Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 23(1): 225, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208745

RESUMO

PURPOSE: To investigate the distribution and changes in ocular biometry in 4-to to 9-year-old Chinese children and to compare the differences between age and genders in these parameters. METHODS: This was a school-based cross-sectional study. A total of 1,528 Chinese children, aged 4-9 years, from one primary school and 12 kindergartens, were included in the study. Axial length, corneal curvature, anterior chamber depth, and corneal diameter were measured for each child. RESULTS: AL and anterior chamber depth gradually increased with age in both genders. No significant changes in corneal curvature or corneal diameter were detected at different ages in either genders group. The mean ALs of males and females were 22.94 ± 0.80 mm and 22.38 ± 0.79 mm, respectively. The mean corneal curvatures of males and females were 43.05 ± 1.37 D and 43.75 ± 1.48 D, respectively. The mean anterior chamber depth of males and females were 3.47 ± 0.24 mm and 3.38 ± 0.25 mm, respectively. The mean corneal diameter of males and females were 12.08 ± 0.43 mm and 11.94 ± 0.44 mm, respectively. Females had consistently shorter ALs, shorter anterior chamber depth, smaller corneal diameter, and steeper corneal curvatures than males at any age. CONCLUSIONS: Boys had larger dimensions than girls for all ocular parameters except corneal curvature (flatter). Boys and girls showed similar trends for all parameters. Axial length and anterior chamber depth increased from 4 to 9 years of age, whereas corneal diameter and curvature did not change with age in either genders.


Assuntos
Córnea , População do Leste Asiático , Criança , Humanos , Feminino , Masculino , Pré-Escolar , Estudos Transversais , Córnea/anatomia & histologia , Povo Asiático , Biometria/métodos , Refração Ocular , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho
2.
Int J Ophthalmol ; 15(5): 728-735, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35601182

RESUMO

AIM: To detect an earlier improvement in mild to moderate keratoconus following corneal cross-linking (CXL) with total corneal refractive power (TCRP) using ray tracing method. METHODS: A total of 40 eyes of 30 consecutive patients who underwent CXL for progressive keratoconus were retrospectively enrolled. The following keratometric parameters provided by Pentacam HR, including maximum keratometry (Kmax), steepest keratometry (Ksteep), 3 mm zonal TCRP centered over corneal apex (TCRPapex,zone 3 mm), zonal mean keratometry and TCRP centered over corneal cone (Kmcone,zone and TCRPcone,zone 1, 2, 3 mm) were evaluated preoperatively and 1, 3, 6, and 12mo postoperatively. Groups 1 and 2 were defined based on Kmax at postoperative 1mo as improved (the initial improvement group) or worsen (the initial deterioration group) compared to the preoperative level. RESULTS: In the overall group, only keratometric parameters based on ray tracing method displayed significant improvement early at 3mo postoperatively, in which TCRPcone,zone 1 mm and 2 mm exhibited the largest flattening (0.57 D and 0.53 D, respectively). In Group 1, only Kmax, Kmcone,zone 2 mm and TCRPcone,zone 2 mm showed significant improvement initially at 1mo postoperatively, in which Kmax exhibited the largest improvement (1.05 D), followed by TCRPcone,zone 2 mm (0.82 D). In Group 2, only keratometric parameters based on ray tracing method and Kmcone,zone 3 mm showed slight but not significant improvement early at 3mo, in which TCRPcone,zone 3 mm displayed the most improvement (0.19 D), followed by TCRPcone,zone 2 mm (0.15 D). CONCLUSION: The findings indicate that a 2 mm zonal TCRP centered over Kmax could earlier detect keratometric improvement by CXL compared to other commonly used parameters in mild to moderate keratoconic eyes.

3.
Int J Ophthalmol ; 11(12): 1957-1962, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30588430

RESUMO

AIM: To evaluate the thickness and volume changes of the choroidal, outer retinal layers (ORL) and retinal pigment epithelium (RPE) in patients with diabetic retinopathy (DR) using optical coherence tomography (OCT) and correlate them with visual acuity. METHODS: We carried out a retrospective observational case series. Consecutive DR patients were recruited for color fundus photography and OCT assessment. The RPE, ORL and choroidal thickness were measured. The correlation with the best-corrected visual acuity (BCVA) was also investigated. RESULTS: The study included 128 eyes, comprising 45 eyes of 25 diabetic macular edema (DME) patients, 34 eyes of 20 DR without DME (non-DME) patients, and 49 eyes of 25 age-matched normal individuals. The choroidal thickness in DR patients were decreased statistically significantly compared with the control group (P<0.05). The mean macular ORL thickness in DME (73.02±15.34 µm) and non-DME groups (76.35±7.32 µm) were decreased statistically significantly compared with the control group (80.20±5.85 µm; P=0.006, P=0.013, respectively). In both the non-DME and DME groups, the RPE thickness were decreased compared with the control group (P<0.05), except in the macular and central ring. The BCVA were significant interactions with the total inner retinal volume and macular RPE thickness in the DME group (r=0.115, P<0.001, r=-0.013, P=0.017, respectively). CONCLUSION: The choroid, ORL and RPE thickness are significantly decreased in DR patients compared with controls in different segments.

4.
Zhonghua Yi Xue Za Zhi ; 92(33): 2339-44, 2012 Sep 04.
Artigo em Chinês | MEDLINE | ID: mdl-23158564

RESUMO

OBJECTIVE: To compare the different evaluations of corneal power in post-laser-assisted in situ keratomileusis (LASIK) eyes and assess the accuracy and differences of intraocular lens (IOL) power prediction with corneal powers through different calculation methods. METHODS: For this prospective study, 71 eyes of 39 candidates undergoing LASIK and 3 months later returning for reexamination were included. All subjects were divided into 2 groups according to the axial length: Group A (23.46 - 25.97 mm) 44 eyes, Group B (26.00 - 28.52 mm) 27 eyes. The ranges of spherical equivalents were -1.75 - -9.50 D with an average of (-4.82 ± 1.98) D. Subjective refraction and Pentacam Scheimpflug analyzer were performed at pre-operation and subjective refraction, IOLMaster and Galilei II dual Scheimpflug analyzer at over 3 months post-operation. The following values were obtained: SimK by Galilei II dual Scheimpflug analyzer, Kn calculated with Gaussion thick lens formula, Kray with ray tracing method, Kchm calculated with clinical history method and Km by IOLMaster. Repeated measures analysis of variance analyze the differences between SimK, Kn, Kray, Km and Kchm. Repeated measurement analysis of variance was employed to analyze the differences between SimK, Kn, Kray, Km combining intraocular lens power formula and Kchm combining intraocular lens power formula. Pearson's analysis was performed to analyze the correlations between SimK, Kn, Kray, Km and Kchm. Those combining with formulas for IOL power calculations were also analyzed. P < 0.05 indicated statistical significance. RESULTS: The values of SimK, Kn, Kray, Km and Kchm were (39.02 ± 1.8), (37.8 ± 1.51), (36.8 ± 1.84), (39.18 ± 1.75) and (38.55 ± 1.83) D respectively. The differences between SimK, Kn, Kray, Km and Kchm had statistical significances (P < 0.01). High correlations existed between SimK, Kn, Kray, Km and Kchm (r > 0.9, P < 0.01). In the same IOL formula, Kray had the highest IOL power value, Kn followed, Kchm the third, SimK and Km the smallest. Among the IOL formulas, Haigis-L and Haigis predicted the highest IOL power, HofferQ followed, Holladay the third and SRK/T the smallest. CONCLUSION: Kn/Kray combining with Haigis formula may be a new and effective method for predicting the IOL power in post-LASIK eyes.


Assuntos
Córnea/fisiopatologia , Córnea/cirurgia , Refração Ocular , Adolescente , Adulto , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ , Implante de Lente Intraocular , Lentes Intraoculares , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...