Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Diagnostics (Basel) ; 14(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38611585

RESUMO

BACKGROUND AND OBJECTIVE: The dynamic assessment of disease activity during the follow-up of patients with Crohn's disease (CD) remains a significant challenge. In this study, we aimed to identify the role of dynamic contrast-enhanced ultrasound (DCE-US) in the evaluation of activity of CD. METHODS: In the retrospective study, patients diagnosed with CD in our hospital were included. All the diagnoses were confirmed by clinical symptoms and ileocolonoscopical results. All patients underwent intestinal ultrasound and contrast-enhanced ultrasound (CEUS) examinations within 1 week of the ileocolonoscopy examinations. Acuson Sequoia (Siemens Healthineers, Mountain View, CA, USA) and Resona R9 Elite (Mindray Medical Systems, China) with curved array and Line array transducers were used. The CEUS examination was performed with SonoVue (Bracco SpA, Milan, Italy). DCE-US analysis was performed by UltraOffice (version: 0.3-2010, Mindray Medical Systems, China) software. Two regions of interest (ROIs) were set in the anterior section of the infected bowel wall and its surrounding normal bowel wall 2 cm distant from the inflamed area. Time-intensity curves (TICs) were generated and quantitative perfusion parameters were obtained after curve fittings. The Simple Endoscopic Score for Crohn's disease (SES-CD) was regarded as the reference standard to evaluate the activity of CD. The receiver operating characteristic curve (ROC) analyses were used to determine the diagnostic efficiency of DCE-US quantitative parameters. RESULTS: From March 2023 to November 2023, 52 CD patients were included. According to SES-CD score, all patients were divided into active group with the SES-CD score > 5 (n = 39) and inactive group SES-CD score < 5 (n = 13). Most of the active CD patients showed bowel wall thickness (BWT) > 4.2 mm (97.4%, 38/39) or mesenteric fat hypertrophy (MFH) on intestinal ultrasound (US) scan (69.2%, 27/39). Color Doppler signal of the bowel wall mostly showed spotty or short striped blood flow signal in active CD patients (56.4%, 22/39). According to CEUS enhancement patterns, most active CD patients showed a complete hyperenhancement of the entire intestinal wall (61.5%, 24/39). The TICs of active CD showed an earlier enhancement, higher peak intensity, and faster decline. Among all CEUS quantitative parameters, amplitude-derived parameters peak enhancement (PE), wash-in area under the curve (WiAUC), wash-in rate (WiR), wash-in perfusion index (WiPI), and wash-out rate (WoR) were significantly higher in active CD than in inactive CD (p < 0.05). The combined AUROC of intestinal ultrasound features and DCE-US quantitative perfusion parameters in the diagnosis of active CD was 0.987, with 97.4% sensitivity, 100% specificity, and 98.1% accuracy. CONCLUSIONS: DCE-US with quantitative perfusion parameters is a potential useful noninvasive imaging method to evaluate the activity of Crohn's disease.

2.
Clin Hemorheol Microcirc ; 86(1-2): 51-61, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37638422

RESUMO

OBJECTIVES: To explore the technical and clinical evaluation of ultrasound-derived fat fraction (UDFF) measurement in adult patients in whom fatty liver was suspected. MATERIALS AND METHODS: In this prospective study, 41 participants were initially enrolled in our hospital between October 2022 and December 2022 and received UDFF assessment using Siemens ACUSON Sequoia system equipped with DAX transducer. UDFF measurement was performed three times to obtain UDFF values from each imaging location (V hepatic segment and VIII hepatic segment) per participant, and the depth (skin-to-capsule distance) was automatically measured. The echogenicity of liver tissue in B mode ultrasound (BMUS) was compared to the normal kidney tissue, and fatty liver was graded as mild (Grade 1), moderate (Grade 2), and severe (Grade 3). The median of the acquired overall median UDFF values was used for statistical analysis. All ultrasound examinations were performed by one of two radiologists (with 20 and 10 years of liver ultrasound imaging experience). RESULTS: Finally, UDFF measurement was successfully performed on 38 participants to obtain valid values, including 21 men with a median age of 40.0 years (interquartile range [IQR]: 23.0 - 58.5) and 17 women with a median age of 60.0 years (IQR: 29.5 - 67.0). Fatty liver was diagnosed by BMUS features in 47.4% (18/38) participants. Among all participants, the median UDFF value was 7.0% (IQR: 4.0 - 15.6). A significant difference in UDFF values was found between participants with fatty liver and without fatty liver (U = 7.0, P < 0.001), and UDFF values elevated as the grade of the fatty liver increased (P < 0.001). The median UDFF values from the three UDFF measurements obtained during each ultrasound examination showed excellent agreement (ICC = 0.882 [95% confidence interval: 0.833 - 0.919]). The Spearman correlation of UDFF values in different depths was moderate, with a rs value of 0.546 (P < 0.001). No significant differences in UDFF values were found between V hepatic segment and VIII hepatic segment (U = 684.5, P = 0.697). CONCLUSIONS: UDFF provides a novel non-invasive imaging tool for hepatic steatosis assessment with excellent feasibility.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Masculino , Adulto , Humanos , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Estudos Prospectivos , Fígado/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Imageamento por Ressonância Magnética/métodos
3.
Clin Hemorheol Microcirc ; 86(3): 313-326, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37927251

RESUMO

OBJECTIVES: To evaluate the efficacy of the radiomics model based on preoperative B-mode ultrasound (BMUS) and shear wave elastography (SWE) for predicting the occurrence of clinically relevant-postoperative pancreatic fistula (CR-POPF). METHODS: Patients who were scheduled to undergo pancreatectomy were prospectively enrolled and received ultrasound assessment within one week before surgery. The risk factors of POPF (grades B and grades C) were analyzed. Preoperative BMUS images, SWE values of pancreatic lesions and surrounding parenchyma were used to build preoperative prediction radiomics models. Radiomic signatures were extracted and constructed using a minimal Redundancy Maximal Relevance (mRMR) algorithm and an L1 penalized logistic regression. A combined model was built using multivariate regression which incorporated radiomics signatures and clinical data. RESULTS: From January 2020 to November 2021, a total of 147 patients (85 distal pancreatectomies and 62 pancreaticoduodenectomies) were enrolled. During the three-week follow-up after pancreatectomy, the incidence rates of grade B/C POPF were 28.6% (42/147). Radiomic signatures constructed from BMUS of pancreas parenchymal regions (panRS) achieved an area under the receiver operating characteristic curve (AUC) of 0.75, accuracy of 68.7%, sensitivity of 85.7 %, and specificity of 61.9 % in preoperative noninvasive prediction of CR-POPF. The AUC of the radiomics model increased to 0.81 when panRS was used for the prediction of CR-POPF after pancreaticoduodenectomy. CONCLUSIONS: Radiomics model based on ultrasound images was potentially useful for predicting CR-POPF. Patients with high-risk factors should be closely monitored when postoperation.


Assuntos
Pancreatectomia , Fístula Pancreática , Humanos , Pancreatectomia/efeitos adversos , Fístula Pancreática/etiologia , Fístula Pancreática/complicações , Radiômica , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Pancreaticoduodenectomia/efeitos adversos , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Estudos Retrospectivos
4.
Ultrasound Med Biol ; 50(1): 39-46, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37778901

RESUMO

OBJECTIVE: The aim of the work described here was to evaluate the impact of hepatocellular carcinoma (HCC) tumor size on Sonazoid contrast-enhanced ultrasound (CEUS) enhancement features, especially in tumors with diameters ≤30 mm and <10 mm. METHODS: In this retrospective study, we included patients with histopathologically confirmed HCC lesions and divided them into three groups on the basis of tumor size. All patients underwent Sonazoid-enhanced CEUS examinations before surgery. B-mode ultrasound (BMUS) features and CEUS enhancement patterns were evaluated according to current World Federation for Ultrasound in Medicine and Biology Guidelines criteria. The χ2- and Student t-tests were used to compare differences between groups. RESULTS: We included 132 patients with histopathologically confirmed HCC lesions from November 2020 to September 2022. On the basis of tumor size, patients were divided into group 1 (<10 mm, n = 5), group 2 (10-30 mm, n = 54) and group 3 (>30 mm, n = 73). On BMUS, most HCCs appeared heterogeneous but predominantly hypo-echoic (61.4%, 81/132) with ill-defined margins and irregular shapes. Meanwhile, iso-echoic features were more common in small HCCs ≤30 mm (15.3%, 9/59), but a mixed hyper- and hypo-echoic appearance was more common in HCCs >30 mm (17.8%, 13/73) (p = 0.003). On Sonazoid-enhanced CEUS, all HCCs presented arterial phase hyperenhancement (APHE) (100.0%, 132/132). Most HCCs >30 mm exhibited heterogeneous hyperenhancement (86.3%, 63/73), whereas nearly one-third of small HCCs ≤30 mm exhibited homogeneous hyperenhancement (35.6%, 21/59) (p = 0.003). In the portal venous phase, there was a significantly higher proportion of washout in HCCs >30 mm (84.9%, 62/73) than in small HCCs ≤30 mm (64.4%, 38/59) (p = 0.006). During the Kupffer phase, 11 additional hypo-enhanced lesions (mean size: 14.1 ± 4.1 mm, iso-echoic on BMUS), which were also suspected to be HCC lesions, were detected in 5 patients with small HCCs ≤30 mm and 4 patients with HCCs >30 mm. All 5 cases of HCCs <10 mm exhibited APHE and late washout (>60 s). The majority (3/5, 60%) exhibited washout in the portal venous phase (70, 74 and 75 s), one case did so in the late phase (125 s) and another in the Kupffer phase (420 s). CONCLUSION: Tumor size had a significant impact on the washout features of HCC lesions on Sonazoid-enhanced CEUS. Small HCC lesions ≤30 mm had a higher proportion of relatively late washout in comparison to larger lesions. Sonazoid-enhanced CEUS might be helpful in the detection and characterization of HCC lesions <10 mm.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Meios de Contraste , Ultrassonografia
5.
Diagnostics (Basel) ; 13(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38066809

RESUMO

Malignant focal liver lesions (FLLs) are commonly reported in adults but rarely seen in the pediatric population. Due to the rarity, the understanding of these diseases is still very limited. In children, most malignant FLLs are congenital. It is very important to choose appropriate imaging examination concerning various factors. This paper will outline common pediatric malignant FLLs, including hepatoblastoma, hepatocellular carcinoma, and cholangiocarcinoma and discuss them against the background of the latest knowledge on comparable/similar tumors in adults. Medical imaging features are of vital importance for the non-invasive diagnosis and follow-up of treatment of FLLs in pediatric patients. The use of CEUS in pediatric patients for characterizing those FLLs that remain indeterminate on conventional B mode ultrasounds may be an effective option in the future and has great potential to be integrated into imaging algorithms without the risk of exposure to ionizing radiation.

6.
Diagnostics (Basel) ; 13(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38132242

RESUMO

Malignant focal liver lesions (FLLs) represent various kinds of epithelial and mesenchymal tumors. In pediatric patients, the understanding of pediatric liver diseases and associated imaging manifestations is essential for making accurate diagnosis and differential diagnosis. This paper will discuss the latest knowledge of the common pediatric malignant FLLs, including undifferentiated embryonal sarcoma, rhabdomyosarcoma, epithelioid hemangioendothelioma, angiosarcoma, and malignant rhabdoid tumor. Medical imaging features are not only helpful for clinical diagnosis, but can also be useful in the evaluation and follow-up of pre- and post-treatment. The future perspectives of contrast-enhanced ultrasound (CEUS) enhancement patterns of FLLs in pediatric patients are also mentioned.

7.
Front Bioeng Biotechnol ; 11: 1209294, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37555078

RESUMO

Polyurethanes and plastics have become ubiquitous in modern society, finding use in a wide variety of applications such as clothing, automobiles, and shoes. While these materials provide numerous benefits to human life, their persistence in the environment has caused ecological imbalances. Therefore, new processes are needed to make these materials more sustainable and re-usable. In 2011, Ludwik Leibler introduced a new class of covalent adaptable network (CAN) polymers called Vitrimers. Vitrimers possess self-repairing properties and are capable of being reprocessed due to dynamic exchange or breaking/recombination of covalent bonds, similar to thermoset materials. This study explores the synthesis of Vitrimers using waste polyurethane or plastics as feedstock. The raw materials were glycolysed to obtain the glycolysate, which was then used as a reagent for the Vitrimers synthesis. The main objective of this study was to achieve the maximum self-repairable rate of the prepared sample. The Taguchi orthogonal analysis was employed to guide the experiments. The optimized experimental conditions for polyurethane glycolysis were determined to be under ethylene glycol and catalyzed by sodium hydroxide at 180°C for 1 h, resulting in the highest hydroxyl concentration in the glycolysate. In the second stage of the experiment, the ratio of hexamethylene diisocyanate (HDI) to solvent was set to 2, HDI trimer to solvent was 2, and PGE/glycolysate was 0.5, with equal amounts of PEG and glycolysate used as the solvent. The reaction was carried out at 80°C for 1 h, achieving a self-repair ability of 47.5% in the prepared sample. The results of this study show that waste polyurethane or plastics can be effectively recycled and transformed into vitrimers with self-repairing properties. The use of glycolysis as a feedstock is a promising method for the sustainable recycling of polyurethane waste. The Taguchi orthogonal analysis is an effective approach for optimizing experimental conditions and improving the reproducibility of the results.

8.
Acad Radiol ; 30 Suppl 1: S155-S163, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37407373

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the performance of attenuation imaging (ATI) based on ultrasound for detection of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS: This prospective study was approved by our institutional review board (B2021-092R). Written informed consent was obtained from all patients. This study included 60 patients who had clinical suspicion of NAFLD and were referred for liver biopsy after ATI and controlled attenuation parameter (CAP) examinations between September 2020 and December 2021. The histologic hepatic steatosis was graded. The area under curve (AUC) analysis was performed. RESULTS: The success rate of the ATI examination was 100%. The intraobserver reproducibility of ATI was 0.981. The AUCs of ATI for detecting ≥S1, ≥S2, and S3 were 0.968 (cut-off value of 0.671 dB/cm/MHz), 0.911 (cut-off value of 0.726 dB/cm/MHz), and 0.766 (cut-off value of 0.757 dB/cm/MHz), respectively. The AUCs of CAP for detecting ≥S1, ≥S2, and S3 were 0.916 (cut-off value of 258.5 dB/m), 0.872 (cut-off value of 300.0 dB/m), and 0.807 (cut-off value of 315.0 dB/m), respectively. The diagnostic values showed no significant difference between ATI and CAP in detecting ≥S1, ≥S2, and S3 (P = .281, P = .254, and P = .330, respectively). The ATI had significant correlations with high-density lipoprotein cholesterol (P < .001), and with triglycerides (P = .015). CONCLUSION: ATI showed good feasibility and diagnostic performance in the detection of varying degrees of hepatic steatosis in NAFLD patients.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Fígado/diagnóstico por imagem , Fígado/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Técnicas de Imagem por Elasticidade/métodos , Curva ROC , Biópsia
9.
Clin Hemorheol Microcirc ; 83(4): 409-420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36683500

RESUMO

OBJECTIVES: To explore the potential added value of dynamic contrast enhanced ultrasound (DCE-US) using VueBox® software for the diagnosis of small solid thyroid nodules (≤1.0 cm). PATIENTS AND METHODS: This prospective study was approved by the institutional review board and it was performed at two hospitals from January 2020 to October 2020. B mode ultrasound and contrast enhanced ultrasound (CEUS) images were obtained for 79 small solid thyroid nodules (≤1.0 cm) confirmed by ultrasound-guided fine needle aspiration cytology results in 79 consecutive patients (55 women and 24 men, median age: 41 years). The CEUS time-intensity curves (TICs) of thyroid nodules and surrounding parenchyma were created by VueBox® software (Bracco, Italy). The CEUS quantitative parameters were obtained after curve fitting. The diagnostic performance of CEUS and DCE-US was evaluated and compared. The weighted kappa statistic (κ) was performed to assess the interobserver agreement and consistency between the diagnosis of CEUS and DCE-US. RESULTS: Among the 79 thyroid nodules, 56 (70.9 %) were malignant and 23 (29.1 %) were benign lesions. Hypoenhancement during the arterial phase of CEUS was associated with malignancy (P < 0.001), with an AUC of 0.705 (sensitivity 71.4 %, specificity 69.6 %). Among all CEUS quantitative parameters, the peak enhancement (PE), wash-in rate (WiR), and wash-out rate (WoR) of DCE-US in malignancies were significantly lower than those in benign nodules (P = 0.049, P = 0.046, and P = 0.020, respectively). The area under the receiver operating characteristic curves (AUCs) of PE, WiR, and WoR were 0.642 (sensitivity 65.2 %, specificity 67.9 %), 0.643 (sensitivity 43.5 %, specificity 91.1 %), and 0.667 (sensitivity 69.6 %, specificity 69.6 %) in differentiation between benign and malignant small solid thyroid nodules (≤1.0 cm), respectively. Comparing the quantitative parameters of DCE-US between small solid thyroid nodules and surrounding normal thyroid parenchyma, the PE, WiAUC, WiR, wash-in perfusion index (WiPI), WoAUC, WiWoAUC, and WoR of the nodules were significantly lower than those of normal thyroid tissue (P = 0.008, P < 0.001, P = 0.037, P = 0.009, P = 0.003, P = 0.002, P = 0.049, respectively). A total of 16 (20.3 %) nodules showed isoenhancement during the arterial phase of CEUS, while the median PE ratio of surrounding tissue and thyroid nodules was 1.70 (IQR: 1.33-1.89). CONCLUSIONS: VueBox® is a helpful tool for the evaluation of dynamic microvascularization of thyroid nodules, and DCE-US using VueBox® perfusion analysis could provide added values for differential diagnosis of small solid thyroid nodules (≤1.0 cm).


Assuntos
Nódulo da Glândula Tireoide , Masculino , Humanos , Feminino , Adulto , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Estudos Prospectivos , Meios de Contraste , Perfusão/métodos , Ultrassonografia/métodos , Diagnóstico Diferencial
11.
EMBO Rep ; 23(6): e54275, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35437924

RESUMO

Our understanding of human hepatocellular carcinoma (HCC) development and progression has been hampered by the lack of in vivo models. We performed a genetic screen of 10 oncogenes and genetic mutations in Fah-ablated immunodeficient mice in which primary human hepatocytes (PHHs) are used to reconstitute a functional human liver. We identified that MYC, TP53R249S , and KRASG12D are highly expressed in induced HCC (iHCC) samples. The overexpression of MYC and TP53R249S transform PHHs into iHCC in situ, though the addition of KRASG12D significantly increases the tumorigenic efficiency. iHCC, which recapitulate the histological architecture and gene expression characteristics of clinical HCC samples, reconstituted HCC after serial transplantations. Transcriptomic analysis of iHCC and PHHs showed that MUC1 and FAP are expressed in iHCC but not in normal livers. Chimeric antigen receptor (CAR) T cells against these two surface markers efficiently lyse iHCC cells. The properties of iHCC model provide a biological basis for several clinical hallmarks of HCC, and iHCC may serve as a model to study HCC initiation and to identify diagnostic biomarkers and targets for cellular immunotherapy.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Animais , Carcinoma Hepatocelular/genética , Hepatócitos , Humanos , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/patologia , Camundongos , Proteínas Proto-Oncogênicas p21(ras)
12.
Clin Hemorheol Microcirc ; 80(4): 463-471, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34864651

RESUMO

PURPOSE: To compare the application value of the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) and the American Thyroid Association (ATA) guidelines in the risk stratification of thyroid isthmic nodules. METHODS: A total of 315 patients with thyroid isthmic nodules (315 nodules) confirmed by surgical pathology or fine-needle aspiration biopsy (FNAB) were selected in this retrospective study. The nodules were evaluated and classified according to ACR TI-RADS and the ATA guidelines. Taking pathological results as the reference, receiver operating characteristic (ROC) curves were drawn to evaluate the diagnostic capabilities of the ACR TI-RADS and the ATA guidelines for the risk stratification of thyroid isthmic nodules. The unnecessary biopsy rates and false-negative rates were compared. RESULTS: Multivariate analysis of ultrasonographic features of suspicious malignancies showed that an aspect ratio > 1 was not an independent risk factor for malignant thyroid nodules located in the isthmus (odds ratio: 3.193, 95%confidence interval: 0.882-11.552) (P = 0.077). The area under the ROC curves for diagnosing malignant thyroid nodules located in the isthmus in by the ACR TI-RADS and the ATA guidelines were 0.853 and 0.835, respectively. Under the management recommendations of the ACR TI-RADS and ATA guidelines, the false-negative rates of malignant thyroid nodules were 66.2%(ATA intermediate suspicion), 62.3%(ACR TR 4), 81.8%(ATA high suspicion) and 86.5%(ACR TR 5). CONCLUSION: Both the ACR TI-RADS and the ATA guidelines have high diagnostic capabilities for the risk stratification of thyroid isthmic nodules. For ACR TR 4 and 5 and ATA intermediate- and high-suspicion thyroid isthmic nodules with a maximum diameter < 1 cm, the criteria for puncture should be lowered, and FNAB should be done to clarify their diagnosis.


Assuntos
Nódulo da Glândula Tireoide , Sistemas de Dados , Humanos , Estudos Retrospectivos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos
13.
Ultraschall Med ; 43(6): 599-607, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34479373

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of the American College of Radiology (ACR) Thyroid Image Reporting and Data System (TI-RADS), contrast-enhanced ultrasound (CEUS), and a modified TI-RADS in differentiating benign and malignant nodules located in the isthmus. METHODS: This retrospective study was approved by the institutional review board. Informed consent was obtained. Grayscale ultrasound (US) and CEUS images were obtained for 203 isthmic thyroid nodules (46 benign and 157 malignant) in 198 consecutive patients (156 women, mean age: 44.7 years ±â€Š11.3 [standard deviation]; 47 men, mean age: 40.9 years ±â€Š11.0). The area under the receiver operating characteristic curve (AUC) of the diagnostic performance of the ACR TI-RADS, CEUS, and the modified TI-RADS were evaluated. RESULTS: Lobulated or irregular margins (P = 0.001; odds ratio [OR] = 9.250) and punctate echogenic foci (P = 0.007; OR = 4.718) on US and hypoenhancement (P < 0.001; OR = 20.888) on CEUS displayed a significant association with malignancy located in the isthmus. The most valuable method to distinguish benign nodules from malignant nodules was the modified TI-RADS (AUC: 0.863 with modified TR5), which was significantly better than the ACR TI-RADS (AUC: 0.738 with ACR TR5) (P < 0.001) but showed no significant difference with respect to CEUS (AUC: 0.835 with hypoenhancement) (P = 0.205). The diagnostic value was significantly different between CEUS and the ACR TI-RADS (P = 0.028). CONCLUSION: The modified TI-RADS could significantly improve the accuracy of the diagnosis of thyroid nodules located in the isthmus.


Assuntos
Nódulo da Glândula Tireoide , Masculino , Humanos , Feminino , Adulto , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Estudos Retrospectivos , Sistemas de Dados , Ultrassonografia/métodos
14.
Ultrasound Med Biol ; 45(9): 2289-2297, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31196745

RESUMO

Agreement between ultrasound strain elastography (SE) scores of transverse and longitudinal views of thyroid nodules was investigated, and the diagnostic performance of these scores in predicting thyroid malignancy was assessed. From December 2016 to February 2017, a total of 250 thyroid nodules in 232 patients (62 males and 188 females, mean age: 45 y [20-75 y]) were enrolled. Diagnostic agreement between SE scores obtained in different views was assessed. Sensitivity, specificity, area under the receiver operating characteristic curve (Az) of the SE score in different criteria (criterion 1, SE score ≥4 from any view is defined as suspicious; criterion 2, SE score ≥4 as in only transverse view; and criterion 3, SE score ≥4 only from longitudinal view) were evaluated. Diagnostic agreement between SE scores of different views was fair (κ = 0.227). The Az value for criterion 1 (0.770, 95% confidence interval [CI]: 0.713, 0.820) was the highest among the three criteria, significantly higher than that of criterion 2 (0.692, 95% CI: 0.631, 0.749) (p < 0.001), but not statistically significantly different from that of criterion 3 (0.768, 95% CI: 0.711, 0.819) (p = 0.909). However, the Az value for criterion 3 was higher than that for criterion 2 (p < 0.005). The results indicated that criterion 1 had high sensitivity (80.0%) and criterion 2 had high specificity (68.0%). Our study found that the agreement between SE scores of different views was fair. SE scores ≥4 in either view were most sensitive for predicting malignant thyroid nodules.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia
15.
J Nippon Med Sch ; 84(3): 118-124, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28724845

RESUMO

OBJECTIVE: The aim of this study was to test the predictive value of a Thyroid Imaging Reporting and Data System (TI-RADS) for malignant thyroid nodules. METHODS: Ultrasonographic data was examined for 910 thyroid nodules with histopathologically confirmed diagnoses. Nodules were placed into incomplete (category 0) or complete final categories (1, 2, 3a, 3b, 3c, 4, or 5) based on the presence and number of ultrasonographic features of malignancy, and the predictive value for the malignancy of nodules in categories 2-4 was assessed. RESULTS: The overall rate of malignancy among thyroid nodules included in the study was 59.34%. The rate of malignancy gradually increased according to TI-RADS categories as follows: category 2, 5.4%; category 3 (a-c), 36% to 92%; and category 4, 99.0%. When nodules of category 2 were counted as benign, the reliability of the TI-RADS classification for determining the risk of malignancy was as follows; sensitivity, 98.15%; specificity, 47.84%; positive predictive value, 73.31%; negative predictive value, 94.65%; and odds ratio, 48.61. CONCLUSIONS: The TI-RADS classification used in this study is relatively simple and provides a reliable measure of the risk of malignancy of thyroid nodules.


Assuntos
Projetos de Pesquisa , Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Risco , Sensibilidade e Especificidade , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia
16.
J Chromatogr A ; 1305: 17-26, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23895918

RESUMO

A new method of hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for simultaneous analysis of various environmental estrogens. Taking eight environmental estrogens (17ß-estradiol (E2), estrone (E1), estriol (E3), 17α-ethynylestradiol (EE), diethylstilbestrol (DES), dienestrol (DIS), bisphenol-A (BPA) and 4-t-octylphenol (OP)) as the target analytes, the factors affecting HF-LLLME-HPLC-UV were investigated in detail. Under the optimized experimental conditions, the extraction efficiency of HF-LLLME for eight target estrogens was in the range of 13.9-62.8%, and the enrichment factor was 88-376-fold. The limits of detection (LODs) of the proposed method for eight target estrogens of ES, BPA, E2, EE, E1, DES, DIS and OP were 0.11, 0.055, 0.66, 0.55, 0.51, 0.20, 0.11 and 1.46ng/mL, respectively, which are lower than that obtained by some other sample pretreatment methods followed by HPLC-UV analysis. The relative standard deviations of the method (RSDs, cE3, BPA, DIS=5ng/mL, cE1, E2, EE, OP=40ng/mL, cDES=15ng/mL, n=7) are in the range of 5.5-8.4%. The developed method was applied for the determination of environmental estrogens in environmental and biological samples (sediment and fish), and none of the eight target estrogens was detected. The recoveries for the spiking samples with low, medium and high spiking levels were in the range of 73.2-117.5%. The proposed method has been demonstrated to be suitable for simultaneous determination of multiple environmental estrogens with high sensitivity, high enrichment factors, good sample clean-up ability and no derivatization required.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Poluentes Ambientais/análise , Estrogênios/análise , Microextração em Fase Líquida , Espectrofotometria Ultravioleta/métodos , Animais , Peixes , Sedimentos Geológicos/química , Concentração de Íons de Hidrogênio , Limite de Detecção , Concentração Osmolar , Hidróxido de Sódio/química , Temperatura , beta-Ciclodextrinas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...