the Rhino software (McNeel North America, Seattle, WA) to create the hybrid I and hybrid II groups, respectively. The circumferential area of the PCU fiber was divided into three regions (anterior, lateral and posterior), and the cellular structures were adjusted. Optimal cellular distributions and structures were A2L5P2 in the hybrid I and A2L7P3 in the hybrid II groups. All but one of the maximum von Mises stresses were within the yield strength of the PCU material. The range of motions, facet joint stress, C6 vertebral superior endplate stress and path of instantaneous center of rotation of the hybrid I and II groups were closer to those of the intact group than those of the Baguera®C group under 100 N follower load and pure moment of 1.5 Nm in four different planar motions. Restoration of normal cervical spinal kinematics and prevention of implant subsidence could be observed from the FE analysis results. Superior stress distribution in the PCU fiber and core in the hybrid II group revealed that the Cross lattice structure of a PCU fiber jacket could be a choice for a next-generation TDR. This promising outcome suggests the feasibility of implanting an additively manufactured multi-material artificial disc that allows for better physiological motion than the current ball-and-socket design.

7.
Front Bioeng Biotechnol ; 11: 1151627, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37214307

RESUMO

Intraoperative pedicle screw depth adjustment after initial insertion, including both forward and backward adjustments, is sometimes necessary to facilitate rod application and ensure that the screw is in the correct position, which is determined by intraoperative fluoroscopy. Adjusting the screw with forward turns has no negative influence on the screw fixation stability; however, screw turnback may weaken the fixation stability. The aim of this study is to evaluate the biomechanical properties of screw turnback and demonstrate the reduction in the fixation stability after the screw is turned 360° from its full insertion position. Commercially available synthetic closed-cell polyurethane foams with three different densities simulating various degrees of bone density were utilized as substitutes for human bone. Two different screw shapes (cylindrical and conical) together with two different pilot hole profiles (cylindrical and conical) were tested. Following specimen preparation, screw pullout tests were conducted using a material test machine. The mean maximal pullout strength between full insertion and 360-degree turnback from full insertion in each setting was statistically analyzed. The mean maximal pullout strength after 360-degree turnback from full insertion was generally lower than that at full insertion. The reduced mean maximal pullout strength after turnback increased with decreasing bone density. Conical screws had significantly lower pullout strength after 360-degree turnback than cylindrical screws. The mean maximal pullout strength was reduced by up to approximately 27% after 360-degree turnback when using a conical screw in a low bone density specimen. Additionally, specimens treated with a conical pilot hole presented a less reduction in pullout strength after screw turnback as compared to those with a cylindrical pilot hole. The strength of our study was that we systematically investigated the effects of various bone densities and screw shapes on screw stability after turnback, which has rarely been reported in the literature. Our study suggests that pedicle screw turnback after full insertion should be reduced in spinal surgeries, particularly procedures that use conical screws in osteoporotic bone. Pedicle screw secured with a conical pilot hole might be beneficial for screw adjustment.

8.
Sci Rep ; 13(1): 454, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624133

RESUMO

Although an anterior approach with anterior lateral screw fixation has been developed for stabilizing the thoracolumbar spine clinically, screw loosening still occurs. In this novel in vitro study, we attempted to elucidate the optimal screw position in the lateral lumbar vertebra and the effect of bicortical fixation. A total of 72 fresh-frozen lumbar vertebrae from L1-6 were harvested from 12 mature pigs and randomly assigned to two modalities: bicortical fixation (n = 36) and unicortical fixation (n = 36). Six groups of screw positions in the lateral vertebral body in each modality were designated as central-anterior, central-middle, central-posterior, lower-anterior, lower-middle, and lower- posterior; 6 specimens were used in each group. The correlations between screw fixation modalities, screw positions and axial pullout strength were analyzed. An appropriate screw trajectory and insertional depth were confirmed using axial and sagittal X-ray imaging prior to pullout testing. In both bicortical and unicortical fixation modalities, the screw pullout force was significantly higher in the posterior or middle position than in the anterior position (p < 0.05), and there was no significant differences between the central and lower positions. The maximal pullout forces from the same screw positions in unicortical fixation modalities were all significantly lower, decreases that ranged from 32.7 to 74%, than those in bicortical fixation modalities. Our study using porcine vertebrae showed that screws in the middle or posterior position of the lateral vertebral body had a higher pullout performance than those in the anterior position. Posteriorly positioned lateral vertebral screws with unicortical fixation provided better stability than anteriorly positioned screws with bicortical fixation.


Assuntos
Parafusos Ósseos , Fusão Vertebral , Suínos , Animais , Cadáver , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Radiografia , Fenômenos Biomecânicos
9.
Global Spine J ; 13(1): 25-32, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33511875

RESUMO

STUDY DESIGN: Biomechanical study. OBJECTIVE: Cross-links are a type of common clinical spinal instrumentation. However, the effects of the position and number of cross-links have never been investigated in long-segment spinal fixation, and the variables have not been optimized. We conducted an in vitro biomechanical study by using a porcine long-segment spinal model with 5 different crosslink configurations to determine the optimal construct for clinical practice. METHODS: Five modalities with paired segmental screws from T15-L5 were tested in 20 porcine spines. The spines without cross-links composed the control group, Group A; those with a single cross-link from L2-3 composed Group B; those with 2 cross-links from L1-2 and L3-4 composed Group C; those with 2 cross-links from T15-L1 and L4-5 composed Group D; and those with 3 cross-links from T15-L1, L2-3 and L4-5 composed Group E. Spinal stiffnesses in flexion, extension, lateral bending, and axial rotation were compared among 5 different cross-link configurations in 5-level porcine spinal units. RESULTS: Flexional, extensional and lateral bending stiffnesses did not significantly change with an increasing number of cross-links or positions in the construct. Axial stiffness was significantly increased with 2 cross-links compared to one (P < 0.05) and with placement more distant from the center of the long spinal fixation construct (P < 0.05). CONCLUSIONS: Two cross-links individually placed proximal and distal from the center of a construct is an optimal and efficient configuration to achieve biomechanical stability in non-rigid lumbar spines undergoing long-level fixation.

10.
Spine J ; 23(2): 315-324, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36058516

RESUMO

BACKGROUND CONTEXT: Pedicle screw-rod assembly procedures following pedicle screw insertion include contouring and placing rods into screw tulips, introducing set screws into the tulip along the screw thread, applying a counter-torque holder and tightening all the set screws clockwise. Even if an appropriate pedicle screw is implanted, screw dislodgement after tightening of the tulip and set screw is not uncommon. Pedicle wall violation resulting from excessive rotational force due to inadequate use of a counter-torque holder might be the reason. However, the strain change in the pedicle during tulip-set screw tightening and the role of counter-torque have never been investigated. PURPOSE: This study determined differences in the strain change in the outer and inner pedicle walls during tulip-set screw tightening; additionally, the influence of counter-torque on pedicle wall violation was elucidated. STUDY DESIGN: A controlled biomechanical study; the strain values of outer and inner pedicle walls in cadaveric porcine L4-L5 vertebrae during tulip-set screw tightening with or without a counter-torque holder were measured. METHODS: Twelve L4-L5 fresh-frozen porcine lumbar vertebrae were implanted with screw-rod constructs; the set screw was randomly locked into the tulip in the right L5, right L4, left L5 and left L4 testing groups. The maximal values from eight strain gauges (P-R-O: outer cortex of right pedicle in proximal vertebra; P-R-I: inner cortex of right pedicle in proximal vertebra; D-R-O: outer cortex of right pedicle in distal vertebra; D-R-I: inner cortex of right pedicle in distal vertebra; P-L-O: outer cortex of left pedicle in proximal vertebra; P-L-I: inner cortex of left pedicle in proximal vertebra; D-L-O: outer cortex of left pedicle in distal vertebra; D-L-I: outer cortex of left pedicle in proximal vertebra) for each specimen during tightening to 12 Nm were measured. RESULTS: The maximal strain values of the ipsilateral strain gauges in all testing groups were almost significantly higher when a counter-torque holder was not used than when one was used. The strain values in the adjacent pedicle of specimens without a counter-torque holder were significantly increased: P-R-O and P-R-I in the right L5 group; D-R-I in the right L4 group; P-L-I and P-L-O in the left L5 group; D-L-O and D-L-I in the left L4 group. CONCLUSIONS: The constraint effect of counter-torque during tulip-set screw tightening is necessary. Clockwise rotational force with a fragile lateral pedicle wall suggests that caution is required when using a counter-torque holder to tighten the right L5 and left L4 constructs. CLINICAL SIGNIFICANCE: A counter-torque holder is important during tulip-set screw tightening; improper use may lead to adjacent pedicle wall violation, sequentially resulting in pedicle screw loosening.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Animais , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Suínos , Torque
11.
Front Bioeng Biotechnol ; 10: 1054738, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36568298

RESUMO

Three key factors are responsible for the biomechanical performance of pedicle screw fixation: screw mechanical characteristics, bone quality and insertion techniques. To the best of the authors' knowledge, no study has directly compared the biomechanical performance among three trajectories, i.e., the traditional trajectory (TT), modified trajectory (MT) and cortical bone trajectory (CBT), in a porcine model. This study compared the pullout strength and insertion torque of three trajectory methods in single vertebrae, the pullout strength and fixation stiffness including flexion, extension, and lateral bending in a one-level instrumented functional spinal unit (FSU) that mimics the in vivo configuration were clarified. A total of 18 single vertebrae and 18 FSUs were randomly assigned into three screw insertion methods (n = 6 in each trajectory group). In the TT group, the screw converged from its entry point, passed completely inside the pedicle, was parallel to the superior endplate, was located in the superior third of the vertebral body and reached to at least the anterior third of the vertebral body. In the MT group, the convergent angle was similar to that of the TT method but directed caudally to the anterior inferior margin of the vertebral body. The results of insertion torque and pullout strength in single vertebrae were analyzed; in addition, the stiffness and pullout strength in the one-level FSU were also investigated. This study demonstrated that, in single vertebrae, the insertion torque was significantly higher in CBT groups than in TT and MT groups (p < 0.05). The maximal pullout strength was significantly higher in MT groups than in TT and CBT groups (p < 0.05). There was no significant difference in stiffness in the three motions among all groups. The maximal pullout strength in FSUs of MT and CBT groups were significantly higher than the TT groups (p < 0.05). We concluded that either MT or CBT provides better biomechanical performance than TT in single vertebrae or FSUs. The lack of significance of stiffness in FSUs among three methods suggested that MT or CBT could be a reasonable alternative to TT if the traditional trajectory was not feasible.

12.
Biomedicines ; 10(7)2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-35884964

RESUMO

Background: Postoperative immunosuppression is associated with blood loss and surgical trauma during surgery and subsequently predisposes patients to increased morbidity. Spine endoscopic surgery has been accepted as an effective surgical technique with less surgical trauma and less blood loss for the complication of infectious spondylodiscitis. Therefore, the aim of this study was to investigate whether PEIDF could reduce the morbidity rates for patients with infectious spondylodiscitis. Methods: We launched a retrospective cohort study on the comparison of the perioperative prognosis between PEIDF and conventional open surgery for single-level lumbar infectious spondylodiscitis in patients with poor physical health (ASA ≥ 4) from 2014 to 2019. Results: Forty-four patients were included in this study. Fifteen of them underwent PEIDF, and the rest of the 29 patients were treated with open surgery. Less surgical blood loss (p < 0.001) and intraoperative transfusions (p < 0.001) with a better decline of CRP (p = 0.017) were statistically significant in patients receiving PEIDF. Patients undergoing conventional open surgery encountered more postoperative sepsis (p = 0.030), a higher qSOFA score (p = 0.044), and prolonged-time for CRP normalization (p = 0.001). Conclusions: PEIDF minimizes a poor postoperative outcome due to less surgical trauma, intraoperative blood loss, and the need for a blood transfusion.

13.
J Mech Behav Biomed Mater ; 134: 105366, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35870229

RESUMO

Pedicle screw fixation is one of the most common procedures used in spinal fusion surgery. The screw loosening is a major concern, which may be caused by broken pedicles. In vitro pullout tests or insertion torque are the main approaches for assessing the stability of the screw; however, direct evidence was lacking for clinical human spines. Here, we aim to provide a model that can predict the pullout strengths of pedicle screws in various pedicle conditions from X-ray images. A weighted embedded bone volume (EBV) model is proposed for pullout strengths prediction by considering the bone heterogeneity and confinement of the screw. We showed that the pullout strength is proportional to the EBV for homogeneous bone and the weighted EBV for layered composite bone. The proposed weighted EBV model is validated with in vitro Sawbones® pullout experiments. The results show that the model has better accuracy than the simple EBV model, with a coefficient of determination of 0.94. The proposed weighted EBV model can help assess the stability of a pedicle screw in a broken pedicle by simply examining 2D X-ray images.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Humanos , Fusão Vertebral/métodos , Torque , Raios X
14.
J Neurosurg Spine ; : 1-9, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35561693

RESUMO

OBJECTIVE: Decreased bone mineral density as measured by dual-energy x-ray absorptiometry (DEXA) has been reported to be associated with cage subsidence following transforaminal lumbar interbody fusion (TLIF). However, DEXA is not often available or routinely performed before surgery. A novel MRI-based vertebral bone quality (VBQ) score has been developed and reported to be correlated with DEXA T-scores. The authors investigated the ability of the VBQ score to predict cage subsidence and other risk factors associated with this complication. METHODS: In this retrospective study, the authors reviewed the records of patients who had undergone single-level TLIF from March 2014 to October 2015 and had a follow-up of more than 2 years. Cage subsidence was measured as postoperative disc height loss and was graded according to the system proposed by Marchi et al. The MRI-based VBQ score was measured on T1-weighted images. Univariable analysis and multivariable binary logistic regression analysis were performed. Ad hoc analysis with receiver operating characteristic curve analysis was performed to assess the predictive ability of the significant continuous variables. Additional analyses were used to determine the correlations between the VBQ score and T-scores and between the significant continuous variables and the amount of cage subsidence. RESULTS: Among 242 patients eligible for study inclusion, 111 (45.87%) had cage subsidence after the index operation. Multivariable logistic regression analyses demonstrated that an increased VBQ score (OR 14.615 ± 0.377, p < 0.001), decreased depth ratio (OR 0.011 ± 1.796, p = 0.013), and the use of kidney-shaped cages instead of bullet-shaped cages (OR 2.766 ± 0.358, p = 0.008) were associated with increased cage subsidence. The VBQ score was shown to significantly predict cage subsidence with an accuracy of 85.6%. The VBQ score was found to be moderately correlated with DEXA T-scores of the total hip (r = -0.540, p < 0.001) and the lumbar spine (r = -0.546, p < 0.001). The amount of cage subsidence was moderately correlated with the VBQ score (r = 0.512, p < 0.001). CONCLUSIONS: Increased VBQ scores, posteriorly placed cages, and kidney-shaped cages were risk factors for cage subsidence. The VBQ score was shown to be a good predictor of cage subsidence, was moderately correlated with DEXA T-scores for the total hip and lumbar spine, and also had a moderate correlation with the amount of cage subsidence.

15.
Sci Rep ; 12(1): 2739, 2022 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35177724

RESUMO

Polymethylmethacrylate (PMMA) has been applied clinically and biomechanically repair loose pedicle screws. Controversies have arisen over data due to uncontrolled cement properties, various locations and sizes of fenestrated holes in repair screws, irregular holes and different bone densities of specimens. In this study, the pullout strength was compared for two techniques, the modified technique to use PMMA to augment a threaded hole and the traditional technique with retrograde injection of a PMMA filling, for standard loose screws in porcine vertebrae. Both techniques provided statistically significant results for sufficiently randomized specimens and experimental procedures. The difference in the pullout strength between conical and cylindrical screws for the aforementioned cement augmentation techniques was also investigated. Twenty-four single-level fresh-frozen lumbar vertebrae from L1 to L6 were harvested from four mature pigs. A total of 0.8 ml of PMMA was retrograde injected into screw holes with a 5.5 mm diameter, followed by insertion of a 5.0 mm diameter repair screw in the traditional group (n = 12). A stiff threaded PMMA hole was created with a 4.5 mm tapping screw before insertion of repair screws in the modified group (n = 12). Two screw geometries were randomly assigned as cylindrical (n = 6) and conical (n = 6) in each group. The correlations between filling techniques, screw geometries and axial pullout strength were analyzed. An appropriate screw trajectory and insertion depth were confirmed using X-ray imaging prior to pullout testing in both groups. For a given screw geometry (cylindrical or conical), the pullout force of the modified group was significantly higher than that of the traditional group. There was no significant difference in the pullout force between the screw geometries for a given filling technique. The cement augmentation technique is far more influential than the screw outer geometry. The modified PMMA technique created a greater anchor force than the traditional method and could be an alternative for revision of pedicle screw loosening.


Assuntos
Cimentos Ósseos/farmacologia , Vértebras Lombares/cirurgia , Parafusos Pediculares , Animais , Suínos
16.
Sci Technol Adv Mater ; 23(1): 1-16, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35023999

RESUMO

The complex process of wound healing depends on the coordinated interaction between various immunological and biological systems, which can be aided by technology. This present review provides a broad overview of the medical applications of piezoelectric and triboelectric nanogenerators, focusing on their role in the development of wound healing technology. Based on the finding that the damaged epithelial layer of the wound generates an endogenous bioelectric field to regulate the wound healing process, development of technological device for providing an exogenous electric field has therefore been paid attention. Authors of this review focus on the design and application of piezoelectric and triboelectric materials to manufacture self-powered nanogenerators, and conclude with an outlook on the current challenges and future potential in meeting medical needs and commercialization.

17.
J Clin Med ; 10(22)2021 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34830626

RESUMO

INTRODUCTION: In patients under immunosuppression or severe sepsis, it is sometimes manifested as coexisting septic arthritis and spondylitis. The aim of this study is to evaluate and investigate the risk factors of infectious spondylitis associated with septic arthritis. METHODS: The study retrospectively reviewed the patients diagnosed with infectious spondylitis between January 2010 and September 2018 for risk factors of coexisting major joint septic arthritis. RESULTS: A total of 10 patients with infectious spondylitis and coexisting septic arthritis comprised the study group. Fifty matched patients with solely infectious spondylitis were selected as the control group. Major risk factors include preoperative C-reactive protein (p = 0.001), hypoalbuminemia (p = 0.011), history of total joint replacement (p < 0.001), duration of preoperative antibiotics treatment (p = 0.038) and psoas muscle abscess (p < 0.001). CONCLUSION: Infectious spondylitis and septic arthritis are thought of as medical emergencies due to their high mortality and morbidity. Our study evaluated 5 risk factors as significant major findings: hypoalbuminemia (<3.4 g/dL), higher preoperative CRP (>130 mg/L), psoas muscle abscess, longer preoperative antibiotics treatment (>8 days) and history of total joint replacement. Clinicians should pay attention to the patients with those five factors to detect the coexisting infections as early as possible.

18.
Biomed Mater ; 16(5)2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410226

RESUMO

Poly(methyl methacrylate) (PMMA) has been widely used in orthopedic applications, but bone ingrowth and toxic monomer release are drawback of this material. Particle reinforcement with osteoconductive substitute, such as calcium sulfate (CaSO4), is one of the solutions used to modify PMMA bone cement. The current study investigated the mechanical, chemical and biological properties of CaSO4-augmented bone cement. Mechanical strength was measured by a material testing machine. The concentration of methyl methacrylate (MMA) monomer from the various formulations of PMMA mixed with CaSO4was measured by ultra-performance liquid chromatography (UPLC). CCK-8 assay and ALP assay were performed to evaluate cytotoxicity of released MMA monomer and cell differentiation. The attachment of cells to CaSO4-augmented bone cement discs was observed by confocal and scanning electron microscopy, and surface topography was also evaluated by atomic force microscopy. The results revealed that increased CaSO4weight ratios led to compromised mechanical strength and increased MMA monomer release. Cell density and cell differentiation on CaSO4-augmented bone cement discs were decreased at CaSO4weight ratios above 10%. In addition, the presence of micropores on the surface and surface roughness were both increased for PMMA composite discs containing higher levels of CaSO4. These results demonstrated that fewer MC3T3-E1 cells on the surface of CaSO4-PMMA composites was correlated to increased MMA monomer release, micropore number and surface roughness. In summary, the augmentation of a higher proportion of CaSO4(>10 wt. %) to PMMA did not promote the biological properties of traditional PMMA bone cement.


Assuntos
Cimentos Ósseos , Sulfato de Cálcio , Adesão Celular/efeitos dos fármacos , Polimetil Metacrilato , Animais , Cimentos Ósseos/química , Cimentos Ósseos/farmacologia , Cimentos Ósseos/toxicidade , Sulfato de Cálcio/química , Sulfato de Cálcio/farmacologia , Sulfato de Cálcio/toxicidade , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Camundongos , Osteoblastos/efeitos dos fármacos , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Polimetil Metacrilato/toxicidade , Propriedades de Superfície
19.
Sci Rep ; 11(1): 12783, 2021 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-34140626

RESUMO

Minimal invasive spinal fusion has become popular in the last decade. Oblique lumbar interbody fusion (OLIF) is a relatively new surgical technique and could avoid back muscle stripping and posterior complex destruction as in minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). Between December 2016 and September 2018, patients with single level degenerative spondylosis were selected to enroll in this retrospective study. A total of 21 patients that underwent OLIF and 41 patients that received MIS-TLIF were enrolled. OLIF showed significantly less blood loss and shorter surgery time compared to MIS-TLIF (p < 0.05). The improvement in segmental lordosis and coronal balance was significantly more in OLIF group than MIS-TLIF group (p < 0.05). When comparing with MIS-TLIF, OLIF was significantly better in Oswestry Disability Index (ODI) and visual analogue scale for back pain improvement at post-operative 6 months (p < 0.05). Both OLIF and MIS-TLIF are becoming mainstream procedures for lumbar degenerative-related disease, especially for spondylolisthesis. However, the indirect decompression of OLIF has shown to have less perioperative blood loss and shorter surgery time than that of MIS-TLIF. In addition, OLIF gives superior outcome in restoring segmental lordosis and coronal imbalance. While both OLIF and MIS-TLIF provide optimal clinical outcomes, upon comparison between the two techniques, the indirect decompression of OLIF seems to be a superior option in modern days.


Assuntos
Descompressão Cirúrgica , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Fusão Vertebral , Espondilolistese/cirurgia , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Espondilolistese/diagnóstico , Espondilolistese/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...