Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 187(11): 636, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33141322

RESUMO

A novel chiral sensing platform, 6-O-α-maltosyl-ß-cyclodextrin (Mal-ßCD)-based film, is proposed for selective electrochemical recognition of tyrosine (Tyr) enantiomers. Black phosphorus nanosheets (BP NSs) and Mal-ßCD modified glassy carbon electrode (Mal-ßCD/BP NSs/GCE) were prepared by a layer-to-layer drop-casting method, and the platform was easy to fabricate and facile to operate. It is proposed that the amino and hydroxyl groups of the Tyr enantiomers and the chiral hydroxyl groups of Mal-ßCD selectively form intermolecular hydrogen bonds to dominate effective chiral recognition. Two linear equations of Ip (µA) = 11.40 CL-Tyr (mM) + 0.28 (R2 = 0.99147) and Ip (µA) = 7.96 CD-Tyr (mM) + 0.22 (R2 = 0.99583) in the concentration range 0.01-1.00 mM have been obtained. The limits of detection (S/N=3) for L-Tyr and D-Tyr were 4.81 and 6.89 µM, respectively. An interesting phenomenon was that the value of IL-Tyr/ID-Tyr (1.51) in this work was slightly higher than the value of IL-Trp/ID-Trp (1.49) reported in our previous study, where tryptophan (Trp) enantiomers were electrochemically recognized by Nafion (NF)-stabilized BPNSs-G2-ß-CD composite. The two similar sensors fabricated by different methods showed different recognition ability toward either Tyr or Trp enantiomers, and the underlying mechanism was discussed in detail. More importantly, the proposed chiral sensor enables prediction of the percentages of D-Tyr in racemic Tyr mixtures. The chiral sensor may provide a novel approach for the fabrication of novel chiral platforms in the practical detection of L- or D-enantiomer in racemic Tyr mixtures.Graphical abstract.


Assuntos
Nanoestruturas/química , Fósforo/química , Tirosina/química , beta-Ciclodextrinas/química , Técnicas Eletroquímicas/métodos , Limite de Detecção , Estereoisomerismo
2.
Ecotoxicol Environ Saf ; 201: 110862, 2020 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-32559691

RESUMO

In this study, a novel electrochemical sensor based on self-assembled rod-like lanthanum hydroxide-oxidized multi-walled carbon nanotubes (La(OH)3-OxMWCNTs) nanocomposite was developed for sensitive determination of p-nitrophenol (p-NP). The La(OH)3-OxMWCNTs nanocomposite with an interpenetrating networks structure was characterized by field emission electron microscope (FE-SEM), Fourier transform infrared (FT-IR) spectroscopy, Raman spectra and X-ray photoelectron spectroscopy (XPS). The cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements were performed to study the electrochemical behaviors of La(OH)3-OxMWCNTs modified glassy carbon electrode (La(OH)3-OxMWCNTs/GCE). The La(OH)3-OxMWCNTs/GCE was used for sensitive determination of p-NP by CV and linear sweep voltammetry (LSV). Under the optimum conditions, the peak currents of LSV versus the concentrations of p-NP in the range 1.0-30.0 µmol L-1 showed a good linear relationship (R2=0.9971), and the limit of detection (LOD) was calculated to be 0.27 µmol L-1 (signal-to-noise ratio of 3, S/N=3). The recoveries of p-NP in real samples of industrial wastewater and Xiangjiang water at La(OH)3-OxMWCNTs/GCE were in the range of 95.62-110.75% with relative standard deviation (RSD) in the range of 1.65-3.85%. The intra-day and inter-day precisions were estimated to be less than 2.76% (n= 5), indicating that La(OH)3-OxMWCNTs/GCE possessed highly stability. In addition, La(OH)3-OxMWCNTs/GCE sensor showed good anti-interference ability for determination of p-NP in aqueous mixtures containing high concentrations of inorganic and organic interferents, and a decrease of oxidation peak currents by less than 3.57% relative to the initial levels indicated it possessed excellent selectivity. Therefore, La(OH)3-OxMWCNTs/GCE could be used as a fast, selective and sensitive electrochemical sensor platform for the selective determination and quantification of aqueous p-NP.


Assuntos
Técnicas Eletroquímicas/métodos , Lantânio/química , Nanocompostos/química , Nanotubos de Carbono/química , Nitrofenóis/análise , Eletrodos , Limite de Detecção , Oxirredução
3.
Anal Bioanal Chem ; 412(11): 2551-2564, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32162086

RESUMO

A novel electrochemical sensor, platinum nanoparticles/graphene nanoplatelets/multi-walled carbon nanotubes/ß-cyclodextrin composite (PtNPs-GNPs-MWCNTs-ß-CD) modified carbon glass electrode (GCE), was fabricated and used for the sensitive detection of folic acid (FA). The PtNPs-GNPs-MWCNTs-ß-CD nanocomposite was easily prepared with an ultrasound-assisted assembly method, and it was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The electrochemical behavior of FA at PtNPs-GNPs-MWCNTs-ß-CD/GCE was investigated in detail. Some key experimental parameters such as pH, amount of PtNPs-GNPs-MWCNTs-ß-CD composite, and scan rate were optimized. A good linear relationship (R2 = 0.9942) between peak current of cyclic voltammetry (CV) and FA concentration in the range 0.02-0.50 mmol L-1 was observed at PtNPs-GNPs-MWCNTs-ß-CD/GCE. The detection limit was 0.48 µmol L-1 (signal-to-noise ratio = 3). A recovery of 97.55-102.96% was obtained for the determination of FA in FA pills (containing 0.4 mg FA per pill) at PtNPs-GNPs-MWCNTs-ß-CD/GCE, indicating that the modified electrode possessed relatively high sensitivity and stability for the determination of FA in real samples.


Assuntos
Técnicas Eletroquímicas/métodos , Ácido Fólico/análise , Nanocompostos/química , Nanotubos de Carbono/química , Platina/química , Complexo Vitamínico B/análise , Grafite/química , Limite de Detecção , Nanopartículas Metálicas/química , Comprimidos , beta-Ciclodextrinas/química
4.
Ecotoxicol Environ Saf ; 190: 110123, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-31891837

RESUMO

In this work, a novel manganese dioxide-graphene nanosheets (MnO2-GNSs) composite was synthesized by a facile one-step hydrothermal method, in which manganese dioxide (MnO2) was fabricated by hydrothermal reduction of KMnO4 with GNSs. The structure and morphology of MnO2-GNSs composite were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) analysis and X-ray photoelectron spectroscopy (XPS). A sensitive non-enzymatic electrochemical sensor based on MnO2-GNSs composite for the detection of low concentration hydrogen peroxide (H2O2) was fabricated. The electrochemical properties of MnO2-GNSs composite modified glassy carbon electrode (MnO2-GNSs/GCE) were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and amperometry. The observations confirmed that the fabricated sensor exhibited high electrocatalytic activity for oxidation of H2O2 owing to the catalytic ability of MnO2 particles and the conductivity of GNSs. Under the optimum conditions, the calibration curve was linear for the amperometric response versus H2O2 concentration over the range 0.5-350 µM with a low detection limit of 0.19 µM (S/N = 3) and high sensitivity of 422.10 µA mM-1 cm-2. The determination and quantitative analysis of H2O2 in antiseptic solution on MnO2-GNSs/GCE exhibited percent recovery of 96.50%-101.22% with relative standard deviation (RSD) of 1.48%-4.47%. The developed MnO2-GNSs/GCE might be a promising platform for the practical detection of H2O2 due to its prominent properties including excellent reproducibility, good anti-interference and repeatability.


Assuntos
Técnicas Eletroquímicas/métodos , Grafite/química , Peróxido de Hidrogênio/análise , Compostos de Manganês/química , Modelos Químicos , Óxidos/química , Carbono/química , Catálise , Espectroscopia Dielétrica , Eletrodos , Limite de Detecção , Reprodutibilidade dos Testes
5.
Mater Sci Eng C Mater Biol Appl ; 103: 109848, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31349437

RESUMO

Graphene nanoplatelets (GNPs), multiwalled carbon nanotube (MWCNTs) and chitosan (CS) were self-assembled by a facile one-step hydrothermal reaction to obtain novel MWCNTs-CS enfolded GNPs (GNPs-MWCNTs-CS) composite. Fourier transform infrared (FT-IR) spectroscopy, Raman spectroscopy, scanning electron microscopy (SEM), UV-visible (UV-vis) absorption spectroscopy and zeta potential analysis were employed to characterize the morphology, surface composition, interaction, surface charge and stability of the GNPs-MWCNTs-CS composite. The electrochemical behaviors of GNPs-MWCNTs-CS composite modified glassy carbon electrode (GNPs-MWCNTs-CS/GCE) were investigated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The GNPs-MWCNTs-CS/GCE was used for fast and high sensitive determination of bisphenol A (BPA) by differential pulse voltammetry (DPV). Under the optimum conditions, the calibration curve obtained is linear for the current versus the BPA concentration in the range 0.1-100 µM with a detection limit of 0.05 nM (signal-to-noise ratio of 3, S/N = 3). The between-sensor reproducibility was 1.29% (n = 6) for 0.04 mM BPA. The proposed GNPs-MWCNTs-CS/GCE based sensor showed high resistance to interference, good repeatability and excellent reproducibility. Trace BPA in milk samples could also be reliably determined.


Assuntos
Compostos Benzidrílicos/análise , Técnicas Eletroquímicas , Grafite/química , Leite/química , Nanotubos de Carbono/química , Fenóis/análise , Animais , Sensibilidade e Especificidade
6.
Ecotoxicol Environ Saf ; 172: 167-175, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30708228

RESUMO

In this study, platinum nanochains (PtNCs), multi-walled carbon nanotubes (MWCNTs) and graphene nanoparticles (GNPs) were assembled together to form a novel nanocomposite by a facile ultrasonic-assisted blending process. The PtNCs-MWCNTs-GNPs nanocomposite was characterized by high resolution transmission electron microscopy (HR-TEM), energy dispersive X-ray spectroscopy (EDS), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The nanocomposite was used for the modification of glass carbon electrode (GCE) and simultaneous determination of dopamine (DA) and ascorbic acid (AA) by differential pulse voltammetry (DPV) and cycle voltammetry (CV). Under the optimum conditions, the calibration curves obtained are linear for the currents versus DA and AA concentrations over the range 2.00-50.0 µM and 100-1200 µM, respectively. And the detection limits for DA and AA are 0.500 µM and 10.0 µM, respectively. The detection and quantitative analysis of DA and AA in human serum and vitamin C tablets on PtNCs-MWCNTs-GNPs/GCE gave the recoveries of 104-110% and 101-108% with relative standard deviations (RSD) of 4.36-7.48% and 0.620-2.90%, respectively. The proposed PtNCs-MWCNTs-GNPs composite could provide a new platform for the routine analysis of DA and AA in terms of its good anti-interference ability, excellent reproducibility and repeatability, and feasibility of use.


Assuntos
Ácido Ascórbico/análise , Dopamina/análise , Platina/química , Ácido Ascórbico/sangue , Técnicas Biossensoriais , Dopamina/sangue , Técnicas Eletroquímicas , Eletrodos , Grafite/química , Humanos , Limite de Detecção , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Nanocompostos/química , Nanopartículas/química , Nanotubos de Carbono/química , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA