Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 13(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38131766

RESUMO

Integrating biosensors with smartphones is becoming an increasingly popular method for detecting various biomolecules and could replace expensive laboratory-based instruments. In this work, we demonstrate a novel smartphone-based biosensor system with a gradient grating period guided-mode resonance (GGP-GMR) sensor. The sensor comprises numerous gratings which each correspond to and block the light of a specific resonant wavelength. This results in a dark band, which is observed using a CCD underneath the GGP-GMR sensor. By monitoring the shift in the dark band, the concentration of a molecule in a sample can be determined. The sensor is illuminated by a light-emitting diode, and the light transmitted through the GGP-GMR sensor is directly captured by a smartphone, which then displays the results. Experiments were performed to validate the proposed smartphone biosensor and a limit of detection (LOD) of 1.50 × 10-3 RIU was achieved for sucrose solutions. Additionally, multiplexed detection was demonstrated for albumin and creatinine solutions at concentrations of 0-500 and 0-1 mg/mL, respectively; the corresponding LODs were 1.18 and 20.56 µg/mL.


Assuntos
Técnicas Biossensoriais , Smartphone , Técnicas Biossensoriais/métodos , Limite de Detecção
2.
Biosensors (Basel) ; 14(1)2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38248398

RESUMO

Handheld biosensors have attracted substantial attention for numerous applications, including disease diagnosis, drug dosage monitoring, and environmental sensing. This study presents a novel handheld biosensor based on a gradient grating period guided-mode resonance (GGP-GMR) sensor. Unlike conventional GMR sensors, the proposed sensor's grating period varies along the device length; hence, the resonant wavelength varies linearly along the device length. If a GGP-GMR sensor is illuminated with a narrow band of light at normal incidence, the light resonates and reflects at a specific period but transmits at other periods; this can be observed as a dark band by using a complementary metal oxide semiconductor (CMOS) underneath the sensor. The concentration of a target analyte can be determined by monitoring the shift of this dark band. We designed and fabricated a handheld device incorporating a light-emitting diode (LED) light source, the necessary optics, an optofluidic chip with an embedded GGP-GMR sensor, and a CMOS. LEDs with different beam angles and bandpass filters with different full width at half maximum values were investigated to optimize the dark band quality and improve the accuracy of the subsequent image analysis. Substrate materials with different refractive indices and waveguide thicknesses were also investigated to maximize the GGP-GMR sensor's figure of merit. Experiments were performed to validate the proposed handheld biosensor, which achieved a limit of detection (LOD) of 1.09 × 10-3 RIU for bulk solution measurement. The sensor's performance in the multiplexed detection of albumin and creatinine solutions at concentrations of 0-500 µg/mL and 0-10 mg/mL, respectively, was investigated; the corresponding LODs were 0.66 and 0.61 µg/mL.


Assuntos
Monitoramento de Medicamentos , Processamento de Imagem Assistida por Computador , Creatinina , Limite de Detecção , Óxidos
3.
Stem Cell Res Ther ; 13(1): 331, 2022 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-35870968

RESUMO

BACKGROUND: Due to the large area and deep width of the artificial neovagina after vaginoplasty, it takes a considerable amount of time to achieve complete epithelization of the neovagina. Currently, the clinical therapies for vaginal epithelization after vaginoplasty are still dissatisfactory. Recent studies showed that small extracellular vesicles (sEVs) derived from stem cells could accelerate wound epithelization. The sustained release of sEVs from optimized hydrogels may be a promising strategy to accelerate vaginal epithelization after vaginoplasty. METHODS: The efficacy of phototriggered imine crosslink hydrogels (piGEL) containing sEVs derived from human urine-derived stem cells (hUSC-sEVs, piGEL-sEVs) on vaginal mucosa defects in rabbits was assessed by wound closure rates, histological analysis and immunofluorescence staining analysis. Cell counting kit-8, 5-ethynyl-2'-deoxyuridine and scratch wound assays were performed to assess the effects of hUSC-sEVs on the proliferation and migration ability of vaginal epithelial cells (VK2/E6E7). Quantitative real-time polymerase chain reaction (qRT-PCR) was carried out to test the expression of epithelial differentiation markers in VK2 cells. Moreover, a microRNA (miRNA) microarray was used to find hUSC-sEVs-specific miRNAs that potentially affected the proliferation, migration and differentiation ability of VK2 cells. RESULTS: The in vitro release profile revealed that the piGEL could ensure sustained release of hUSC-sEVs. The in vivo results showed that piGEL-sEVs effectively promoted epithelization and angiogenesis of vaginal mucosa defects in rabbits. According to miRNA microarray and qRT-PCR results, miR-126-3p might be the crucial molecule among the various miRNAs contained in hUSC-sEVs. The data showed that hUSC-sEVs promoted the migration and differentiation of VK2 cells by delivering miR-126-3p to suppress the expression of Spred1 and PIK3R2, thereby activating the ERK1/2 and ATK signaling pathways. CONCLUSION: The results indicated that piGEL-sEVs could be a novel promising approach for enhancing the epithelization of the neovagina after vaginoplasty and provided useful data for understanding the underlying mechanism of the effect of hUSC-sEVs on epithelization.


Assuntos
Vesículas Extracelulares , MicroRNAs , Animais , Preparações de Ação Retardada/metabolismo , Vesículas Extracelulares/metabolismo , Feminino , Humanos , Hidrogéis/farmacologia , Iminas/metabolismo , MicroRNAs/genética , MicroRNAs/metabolismo , Coelhos , Células-Tronco/metabolismo
4.
Sensors (Basel) ; 21(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33921116

RESUMO

This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500-700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


Assuntos
Colorimetria , Dispositivos Lab-On-A-Chip , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito , Refratometria
5.
Opt Express ; 29(2): 1320-1332, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726350

RESUMO

A novel biosensor based on a two-dimensional gradient (TDG) guided-mode resonance (GMR) filter was introduced in this study. The TDG-GMR is demarcated in terms of the gradient grating period (GGP) in one dimension and gradient waveguide thickness (GWT) in the other dimension. A single compact sensor can combine these two features to simultaneously provide a broad detection range through GGP and high resolution through GWT. A detection range of 0.109 RIU (0%-60% sucrose content) with a limit of detection of 5.62 × 10-4 was demonstrated in this study by using a TDG-GMR with a size of 140.8 × 125.4 µm2. This value cannot be achieved using one dimensional gradient GMR sensor. Label-free (LF) biomolecule detection through TDG-GMR was also experimentally demonstrated in a model assay of albumin. The result confirms that the GWT-GMR provides a better resolution, whereas the GGP-GMR provides a broader detection range. A device for multiplex measurement could be easily implemented with a compact sensor chip and a simple readout directly from a charge-coupled device. This system would require a narrow-band source such as a light emitting diode or a laser diode, in addition to a limited number of other components such as a polarizer and a collimator. The proposed TDG-GMR could easily be integrated with smartphones and portable devices.


Assuntos
Albuminas/análise , Técnicas Biossensoriais/instrumentação , Fotometria/instrumentação , Refratometria/instrumentação , Sacarose/análise , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento
6.
Sensors (Basel) ; 21(2)2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33430392

RESUMO

Portable systems for detecting biomolecules have attracted considerable attention, owing to the demand for point-of-care testing applications. This has led to the development of lab-on-a-chip (LOC) devices. However, most LOCs are developed with a focus on automation and preprocessing of samples; fluorescence measurement, which requires additional off-chip detection instruments, remains the main detection method in conventional assays. By incorporating optical biosensors into LOCs, the biosensing system can be simplified and miniaturized. However, many optical sensors require an additional coupling device, such as a grating or prism, which complicates the optical path design of the system. In this study, we propose a new type of biosensor based on gradient waveguide thickness guided-mode resonance (GWT-GMR), which allows for the conversion of spectral information into spatial information such that the output signal can be recorded on a charge-coupled device for further analysis without any additional dispersive elements. A two-channel microfluidic chip with embedded GWT-GMRs was developed to detect two model assays in a buffer solution: albumin and creatinine. The results indicated that the limit of detection for albumin was 2.92 µg/mL for the concentration range of 0.8-500 µg/mL investigated in this study, and that for creatinine it was 12.05 µg/mL for the concentration range of 1-10,000 µg/mL. These results indicated that the proposed GWT-GMR sensor is suitable for use in clinical applications. Owing to its simple readout and optical path design, the GWT-GMR is considered ideal for integration with smartphones or as miniaturized displays in handheld devices, which could prove beneficial for future point-of-care applications.


Assuntos
Técnicas Biossensoriais , Dispositivos Lab-On-A-Chip , Testes Imediatos
7.
ACS Omega ; 5(36): 23021-23027, 2020 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-32954152

RESUMO

A fine cylindrical chemical sensor tip is developed with optical fiber in the core, surrounded by a transparent cylinder of photopolymer Norland Optical Adhesive 61 (NOA 61), and covered by a polymer hydrogel mixed with sensing molecules. The overall diameter is as small as 1.5 mm. pH response is demonstrated using two approaches of sensing materials: (i) absorbing probe Phenol Red mixed with Rhodamine 6G fluorescent dye and (ii) 8-hydroxypyrene-1,3,6-trisulfonic acid fluorescent probe. Both the optical excitation and fluorescence signal collection are through the optical fibers. A time resolution of 10 s is achieved for pH variations. Good linearity is observed in the physiological range from pH 7.0 to pH 8.6 with reversible and reproducible outcomes. For in vitro urea measurement, the sensor tip can distinguish 1, 3, and 5 mM urea solution, which is a crucial range in saliva urea concentration. The miniaturized tip with such simple cylindrical symmetry is designed to detect vital signs during minimally invasive surgeries and can be potentially accompanied with endoscopes to enter human bodies.

8.
Biosens Bioelectron ; 162: 112230, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32392152

RESUMO

Solid-state zinc ion sensor is developed with high enough resolution and reproducibility for the potential application in brain injury monitoring. An optical diffuser is incorporated into the zinc ion sensor based on optical fiber and hydrogel doped with the fluorescent zinc ion probe molecule meso-2,6-Dichlorophenyltripyrrinone (TPN-Cl2). The diffuser transforms the high-peak-intensity excitation light near the fiber end into a broad light with moderate local intensity to reduce the degradation of the probe molecule. Reversible detection can be reached for 1, 2, and 5 µM (10-6 Molar), with slopes 0.3, 0.6, and 0.8 respectively. This is the pathophysiological concentration range after brain injury. The sensor is applied to neuron-glial cultures and macrophage under the stimulation of lipopolysaccharide (LPS), KCl and oxygen/glucose deprivation (OGD) that reflect inflammation, depolarization and ischemia respectively, mimicking events after brain injury. The zinc ion level is raised to 4-5 µM after LPS treatment, and then reduced to <3 µM after the co-treatment with the herbal drug silymarin. The results suggest the conditions of the neural cells under stress can be monitored.


Assuntos
Técnicas Biossensoriais/métodos , Corantes Fluorescentes/química , Hidrogéis/química , Neurônios/citologia , Zinco/análise , Animais , Células Cultivadas , Neuroglia/química , Neuroglia/citologia , Neurônios/química , Fibras Ópticas , Ratos
9.
Stem Cell Res Ther ; 10(1): 80, 2019 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-30849996

RESUMO

BACKGROUND: Previous studies revealed that urine-derived stem cells (USCs) could promote myogenesis after the impairment of the sphincter muscles. However, the effects of exosomes secreted by USCs (USCs-Exo) were not elucidated. Exosomes are nanosized membrane vesicles secreted by the cells. They have been proved to be effective in protecting against tissue injury and therapeutic in tissue repair. USCs are ideal sources of exosomes because of the noninvasive obtaining method and self-renewal abilitiy. This study aimed to show the therapeutic effects of USCs-Exo on improving stress urinary incontinence (SUI). METHODS: Rat SUI models were established in this study using vaginal balloon inflation, and urodynamic and histological examination were carried out after exosome application. The proliferation and differentiation of muscle satellite cells (SCs) were evaluated using EdU, Cell Counting Kit 8, immunofluorescence staining, and Western blot analysis. mRNAs and proteins related to the activation of SCs were detected by reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) and Western blot analysis. RESULTS: After exosome injection, the urodynamic parameters significantly improved and the injured muscle tissue recovered well. The activation, proliferation, and differentiation of SCs were promoted. The phosphorylation of extracellular-regulated protein kinases (ERK) was enhanced. When ERK was inhibited, the promoting effect of USCs-Exo treatment disappeared. CONCLUSION: The findings of this study elucidated the functional roles of USCs-Exo in satellite cell ERK phosphorylation and identified a novel agent for skeletal muscle regeneration, providing a basis for further exploring a cell-free correction for SUI.


Assuntos
Diferenciação Celular , Exossomos , Desenvolvimento Muscular , Músculo Liso , Células Satélites de Músculo Esquelético , Incontinência Urinária por Estresse , Urina , Animais , Exossomos/metabolismo , Exossomos/patologia , Exossomos/transplante , Feminino , Humanos , Músculo Liso/lesões , Músculo Liso/metabolismo , Músculo Liso/patologia , Ratos , Ratos Sprague-Dawley , Células Satélites de Músculo Esquelético/metabolismo , Células Satélites de Músculo Esquelético/patologia , Incontinência Urinária por Estresse/metabolismo , Incontinência Urinária por Estresse/patologia , Incontinência Urinária por Estresse/terapia
10.
Immunology ; 156(3): 235-248, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30418673

RESUMO

This study focuses on investigating the role of interleukin-1ß (IL-1ß) in functional regeneration following nerve injury in mice. A microarray-based mRNA profiling study was used to analyze the expression level of IL-1ß in peripheral nerve regeneration. Quantitative real-time polymerase chain reaction and Western blot were applied to assess the IL-1ß expressions of C57BL/6J-crush and C57BL/6J-crush+IL-1ß mice at different post-injury time-points after the standard sciatic nerve crush injury. The outcomes of nerve regeneration were evaluated by behavioral tests. IL-1ß was found to be up-regulated in peripheral nerve regeneration and significantly raised on the 3rd day and returned to normal levels on the 14th day after nerve injury. Compared with C57BL/6J-crush+IL-1ß mice, the nerve regeneration of C57BL/6J-crush mice was worse after nerve crush injury. IL-1ß increased mechanical sensitivity and stimulated amplitude. IL-1ß could benefit the recovery of sciatic nerve crush injury by facilitating nerve regeneration.


Assuntos
Interleucina-1beta/imunologia , NF-kappa B/imunologia , Regeneração Nervosa/imunologia , Doenças do Sistema Nervoso/imunologia , Transdução de Sinais/imunologia , Animais , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Regulação para Cima/imunologia
11.
Analyst ; 143(2): 503-510, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-29292430

RESUMO

We demonstrate the detection of C-creative protein (CRP) from whole blood samples without sample pretreatment by using a lab-on-a-chip system consisting of a microfluidic chip and a label-free biosensor. The microfluidic chip includes an array of microposts for filtering blood cells and allows only plasma to flow through and reach the guided-mode resonance (GMR) biosensor for real-time monitoring. The developed GMR sensor can achieve a bulk sensitivity of 186 nm RIU-1, which supports a limit of detection of 3.2 ng mL-1 for recombinant CRP spiked in human serum. The results are comparable with those obtained using enzyme-linked immunosorbent assay. In addition, we demonstrate the efficacy of filtration of blood cells using microposts and simultaneous measurement of CRP concentration using a GMR sensor by using whole blood and plasma samples.


Assuntos
Técnicas Biossensoriais , Proteína C-Reativa/análise , Dispositivos Lab-On-A-Chip , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Humanos
12.
Opt Express ; 24(10): 10972-9, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27409919

RESUMO

We demonstrate a compact spectrometer system by using a gradient grating period guided-mode resonance filter-mounted on a linear photodetector array-that exhibits spatially dependent resonance characteristics; a specific incident wavelength is reflected such that the underlying array pixels measure minimum intensity. A precalibrated transmission efficiency matrix is used to determine each pixel's transmission efficiency for specific wavelengths. Unknown spectral information can be calculated from the measured intensity. Grating periods of 250-388 nm in 2-nm increments are used in each 100-cycle period. Device length is 2.23 mm. Spectral range of 506-700 nm is measurable with 1-nm resolution.

13.
Analyst ; 141(13): 4189-95, 2016 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-27170945

RESUMO

We present an integrated microfluidic system consisting of a label-free biosensor of a guided-mode resonance filter (GMRF) and a microfluidic channel with a micropost filter. The GMRF was fabricated through replica molding using an ultraviolet-curable polymer and a plastic substrate. An array of microposts (a diameter and height of 26.5 and 56 µm, respectively, and a spacing between 7.5 and 9.5 µm), fabricated on a silicon substrate through photolithography, was used as the filter. A double-sided tape was used to laminate the GMRF and a microfluidic chip such that the integrated device provides two functions: filtration of the cell debris and quantification of the in-cell protein concentration. By measuring the changes in the resonant wavelength from the GMRF, the detection of ß-actin in an unprocessed lysed cell sample was demonstrated; the cell debris was separated using the micropost filter to prevent false measurement.


Assuntos
Técnicas Biossensoriais , Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação , Proteínas/análise , Actinas/análise , Desenho de Equipamento , Filtração , Células HEK293 , Humanos , Silício
14.
Opt Express ; 24(3): 2954-64, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26906862

RESUMO

This study demonstrates a photonic crystal micropost (PCMP) substrate for microarray applications. The substrate comprises an array of circular MPs with a PC on top of these MPs. This substrate enables biomolecule-containing droplets to form a composite contact upon deposition, thus allowing biomolecules to be attached on only the MPs, forming spots. When the device (PC) is excited on resonance, the electric field intensity is enhanced on only the top surface of the MPs. This enables the fluorescence intensities to be enhanced up to 5.50x; principally, this enhancement does not engender an increase in the background (intensity outside MP or spots) and noise intensities. The PCMP substrate enhances the spot intensity and minimizes the background intensity, enabling the detection of lower concentration analytes.

15.
Opt Lett ; 40(5): 733-5, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25723419

RESUMO

In this Letter, we demonstrate that fluorescence detection by using surface-bound fluorescent molecules can be enhanced by coupling the fluorescence emission with dually polarized resonant modes of a photonic crystal (PC) substrate. The PC was fabricated through nanoreplica molding by using a plastic substrate. It was designed such that the transverse magnetic (TM)- and transverse electric (TE)-polarized resonance coincided at a specific combination of the incident angle and the illumination wavelength. During excitation, the nonpolarized emission from cyanine-5 was simultaneously coupled with the TE and TM resonant modes and reradiated into the detection instrument, increasing the fluorescence collection efficiency and thus, enhancing the fluorescence detection.


Assuntos
Fótons , Espectrometria de Fluorescência/métodos , Carbocianinas/química , Fibras Ópticas , Espectrometria de Fluorescência/instrumentação , Propriedades de Superfície
16.
Appl Opt ; 52(22): 5545-51, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23913077

RESUMO

A polymeric SU8 inverted-rib waveguide Bragg grating filter fabricated using reactive ion etching (RIE) and solvent assisted microcontact molding (SAMIM) is presented. SAMIM is one kind of soft lithography. The technique is unique in that a composite hard-polydimethysiloxane/polydimethysiloxane stamp is used to transfer the grating pattern onto an inverted SU8 rib waveguide system. The composite grating stamp can be used repeatedly several times without degradation. Using this stamp and inverter-rib waveguide structure, the Bragg grating filter fabrication can be significantly simplified. The experiment result shows an attenuation dip in the transmission spectra, with a value of -7 dBm at 1550 nm for a grating with a period of 0.492 µm on an inverted-rib waveguide with 6.6 µm width and 4 µm height.


Assuntos
Compostos de Epóxi/química , Filtração/instrumentação , Polímeros/química , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Propriedades de Superfície
17.
Opt Lett ; 37(13): 2565-7, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22743456

RESUMO

A laser line-scanning instrument was developed to optimize the near-field enhancement capability of a one-dimensional photonic crystal (PC) for excitation of surface-bound fluorophores. The excitation laser beam is shaped into an 8 µm × 1 mm line that is focused along the direction of the PC grating, while remaining collimated perpendicular to the grating. Such a beam configuration offers high excitation power density while simultaneously providing high resonant coupling efficiency from the laser to the PC surface. Using a panel of 21 immunofluorescence assays on the PC surface in a microarray format, the approach achieves an enhancement factor as high as 90-fold between on-resonance and off-resonance illumination. The instrument provides a capability for sensitive and inexpensive analysis of cancer biomarkers in clinical applications.


Assuntos
Fótons , Espectrometria de Fluorescência/instrumentação , Biomarcadores Tumorais/análise , Nanoestruturas , Análise Serial de Proteínas , Propriedades de Superfície
18.
Anal Chem ; 84(2): 1126-33, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22148758

RESUMO

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20-99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1-41 pg/mL), resulting in a three-log range of quantitative detection.


Assuntos
Anticorpos Imobilizados/química , Biomarcadores Tumorais/análise , Técnicas Biossensoriais , Neoplasias/metabolismo , Fótons , Quartzo , Anticorpos Imobilizados/metabolismo , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoensaio , Lasers , Neoplasias/imunologia , Análise Serial de Proteínas , Espectrometria de Fluorescência , Propriedades de Superfície
19.
Opt Express ; 19(23): 23327-40, 2011 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-22109210

RESUMO

By combining photonic crystal label-free biosensor imaging with photonic crystal enhanced fluorescence, it is possible to selectively enhance the fluorescence emission from regions of the PC surface based upon the density of immobilized capture molecules. A label-free image of the capture molecules enables determination of optimal coupling conditions of the laser used for fluorescence imaging of the photonic crystal surface on a pixel-by-pixel basis, allowing maximization of fluorescence enhancement factor from regions incorporating a biomolecule capture spot and minimization of background autofluorescence from areas between capture spots. This capability significantly improves the contrast of enhanced fluorescent images, and when applied to an antibody protein microarray, provides a substantial advantage over conventional fluorescence microscopy. Using the new approach, we demonstrate detection limits as low as 0.97 pg/ml for a representative protein biomarker in buffer.


Assuntos
Bioensaio/métodos , Biomarcadores/análise , Técnicas Biossensoriais/métodos , Fótons , Simulação por Computador , Cristalização , Ensaio de Imunoadsorção Enzimática , Fluorescência , Humanos , Microscopia , Coloração e Rotulagem , Fator de Necrose Tumoral alfa/análise
20.
Anal Chem ; 83(4): 1425-30, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21250635

RESUMO

We report on the use of photonic crystal surfaces as a high-sensitivity platform for detection of a panel of cancer biomarkers in a protein microarray format. The photonic crystal surface is designed to provide an optical resonance at the excitation wavelength of cyanine-5 (Cy5), thus providing an increase in fluorescent intensity for Cy5-labeled analytes measured with a confocal microarray scanner, compared to a glass surface. The sandwich enzyme-linked immunosorbent assay (ELISA) is undertaken on a microarray platform to undertake a simultaneous, multiplex analysis of 24 antigens on a single chip. Our results show that the resonant excitation effect increases the signal-to-noise ratio by 3.8- to 6.6-fold, resulting in a decrease in detection limits of 6-89%, with the exact enhancement dependent upon the antibody-antigen interaction. Dose-response characterization of the photonic crystal antibody microarrays shows the capability to detect common cancer biomarkers in the <2 pg/mL concentration range within a mixed sample.


Assuntos
Biomarcadores Tumorais/análise , Fótons , Análise Serial de Proteínas/métodos , Espectrometria de Fluorescência/métodos , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Biomarcadores Tumorais/imunologia , Calibragem , Imunoensaio , Limite de Detecção , Impressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA