Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1306: 342612, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692793

RESUMO

Despite the widespread utilization of variable valence metals in electrochemistry, it is still a formidable challenge to enhance the valence conversion efficiency to achieve excellent catalytic activity without introducing heterophase elements. Herein, the in-situ precipitation of Co particles on Co2VO4 not only enhanced the concentration of oxygen vacancies (Ov) but also generated a greater number of low-valence metals, thereby enabling efficient reduction towards Hg(II). The electroanalysis results demonstrate that the sensitivity of Co/Co2VO4 towards Hg(II) was measured at an impressive value of 1987.74 µA µM-1 cm-2, significantly surpassing previously reported results. Further research reveals that Ov acted as the main adsorption site to capture Hg(II). The redox reactions of Co2+/Co3+ and V3+/V4+ played a synergistic role in the reduction of Hg(II), accompanied by the continuous supply of electrons from zero-valent Co to expedite the valence cycle. The Co/Co2VO4/GCE presented remarkable selectivity towards Hg(II), with excellent stability, reproducibility, and anti-interference capability. The electrode also exhibited minimal sensitivity fluctuations towards Hg(II) in real water samples, underscoring its practicality for environmental applications. This study elucidates the mechanism underlying the surface redox reaction of metal oxides facilitated by zero-valent metals, providing us with new strategies for further design of efficient and practical sensors.

2.
ACS Nano ; 18(20): 12808-12819, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38717026

RESUMO

Considerable progress has already been made in sweat sensors based on electrochemical methods to realize real-time monitoring of biomarkers. However, realizing long-term monitoring of multiple targets at the atomic level remains extremely challenging, in terms of designing stable solid contact (SC) interfaces and fully integrating multiple modules for large-scale applications of sweat sensors. Herein, a fully integrated wristwatch was designed using mass-manufactured sensor arrays based on hierarchical multilayer-pore cross-linked N-doped porous carbon coated by reduced graphene oxide (NPCs@rGO-950) microspheres with high hydrophobicity as core SC, and highly selective monitoring simultaneously for K+, Na+, and Ca2+ ions in human sweat was achieved, exhibiting near-Nernst responses almost without forming an interfacial water layer. Combined with computed tomography, solid-solid interface potential diffusion simulation results reveal extremely low interface diffusion potential and high interface capacitance (598 µF), ensuring the excellent potential stability, reversibility, repeatability, and selectivity of sensor arrays. The developed highly integrated-multiplexed wristwatch with multiple modules, including SC, sensor array, microfluidic chip, signal transduction, signal processing, and data visualization, achieved reliable real-time monitoring for K+, Na+, and Ca2+ ion concentrations in sweat. Ingenious material design, scalable sensor fabrication, and electrical integration of multimodule wearables lay the foundation for developing reliable sweat-sensing systems for health monitoring.


Assuntos
Eletrólitos , Grafite , Suor , Dispositivos Eletrônicos Vestíveis , Suor/química , Humanos , Grafite/química , Eletrólitos/química , Íons/análise , Cálcio/análise , Sódio/análise , Sódio/química , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Potássio/análise
3.
Anal Chem ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38749062

RESUMO

Solid contact (SC) calcium ion-selective electrodes (Ca2+-ISEs) have been widely applied in the analysis of water quality and body fluids by virtue of the unique advantages of easy operation and rapid response. However, the potential drift during the long-term stability test hinders their further practical applications. Designing novel redox SC layers with large capacitance and high hydrophobicity is a promising approach to stabilize the potential stability, meanwhile, exploring the transduction mechanism is also of great guiding significance for the precise design of SC layer materials. Herein, flower-like copper sulfide (CunS-50) composed of nanosheets is meticulously designed as the redox SC layer by modification with the surfactant (CTAB). The CunS-50-based Ca2+-ISE (CunS-50/Ca2+-ISE) demonstrates a near-Nernstian slope of 28.23 mV/dec for Ca2+ in a wide activity linear range of 10-7 to 10-1 M, with a low detection limit of 3.16 × 10-8 M. CunS-50/Ca2+-ISE possesses an extremely low potential drift of only 1.23 ± 0.13 µV/h in the long-term potential stability test. Notably, X-ray absorption fine-structure (XAFS) spectra and electrochemical experiments are adopted to elucidate the transduction mechanism that the lipophilic anion (TFPB-) participates in the redox reaction of CunS-50 at the solid-solid interface of ion-selective membrane (ISM) and redox inorganic SC layer (CunS-50), thereby promoting the generation of free electrons to accelerate ion-electron transduction. This work provides an in-depth comprehension of the transduction mechanism of the potentiometric response and an effective strategy for designing redox materials of ion-electron transduction triggered by lipophilic anions.

4.
Anal Chem ; 96(13): 5232-5241, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38447030

RESUMO

Although utilizing nanomaterial-modified electrodes for lead ion detection has achieved great success, most of them are carried out under acidic conditions and ignore the variation of Pb(II) speciation at different pH conditions, leading to the potential inaccuracy of Pb(II) detection in a neutral natural water environment. Thus, designing a novel catalyst with high accuracy for the detection of various forms of the total amount of Pb(II) (Pb2+ and Pb(OH)+) in neutral waters is significant. Herein, Pt nanoclusters (Pt NCs) were elaborately constructed and stabilized on the Co single-atom-doped g-C3N4 with abundant N vacancies (Pt NCs/VN-C3N4), which achieved the ultrasensitive detection (102.16 µM µA-1) of Pb(II) in neutral conditions. The dynamic simulation and theoretical calculations reveal that the parallel deposition of Pb2+ and Pb(OH)+ occurs on the electrode surface modified by Pt NCs/VN-C3N4, and the current peaks of Pb(II) are cocontributed by Pb2+ and Pb(OH)+ species. An "electron inverse" phenomenon in Pt NCs/VN-C3N4 from the VN-C3N4 substrate to Pt NCs endows Pt NCs in an electron-rich state, serving as active centers to promote rapid and efficient reduction for both Pb2+ and Pb(OH)+, facilitating the accurate detection of the total amount of Pb(II) in all forms in the actual water environment.

5.
Anal Chem ; 96(1): 179-187, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38100653

RESUMO

Achieving accurate detection of different speciations of heavy metal ions (HMIs) in an aqueous solution is an urgent problem due to the different bioavailabilities and physiological toxicity. Herein, we nominated a novel strategy to detect HCrO4- and Cr(OH)2+ at a trace level via the electrochemical sensitive surface constructed by Co3O4-rGO modified with amino and carboxyl groups, which revealed that the interactions between distinct functional groups and different oxygen-containing groups of target ions are conducive to the susceptible and anti-interference detection. The detection sensitivities of 19.46 counts µg-1 L for HCrO4- and 13.44 counts µg-1 L for Cr(OH)2+ were obtained under optimal conditions, while the limits of detection were 0.10 and 0.12 µg L-1, respectively. Satisfactory anti-interference and actual water sample analysis results were obtained. A series of advanced optical techniques like X-ray photoelectron spectroscopy, X-ray absorption near-edge structure technology, and density functional theory calculations under an electric field demonstrated that chemical interactions between groups contribute more to the fixation of target ions than electrical attraction alone. The presence of oxygen-containing groups distinct from simple ionic forms was a critical factor in the selectivity and anti-interference detection. Furthermore, the valence cycle of Co(II)/(III) synergistically boosted the detection performance. This research provides a promising tactic from the microscopic perspective of groups' interactions to accomplish the precise speciation analysis of HMIs in the water environment.

6.
ACS Sens ; 9(1): 415-423, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38154098

RESUMO

The high selectivity and fast ion response of all-solid sodium ion selective electrodes were widely applied in human sweat analysis. However, the potential drift due to insufficient interfacial capacitance leads to the deterioration of its stability and ultimately affects the potential accuracy of ion analysis. Designing a novel ion-electron transduction layer between the electrode and the ion selective membrane is an effective method to stabilize the interfacial potential. Herein, the SnS2-MoS2 heterojunction material was constructed by doping Sn in MoS2 nanosheets and used as the ion electron transduction layers of an all-solid sodium ion selective electrode for the first time, achieving the stable and efficient detection of Na+ ions. The proposed electrode exhibited a Nernst slope of 57.86 mV/dec for the detection of Na+ ions with a detection limit of 10-5.7 M in the activity range of 10-6-10-1 M. Via the electronic interaction at the heterojunction interfaces between SnS2 and MoS2 materials, the micro-nanostructure of the SnS2-MoS2 heterojunction was changed and SnS2-MoS2 as the ion-electron transduction layer acquired excellent capacitance (699 µF) and hydrophobicity (132°), resulting in a long-term potential stability of 1.37 µV/h. It was further proved that the large capacitance and high hydrophobicity of the ion-electron transduction layer are primary reasons for the excellent stability of the all-solid sodium ion selective electrode toward Na+ ions.


Assuntos
Eletrodos Seletivos de Íons , Molibdênio , Humanos , Elétrons , Capacitância Elétrica , Íons
7.
Chem Sci ; 14(36): 9678-9688, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37736653

RESUMO

Single-atom catalysts have been extensively utilized for electrocatalysis, in which electronic metal-support interactions are typically employed to stabilize single atoms. However, this neglects the metal-metal interactions of adjacent atoms, which are essential for the fine-tuning of selective sites. Herein, the high-loading of Ir single atoms (Ir SAs) (8.9 wt%) were adjacently accommodated into oxygen vacancy-rich Co3O4 nanosheets (Ir SAs/Co3O4). Electronic perturbations for both Ir single atoms and Co3O4 supports were observed under electronic metal-support and metal-metal interactions, thus generating Ir-O-Co/Ir units. Electrons were transferred from Co and Ir to O atoms, inducing the depletion of 3d/5d states in Co/Ir and the occupation of 2p states in O atoms to stabilize the Ir SAs. Moreover, the O atoms of Ir-O-Ir functioned as the main active sites for the electrocatalysis of As(iii), which reduced the energy barrier for the rate-determining step. This was due to the stronger electronic affinities for intermediates from reduction of As(iii), which were completely distinct from other coordinated O atoms of Co3O4 or IrO2. Consequently, the resultant Ir SAs/Co3O4 exhibited far more robust electrocatalytic activities than IrO2/Co3O4 and Co3O4 in the electrocatalysis of As(iii). Moreover, there was a strong orbital coupling effect between the coordinated O atoms of Ir SAs and the -OH of H3AsO3, thus exhibiting superior selectivity for As(iii) in contrast to other common heavy metal cations. This work offers useful insights into the rational design of intriguing SACs with high selectivity and stability for the electrocatalysis and electrochemical analysis of pollutants on an electronic level.

8.
Anal Chim Acta ; 1277: 341676, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37604614

RESUMO

The mutual interference in the sensing detection of heavy metal ions (HMIs) is considerably serious and complex. Besides, the co-existed ions may change the stripping peak intensity, shape and position of the target ion, which partly makes peak current analysis inaccurate. Herein, a promising approach of partial peak area analysis was proposed firstly to research the mutual interference. The interference between two species on their electrodeposition processes was investigated by simulating different kinetics parameters, including surface coverage, electro-adsorption, -desorption rate constant, etc. It was proved that the partial peak area is sensitive and regular to these interference kinetics parameters, which is favorable for distinctly identifying different interferences. Moreover, the applicability of the partial peak area analysis was verified on the experiments of Cu2+, As(III) interference at four sensing interfaces: glassy carbon electrode, gold electrode, Co3O4, and Fe2O3 nanoparticles modified electrodes. The interference behaviors between Cu2+ and As(III) relying on solid-solution interfaces were revealed and confirmed by physicochemical characterizations and kinetics simulations. This work proposes a new descriptor (partial peak area) to recognize the interference mechanism and provides a meaningful guidance for accurate detection of HMIs in actual water environment.

9.
J Hazard Mater ; 459: 132104, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37490798

RESUMO

The perplexity of double peaks in Pb(II) detections has been a threat to the reliability of Pb(II) electroanalysis results for a long term. For the complexity of electrode interfaces, rare studies were taken on mechanisms of Pb(II) double peaks through interfacial kinetics. In this work, analyses on experimental signals and interfacial simulations were working together to reveal that the generation of Pb(II) double peaks in Pb(II)-Cu(II) systems is the deposition of Pb(II) on Cu deposits occurring in parallel. By applying anode stripping voltammetry and cyclic voltammetry, a parallel deposition reaction was found to influence the shape of Pb(II) peaks, and the existence of the second peak was controlled through the adjustment of experimental conditions. A kinetic model was built to reveal the interference of electroanalysis signals caused by a parallel deposition reaction and simulations based on the model were combined with experiments to illustrate that double peaks of Pb(II) were caused by the parallel deposition on Cu(II) deposits. This work proposes another insight of Pb(II) double peaks from macroscale kinetics and pays more attention on the dynamic procedure of electroanalysis interfaces, which makes the study on environmental electroanalysis interface phenomena more clear and is enlightening to develop efficient electrical methods for pollutant monitoring.

10.
Chem Sci ; 14(11): 2960-2970, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36937602

RESUMO

Although the enhanced intrinsic activities of some nano-metal oxides are obtained by manufacturing oxygen vacancies (OVs), the effect of multiple roles of OVs is ambiguous. Herein, an interface catalytic regulation via electron rearrangement and hydroxyl radicals (˙OH) was proposed with the designed ZrO2 hollow sphere rich in OVs (Vo-rich ZrO2). Surprisingly, it was shown that the catalytic ability of Vo-rich ZrO2 was 9.9 times higher than that of ZrO2 with little OVs in electrochemical catalytic reduction of Pb(ii). It was found that the generation of Zr2+ and Zr3+ caused by OVs results in the rearrangement of abundant free electrons to facilitate the catalytic reaction rates. The longer bond length between Vo-rich ZrO2 and reactants, and the lower adsorption energy are beneficial for reactants to desorb, improving the conversion rates. Besides, the produced ˙OH were captured which were induced by OVs and trace divalent heavy metal ions in in situ electron paramagnetic resonance (EPR) experiments, contributing to lowering the energy barriers. This study not only revealed the enhanced interface catalytic effect of electron rearrangement and generated ˙OH triggered by OVs, but also provided unique insights into interface catalytic regulation on nano-metal oxides simulated by OVs.

11.
Anal Chem ; 95(7): 3666-3674, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36656141

RESUMO

Traditional nanomodified electrodes have made great achievements in electrochemical stripping voltammetry of sensing materials for As(III) detection. Moreover, the intermediate states are complicated to probe because of the ultrashort lifetime and complex reaction conditions of the electron transfer process in electroanalysis, which seriously hinder the identification of the actual active site. Herein, the intrinsic interaction of highly sensitive analytical behavior of nanomaterials is elucidated from the perspective of electronic structure through density functional theory (DFT) and gradient boosting regression (GBR). It is revealed that the atomic radius, d-band center (εd), and the largest coordinative TM-N bond length play a crucial role in regulating the arsenic reduction reaction (ARR) performance by the established ARR process for 27 sets of transition-metal single atoms supported on N-doped graphene. Furthermore, the database composed of filtered intrinsic electronic structural properties and the calculated descriptors of the central metal atom in TM-N4-Gra were also successfully extended to oxygen evolution reaction (OER) systems, which effectively verified the reliability of the whole approach. Generally, a multistep workflow is developed through GBR models combined with DFT for valid screening of sensing materials, which will effectively upgrade the traditional trial-and-error mode for electrochemical interface designing.

12.
Anal Chem ; 95(8): 4104-4112, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36688529

RESUMO

Significant progress has been made in nanomaterial-modified electrodes for highly efficient electroanalysis of arsenic(III) (As(III)). However, the modifiers prepared using some physical methods may easily fall off, and active sites are not uniform, causing the potential instability of the modified electrode. This work first reports a promising practical strategy without any modifiers via utilizing only soluble Fe3+ as a trigger to detect trace-level As(III) in natural water. This method reaches an actual detection limit of 1 ppb on bare glassy carbon electrodes and a sensitivity of 0.296 µA ppb-1 with excellent stability. Kinetic simulations and experimental evidence confirm the codeposition mechanism that Fe3+ is preferentially deposited as Fe0, which are active sites to adsorb As(III) and H+ on the electrode surface. This facilitates the formation of AsH3, which could further react with Fe2+ to produce more As0 and Fe0. Meanwhile, the produced Fe0 can also accelerate the efficient enrichment of As0. Remarkably, the proposed sensing mechanism is a general rule for the electroanalysis of As(III) that is triggered by iron group ions (Fe2+, Fe3+, Co2+, and Ni2+). The interference analysis of coexisting ions (Cu2+, Zn2+, Al3+, Hg2+, Cd2+, Pb2+, SO42-, NO3-, Cl-, and F-) indicates that only Cu2+, Pb2+, and F- showed inhibitory effects on As(III) due to the competition of active sites. Surprisingly, adding iron power effectively eliminates the interference of Cu2+ in natural water, achieving a higher sensitivity for 1-15 ppb As(III) (0.487 µA ppb-1). This study provides effective solutions to overcome the potential instability of modified electrodes and offers a practical sensing platform for analyzing other heavy-metal anions.

13.
J Hazard Mater ; 442: 130122, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36303353

RESUMO

Mutual interference issues between heavy metal ions tremendously affect the detection reliability and accuracy in water quality analysis, especially the serious interference of Cu(II) on the detection of As(III) is greatly hard to overcome, which needs to be solved urgently. Herein, iron single-atom catalysts with different coordination structures of FeN2C2 and FeN3P are constructed to selectively catalyze the detection of As(III) in the coexistence of Cu(II). FeN3P achieves a high sensitivity of 3.90 µA ppb-1 toward As(III) in NH4Cl/NH3·H2O electrolyte (pH 8.0), completely avoiding Cu(II)-interference. Moreover, the turnover frequency (TOF) of FeN3P is an order of magnitude higher than that of FeN2C2. X-ray absorption fine structure (XAFS) spectroscopy and density functional theory (DFT) calculations demonstrate that an As-O bond of H3AsO3 is broken by the strong affinities between both P and O atoms and Fe and As atoms, and H3AsO3 are preferentially reduced by FeN3P during adsorptive process. Meanwhile, the low reaction energy barrier of the rate-determined step for As(III) reduction over FeN3P also accelerates the deposition of As(III) and enhances its response signals. The free-Cu(II) are difficult to adsorb on FeN3P and do not compete with As(III) for Fe active sites, which contributes to the excellent anti-Cu(II) interference capability.

14.
Biosens Bioelectron ; 222: 114990, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36495719

RESUMO

Neurotransmitter serotonin (5-HT) is involved in various physiological and pathological processes. Therefore, its highly sensitive and selective detection in human serum is of great significance for early diagnosis of disease. In this work, employing iron phthalocyanine as Fe source, ultrafine Fe3O4 nanoparticles anchored on carbon spheres (Fe3O4/CSs) have been prepared, which exhibits an excellent electrochemical sensing performance toward 5-HT. With carbonecous spheres turned into conductive carbon spheres under the heat treatment in N2 atmosphere, iron phthalocyanine absorbed on their surfaces are simultaneously pyrolysised and oxidized, and finally transformed into ultrafine Fe3O4 nanoparticles. Electrochemical results demonstrate a high sensitivity (5.503 µA µM-1) and a low detection limit (4 nM) toward 5-HT for as-prepared Fe3O4/CSs. In combination with the morphology and physicochemical property of Fe3O4/CSs, the enhanced sensing mechanism toward 5-HT is disscussed. In addition, the developed electrochemical sensor also displays a good sensing stability and an anti-interferent ability. Further applied in real human serum samples, a satisfactory recovery rate is achieved. Promisingly, the developed electrochemical sensor can be employed for the determination of 5-HT in actual samples.


Assuntos
Técnicas Biossensoriais , Nanopartículas , Humanos , Carbono/química , Serotonina , Limite de Detecção , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos
15.
Anal Chem ; 94(40): 13631-13641, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-36150119

RESUMO

Constructing high-effective electrode sensing interfaces has been considered an effective method for electrochemical detection toward heavy metal ions (HMIs). However, most research has been devoted to enhancing the stripping currents of HMIs by simply improving the adsorptive capacity and conductivity of the electrode modified materials, while lacking theoretical guidelines in fabricating catalytic sensing interfaces. Besides, the understanding of detection mechanisms is quite unscientific from the perspective of catalysis. This perspective summarizes five general strategies in designing highly efficient sensing interfaces in the recent five years, including modulating crystal phases, orientations and planes, defect engineering, ionic valence state cycle engineering, adsorption in situ catalysis strategy, and construction of atomic level catalytic active sites. What's more, the catalytic mechanisms for improving the signals of HMIs, such as boosting the electron transfer rates and conversion rates, lowering the energy barriers, etc., are introduced and emphasized. This study has a great significance in directionally controlling functionalized electrochemical sensors to achieve excellent sensitivity and selectivity in detecting environmental pollutants from the view of catalysis, and it also brings enlightenments and guidance to develop new electroanalytical methods.


Assuntos
Poluentes Ambientais , Metais Pesados , Catálise , Eletrodos , Íons/química , Metais Pesados/química
16.
J Hazard Mater ; 435: 129009, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35500344

RESUMO

Constructing catalysts with simple structures, uniform effective sites, and excellent performance is crucial for understanding the reaction mechanism of target pollutants. Herein, the single-atom catalyst of Mn-intercalated graphitic carbon nitride (Mn/g-C3N4) was prepared. It was found that the intercalated Mn atoms acted as strong electron donors to effectively tune the electronic structure distribution of the in-situ N atoms, providing a large number of negative potential atomic-scale sites for catalytic reactions. In the detection, the in-situ N atom established an electron bridge for the transient electrostatic trapping of free Pb(II), which induced Pb-N-Mn coordination bonding. Even in g-C3N4-loaded Mn nanoparticles, the N atom was again confirmed to be the interaction site for coupling with Pb. And the MnII-N4-C/MnIV-N4-C cycle actively participated in the electrocatalysis of Pb(II) was confirmed. Moreover, Mn/g-C3N4 achieved highly stable and accurate detection for Pb(II) with a sensitivity of 2714.47 µA·µM-1·cm-2. And excellent reproducibility and specific detection of real water samples made the electrode practical. This study contributes to understanding the changes in the electronic structure of chemically inert substrates after single-atom intercalation and the interaction between contaminants and the microstructure of sensitive materials, providing a guiding strategy for designing highly active electrocatalytic interfaces for accurate electroanalysis.

17.
Anal Chem ; 94(16): 6225-6233, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35404584

RESUMO

Interference among multiple heavy metal ions (HMIs) is a significant problem that must be solved in electroanalysis, which extremely restricts the practical popularization of electrochemical sensors. However, due to the limited exploration of the intrinsic mechanism, it is still difficult to confirm the influencing factors. In this work, a series of experimental and theoretical electroanalysis models have been established to investigate the electroanalysis results of Cu(II), Cd(II), As(III), and their mixtures, which were based on the simple structure and stable coordination of nickel single-atom catalysts. X-ray absorption spectroscopy and density functional theory calculations were used to reveal the underlying detection mechanism of the 50-fold boosting effect of Cu(II) on As(III) while Cd(II) inhibits As(III). Combining the application of the thermodynamic model and Fourier transform infrared reflection, the specific interaction of the nanomaterials and HMIs on the interface is considered to be the fundamental source of the interference. This work opens up a new way of thinking about utilizing the unique modes of interplay between nanomaterials and HMIs to achieve anti-interference intelligent electrodes in stripping analysis.


Assuntos
Metais Pesados , Materiais Inteligentes , Cádmio/química , Íons , Metais Pesados/química , Termodinâmica
18.
Anal Chim Acta ; 1200: 339607, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35256149

RESUMO

Constructing a highly sensitive and selective electrochemical interface is of great significance for the effective detection of Hg2+ in water and biological samples. Herein, Co3O4 nanopolyhedron (NP) anchored on nitrogen-doped reduced graphene oxide (N-RGO) is utilized as the electrode material for the detection of Hg2+ in the range of 0.1 µM-1.0 µM, with high sensitivity (1899.70 µA µM-1 cm-2) and low detection limits (0.03 µM) in natural water. Moreover, the Co3O4-NP/N-RGO modified electrode possesses reasonable anti-interference ability for Hg2+ in the presence of inorganic ions and glucose, which is the basis of its good response to trace Hg2+ in serum. Besides, combined with X-ray photoelectron spectroscopy (XPS) and density functional theory (DFT) calculations, the electron transfer tendency is revealed. Additionally, combined with the electron state density of Co-p, it is speculated that Co3+ is an optimum active site for catalytic reaction. The above results elucidate an electrochemically sensitive interface is constructed to realize the efficient detection of Hg2+, which provides some theoretical guidance for the development of electrochemical sensors.


Assuntos
Grafite , Mercúrio , Cobalto , Técnicas Eletroquímicas/métodos , Grafite/química , Óxidos
19.
Anal Chem ; 94(7): 3211-3218, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35104121

RESUMO

Vacancy and doping engineering are promising pathways to improve the electrocatalytic ability of nanomaterials for detecting heavy metal ions. However, the effects of the electronic structure and the local coordination on the catalytic performance are still ambiguous. Herein, cubic selenium vacancy-rich CoSe2 (c-CoSe2-x) and P-doped orthorhombic CoSe2-x (o-CoSe2-x|P) were designed via vacancy and doping engineering. An o-CoSe2-x|P-modified glass carbon electrode (o-CoSe2-x|P/GCE) acquired a high sensitivity of 1.11 µA ppb-1 toward As(III), which is about 40 times higher than that of c-CoSe2-x, outperforming most of the reported nanomaterial-modified glass carbon electrodes. Besides, o-CoSe2-x|P/GCE displayed good selectivity toward As(III) compared with other divalent heavy metal cations, which also exhibited excellent stability, repeatability, and practicality. X-ray absorption fine structure spectroscopy and density functional theory calculation demonstrate that electrons transferred from Co and Se to P sites through Co-P and Se-P bonds in o-CoSe2-x|P. P sites obtained plentiful electrons to form active centers, which also had a strong orbital coupling with As(III). In the detection process, As(III) was bonded with P and reduced by the electron-rich sites in o-CoSe2-x|P, thus acquiring a reinforced electrochemical sensitivity. This work provides an in-depth understanding of the influence of the intrinsic physicochemical properties of sensitive materials on the behavior of electroanalysis, thus offering a direct guideline for creating active sites on sensing interfaces.


Assuntos
Eletrônica , Elétrons , Teoria da Densidade Funcional , Espectroscopia por Absorção de Raios X , Raios X
20.
Anal Chim Acta ; 1189: 339208, 2022 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-34815044

RESUMO

The electrochemical method for highly sensitive determination of arsenic(III) in real water samples with noble-metal-free nanomaterials is still a difficult but significant task. Here, an electrochemical sensor driven by noble-metal-free layered porous Fe3O4/Co3S4 nanosheets was successfully employed for As(III) analysis, which was prepared via a facile two-step method involves a hydrothermal treatment and a subsequent sulfurization process. As expected, the electrochemical detection of As(III) in 0.1 M HAc-NaAc (pH 6.0) by square wave anodic stripping voltammetry (SWASV) with a considerable sensitivity of 4.359 µA/µg·L-1 was obtained, which is better than the commonly used noble metals modified electrodes. Experimental and characterization results elucidate the enhancement of As(III) electrochemical performance could be attributed to its nano-porous structure, the presence of oxygen vacancies and strong synergetic coupling effects between Fe3O4 and Co3S4 species. Besides, the Fe3O4/Co3S4 modified screen printed carbon electrode (Fe3O4/Co3S4-SPCE) shows remarkable stability and repeatability, valuable anti-interference ability and could be used for detection in real water samples. Consequently, the results confirm that as-prepared porous Fe3O4/Co3S4 nanosheets is identified as a promising modifier to detect As(III) in real sample analysis.


Assuntos
Técnicas Eletroquímicas , Oxigênio , Carbono , Eletrodos , Ouro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...