Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 118(5): 1497-1506, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220069

RESUMO

PURPOSE: The optimal sequencing of local and systemic therapy for oligometastatic cancer has not been established. This study retrospectively compared progression-free survival (PFS), overall survival (OS), and SABR-related toxicity between upfront versus delay of systemic treatment until progression in patients in the SABR-5 trial. METHODS AND MATERIALS: The single-arm phase 2 SABR-5 trial accrued patients with up to 5 oligometastases across SABR-5 between November 2016 and July 2020. Patients received SABR to all lesions. Two cohorts were retrospectively identified: those receiving upfront systemic treatment along with SABR and those for whom systemic treatment was delayed until disease progression. Patients treated for oligoprogression were excluded. Propensity score analysis with overlap weighting balanced baseline characteristics of cohorts. Bootstrap sampling and Cox regression models estimated the association of delayed systemic treatment with PFS, OS, and grade ≥2 toxicity. RESULTS: A total of 319 patients with oligometastases underwent treatment on SABR-5, including 121 (38%) and 198 (62%) who received upfront and delayed systemic treatment, respectively. In the weighted sample, prostate cancer was the most common primary tumor histology (48%) followed by colorectal (18%), breast (13%), and lung (4%). Most patients (93%) were treated for 1 to 2 metastases. The median follow-up time was 34 months (IQR, 24-45). Delayed systemic treatment was associated with shorter PFS (hazard ratio [HR], 1.56; 95% CI, 1.15-2.13; P = .005) but similar OS (HR, 0.90; 95% CI, 0.51-1.59; P = .65) compared with upfront systemic treatment. Risk of grade 2 or higher SABR-related toxicity was reduced with delayed systemic treatment (odds ratio, 0.35; 95% CI, 0.15-0.70; P < .001). CONCLUSIONS: Delayed systemic treatment is associated with shorter PFS without reduction in OS and with reduced SABR-related toxicity and may be a favorable option for select patients seeking to avoid initial systemic treatment. Efforts should continue to accrue patients to histology-specific trials examining a delayed systemic treatment approach.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Estudos Retrospectivos , Neoplasias da Próstata/patologia , Intervalo Livre de Progressão , Radiocirurgia/métodos
2.
Radiother Oncol ; 182: 109576, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36822355

RESUMO

BACKGROUND AND PURPOSE: Stereotactic ablative radiotherapy (SABR) for oligometastases may improve survival, however concerns about safety remain. To mitigate risk of toxicity, target coverage was sacrificed to prioritize organs-at-risk (OARs) during SABR planning in the population-based SABR-5 trial. This study evaluated the effect of this practice on dosimetry, local recurrence (LR), and progression-free survival (PFS). METHODS: This single-arm phase II trial included patients with up to 5 oligometastases between November 2016 and July 2020. Theprotocol-specified planning objective was to cover 95 % of the planning target volume (PTV) with 100 % of the prescribed dose, however PTV coverage was reduced as needed to meet OAR constraints. This trade-off was measured using the coverage compromise index (CCI), computed as minimum dose received by the hottest 99 % of the PTV (D99) divided by the prescription dose. Under-coverage was defined as CCI < 0.90. The potential association between CCI and outcomes was evaluated. RESULTS: 549 lesions from 381 patients were assessed. Mean CCI was 0.88 (95 % confidence interval [CI], 0.86-0.89), and 196 (36 %) lesions were under-covered. The highest mean CCI (0.95; 95 %CI, 0.93-0.97) was in non-spine bone lesions (n = 116), while the lowest mean CCI (0.71; 95 % CI, 0.69-0.73) was in spine lesions (n = 104). On multivariable analysis, under-coverage did not predict for worse LR (HR 0.48, p = 0.37) or PFS (HR 1.24, p = 0.38). Largest lesion diameter, colorectal and 'other' (non-prostate, breast, or lung) primary predicted for worse LR. Largest lesion diameter, synchronous tumor treatment, short disease free interval, state of oligoprogression, initiation or change in systemic treatment, and a high PTV Dmax were significantly associated with PFS. CONCLUSION: PTV under-coverage was not associated with worse LR or PFS in this large, population-based phase II trial. Combined with low toxicity rates, this study supports the practice of prioritizing OAR constraints during oligometastatic SABR planning.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Humanos , Órgãos em Risco/patologia , Neoplasias Pulmonares/patologia , Pulmão/patologia , Intervalo Livre de Progressão , Radiocirurgia/efeitos adversos
3.
JAMA Oncol ; 8(11): 1644-1650, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36173619

RESUMO

Importance: After the publication of the landmark SABR-COMET trial, concerns arose regarding high-grade toxic effects of treatment with stereotactic ablative body radiotherapy (SABR) for oligometastases. Objective: To document toxic effects of treatment with SABR in a large cohort from a population-based, provincial cancer program. Design, Setting, and Participants: From November 2016 to July 2020, 381 patients across all 6 cancer centers in British Columbia were treated in this single-arm, phase 2 trial of treatment with SABR for patients with oligometastatic or oligoprogressive disease. During this period, patients were only eligible to receive treatment with SABR in these settings in trials within British Columbia; therefore, this analysis is population based, with resultant minimal selection bias compared with previously published SABR series. Interventions: Stereotactic ablative body radiotherapy to up to 5 metastases. Main Outcomes and Measures: Rate of grade 2, 3, 4, and 5 toxic effects associated with SABR. Findings: Among 381 participants (122 women [32%]), the mean (SD; range) age was 68 (11.1; 30-97) years, and the median (range) follow-up was 25 (1-54) months. The most common histological findings were prostate cancer (123 [32%]), colorectal cancer (63 [17%]), breast cancer (42 [11%]), and lung cancer (33 [9%]). The number of SABR-treated sites were 1 (263 [69%]), 2 (82 [22%]), and 3 or more (36 [10%]). The most common sites of SABR were lung (188 [34%]), nonspine bone (136 [25%]), spine (85 [16%]), lymph nodes (78 [14%]), liver (29 [5%]), and adrenal (15 [3%]). Rates of grade 2, 3, 4, and 5 toxic effects associated with SABR (based on the highest-grade toxic effect per patient) were 14.2%; (95% CI, 10.7%-17.7%), 4.2% (95% CI, 2.2%-6.2%), 0%, and 0.3% (95% CI, 0%-0.8%), respectively. The cumulative incidence of grade 2 or higher toxic effects associated with SABR at year 2 by Kaplan-Meier analysis was 8%, and for grade 3 or higher, 4%. Conclusions and Relevance: This single-arm, phase 2 clinical trial found that the incidence of grade 3 or higher SABR toxic effects in this population-based study was less than 5%. Furthermore, the rates of grade 2 or higher toxic effects (18.6%) were lower than previously published for SABR-COMET (29%). These results suggest that SABR treatment for oligometastases has acceptable rates of toxic effects and potentially support further enrollment in randomized phase 3 clinical trials. Trial Registration: ClinicalTrials.gov Identifier: NCT02933242.


Assuntos
Neoplasias Pulmonares , Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias Pulmonares/patologia , Fracionamento da Dose de Radiação , Estimativa de Kaplan-Meier
4.
Int J Radiat Oncol Biol Phys ; 114(5): 1016-1021, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35031340

RESUMO

PURPOSE: SABR may improve survival in patients with oligometastases, but for some lesions, safe delivery of SABR may require a reduction in delivered dose or target coverage. This study assessed the association between target coverage compromise and oncologic and survival outcomes. METHODS AND MATERIALS: Patients with a controlled primary malignancy and 1 to 5 oligometastases were randomized (1:2) between standard of care (SOC) treatment and SOC plus SABR. In patients receiving SABR, the target dose coverage was reduced to meet organ at risk (OAR) constraints, if necessary. The D99 value (minimum dose received by the hottest 99% of the planning target volume [PTV]) was used as a measure of PTV coverage for each treatment plan, and the relationship between the coverage compromise index (CCI, defined as D99/prescription dose) and patient outcomes was assessed. RESULTS: Sixty-two patients in the SABR arm had dosimetric information available and a total of 109 lesions were evaluated. The mean CCI per lesion was 0.96 (95% CI, 0.56-1.61). Of the 109 lesions evaluated, 29.4% (n = 32) required coverage compromise (CCI <0.9). Adrenal metastases required coverage compromise in 100% of analyzed lesions (n = 7). CCI was not significantly associated with lesional control, adverse events, overall survival (OS), or progression-free survival (PFS). CONCLUSIONS: Target compromise was required in a substantial minority of cases, but PTV coverage was not associated with OS, progression-free survival, or lesional control. This suggests that OAR constraints used for SABR treatments in the oligometastatic setting should continue to be prioritized during planning.


Assuntos
Radiocirurgia , Humanos , Radiocirurgia/métodos , Intervalo Livre de Progressão , Radiometria , Padrão de Cuidado , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Transfusion ; 61(10): 2906-2917, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34505291

RESUMO

BACKGROUND: This study utilized a population-based claims database to identify patients with beta-thalassemia and evaluate associations between transfusion burden, healthcare resource utilization (HCRU), and complications. STUDY DESIGN AND METHODS: Taiwan's National Health Insurance Research Database was used to identify patients with beta-thalassemia (ICD-10 D56.1) in 2016. Patients with a beta-thalassemia claim in 2016 were indexed into the study at their first claim on or after January 1, 2001 in the dataset through to December 31, 2016 and followed until the end of study. During the follow-up period, red blood cell transfusion (RBCT) units, HCRU, iron chelation therapy use, and beta-thalassemia-related complications incidence were recorded. Patients were grouped into transfusion burden severity cohorts based on average number of RBCT units per 12 weeks during follow-up: 0 RBCT units, >0 to <6 RBCT units (mild), ≥6 to <12 RBCT units (moderate), and ≥12 RBCT units (severe). RESULTS: A total of 2984 patients were included with mean follow-up of 6.95 years. Of these, 1616 (54.2%) patients had no claims for RBCT units, 1112 (37.3%) had claims for >0 to <6 RBCT units, 112 (3.8%) for ≥6 to <12 RBCT units, and 144 (4.8%) for ≥12 RBCT units per 12 weeks. Transfused patients had significantly more all-cause HCRU and iron chelation therapy compared with non-transfused patients during follow-up. Thalassemia-related HCRU and risk of liver, endocrine, cardiac, and renal complications were significantly and positively correlated with increases of RBCT units. DISCUSSION: Clinical and healthcare resource burden of patients with beta-thalassemia is closely related to transfusion burden.


Assuntos
Transfusão de Sangue , Talassemia beta/terapia , Adulto , Transfusão de Eritrócitos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde , Estudos Retrospectivos , Taiwan/epidemiologia , Adulto Jovem , Talassemia beta/epidemiologia
6.
Front Oncol ; 11: 626499, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34164335

RESUMO

PURPOSE: Deep learning-based auto-segmented contour (DC) models require high quality data for their development, and previous studies have typically used prospectively produced contours, which can be resource intensive and time consuming to obtain. The aim of this study was to investigate the feasibility of using retrospective peer-reviewed radiotherapy planning contours in the training and evaluation of DC models for lung stereotactic ablative radiotherapy (SABR). METHODS: Using commercial deep learning-based auto-segmentation software, DC models for lung SABR organs at risk (OAR) and gross tumor volume (GTV) were trained using a deep convolutional neural network and a median of 105 contours per structure model obtained from 160 publicly available CT scans and 50 peer-reviewed SABR planning 4D-CT scans from center A. DCs were generated for 50 additional planning CT scans from center A and 50 from center B, and compared with the clinical contours (CC) using the Dice Similarity Coefficient (DSC) and 95% Hausdorff distance (HD). RESULTS: Comparing DCs to CCs, the mean DSC and 95% HD were 0.93 and 2.85mm for aorta, 0.81 and 3.32mm for esophagus, 0.95 and 5.09mm for heart, 0.98 and 2.99mm for bilateral lung, 0.52 and 7.08mm for bilateral brachial plexus, 0.82 and 4.23mm for proximal bronchial tree, 0.90 and 1.62mm for spinal cord, 0.91 and 2.27mm for trachea, and 0.71 and 5.23mm for GTV. DC to CC comparisons of center A and center B were similar for all OAR structures. CONCLUSIONS: The DCs developed with retrospective peer-reviewed treatment contours approximated CCs for the majority of OARs, including on an external dataset. DCs for structures with more variability tended to be less accurate and likely require using a larger number of training cases or novel training approaches to improve performance. Developing DC models from existing radiotherapy planning contours appears feasible and warrants further clinical workflow testing.

7.
Radiat Oncol ; 16(1): 101, 2021 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-34103062

RESUMO

PURPOSE: We recently described the validation of deep learning-based auto-segmented contour (DC) models for organs at risk (OAR) and clinical target volumes (CTV). In this study, we evaluate the performance of implemented DC models in the clinical radiotherapy (RT) planning workflow and report on user experience. METHODS AND MATERIALS: DC models were implemented at two cancer centers and used to generate OAR and CTVs for all patients undergoing RT for a central nervous system (CNS), head and neck (H&N), or prostate cancer. Radiation Therapists/Dosimetrists and Radiation Oncologists completed post-contouring surveys rating the degree of edits required for DCs (1 = minimal, 5 = significant) and overall DC satisfaction (1 = poor, 5 = high). Unedited DCs were compared to the edited treatment approved contours using Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD). RESULTS: Between September 19, 2019 and March 6, 2020, DCs were generated on approximately 551 eligible cases. 203 surveys were collected on 27 CNS, 54 H&N, and 93 prostate RT plans, resulting in an overall survey compliance rate of 32%. The majority of OAR DCs required minimal edits subjectively (mean editing score ≤ 2) and objectively (mean DSC and 95% HD was ≥ 0.90 and ≤ 2.0 mm). Mean OAR satisfaction score was 4.1 for CNS, 4.4 for H&N, and 4.6 for prostate structures. Overall CTV satisfaction score (n = 25), which encompassed the prostate, seminal vesicles, and neck lymph node volumes, was 4.1. CONCLUSIONS: Previously validated OAR DC models for CNS, H&N, and prostate RT planning required minimal subjective and objective edits and resulted in a positive user experience, although low survey compliance was a concern. CTV DC model evaluation was even more limited, but high user satisfaction suggests that they may have served as appropriate starting points for patient specific edits.


Assuntos
Neoplasias do Sistema Nervoso Central/radioterapia , Aprendizado Profundo , Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/patologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Implementação de Plano de Saúde , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Prognóstico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Fluxo de Trabalho
8.
J Appl Clin Med Phys ; 22(6): 50-59, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34028969

RESUMO

PURPOSE: To assess dosimetric properties and identify required updates to commonly used protocols (including use of film and ionization chamber) pertaining to a clinical linac configured into FLASH (ultra-high dose rate) electron mode. METHODS: An 18MV photon beam of a Varian iX linac was converted to FLASH electron beam by replacing the target and the flattening filter with an electron scattering foil. The dose was prescribed by entering the MUs through the console. Fundamental beam properties, including energy, dose rate, dose reproducibility, field size, and dose rate dependence on the SAD, were examined in preparation for radiobiological experiments. Gafchromic EBT-XD film was evaluated for usability in measurements at ultra-high dose rates by comparing the measured dose to the inverse square model. Selected previously reported models of chamber efficiencies were fitted to measurements in a broad range of dose rates. RESULTS: The performance of the modified linac was found adequate for FLASH radiobiological experiments. With exception of the increase in the dose per MU on increase in the repetition rate, all fundamental beam properties proved to be in line with expectations developed with conventional linacs. The field size followed the theorem of similar triangles. The highest average dose rate (2 × 104  Gy/s) was found next to the internal monitor chamber, with the field size of FWHM = 1.5 cm. Independence of the dose readings on the dose rate (up to 2 × 104  Gy/s) was demonstrated for the EBT-XD film. A model of recombination in an ionization chamber was identified that provided good agreement with the measured chamber efficiencies for the average dose rates up to at least 2 × 103  Gy/s. CONCLUSION: Dosimetric measurements were performed to characterize a linac converted to FLASH dose rates. Gafchromic EBT-XD film and dose rate-corrected cc13 ionization chamber were demonstrated usable at FLASH dose rates.


Assuntos
Elétrons , Aceleradores de Partículas , Dosimetria Fotográfica , Humanos , Radiometria , Reprodutibilidade dos Testes
10.
Health Qual Life Outcomes ; 16(1): 216, 2018 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-30453981

RESUMO

BACKGROUND: Adherence to long-term chelation therapy in transfusion-dependent patients is critical to prevent iron overload-related complications. Once-daily deferasirox dispersible tablets (DT) have proven long-term efficacy and safety in patients ≥2 years old with chronic transfusional iron overload. However, barriers to optimal adherence remain, including palatability, preparation time, and requirements for fasting state. A new film-coated tablet (FCT) formulation was developed, swallowed once daily (whole/crushed) with/without a light meal. METHODS: The open-label, Phase II ECLIPSE study evaluated patient-reported outcomes (PROs) in transfusion-dependent thalassemia or lower-risk myelodysplastic syndromes patients randomized 1:1 to receive deferasirox DT or FCT over 24 weeks as a secondary outcome of the study. Three PRO questionnaires were developed to evaluate both deferasirox formulations: 1) Modified Satisfaction with Iron Chelation Therapy Questionnaire; 2) Palatability Questionnaire; 3) Gastrointestinal (GI) Symptom Diary. RESULTS: One hundred seventy three patients were enrolled; 87 received the FCT and 86 the DT formulation. FCT recipients consistently reported better adherence (easier to take medication, less bothered by time to prepare medication and waiting time before eating), greater satisfaction/preference (general satisfaction and with administration of medicine), and fewer concerns (less worry about not swallowing enough medication, fewer limitations in daily activities, less concern about side effects). FCT recipients reported no taste or aftertaste and could swallow all their medicine with an acceptable amount of liquid. GI summary scores were low for both formulations. CONCLUSIONS: These findings suggest a preference in favor of the deferasirox FCT formulation regardless of underlying disease or age group. Better patient satisfaction and adherence to chelation therapy may reduce iron overload-related complications. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02125877; registered April 26, 2014.


Assuntos
Desferroxamina/uso terapêutico , Quelantes de Ferro/uso terapêutico , Síndromes Mielodisplásicas/tratamento farmacológico , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Talassemia/tratamento farmacológico , Adulto , Transfusão de Sangue , Terapia por Quelação/métodos , Feminino , Humanos , Sobrecarga de Ferro/prevenção & controle , Masculino , Pessoa de Meia-Idade , Síndromes Mielodisplásicas/psicologia , Qualidade de Vida , Talassemia/psicologia
11.
Health Qual Life Outcomes ; 15(1): 129, 2017 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-28645270

RESUMO

BACKGROUND: Compliance, palatability, gastrointestinal (GI) symptom, and treatment satisfaction patient- and observer-reported outcome (PRO, ObsRO) measures were developed/modified for patients with transfusion-dependent anemias or myelodysplastic syndrome (MDS) requiring iron chelation therapy (ICT). METHODS: This qualitative cross-sectional observational study used grounded theory data collection and analysis methods and followed PRO/ObsRO development industry guidance. Patients and caregivers of patients with transfusion-dependent anemias or MDS were individually interviewed face-to-face to cognitively debrief the Compliance, Palatability, GI Symptom Diary, and Modified Satisfaction with Iron Chelation Therapy (SICT) instruments presented electronically. Interviews were conducted in sets. Interviews began open-endedly to spontaneously elicit ICT experiences. Item modifications were debriefed during the later interviews. Interviews were audio recorded, transcribed, and coded. Data was analyzed using ATLAS.ti qualitative research software. RESULTS: Twenty-one interviews were completed (Set 1: 5 patients, 6 caregivers; Set 2: 6 patients, 4 caregivers) in 6 US cities. Mean age was 43 years for patients and 9 years for children of caregivers. Conditions requiring ICT use across groups included transfusion-dependent anemias (85.7%) and MDS (14.3%). Concepts spontaneously reported were consistent with instruments debriefed. Interview analysis resulted in PRO and ObsRO versions of each instrument: Compliance (2 items), Palatability (4 items), GI Symptom Diary (6 items), and Modified SICT (PRO = 13, ObsRO = 17 items). CONCLUSION: Qualitative research data from cognitive interviews supports the content validity and relevance of the instruments developed/modified. Quantitative validation of these PRO and ObsRO measures is needed testing for validity, reliability, and responsiveness for future research use with new formulations of oral ICT.


Assuntos
Cuidadores/psicologia , Terapia por Quelação/psicologia , Ferro , Inquéritos e Questionários , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Estudos Transversais , Feminino , Teoria Fundamentada , Humanos , Quelantes de Ferro/uso terapêutico , Masculino , Pessoa de Meia-Idade , Síndromes Mielodisplásicas/terapia , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados da Assistência ao Paciente , Satisfação do Paciente , Pesquisa Qualitativa , Qualidade de Vida , Reprodutibilidade dos Testes , Adulto Jovem
12.
Am J Hematol ; 92(5): 420-428, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28142202

RESUMO

Once-daily deferasirox dispersible tablets (DT) have a well-defined safety and efficacy profile and, compared with parenteral deferoxamine, provide greater patient adherence, satisfaction, and quality of life. However, barriers still exist to optimal adherence, including gastrointestinal tolerability and palatability, leading to development of a new film-coated tablet (FCT) formulation that can be swallowed with a light meal, without the need to disperse into a suspension prior to consumption. The randomized, open-label, phase II ECLIPSE study evaluated the safety of deferasirox DT and FCT formulations over 24 weeks in chelation-naïve or pre-treated patients aged ≥10 years, with transfusion-dependent thalassemia or IPSS-R very-low-, low-, or intermediate-risk myelodysplastic syndromes. One hundred seventy-three patients were randomized 1:1 to DT (n = 86) or FCT (n = 87). Adverse events (overall), consistent with the known deferasirox safety profile, were reported in similar proportions of patients for each formulation (DT 89.5%; FCT 89.7%), with a lower frequency of severe events observed in patients receiving FCT (19.5% vs. 25.6% DT). Laboratory parameters (serum creatinine, creatinine clearance, alanine aminotransferase, aspartate aminotransferase and urine protein/creatinine ratio) generally remained stable throughout the study. Patient-reported outcomes showed greater adherence and satisfaction, better palatability and fewer concerns with FCT than DT. Treatment compliance by pill count was higher with FCT (92.9%) than with DT (85.3%). This analysis suggests deferasirox FCT offers an improved formulation with enhanced patient satisfaction, which may improve adherence, thereby reducing frequency and severity of iron overload-related complications.


Assuntos
Benzoatos/administração & dosagem , Síndromes Mielodisplásicas/tratamento farmacológico , Talassemia/tratamento farmacológico , Triazóis/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Química Farmacêutica/métodos , Criança , Deferasirox , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Qualidade de Vida , Comprimidos com Revestimento Entérico/administração & dosagem , Comprimidos com Revestimento Entérico/efeitos adversos , Comprimidos com Revestimento Entérico/química , Adulto Jovem
13.
J Appl Clin Med Phys ; 16(6): 376­385, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699592

RESUMO

Flattening filter-free radiation beams have higher dose rates that significantly increase the ion recombination rate in an ion chamber's volume and lower the signal read by the chamber-electrometer pair. The ion collection efficiency correction (P(ion)) accounts for the loss of signal and subsequently changes dosimetric quantities when applied. We seek to characterize the changes to the percent depth dose, tissue maximum ratio, relative dose factor, absolute dose calibration, off-axis ratio, and the field width. We measured P(ion) with the two-voltage technique and represented P(ion) as a linear function of the signal strength. This linear fit allows us to correct measurement sets when we have only gathered the high voltage signal and to correct derived quantities. The changes to dosimetric quantities can be up to 1.5%. Charge recombination significantly affects percent depth dose, tissue maximum ratio, and off-axis ratio, but has minimal impact on the relative dose factor, absolute dose calibration, and field width.


Assuntos
Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Humanos , Íons/efeitos da radiação , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos
14.
Radiat Oncol ; 8: 67, 2013 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-23514439

RESUMO

BACKGROUND: To be less resource intensive, we developed a template-based breast IMRT technique (TB-IMRT). This study aims to compare resources and dose distribution between TB-IMRT and conventional breast radiation (CBR). METHODS: Twenty patients with early stage breast cancer were planned using CBR and TB-IMRT. Time to plan, coverage of volumes, dose to critical structures and treatment times were evaluated for CBR and TB-IMRT. Two sided-paired t tests were used. RESULTS: TB-IMRT planning time was less than CBR (14.0 vs 39.0 min, p < 0.001). Fifteen patients with CBR needed 18 MV, and 11 of these were planned successfully with TB-IMRT using 6 MV. TB-IMRT provided better homogeneity index (0.096 vs 0.124, p < 0.001) and conformity index (0.68 vs 0.59, p = 0.003). Dose to critical structures were comparable between TB-IMRT and CBR, and treatment times were also similar (6.0 vs 7.8 min, p = 0.13). CONCLUSIONS: TB- IMRT provides reduction of planning time and minimizes the use of high energy beams, while providing similar treatment times and equal plans compared to CBR. This technique permits efficient use of resources with a low learning curve, and can be done with existing equipment and personnel.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carga de Trabalho , Feminino , Humanos
15.
Biochem Biophys Res Commun ; 333(1): 194-9, 2005 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-15950190

RESUMO

SARS-CoV 3CL protease is essential for viral protein processing and is regarded as a good drug target to prevent SARS-CoV replication. In the present study, we established a high-throughput FRET technique for screening for anti-SARS-CoV 3CL protease drugs. Of a thousand existing drugs examined, hexachlorophene was identified as the most potent in inhibiting SARS-CoV 3CL protease. Further characterization showed that it was effective at micromolar concentrations (K(i) = 4 microM). The binding mode was competitive, and the inhibitory effect was dependent on preincubation time. Two other drugs, triclosan and nelfinavir, were about 10 times less potent. The structure-based search and biological evaluation of various hexachlorophene analogues were described. These analogues gave optimal inhibitory activity against SARS-CoV 3CL protease with IC(50) values ranging from 7.6 to 84.5 microM. Optimization of hexachlorophene analogues was shown to provide several active 3CL protease inhibitors that function as potential anti-SARS agents.


Assuntos
Desenho de Fármacos , Avaliação Pré-Clínica de Medicamentos/métodos , Transferência Ressonante de Energia de Fluorescência/métodos , Modelos Moleculares , Inibidores de Proteases/química , Mapeamento de Interação de Proteínas/métodos , Proteínas Virais/antagonistas & inibidores , Sítios de Ligação , Simulação por Computador , Proteases 3C de Coronavírus , Cisteína Endopeptidases , Endopeptidases/análise , Ativação Enzimática , Cinética , Inibidores de Proteases/análise , Ligação Proteica , Proteínas Virais/análise
16.
Phys Med Biol ; 50(5): 779-86, 2005 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-15798254

RESUMO

Extensive work has been performed to validate Monte Carlo models for both photon and electron beams under standard conditions. However, for large field electron beam therapy, Monte Carlo simulations have not been able to provide good agreement when compared to the measured dose distributions. Since the accuracy of the calculation relies heavily on the geometry parameters of the linear accelerator and the characteristics of the incident electron beam, it is crucial to have a complete comprehension of these independent factors. In this work, the electron focal spot size for a CL21EX linac with various energies (6, 9, 12 and 16 MeV) was measured with a slit camera composed of alternating lead and paper sheets. For all the energies investigated, the electron focal spot is found to be elliptical and has a full width at half maximum (FWHM) ranging from 1.69 mm to 2.24 mm. A shift with respect to the crosshair was associated with each measured focal spot. In addition, we present an improved result for the large field in-air profile by utilizing a proposed divergent beam model in conjunction with the experimental focal spot dimension. This model can potentially provide a solution to the Monte Carlo validation of large field electron beam therapy.


Assuntos
Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Elétrons , Método de Monte Carlo , Distribuição Normal , Fótons , Radiometria , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...