Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39127312

RESUMO

BACKGROUND: Ceramic femoral heads with titanium sleeves are commonly used in revision total hip arthroplasty (rTHA). Companies advise against combination with a retained femoral component from another manufacturer. However, no data are available. The aim of this study was to evaluate and compare the implant failure and revision rates of ceramic heads with a 12/14 titanium sleeve used on manufacturer-compatible versus non-compatible retained femoral components. METHODS: A retrospective single-center cohort analysis was performed using a prospectively maintained institutional arthroplasty registry. We identified 439 patients who received a titanium 12/14 ceramic head during rTHA between January 1st, 2007 and December 31st, 2022. There were 229 manufacturer-compatible and 210 manufacturer-non-compatible retained femoral stems, according to the company's official product compatibility list. Implant failure and re-revision rates were evaluated. RESULTS: After a median follow-up of 6.6 years (IQR (Interquartile-range): 4.5 to 9.3), there was no significant difference (P = 0.770) in the re-revision rate between the manufacturer-compatible group (17.0%) and the non-compatible group (18.1%). Revision-free survival after rTHA was 81.2% in the manufacturer-compatible group and 78.9% in the manufacturer-non-compatible group after 15 years (P = 0.653). Most re-revisions occurred in the first year after rTHA, with 29 of 229 (12.7%) in the manufacturer-compatible group and 24 of 210 (11.4%) in the manufacturer-non-compatible group (P = 0.705). We observed only one implant failure in the manufacturer-non-compatible group, but this was not related to a mismatch problem. CONCLUSION: Although legal uncertainties remain, this study showed no increased risk of implant failure or revision rates when a ceramic femoral head with a 12/14 titanium sleeve was used on a non-compatible femoral stem from a manufacturer.

2.
Bone Joint Res ; 13(7): 353-361, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38981611

RESUMO

Aims: This study aimed to evaluate the BioFire Joint Infection (JI) Panel in cases of hip and knee periprosthetic joint infection (PJI) where conventional microbiology is unclear, and to assess its role as a complementary intraoperative diagnostic tool. Methods: Five groups representing common microbiological scenarios in hip and knee revision arthroplasty were selected from our arthroplasty registry, prospectively maintained PJI databases, and biobank: 1) unexpected-negative cultures (UNCs), 2) unexpected-positive cultures (UPCs), 3) single-positive intraoperative cultures (SPCs), and 4) clearly septic and 5) aseptic cases. In total, 268 archived synovial fluid samples from 195 patients who underwent acute/chronic revision total hip or knee arthroplasty were included. Cases were classified according to the International Consensus Meeting 2018 criteria. JI panel evaluation of synovial fluid was performed, and the results were compared with cultures. Results: The JI panel detected microorganisms in 7/48 (14.5%) and 15/67 (22.4%) cases related to UNCs and SPCs, respectively, but not in cases of UPCs. The correlation between JI panel detection and infection classification criteria for early/late acute and chronic PJI was 46.6%, 73%, and 40%, respectively. Overall, the JI panel identified 12.6% additional microorganisms and three new species. The JI panel pathogen identification showed a sensitivity and specificity of 41.4% (95% confidence interval (CI) 33.7 to 49.5) and 91.1% (95% CI 84.7 to 94.9), respectively. In total, 19/195 (9.7%) could have been managed differently and more accurately upon JI panel evaluation. Conclusion: Despite its microbial limitation, JI panel demonstrated clinical usefulness by complementing the traditional methods based on multiple cultures, particularly in PJI with unclear microbiological results.

3.
Skin Res Technol ; 30(3): e13622, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38500350

RESUMO

BACKGROUND AND OBJECTIVE: Skin thermal diffusivity plays a crucial role in various applications, including laser therapy and cryogenic skin cooling.This study investigates the correlation between skin thermal diffusivity and two important skin parameters, melanin content and erythema, in a cohort of 102 participants. METHODS: An in-house developed device based on transient temperature measurement was used to assess thermal diffusivity at different body locations. Melanin content and erythema were measured using a colorimeter. Statistical analysis was performed to examine potential correlations. RESULTS: The results showed that the measured thermal diffusivity values were consistent with previous reports, with variations observed among subjects. No significant correlation was found between thermal diffusivity and melanin content or erythema. This suggests that other factors, such as skin hydration or epidermis thickness, may have a more dominant influence on skin thermal properties. CONLCUSION: This research provides valuable insights into the complex interplay between skin thermal properties and physiological parameters, with potential implications for cosmetic and clinical dermatology applications.


Assuntos
Melaninas , Pigmentação da Pele , Humanos , Pele/diagnóstico por imagem , Eritema , Epiderme
4.
J Bone Joint Surg Am ; 106(11): 941-949, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38512965

RESUMO

BACKGROUND: Osseointegration is essential for the long-term survival of cementless femoral stems and is dependent on periprosthetic bone quality and correct implantation technique. The aim of this study was to evaluate the 3-dimensional long-term fixation patterns of, and bone microarchitecture around, cementless hip stems. METHODS: Four specimens with varying degrees of bone quality and fixation characteristics from body donors who had received Alloclassic Zweymüller hip stems during their lifetime (mean time in situ at the time of death: 12.73 years) were evaluated with use of radiographs, high-resolution computed tomography (CT) scans, and hard-tissue histology. The CT voxel size was 85 µm, and the following parameters were calculated: total bone volume, total bone volume fraction, trabecular bone volume, trabecular bone volume fraction, cortical bone volume, cortical bone volume fraction, and cortical thickness. Bone-implant contact and canal fill index values for each Gruen zone of the specimens were calculated with use of histological samples. RESULTS: Femoral stems with apparently good cortical contact on clinical radiographs showed higher values for cortical bone volume, trabecular bone volume, and cortical thickness in the high-resolution CT analysis than femoral stems with apparently weak cortical contact on clinical radiographs. Based on the histological evaluation, the mean bone-implant contact ranged from 22.94% to 57.24% and the mean canal fill index ranged from 52.33% to 69.67% among the specimens. CONCLUSIONS: This study demonstrated different osseointegration patterns of cementless femoral stems on the basis of radiographs, high-resolution CT scans, and histological evaluation. Femora with high cortical bone volume and cortical thickness were associated with higher canal fill indices, whereas femora with low cortical bone volume and cortical thickness had lower canal fill indices and showed a characteristic corner-anchorage pattern. CLINICAL RELEVANCE: Osseointegration patterns and thus the long-term survival of cementless femoral stems are dependent on cortical bone volume and cortical thickness.


Assuntos
Fêmur , Prótese de Quadril , Osseointegração , Tomografia Computadorizada por Raios X , Osseointegração/fisiologia , Humanos , Fêmur/diagnóstico por imagem , Masculino , Feminino , Idoso , Artroplastia de Quadril/métodos , Pessoa de Meia-Idade , Desenho de Prótese , Imageamento Tridimensional
5.
Artigo em Inglês | MEDLINE | ID: mdl-38411348

RESUMO

BACKGROUND: Artificial intelligence (AI) shows promising potential to enhance human decision-making as synergistic augmented intelligence (AuI), but requires critical evaluation for skin cancer screening in a real-world setting. OBJECTIVES: To investigate the perspectives of patients and dermatologists after skin cancer screening by human, artificial and augmented intelligence. METHODS: A prospective comparative cohort study conducted at the University Hospital Basel included 205 patients (at high-risk of developing melanoma, with resected or advanced disease) and 8 dermatologists. Patients underwent skin cancer screening by a dermatologist with subsequent 2D and 3D total-body photography (TBP). Any suspicious and all melanocytic skin lesions ≥3 mm were imaged with digital dermoscopes and classified by corresponding convolutional neural networks (CNNs). Excisions were performed based on dermatologist's melanoma suspicion, study-defined elevated CNN risk-scores and/or melanoma suspicion by AuI. Subsequently, all patients and dermatologists were surveyed about their experience using questionnaires, including quantification of patient's safety sense following different examinations (subjective safety score (SSS): 0-10). RESULTS: Most patients believed AI could improve diagnostic performance (95.5%, n = 192/201). In total, 83.4% preferred AuI-based skin cancer screening compared to examination by AI or dermatologist alone (3D-TBP: 61.3%; 2D-TBP: 22.1%, n = 199). Regarding SSS, AuI induced a significantly higher feeling of safety than AI (mean-SSS (mSSS): 9.5 vs. 7.7, p < 0.0001) or dermatologist screening alone (mSSS: 9.5 vs. 9.1, p = 0.001). Most dermatologists expressed high trust in AI examination results (3D-TBP: 90.2%; 2D-TBP: 96.1%, n = 205). In 68.3% of the examinations, dermatologists felt that diagnostic accuracy improved through additional AI-assessment (n = 140/205). Especially beginners (<2 years' dermoscopic experience; 61.8%, n = 94/152) felt AI facilitated their clinical work compared to experts (>5 years' dermoscopic experience; 20.9%, n = 9/43). Contrarily, in divergent risk assessments, only 1.5% of dermatologists trusted a benign CNN-classification more than personal malignancy suspicion (n = 3/205). CONCLUSIONS: While patients already prefer AuI with 3D-TBP for melanoma recognition, dermatologists continue to rely largely on their own decision-making despite high confidence in AI-results. TRIAL REGISTRATION: ClinicalTrials.gov (NCT04605822).

6.
J Mech Behav Biomed Mater ; 150: 106333, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38134586

RESUMO

The fibro-cartilaginous labrum surrounds the acetabular rim and is important for hip joint stability and sealing. Sealing may be enhanced by swelling pressure within the normal labrum. Swelling of the degenerated or torn labrum might occur and potentially contribute to the development of osteoarthritis, through altered load transmission. This study aimed to characterize the three-dimensional swelling behaviour, the collagen fiber orientation and spatial proteoglycan distribution of the bovine acetabular labrum. Specimens were harvested from bovine donors (192-652 days, male, n = 6 donors). Structure was analyzed by scanning electron microscopy, histology, and dimethylmethylene blue assay. Specimen dimensions were measured before and after incubation in phosphate buffered saline to assess the swelling. Results showed that the articulating surface is composed of a collagen mesh network. Collagen fiber bundles showed a low degree of alignment close to the surface and were circumferentially aligned in the deep tissue. Proteoglycans were identified clustered between the collagen bundles. Glycosaminoglycan content was 10 x lower than that of cartilage (23.1 ± 6.4 compared to 299.5 ± 19.1 µg/mg dry weight) with minor regional differences. Specimens swelled significantly more in the orthogonal direction (swelling ratio 124.7 ± 10.2%) compared to the swelling parallel to the articulating surface (108.8 ± 6.1% and 102.8 ± 4.1%). In the deep tissue, swelling was also restricted in the main collagen fiber bundle direction (circumferentially), with a swelling ratio of 109.5 ± 4.0% in the main fiber bundle direction compared to 126.8 ± 7.3 % and 122.3 ± 5.8% radially. The findings demonstrate that the labrum shows anisotropic swelling properties, which reflect the anisotropy in the tissue structure and inter-fiber localisation of proteoglycans.


Assuntos
Acetábulo , Cartilagem Articular , Masculino , Animais , Bovinos , Anisotropia , Cartilagem Articular/patologia , Articulação do Quadril , Colágeno , Proteoglicanas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA