Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Hum Kinet ; 83: 29-37, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36157958

RESUMO

The purpose of this study was to investigate the effects of stiffness regulated by landing styles on drop jump performance. Twenty-four male lacrosse athletes performed drop jumps with stiff (ST), self-selected (SS), and soft (SF) landing from a 0.42 m box. Leg stiffness, ground contact time, depth, jump height, maximum ground reaction force (GRF), GRF at the start of the propulsive phase, mean power, peak power, and the reactive strength index (RSI) were calculated. The results showed that jump height and the RSI had strong correlations to power production in all drop jump styles. Power would be a key factor to overall athletic performance. Repeated measures ANOVA showed significant differences (p < 0.05) in all variables among the three styles. Drop jumps with SS landing had comparable jump height to drop jumps with SF landing and power output to drop jumps with ST landing. Drop jumps with ST landing had significantly lower jump height, but higher GRF, power, and the RSI compared to drop jumps with SF landing. In drop jump testing, drop jumps with SS landing should be used if power and jump height were the major concerns; if the RSI was the major concern, drop jumps with ST landing should be used. Training with drop jumps, one of the main objectives should be increasing power output due to its significant correlation to jump height and the RSI in all conditions.

2.
Sensors (Basel) ; 22(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35214368

RESUMO

Lactate measurement is important in the fields of sports and medicine. Lactate accumulation can seriously affect an athlete's performance. The most common problem caused by lactate accumulation in athletes is muscle soreness due to excessive exercise. Moreover, from a medical viewpoint, lactate is one of the main prognostic factors of sepsis. Currently, blood sampling is the most common approach to lactate measurement for lactate sensing, and continuous measurement is not available. In this study, a low-cost continuous lactate monitoring system (CLMS) is developed based on a percutaneous microneedle array that uses a three-electrode lactate sensor. The working electrode has an area of 10 mm × 6 mm, including a 3 × 3 array of stainless-steel microneedles. The length, width, and thickness of each needle are 1 mm, 0.44 mm, and 0.03 mm, respectively. The working electrode is then plated with gold, polyaniline, lactate enzyme, Nafion, and Poly(2-hydroxyethyl methacrylate) (poly HEMA). The reference electrode is a 2 × 1 array covered with AgCl, and the counter electrode is a 2 × 1 array plated with gold. The sensor is incorporated into the CLMS and connected to a smartphone application and the cloud. The CLMS was tested on 40 human subjects who rode indoor bicycles, starting at 100 W and increasing in steps of 25 W at intervals of 5 min until exhaustion. The data acquired from the app connected to the CLMS were analyzed to determine the subjects' lactate response to exercise and the feasibility of assessing exercise performance and training exercise intensity by using the proposed system.


Assuntos
Técnicas Biossensoriais , Ácido Láctico , Eletrodos , Ouro , Humanos , Monitorização Fisiológica
3.
Sci Rep ; 10(1): 10602, 2020 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-32606394

RESUMO

A strontium (Sr)-doped hydroxyapatite-like coating was deposited on α-Ti alloy via the growing integration layer (GIL) method at various applied voltages. We added 0.03 M strontium hydroxide (Sr(OH)2·8H2O) to a solution containing calcium acetate and sodium dihydrogen phosphate to produce Sr-doped hydroxyapatite (Sr-HA) coatings. The scanning electron microscope (SEM) images of these coatings showed that all various features, such as average pore size, coating thickness, micro-hardness, and roughness, were similar to those of HA. As the voltage increased from 250 to 300 V, the amount of micro cracks decreased, and there were eliminated at 350 V. The SEM images also showed that the Sr-HA coatings were closely integrated with the alloy: without any gaps between the oxide layers and the alloy. In addition, energy-dispersive X-ray spectroscopy verified the Sr integration from the bottom up. X-ray diffraction patterns confirmed Sr-HA formation instead of calcium phosphate, even at the lowest voltage of 250 V. The value of Ecorr increased by 6.6% after raising the voltage from 250 to 350 V. The electrochemical impedance spectroscopy analysis confirmed that the adequate corrosion resistance of Sr-HA coatings, especially at the highest voltage of 350 V. In addition, the GIL treatment increased the layer resistance measured by Rp/Rc. Optimally, the GIL method used the highest voltage of 350 V to produce higher quality of Sr-HA-rich coatings.

4.
Mater Sci Eng C Mater Biol Appl ; 76: 1216-1223, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28482488

RESUMO

This paper demonstrates Ca-P-rich bio-ceramic and hydroxyapatite (HA) coatings formed directly from the solution of calcium acetate (CA) and sodium dihydrogen phosphate (SDP) on α-Ti-alloy substrates by Growing Integration Layer (GIL) technology under DC power supply. The composition of the α-Ti-alloy was Ti7Cu5Sn. The GIL coated films formed in 30min time with different voltages applied had porous and rough ceramic surfaces. They consisted mostly of various oxides like rutile, anatase, and calcium phosphates (including hydroxyapatite) that reduce corrosion rate and increase biocompatibility. An important feature was the reduction of Cu at the surfaces of the alloys. Furthermore, along with the applied voltage, the content of HA, the size of micro-pores, and hardness all increased, while the number of micro-pores in the ceramic membrane got reduced. The potential, current and resistance of corrosion were identified by potentiodynamic (PD) polarization and electrochemical impedance spectroscopy (EIS). The higher applied voltage improved the surface quality, HA formation rate, and the anti-corrosion behavior. Consequently, the samples - prepared at 350V and surface current density of 3A/cm2 - possessed the most compact HA films, and also had the best corrosion resistance - in 0.9wt% NaCl solution at 37±1°C.


Assuntos
Cerâmica , Ligas , Fosfatos de Cálcio , Corrosão , Durapatita , Teste de Materiais , Propriedades de Superfície , Titânio
5.
Int J Med Sci ; 14(3): 231-239, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28367083

RESUMO

Globally, the proportion of older adults is increasing. Older people face chronic conditions such as sarcopenia and functional decline, which are often associated with disability and frailty. Proteomics assay of potential serum biomarkers of frailty in older adults. Older adults were divided into non-frail and frail groups (n = 6 each; 3 males in each group) in accordance with the Chinese-Canadian Study of Health and Aging Clinical Frailty Scale. Adults were measured for grip power and the 6-min walk test for physical activity, and venous blood was sampled after adults fasted for 8 h. Ultra-high-performance liquid chromatography-tandem mass spectrometry was used for proteomics assay. The groups were compared for levels of biomarkers by t test and Pearson correlation analysis. Non-frail and frail subjects had mean age 77.5±0.4 and 77.7±1.6 years, mean height 160.5±1.3 and 156.6±2.9 cm and mean weight 62.5±1.2 and 62.8±2.9 kg, respectively. Physical activity level was lower for frail than non-frail subjects (grip power: 13.8±0.4 vs 26.1±1.2 kg; 6-min walk test: 215.2±17.2 vs 438.3±17.2 m). Among 226 proteins detected, for 31, serum levels were significantly higher for frail than non-frail subjects; serum levels of Ig kappa chain V-III region WOL, COX7A2, and albumin were lower. The serum levels of ANGT, KG and AT were 2.05-, 1.76- and 2.22-fold lower (all p < 0.05; Figure 1A, 2A and 3A) for non-frail than frail subjects and were highly correlated with grip power (Figure 1B, 2B and 3B). Our study found that ANGT, KG and AT levels are known to increase with aging, so degenerated vascular function might be associated with frailty. In total, 226 proteins were revealed proteomics assay; levels of angiotensinogen (ANGT), kininogen-1 (KG) and antithrombin III (AT) were higher in frail than non-frail subjects (11.26±2.21 vs 5.09±0.74; 18.42±1.36 vs 11.64±1.36; 22.23±1.64 vs 9.52±0.95, respectively, p < 0.05). These 3 factors were highly correlated with grip power (p < 0.05), with higher correlations between grip power and serum levels of ANGT (r = -0.89), KG (r = -0.90), and AT (r = -0.84). In conclusion, this is the first study to demonstrate a serum proteomic profile characteristic of frailty in older adults. Serum ANGT, KG and AT levels could be potential biomarkers for monitoring the development and progression of frailty in older adults.


Assuntos
Envelhecimento/sangue , Biomarcadores/sangue , Idoso Fragilizado , Proteômica , Sarcopenia/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/patologia , Angiotensinogênio/sangue , Antitrombina III/metabolismo , Exercício Físico , Feminino , Força da Mão/fisiologia , Humanos , Cininogênios/sangue , Masculino , Sarcopenia/fisiopatologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-28077934

RESUMO

BACKGROUND: Myostatin negatively regulates muscle growth, and its inhibition by suitable proteins can increase muscle bulk and exercise performance. However, the reference values of serum myostatin in athletes performing strength training are still lacking. METHODS: A cross-sectional study recruiting28 male collegiate athletes performing strength training and 29 age-matched normal controls was conducted. The serum concentration of myostatin and insulin-like growth factor 1 (IGF-1), grip strength, and body composition were the main outcome measures. We used regression models to analyze the correlation between serum markers and the physiological parameters. The athlete group had greater height, weight, body mass index (BMI), fat mass percentage, fat-free mass, muscle mass, waist girth, grip strength, and estimated daily energy expenditure. RESULTS: The IGF-1 concentration was higher in the athlete group (324 ± 80 vs. 263 ± 134 ng/ml), but the myostatin levels did not differ (12.1 ± 3.7 vs. 12.4 ± 3.5 ng/ml). The reference value for IGF-1 among the healthy young males was 293 ± 114 ng/ml, correlated with age and height; the value for myostatin was 12.3 ± 3.6 ng/ml, correlated negatively with BMI, fat mass percentage, and waist girth after adjustment for age. CONCLUSION: Myostatin level is negatively related to fat percentage, and serum IGF-1 is positively related to height. The reference values could provide a basis for future doping-related study.


Assuntos
Biomarcadores/sangue , Dopagem Esportivo , Fator de Crescimento Insulin-Like I/metabolismo , Miostatina/sangue , Treinamento Resistido , Composição Corporal , Estudos Transversais , Humanos , Masculino , Valores de Referência , Adulto Jovem
7.
Hum Mov Sci ; 27(1): 142-53, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17935809

RESUMO

The purpose of this study was to compare the postural sway profiles of 9/10-year-old children with developmental coordination disorder and balance problems (DCD-BP, n=64) with those of non-DCD children (n=71). We measured center of pressure excursions in conditions with and without vision for 30s while standing still on the dominant leg, the non-dominant leg, or both legs. Sway area, total path length, and Romberg's quotient were analyzed. Most measures differed significantly between groups, except sway area when the children stood with vision on either the dominant leg or both legs. When standing on the dominant leg or both legs, DCD-BP children demonstrated greater total path length in all conditions and a greater sway area in without-vision conditions. DCD-BP children showed more difficulty standing on the non-dominant leg with eyes both open and closed. While boys showed results similar to the total group, the girls with DCD-BP only exhibited significant differences in three conditions with eyes closed, but not with eyes open. Analysis of Romberg's coefficient also indicated that children with DCD-BP did not over-rely on visual information.


Assuntos
Cinestesia/fisiologia , Transtornos das Habilidades Motoras/fisiopatologia , Equilíbrio Postural/fisiologia , Postura/fisiologia , Desempenho Psicomotor/fisiologia , Adulto , Fenômenos Biomecânicos , Criança , Feminino , Humanos , Masculino , Privação Sensorial/fisiologia , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA