1.
J Pharm Biomed Anal ; 215: 114755, 2022 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-35430411

RESUMO

Chemometrics applied to spectroscopic measurements such as near-infrared are gaining more and more importance for quality control of pharmaceutical products. Handheld near-infrared devices show great promise as a medicines quality screening technique for post-marketing surveillance. These devices are able to detect substandard and falsified medicines in pharmaceutical supply chains and enable rapid action before these medicines reach patients. The instrumental and environmental changes, expected or not, can adversely affect the analytical performances of prediction models developed for routine applications. Based on a previous study, PLS prediction models were developed and validated on three similar handheld NIR transmission spectrophotometers of the same model and from same company. These models have shown to be effective in analyzing metformin tablet samples, but significant spectral differences between handheld systems complicated their deployment for routine analysis. In this study, different strategies have been applied and compared to correct the instrumental variations, including global modelling (GM) and calibration transfer methods (Direct Standardization, DS; Spectral Space Transformation, SST and Slope/Bias correction, SBC), considering the RMSEP and the accuracy profile as assessment criteria. The transfer methods showed good capabilities to maintain the predictive performances comparable to that of the global modelling approach, except for a remaining slight bias. This approach is interesting since very few standardization samples are required to develop an adequate transfer model. GM, SST and SBC were able to correct/handle drifts in the spectral responses of different handheld instruments and thus may help to avoid the need for a long, laborious, and costly full recalibration process due to inter-instrument variations.


Assuntos
Medicamentos Falsificados , Espectroscopia de Luz Próxima ao Infravermelho , Calibragem , Medicamentos Falsificados/análise , Humanos , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Comprimidos/química
2.
Int J Pharm ; 612: 121373, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-34906650

RESUMO

The distributional homogeneity of chemicals is a key parameter of solid pharmaceutical formulations. Indeed, it may affect the efficacy of the drug and consequently its safety. Chemical imaging offers a unique insight enabling the visualisation of the different constituents of a pharmaceutical tablet. It allows identifying ingredients poorly distributed offering the possibility to optimize the process parameters or to adapt characteristics of incoming raw materials to increase the final product quality. Among the available chemical imaging tools, Raman imaging is one of the most widely used since it offers a high spatial resolution with well-resolved peaks resulting in a high spectral specificity. However, Raman imaging suffers from sample autofluorescence and long acquisition times. Recently commercialised, laser direct infrared reflectance imaging (LDIR) is a quantum cascade laser (QCL) based imaging technique that offers the opportunity to rapidly analyse samples. In this study, a typical pharmaceutical formulation blend composed of two active pharmaceutical ingredients and three excipients was aliquoted at different mixing timepoints. The collected aliquots were tableted and analysed using both Raman and LDIR imaging. The distributional homogeneity indexes of one active ingredient image were then computed and compared. The results show that both techniques achieved similar conclusions. However, the analysis times were drastically different. While Raman imaging required a total analysis time of 4 h per tablet to obtain the distribution map of acetylsalicylic acid with a step size of 100 µm, it only took 7.5 min to achieve the same result with LDIR. The results obtained in the present study show that LDIR is a promising technique for the analysis of pharmaceutical formulations and that it could be a valuable tool when developing new pharmaceutical formulations.


Assuntos
Química Farmacêutica , Análise Espectral Raman , Composição de Medicamentos , Lasers , Comprimidos
3.
J Pharm Biomed Anal ; 194: 113761, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-33234414

RESUMO

The proliferation of falsified medicines can cause serious public health issues, particularly in the context of a global pandemic such as the actual COVID-19 pandemic. Our study involved eight chloroquine phosphate medicines seized in Cameroon, Democratic Republic of Congo and Niger during March and May 2020. These suspect samples were first analyzed in a screening phase using field tools such as handheld Raman spectroscopy (TruScan) and then in a confirmation phase using laboratory tools such as hyperspectral Raman imaging and High Performance Liquid Chromatography (HPLC). The results confirmed the falsified nature of the samples, highlighting the presence of metronidazole at low dose in four samples (16.6, 15.2, 15.2 and 14.5 mg/tab), too low levels of chloroquine in two samples (2.4 and 20.2 mg/tab), and substitution of chloroquine phosphate by paracetamol in one sample (255.7 mg/tab). The results also confirmed that four samples had been adulterated with paracetamol in trace amounts and two of them presented traces of chloramphenicol.


Assuntos
COVID-19/epidemiologia , Cloroquina/análogos & derivados , Medicamentos Falsificados/análise , Pandemias , Análise Espectral Raman/métodos , Anti-Inflamatórios não Esteroides/análise , Anti-Inflamatórios não Esteroides/uso terapêutico , Antimaláricos/análise , Antimaláricos/uso terapêutico , Cloroquina/análise , Cloroquina/uso terapêutico , Cromatografia Líquida de Alta Pressão/métodos , Medicamentos Falsificados/uso terapêutico , Humanos , Comprimidos , Tratamento Farmacológico da COVID-19
4.
J Pharm Biomed Anal ; 186: 113319, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32361470

RESUMO

In this study, adipose-derived stem cells (ASCs) are used to produce 3D bone grafts. The safety and the feasibility of using these bone grafts have been already showed and quality controls are already implemented. However, a cheaper, fast and non-destructive technique is required to monitor the osteogenic differentiation process. Here, the use of Raman imaging to monitor the synthesis of the extracellular matrix and its progressive mineralization occurring during the osteogenic differentiation process is investigated for the first time on a 3D in forming bone tissue. The attention was focused on Raman bands related to this matrix belonging to phosphate, phenylalanine and hydroxyproline, which are very distinctive and intense. The kinetic of the osteogenic differentiation process was first compared between a 2D and a 3D forming bone tissue. It was observed that the kinetics of the osteogenic differentiation process is slower in 3D in forming bone tissue. In a second step, an evaluation of the reliability of the Raman imaging method was performed including a study of the influence of the harvest biopsies position on the forming 3D bone tissue. The repeatability and the specificity of this method were also demonstrated. In a last step, several batches of ASCs were cultured and analyzed in 3D at different time points using Raman imaging. From the mean Raman spectra, mineral to matrix ratios (MTMR) were determined and used to evaluate the formation of mineral deposits accompanying the extracellular matrix synthesis which is indicative of an ongoing osteogenic differentiation process. These ratios peaked between the day 35 and 49. This observation was very interesting since it corresponds to the time at which the 3D bone grafts are used for the patient surgery. To conclude, Raman imaging allowed fast acquisition and time-resolved monitoring in vitro of the mineralization of extracellular matrix during osteogenic differentiation.


Assuntos
Tecido Adiposo/citologia , Osteogênese/fisiologia , Análise Espectral Raman/métodos , Células-Tronco/citologia , Osso e Ossos/fisiologia , Diferenciação Celular/fisiologia , Células Cultivadas , Matriz Extracelular/fisiologia , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Fatores de Tempo
5.
Talanta ; 207: 120306, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31594606

RESUMO

Handheld Raman spectroscopy is actually booming. Recent devices improvements aim at addressing the usual Raman spectroscopy issues: fluorescence with shifted-excitation Raman difference spectroscopy (SERDS), poor sensitivity with surface enhanced Raman scattering (SERS) and information only about the sample surface with spatially offset Raman spectroscopy (SORS). While qualitative performances of handheld devices are generally well established, the quantitative analysis of pharmaceutical samples remains challenging. The aim of this study was to compare the quantitative performances of three commercially available handheld Raman spectroscopy devices. Two of them (TruScan and IDRaman mini) are equipped with a 785 nm laser wavelength and operate in a conventional backscattering mode. The IDRaman has the Orbital Raster Scanning (ORS) option to increase the analyzed surface. The third device (Resolve) operates with an 830 nm laser wavelength both in backscattering and in SORS modes. The comparative study was carried out on ibuprofen-mannitol-microcrystalline cellulose ternary mixtures. The concentration of ibuprofen ranged from 24 to 52% (w/w) while the proportions of the two excipients were varied to avoid cross-correlation as much as possible. Analyses were performed either directly through a glass vial or with the glass vial in an opaque polypropylene flask, using a validated FT-NIR spectroscopy method as a reference method. Chemometric analyses were carried out with the Partial Least Squares Regression (PLS-R) algorithm. The quantitative models were validated using the total error approach and the ICH Q2 (R1) guidelines with ±â€¯15% as acceptance limits.


