Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Psychol ; 15: 1356435, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38939229

RESUMO

Introduction: Mental health literacy is viewed as a significant factor that may facilitate an individual's pursuit of professional psychological assistance. However, it is important to explore further influencing factors that might underlie this association. This study, employing the framework of the Theory of Planned Behavior (TPB), aims to examine the relationship between mental health literacy and the behavior of seeking professional psychological help, with a focus on the potential mediating roles of perceived stigma and social support in this context. Methods: We surveyed 911 college students in seven regions of China (406 males and 505 females, aged between 19 and 25 years old; M age = 19.65, SD = 1.41) utilizing self-report measures, including the Mental Health Literacy Questionnaire, Professional Psychological Help-Seeking Behavior Scale, Professional Psychological Help-Seeking Stigma Scale, and Perceived Social Support Scale. A chain mediation model was developed to analyze the interconnections between mental health literacy, stigma related to seeking psychological help, perceived social support, and professional psychological help-seeking behaviors. Results: The mediation effect analysis indicates that: (1) mental health literacy significantly positively correlates with professional psychological help-seeking behaviors; (2) both perceived social support and professional psychological help-seeking stigma significantly mediate the relationship between mental health literacy and professional psychological help-seeking behavior; (3) perceived social support and the stigma associated with seeking professional psychological help play a chained mediating effect between mental health literacy and the behavior of seeking professional psychological help. Discussion: This study found that mental health literacy indirectly facilitates professional psychological help-seeking behaviors by enhancing the perception of social support and reducing the stigma associated with seeking such help. These findings help in understanding how improving mental health literacy and perceived social support while reducing stigma can increase the likelihood of individuals seeking professional psychological assistance. The results are significant for enhancing the utilization of mental health services and implementing mental health education programs in universities.

2.
World Neurosurg ; 113: e51-e69, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29408716

RESUMO

OBJECTIVE: Fluorescence-guided surgery with protoporphyrin IX (PpIX) as a photodiagnostic marker is gaining acceptance for resection of malignant gliomas. Current wide-field imaging technologies do not have sufficient sensitivity to detect low PpIX concentrations. We evaluated a scanning fiber endoscope (SFE) for detection of PpIX fluorescence in gliomas and compared it to an operating microscope (OPMI) equipped with a fluorescence module and to a benchtop confocal laser scanning microscope (CLSM). METHODS: 5-Aminolevulinic acid-induced PpIX fluorescence was assessed in GL261-Luc2 cells in vitro and in vivo after implantation in mouse brains, at an invading glioma growth stage, simulating residual tumor. Intraoperative fluorescence of high and low PpIX concentrations in normal brain and tumor regions with SFE, OPMI, CLSM, and histopathology were compared. RESULTS: SFE imaging of PpIX correlated to CLSM at the cellular level. PpIX accumulated in normal brain cells but significantly less than in glioma cells. SFE was more sensitive to accumulated PpIX in fluorescent brain areas than OPMI (P < 0.01) and dramatically increased imaging time (>6×) before tumor-to-background contrast was diminished because of photobleaching. CONCLUSIONS: SFE provides new endoscopic capabilities to view PpIX-fluorescing tumor regions at cellular resolution. SFE may allow accurate imaging of 5-aminolevulinic acid labeling of gliomas and other tumor types when current detection techniques have failed to provide reliable visualization. SFE was significantly more sensitive than OPMI to low PpIX concentrations, which is relevant to identifying the leading edge or metastasizing cells of malignant glioma or to treating low-grade gliomas. This new application has the potential to benefit surgical outcomes.


Assuntos
Ácido Aminolevulínico/farmacocinética , Neoplasias Encefálicas/química , Tecnologia de Fibra Óptica/instrumentação , Corantes Fluorescentes/análise , Glioma/química , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Neuroendoscópios , Neuroendoscopia/instrumentação , Fármacos Fotossensibilizantes/análise , Protoporfirinas/análise , Cirurgia Assistida por Computador/métodos , Administração Oral , Ácido Aminolevulínico/administração & dosagem , Animais , Biotransformação , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Feminino , Genes Reporter , Glioma/diagnóstico por imagem , Glioma/patologia , Camundongos , Camundongos Endogâmicos C57BL , Microscopia Confocal/instrumentação , Microscopia de Fluorescência/instrumentação , Gradação de Tumores , Invasividade Neoplásica , Transplante de Neoplasias , Neuroendoscopia/métodos , Fotodegradação , Protoporfirinas/biossíntese , Análise de Célula Única , Cirurgia Assistida por Computador/instrumentação
3.
Int J Med Robot ; 14(1)2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29105281

RESUMO

BACKGROUND: Complete brain tumour resection is an extremely critical factor for patients' survival rate and long-term quality of life. This paper introduces a prototype medical robotic system that aims to automatically detect and clean up brain tumour residues after the removal of tumour bulk through conventional surgery. METHODS: We focus on the development of an integrated surgical robotic system for image-guided robotic brain surgery. The Behavior Tree framework is explored to coordinate cross-platform medical subtasks. RESULTS: The integrated system was tested on a simulated laboratory platform. Results and performance indicate the feasibility of supervised semi-automation for residual brain tumour ablation in a simulated surgical cavity with sub-millimetre accuracy. The modularity in the control architecture allows straightforward integration of further medical devices. CONCLUSIONS: This work presents a semi-automated laboratory setup, simulating an intraoperative robotic neurosurgical procedure with real-time endoscopic image guidance and provides a foundation for the future transition from engineering approaches to clinical application.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico por imagem , Glioma/cirurgia , Procedimentos Cirúrgicos Robóticos , Técnicas Estereotáxicas , Cirurgia Assistida por Computador/métodos , Encéfalo , Desenho Assistido por Computador , Endoscopia , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Procedimentos Neurocirúrgicos , Processamento de Sinais Assistido por Computador , Software
4.
Artigo em Inglês | MEDLINE | ID: mdl-34321709

RESUMO

For patients with malignant brain tumors (glioblastomas), a safe maximal resection of tumor is critical for an increased survival rate. However, complete resection of the cancer is hard to achieve due to the invasive nature of these tumors, where the margins of the tumors become blurred from frank tumor to more normal brain tissue, but in which single cells or clusters of malignant cells may have invaded. Recent developments in fluorescence imaging techniques have shown great potential for improved surgical outcomes by providing surgeons intraoperative contrast-enhanced visual information of tumor in neurosurgery. The current near-infrared (NIR) fluorophores, such as indocyanine green (ICG), cyanine5.5 (Cy5.5), 5-aminolevulinic acid (5-ALA)-induced protoporphyrin IX (PpIX), are showing clinical potential to be useful in targeting and guiding resections of such tumors. Real-time tumor margin identification in NIR imaging could be helpful to both surgeons and patients by reducing the operation time and space required by other imaging modalities such as intraoperative MRI, and has the potential to integrate with robotically assisted surgery. In this paper, a segmentation method based on the Chan-Vese model was developed for identifying the tumor boundaries in an ex-vivo mouse brain from relatively noisy fluorescence images acquired by a multimodal scanning fiber endoscope (mmSFE). Tumor contours were achieved iteratively by minimizing an energy function formed by a level set function and the segmentation model. Quantitative segmentation metrics based on tumor-to-background (T/B) ratio were evaluated. Results demonstrated feasibility in detecting the brain tumor margins at quasi-real-time and has the potential to yield improved precision brain tumor resection techniques or even robotic interventions in the future.

5.
Rep U S ; 2015: 2639-2645, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26705501

RESUMO

This paper considers the semi-automated robotic surgical procedure for removing the brain tumor margins, where the manual operation is a tedious and time-consuming task for surgeons. We present robust path planning methods for robotic ablation of tumor residues in various shapes, which are represented in point-clouds instead of analytical geometry. Along with the path plans, corresponding metrics are also delivered to the surgeon for selecting the optimal candidate in the automated robotic ablation. The selected path plan is then executed and tested on RAVEN™ II surgical robot platform as part of the semi-automated robotic brain tumor ablation surgery in a simulated tissue phantom.

6.
IEEE Int Conf Robot Autom ; 2015: 3868-3875, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26405563

RESUMO

Medical robots have been widely used to assist surgeons to carry out dexterous surgical tasks via various ways. Most of the tasks require surgeon's operation directly or indirectly. Certain level of autonomy in robotic surgery could not only free the surgeon from some tedious repetitive tasks, but also utilize the advantages of robot: high dexterity and accuracy. This paper presents a semi-autonomous neurosurgical procedure of brain tumor ablation using RAVEN Surgical Robot and stereo visual feedback. By integrating with the behavior tree framework, the whole surgical task is modeled flexibly and intelligently as nodes and leaves of a behavior tree. This paper provides three contributions mainly: (1) describing the brain tumor ablation as an ideal candidate for autonomous robotic surgery, (2) modeling and implementing the semi-autonomous surgical task using behavior tree framework, and (3) designing an experimental simulated ablation task for feasibility study and robot performance analysis.

7.
Proc SPIE Int Soc Opt Eng ; 9415: 94150C, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25821389

RESUMO

The challenge is to accurately guide the surgical tool within the three-dimensional (3D) surgical field for robotically-assisted operations such as tumor margin removal from a debulked brain tumor cavity. The proposed technique is 3D image-guided surgical navigation based on matching intraoperative video frames to a 3D virtual model of the surgical field. A small laser-scanning endoscopic camera was attached to a mock minimally-invasive surgical tool that was manipulated toward a region of interest (residual tumor) within a phantom of a debulked brain tumor. Video frames from the endoscope provided features that were matched to the 3D virtual model, which were reconstructed earlier by raster scanning over the surgical field. Camera pose (position and orientation) is recovered by implementing a constrained bundle adjustment algorithm. Navigational error during the approach to fluorescence target (residual tumor) is determined by comparing the calculated camera pose to the measured camera pose using a micro-positioning stage. From these preliminary results, computation efficiency of the algorithm in MATLAB code is near real-time (2.5 sec for each estimation of pose), which can be improved by implementation in C++. Error analysis produced 3-mm distance error and 2.5 degree of orientation error on average. The sources of these errors come from 1) inaccuracy of the 3D virtual model, generated on a calibrated RAVEN robotic platform with stereo tracking; 2) inaccuracy of endoscope intrinsic parameters, such as focal length; and 3) any endoscopic image distortion from scanning irregularities. This work demonstrates feasibility of micro-camera 3D guidance of a robotic surgical tool.

8.
J Med Imaging (Bellingham) ; 1(3): 035002, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26158071

RESUMO

Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design.

9.
Artigo em Inglês | MEDLINE | ID: mdl-34321710

RESUMO

Endoscopic visualization in brain tumor removal is challenging because tumor tissue is often visually indistinguishable from healthy tissue. Fluorescence imaging can improve tumor delineation, though this impairs reflectance-based visualization of gross anatomical features. To accurately navigate and resect tumors, we created an ultrathin/flexible, scanning fiber endoscope (SFE) that acquires reflectance and fluorescence wide-field images at high-resolution. Furthermore, our miniature imaging system is affixed to a robotic arm providing programmable motion of SFE, from which we generate multimodal surface maps of the surgical field. To test this system, synthetic phantoms of debulked tumor from brain are fabricated having spots of fluorescence representing residual tumor. Three-dimension (3D) surface maps of this surgical field are produced by moving the SFE over the phantom during concurrent reflectance and fluorescence imaging (30Hz video). SIFT-based feature matching between reflectance images is implemented to select a subset of key frames, which are reconstructed in 3D by bundle adjustment. The resultant reconstruction yields a multimodal 3D map of the tumor region that can improve visualization and robotic path planning. Efficiency of creating these 3D maps is important as they are generated multiple times during tumor margin clean-up. By using pre-programmed motions of the robot arm holding the SFE, the computer vision algorithms are optimized for efficiency by reducing search times. Preliminary results indicate that the time for creating these multimodal maps of the surgical field can be reduced to one third by using known trajectories of the surgical robot moving the image-guided tool.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...