Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancer Res Commun ; 4(1): 5-17, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38047587

RESUMO

The phosphatases of regenerating liver (PRL) are oncogenic when overexpressed. We previously found that PRL2 deletion increases PTEN, decreases Akt activity, and suppresses tumor development in a partial Pten-deficient mouse model. The current study aims to further establish the mechanism of PTEN regulation by PRL2 and expand the therapeutic potential for PTEN augmentation mediated by PRL2 inhibition in cancers initiated without PTEN alteration. The TP53 gene is the most mutated tumor suppressor in human cancers, and heterozygous or complete deletion of Tp53 in mice leads to the development of sarcomas and thymic lymphomas, respectively. There remains a lack of adequate therapies for the treatment of cancers driven by Tp53 deficiency or mutations. We show that Prl2 deletion leads to PTEN elevation and attenuation of Akt signaling in sarcomas and lymphomas developed in Tp53 deficiency mouse models. This results in increased survival and reduced tumor incidence because of impaired tumor cell proliferation. In addition, inhibition of PRL2 with a small-molecule inhibitor phenocopies the effect of genetic deletion of Prl2 and reduces Tp53 deficiency-induced tumor growth. Taken together, the results further establish PRL2 as a negative regulator of PTEN and highlight the potential of PRL2 inhibition for PTEN augmentation therapy in cancers with wild-type PTEN expression. SIGNIFICANCE: Prl2 deletion attenuates Tp53 deficiency-induced tumor growth by increasing PTEN and reducing Akt activity. Targeting Tp53-null lymphoma with PRL inhibitors lead to reduced tumor burden, providing a therapeutic approach via PTEN augmentation.


Assuntos
Linfoma , Sarcoma , Neoplasias de Tecidos Moles , Humanos , Animais , Camundongos , Proteínas Proto-Oncogênicas c-akt/metabolismo , Transdução de Sinais , Genes Supressores de Tumor , Linfoma/tratamento farmacológico , PTEN Fosfo-Hidrolase/genética
2.
Anal Chem ; 95(46): 17082-17088, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37937965

RESUMO

Biothreat detection has continued to gain attention. Samples suspected to fall into any of the CDC's biothreat categories require identification by processes that require specialized expertise and facilities. Recent developments in analytical instrumentation and machine learning algorithms offer rapid and accurate classification of Gram-positive and Gram-negative bacterial species. This is achieved by analyzing the negative ions generated from bacterial cell extracts with a modified linear quadrupole ion-trap mass spectrometer fitted with two-dimensional tandem mass spectrometry capabilities (2D MS/MS). The 2D MS/MS data domain of a bacterial cell extract is recorded within five s using a five-scan average after sample preparation by a simple extraction. Bacteria were classified at the species level by their lipid profiles using the random forest, k-nearest neighbor, and multilayer perceptron machine learning models. 2D MS/MS data can also be treated as image data for use with image recognition algorithms such as convolutional neural networks. The classification accuracy of all models tested was greater than 99%. Adding to previously published work on the 2D MS/MS analysis of bacterial growth and the profiling of sporulating bacteria, this study demonstrates the utility and information-rich nature of 2D MS/MS in the identification of bacterial pathogens at the species level when coupled with machine learning.


Assuntos
Bactérias , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Algoritmos , Redes Neurais de Computação , Aprendizado de Máquina
3.
Analyst ; 148(7): 1430-1436, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36892479

RESUMO

We demonstrate proof-of-concept for point-of-care assessment of long-term alcohol consumption by measuring phosphatidylethanol in blood/dried blood spots with nano-electrospray ionization and MS/MS using a miniature mass spectrometer. 'Abstinence', 'moderate', and 'chronic' consumption could be distinguished rapidly for both sample types, and quantitative performance was obtained with blood (LoQ-100 ng mL-1).


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Espectrometria de Massas em Tandem , Glicerofosfolipídeos , Consumo de Bebidas Alcoólicas , Biomarcadores
4.
Anal Bioanal Chem ; 414(11): 3387-3395, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35169905

RESUMO

HIV prevention and treatment with injectable cabotegravir and/or rilpivirine administered once every 4 to 8 weeks is an attractive alternative to daily therapy. Prescribed dosage and drug concentrations in plasma are based on patient data collected in clinical trials, but actual patients are expected to exhibit more variability in drug concentrations, which is important to quantify. Here, we demonstrate the first quantitative point-of-care assay with a miniature mass spectrometer to assess these drug concentrations in whole blood. Quantitative performance is obtained using paper spray ionization in combination with tandem mass spectrometry (MS/MS) in the clinically relevant concentration range of both drugs. Limits of quantitation (LoQs) of cabotegravir and rilpivirine are measured to be 750 ng/mL and 20 ng/mL, respectively. The assay turnaround time is < 4 min, and strong linear relationships are established between MS/MS responses and concentration, with percentage of relative standard deviations (RSDs) that are <15% at concentrations above the LoQs. The speed, portability, low power consumption, and specificity offered by the miniature instrument should make it an appropriate platform for measuring drug concentrations in a walk-in clinic using small volumes of patient blood.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , HIV-1 , Dicetopiperazinas , Infecções por HIV/tratamento farmacológico , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Piridonas , Rilpivirina/efeitos adversos , Espectrometria de Massas em Tandem
5.
Anal Chem ; 93(41): 13904-13911, 2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34617742

RESUMO

Advances in ambient ionization techniques have facilitated the direct analysis of complex mixtures without sample preparation. Significant attention has been given to innovating ionization methods so that multiple options are now available, allowing for ready selection of the best methods for particular analyte classes. These ambient techniques are commonly implemented on benchtop systems, but their potential application with miniature mass spectrometers for in situ measurements is even more powerful. These applications require that attention be paid to tailoring the mass spectrometric methodology for the on-site operation. In this study, combinations of scan modes are employed to efficiently determine what tandem mass spectrometry (MS/MS) operations are most useful for detecting sulfonamides using a miniature ion trap after ionization. First, mixtures of representative sulfonamide antibiotics were interrogated using a 2D MS/MS scan on a benchtop ion trap in order to determine which class-specific fragments (ionic or neutral) are shared between the sulfonamides and thus have diagnostic value. Then, three less-used combination scans were recorded: (i) a simultaneous precursor ion scan was used to detect both analytes and an internal standard in a single ion injection event to optimize quantitative performance; (ii) a simultaneous precursor/neutral loss scan was used to improve detection limits; and finally, (iii) the simultaneous precursor/neutral loss scan was implemented in a miniature mass spectrometer and representative sulfonamides were detected at concentrations as low as 100 ng/mL by nano-electrospray and 0.5 ng absolute by paper spray ionization, although improvements in the stability of the home-built instrumentation are needed to further optimize performance.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Antibacterianos , Sulfanilamida , Sulfonamidas
6.
Pharm Res ; 37(7): 138, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32651732

RESUMO

PURPOSE: Forced degradation is critical to probe the stabilities and chemical reactivities of therapeutic peptides. Typically performed in bulk followed by LC-UV or LC-MS analysis, this traditional workflow consists of a reaction/analysis sequence and usually requires half a day to several days to form and measure the desired amounts of degradants. A faster method is needed to study peptide degradation in a shorter time in order to speed up the drug development process. METHODS: In the new rapid method developed in this study, peptide degradation occurs in levitated aqueous microdroplets using the Leidenfrost effect. RESULTS: This two-minute reaction/analysis workflow allows major degradation pathways of Buserelin, Octreotide, Desmopressin and Leuprorelin to be studied. The reactions include deamidation, disulfide bond cleavage, ether cleavage, peptide bond hydrolysis, and oxidation. CONCLUSIONS: The accelerated forced degradation method requires a minimal amount of therapeutic peptide per stress condition, and the appropriate extent of degradation can be readily generated in seconds by adjusting the droplet levitation time. Levitated microdroplets should be applicable in pharmaceutical development to rapidly determine the intrinsic stability of therapeutic peptides and to aid formulation development by screening the effects of excipients on the stability of the peptides. Graphical abstract.


Assuntos
Busserrelina/química , Desamino Arginina Vasopressina/química , Leuprolida/química , Octreotida/química , Composição de Medicamentos , Estabilidade de Medicamentos , Temperatura Alta , Concentração de Íons de Hidrogênio , Cinética , Tamanho da Partícula , Estabilidade Proteica , Proteólise , Fluxo de Trabalho
7.
Chem Sci ; 8(6): 4363-4370, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28979759

RESUMO

A highly integrated approach to the development of a process for the continuous synthesis and purification of diphenhydramine is reported. Mass spectrometry (MS) is utilized throughout the system for on-line reaction monitoring, off-line yield quantitation, and as a reaction screening module that exploits reaction acceleration in charged microdroplets for high throughput route screening. This effort has enabled the discovery and optimization of multiple routes to diphenhydramine in glass microreactors using MS as a process analytical tool (PAT). The ability to rapidly screen conditions in charged microdroplets was used to guide optimization of the process in a microfluidic reactor. A quantitative MS method was developed and used to measure the reaction kinetics. Integration of the continuous-flow reactor/on-line MS methodology with a miniaturized crystallization platform for continuous reaction monitoring and controlled crystallization of diphenhydramine was also achieved. Our findings suggest a robust approach for the continuous manufacture of pharmaceutical drug products, exemplified in the particular case of diphenhydramine, and optimized for efficiency and crystal size, and guided by real-time analytics to produce the agent in a form that is readily adapted to continuous synthesis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...