Assuntos
Preparações Farmacêuticas/análise , Embalagem de Produtos , Espectrofotometria/instrumentação , Análise Espectral Raman/instrumentação , Vidro , Ibuprofeno/análise , Polipropilenos
6.
J Pharm Biomed Anal ; 180: 113015, 2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-31865206

RESUMO

Within the family of serotonin (5-HT) receptors, the 5-HT1A subtype is particularly interesting as it may be involved in various physiological processes or psychological disorders. The p-[18F]MPPF, a highly selective 5-HT1A antagonist, is used for in vivo studies in human or animal by means of positron emission tomography (PET) [1]. In order to selectively extract p-[18F]MPPF and its main metabolites from plasma, molecularly imprinted polymer (MIP) was prepared against these compounds by using the p-MPPF as template. For the control of the selectivity, non-imprinted polymer (NIP) was also synthesized without template. The MIP sorbent, packed in disposable extraction cartridges (DECs), was then evaluated as molecularly imprinted solid-phase extraction (MISPE) prior to the LC determination. The conditions of extraction were evaluated in order to obtain the highest selective retention of the p-[18F]MPPF and its metabolites on this MIP. The MIP selectivity was exploited in the loading and washing steps by adjusting the pH of plasma samples at a suitable value and by selecting mixtures for the washing step to limit the contribution of non-specific interactions. Other important parameters involved in the conditioning and elution steps were also studied. Finally, a pre-validation was carried out with optimal extraction conditions to demonstrate the performance of this MISPE-LC method as a generic method in the context of evaluation of new MISPE for p-[18F]MPPF and its potential for metabolites extraction from human plasma.


Assuntos
Aminopiridinas/sangue , Benzamidas/sangue , Radioisótopos de Flúor/química , Piperazinas/sangue , Polímeros/química , Receptor 5-HT1A de Serotonina/metabolismo , Antagonistas do Receptor 5-HT1 de Serotonina/sangue , Técnicas Biossensoriais , Cromatografia Líquida de Alta Pressão , Humanos , Concentração de Íons de Hidrogênio , Metaboloma , Metacrilatos/química , Impressão Molecular/métodos , Estrutura Molecular , Extração em Fase Sólida/métodos
7.
Talanta ; 202: 469-478, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31171209

RESUMO

Over the last decade, the growth of the global pharmaceutical market has led to an overall increase of substandard and falsified drugs especially on the African market (or emerging countries). Recently, several methods using handheld/portable vibrational spectroscopy have been developed for rapid and on-field drug analysis. The objective of this work was to evaluate the performances of various NIR and Raman handheld spectrophotometers in specific brand identification of medicines through their primary packaging. Three groups of drug samples (artemether-lumefantrine, paracetamol and ibuprofen) were used in tablet or capsule forms. In order to perform a critical comparison, the analytical performances of the two analytical systems were compared statistically using three methods: hierarchical clustering algorithm (HCA), data-driven soft independent modelling of class analogy (DD-SIMCA) and hit quality index (HQI). The overall results show good detection abilities for NIR systems compared to Raman systems based on Matthews's correlation coefficients, generally close to one. Raman systems are less sensitive to the physical state of the samples than the NIR systems, it also suffers of the auto-fluorescence phenomenon and the signal of highly dosed active pharmaceutical ingredient (e.g. paracetamol or lumefantrine) may mask the signal of low-dosed and weaker Raman active compounds (e.g. artemether). Hence, Raman systems are less effective for specific product identification purposes but are interesting in the context of falsification because they allow a visual interpretation of the spectral signature (presence or absence of API).


Assuntos
Medicamentos Falsificados/análise , Algoritmos , Raios Infravermelhos , Análise Espectral Raman
8.
Talanta ; 186: 8-16, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-29784422

RESUMO

The analysis of serum samples by surface-enhanced Raman spectroscopy (SERS) has gained ground over the last few years. However, the stabilisation of colloids by the proteins contained in these samples has restricted their use in common practice, unless antibodies or aptamers are used. Therefore, this work was dedicated to the development of a SERS methodology allowing the analysis of serum samples in a simple and easy-to-implement way. This approach was based on the pre-aggregation of the colloid with a salt solution. Gold nanoparticles (AuNPs) were used as the SERS substrate and, owing to its physiopathological importance, dopamine was chosen as a model to implement the SERS approach. The presence of this neurotransmitter could be determined in the concentration range 0.5-50 ppm (2.64-264 µM) in the culture medium of PC-12 cells, with a R2 of 0.9874, and at even lower concentrations (0.25 ppm, 1.32 µM) in another matrix containing fewer proteins. Moreover, the effect of calcium and potassium on the dopamine exocytosis from PC-12 cells was studied. Calcium was shown to have a predominant and dose-dependant effect. Finally, PC-12 cells were exposed to dexamethasone in order to increase their biosynthesis and release of dopamine. This increase was monitored with the developed SERS approach.


Assuntos
Meios de Cultura/química , Dopamina/sangue , Ouro/química , Nanopartículas Metálicas/química , Animais , Células Cultivadas , Células PC12 , Ratos , Análise Espectral Raman , Propriedades de Superfície
9.
Analyst ; 143(6): 1492-1501, 2018 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-29488516

RESUMO

It is common practice nowadays to associate the measurement uncertainty to the measurand, in order to judge the quality of a result related to the measurement process. However, the improvement of this parameter as well as the adaptation of its estimation modes always remain an analytical challenge, especially in chemical testing. In this paper, we outline a measurement uncertainty estimation mode based on the one-point linear calibration equation to fully establish a "bottom-up" approach for estimating the measurement uncertainty of a multi-point calibration-based HPLC-UV quantitative method. To demonstrate this estimation mode, we have followed as an example of interest the influences resulting from the simultaneous determination of two biochemical indicators, namely the human plasma vitamers retinol and α-tocopherol. Results from this estimation showed consistency when compared to those obtained from the validation-based alternative method, where the relative expanded uncertainties were found, at a 95% confidence level, to be less than 15% for the low concentration ranges of the two molecules. However, the modelling approach shows all the benefits of its use to identify and quantify all the uncertainty contributions arising from the different steps of the analytical process and seems to be quite achievable for comparative HPLC methods.


Assuntos
Cromatografia Líquida de Alta Pressão , Vitamina A/análise , Vitamina E/análise , Calibragem , Humanos , Incerteza , Vitamina A/sangue , Vitamina E/sangue
10.
J Pharm Biomed Anal ; 147: 458-472, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28688617

RESUMO

Surface-enhanced Raman spectroscopy (SERS) is a sensitive analytical tool used in the pharmaceutical field in recent years. SERS keeps all the advantages of classical Raman spectroscopy while being is more sensitive allowing its use for the detection and the quantification of low-dose substances contained in pharmaceutical samples. However, the analytical performance of SERS is limited due to the difficulty to implement a quantitative methodology correctly validated. Nevertheless, some studies reported the development of SERS quantitative methods especially in pharmaceutical approaches. In this context, this review presents the main concepts of the SERS technique. The different steps that need to be applied to develop a SERS quantitative method are also deeply described. The last part of the present manuscript gives a critical overview of the different SERS pharmaceutical applications that were developed for a non-exhaustive list of pharmaceutical compounds with the aim to highlights the validation criteria for each application.


Assuntos
Química Farmacêutica/métodos , Preparações Farmacêuticas/análise , Análise Espectral Raman/métodos , Nanopartículas/análise , Nanopartículas/química , Preparações Farmacêuticas/química
11.
J Chromatogr A ; 1515: 209-217, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28811100

RESUMO

Nowadays, many efforts are devoted to improve analytical methods regarding efficiency, analysis time and greenness. In this context, Supercritical Fluid Chromatography (SFC) is often regarded as a good alternative over Normal Phase Liquid Chromatography (NPLC). Indeed, modern SFC separations are fast, efficient with suitable quantitative performances. Moreover, the hyphenation of SFC to mass spectrometry (MS) provides additional gains in specificity and sensitivity. The present work aims at the determination of vitamin D3 by SFC-MS for routine Quality Control (QC) of medicines specifically. Based on the chromatographic parameters previously defined in SFC-UV by Design of Experiments (DoE) and Design Space methodology, the method was adapted to work under isopycnic conditions ensuring a baseline separation of the compounds. Afterwards, the response provided by the MS detector was optimized by means of DoE methodology associated to desirability functions. Using these optimal MS parameters, quantitative performances of the SFC-MS method were challenged by means of total error approach method validation. The resulting accuracy profile demonstrated the full validity of the SFC-MS method. It was indeed possible to meet the specification established by the European Medicines Agency (EMA) (i.e. 95.0 - 105.0% of the API content) for a dosing range corresponding to at least 70.0-130.0% of the API content. These results highlight the possibility to use SFC-MS for the QC of medicine and obviously support the switch to greener analytical methods.


Assuntos
Colecalciferol/análise , Cromatografia com Fluido Supercrítico/métodos , Espectrometria de Massas/métodos , Óleos/análise , Composição de Medicamentos , Controle de Qualidade , Sensibilidade e Especificidade
12.
Int J Pharm ; 530(1-2): 249-255, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28746834

RESUMO

The development of a quantitative method determining the crystalline percentage in an amorphous solid dispersion is of great interest in the pharmaceutical field. Indeed, the crystalline Active Pharmaceutical Ingredient transformation into its amorphous state is increasingly used as it enhances the solubility and bioavailability of Biopharmaceutical Classification System class II drugs. One way to produce amorphous solid dispersions is the Hot-Melt Extrusion (HME) process. This study reported the development and the comparison of the analytical performances of two techniques, based on backscattering and transmission Raman spectroscopy, determining the crystalline remaining content in amorphous solid dispersions produced by HME. Principal Component Analysis (PCA) and Partial Least Squares (PLS) regression were performed on preprocessed data and tended towards the same conclusions: for the backscattering Raman results, the use of the DuoScan™ mode improved the PCA and PLS results, due to a larger analyzed sampling volume. For the transmission Raman results, the determination of low crystalline percentages was possible and the best regression model was obtained using this technique. Indeed, the latter acquired spectra through the whole sample volume, in contrast with the previous surface analyses performed using the backscattering mode. This study consequently highlighted the importance of the analyzed sampling volume.


Assuntos
Composição de Medicamentos , Análise Espectral Raman , Química Farmacêutica , Estudos de Viabilidade , Solubilidade
13.
Talanta ; 171: 45-52, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28551152

RESUMO

Since the Food and Drug Administration (FDA) published a guidance based on the Process Analytical Technology (PAT) approach, real-time analyses during manufacturing processes are in real expansion. In this study, in-line Raman spectroscopic analyses were performed during a Hot-Melt Extrusion (HME) process to determine the Active Pharmaceutical Ingredient (API) content in real-time. The method was validated based on a univariate and a multivariate approach and the analytical performances of the obtained models were compared. Moreover, on one hand, in-line data were correlated with the real API concentration present in the sample quantified by a previously validated off-line confocal Raman microspectroscopic method. On the other hand, in-line data were also treated in function of the concentration based on the weighing of the components in the prepared mixture. The importance of developing quantitative methods based on the use of a reference method was thus highlighted. The method was validated according to the total error approach fixing the acceptance limits at ±15% and the α risk at ±5%. This method reaches the requirements of the European Pharmacopeia norms for the uniformity of content of single-dose preparations. The validation proves that future results will be in the acceptance limits with a previously defined probability. Finally, the in-line validated method was compared with the off-line one to demonstrate its ability to be used in routine analyses.

14.
J Chromatogr A ; 1491: 171-181, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28242051

RESUMO

In the uprising context of green analytical chemistry, Supercritical Fluid Chromatography (SFC) is often suggested as an alternative to Normal Phase Liquid Chromatography. Indeed, SFC provides fast, efficient and green separations. In this report, the quantitative performances of SFC were challenged on a real-life case study: the Quality Control (QC) of vitamin D3. A rapid and green SFC method was optimized thanks to the Design of Experiments-Design Space (DoE-DS) methodology. It provided robust and high quality separation of the compounds within a 2min timeframe, using a gradient of ethanol as co-solvent of the carbon dioxide. The analytical method was fully validated according to the total error approach, demonstrating the compliance of the method to the specifications of U.S. Pharmacopeia (USP: 97.0-103.0%) and European Pharmacopeia (EP: 97.0-102.0%) for an interval of [50-150%] of the target concentration. In order to allow quantification of impurities using vitamin D3 as an external standard in SFC-UV, correction factors were determined and verified during method validation. Thus, accurate quantification of impurities was demonstrated at the specified levels (0.1 and 1.0% of the main compound) for a 70.0-130.0% dosing range. This work demonstrates the validity of an SFC method for the QC of vitamin D3 raw material and its application to real samples. Therefore, it supports the switch to a greener and faster separative technique as an alternative to NPLC in the pharmaceutical industry.


Assuntos
Colecalciferol/análise , Cromatografia com Fluido Supercrítico/métodos , Colecalciferol/química , Colecalciferol/normas , Contaminação de Medicamentos , Reprodutibilidade dos Testes
15.
Talanta ; 160: 754-760, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27591672

RESUMO

A new application of surface-enhanced Raman scattering (SERS) in the field of plant material analysis is proposed in this study. The aim was to monitor the release of anatabine by methyl jasmonate (MeJa) elicited Bright Yellow-2 (BY-2) cells. Gold nanoparticles (AuNps) were used as SERS substrate. The first step was to study the SERS activity of anatabine in a complex matrix comprising the culture medium and BY-2 cells. The second step was the calibration. This one was successfully performed directly in the culture medium in order to take into account the matrix effect, by spiking the medium with different concentrations of anatabine, leading to solutions ranging from 250 to 5000µgL(-1). A univariate analysis was performed, the intensity of a band situated at 1028cm(-1), related to anatabine, was plotted against the anatabine concentration. A linear relationship was observed with a R(2) of 0.9951. During the monitoring study, after the MeJa elicitation, samples were collected from the culture medium containing BY-2 cells at 0, 24h, 48h, 72h and 96h and were analysed using SERS. Finally, the amount of anatabine released in the culture medium was determined using the response function, reaching a plateau after 72h of 82µg of anatabine released/g of fresh weight (FW) MeJa elicited BY-2 cells.


Assuntos
Acetatos/farmacologia , Alcaloides/análise , Ciclopentanos/farmacologia , Nicotiana/citologia , Oxilipinas/farmacologia , Piridinas/análise , Alcaloides/química , Alcaloides/metabolismo , Cromatografia Líquida , Meios de Cultura/análise , Ouro/química , Espectrometria de Massas , Nanopartículas Metálicas/química , Piridinas/química , Piridinas/metabolismo , Análise Espectral Raman
16.
J Health Popul Nutr ; 35(1): 26, 2016 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-27542826

RESUMO

BACKGROUND: Groundwater drawn from shallow tubewells in Bangladesh is often polluted by nearby pit latrines, which are commonly used toilets in rural and sub-urban areas of the country. METHODS: To determine the minimum safe distance of a tubewell from a pit latrine in different hydrogeological conditions of Bangladesh, 20 monitoring wells were installed at three study sites (Manda, Mohanpur and Bagmara) with the vertical and horizontal distances ranging from 18-47 to 2-15 m, respectively. Water samples were collected three times in three seasons and tested for faecal coliforms (FC) and faecal streptococci (FS) as indicators of contamination. Soil samples were analysed for texture, bulk density and hydraulic conductivity following standard procedures. Sediment samples were collected to prepare lithological logs. RESULTS: When the shallow aquifers at one of the three sites (Mohanpur) were overlained by 18-23-m-thick aquitards, the groundwater of the monitoring wells was found contaminated with a lateral and vertical distances of 2 and 31 m, respectively. However, where the aquitard was only 9 m thick, contamination was found up to lateral and vertical distances of 4.5 and 40.5 m, respectively. The soil textures of all the sites were mainly composed of loam and sandy loam. The hydraulic conductivities in the first aquifer at Manda, Mohanpur and Bagmara were 5.2-7.3, 8.2 and 1.4-15.7 m/h, respectively. CONCLUSIONS: The results showed that the safe distance from the tubewell to the pit latrine varied from site to site depending on the horizontal and vertical distances of the tubewell as well as hydrogeological conditions of a particular area.


Assuntos
Fenômenos Geológicos , Água Subterrânea , Banheiros , Abastecimento de Água , Poços de Água , Áreas Alagadas , Bangladesh , Monitoramento Ambiental , Humanos
17.
J Pharm Biomed Anal ; 128: 382-390, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27343901

RESUMO

African populations use traditional medicines in their initial attempt to treat a range of diseases. Nevertheless, accurate knowledge of the composition of these drugs remains a challenge in terms of ensuring the health of population and in order to advance towards improved traditional medicines (ITMs). In this paper chromatographic methods were developed for qualitative and quantitative analyses of a per os antimalarial ITM containing Garcinia kola. The identified analytical markers were used to establish TLC and HPLC fingerprints. G. kola seeds were analysed by HPLC to confirm the identity of the extract used by the Congolese manufacturer in the ITM. The main compounds (GB1, GB2, GB-1a and Kolaflavanone) were isolated by preparative TLC and identified by UPLC-MS and NMR. For the quantification of the major compound GB1, a simple and rapid experimental design was applied to develop an LC method, and then its validation was demonstrated using the total error strategy with the accuracy profile as a decision tool. The accurate results were observed within 0.14-0.45mg/mL range of GB1 expressed as naringenin. The extracts used in several batches of the analysed oral solutions contained GB1 (expressed as naringenin) within 2.04-2.43%. Both the fingerprints and the validated LC-DAD were found suitable for the quality control of G. kola-based raw material and finished products, respectively.


Assuntos
Antimaláricos/análise , Biflavonoides/análise , Cromatografia Líquida de Alta Pressão/métodos , Garcinia kola/química , Extratos Vegetais/química , Antimaláricos/isolamento & purificação , Biflavonoides/isolamento & purificação , Flavanonas/análise , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Sementes/química
18.
Talanta ; 154: 392-9, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27154691

RESUMO

When developing a new formulation, the development, calibration and validation steps of analytical methods based on vibrational spectroscopy are time-consuming. For each new formulation, real samples must be produced and a "reference method" must be used in order to determine the Active Pharmaceutical Ingredient (API) content of each sample. To circumvent this issue, the paper presents a simple approach based on the film-casting technique used as a calibration tool in the framework of hot-melt extrusion process. Confocal Raman microscopic method was successfully validated for the determination of itraconazole content in film-casting samples. Then, hot-melt extrusion was carried out to produce real samples in order to confront the results obtained with confocal Raman microscopy and Ultra High Performance Liquid Chromatography (UHPLC). The agreement between both methods was demonstrated using a comparison study based on the Bland and Altman's plot.

19.
Anal Chim Acta ; 888: 118-25, 2015 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-26320966

RESUMO

Bisphenol A (BPA) is well known for its use in plastic manufacture and thermal paper production despite its risk of health toxicity as an endocrine disruptor in humans. Since the publication of new legislation regarding the use of BPA, manufacturers have begun to replace BPA with other phenolic molecules such as bisphenol F (BPF) and bisphenol B (BPB), but there are no guarantees regarding the health safety of these compounds at this time. In this context, a very simple, cheap and fast surface-enhanced Raman scattering (SERS) method was developed for the sensitive detection of these molecules in spiked tap water solutions. Silver nanoparticles were used as SERS substrates. An original strategy was employed to circumvent the issue of the affinity of bisphenols for metallic surfaces and the silver nanoparticles surface was functionalized using pyridine in order to improve again the sensitivity of the detection. Semi-quantitative detections were performed in tap water solutions at a concentrations range from 0.25 to 20 µg L(-1) for BPA and BPB and from 5 to 100 µg L(-1) for BPF. Moreover, a feasibility study for performing a multiplex-SERS detection of these molecules was also performed before successfully implementing the developed SERS method on real samples.


Assuntos
Compostos Benzidrílicos/análise , Água Potável/análise , Disruptores Endócrinos/análise , Fenóis/análise , Análise Espectral Raman/métodos , Poluentes Químicos da Água/análise , Estudos de Viabilidade , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Papel , Prata/química , Propriedades de Superfície
20.
J Pharm Biomed Anal ; 111: 21-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25828509

RESUMO

Poor quality antimalarial drugs are one of the public's major health problems in Africa. The depth of this problem may be explained in part by the lack of effective enforcement and the lack of efficient local drug analysis laboratories. To tackle part of this issue, two spectroscopic methods with the ability to detect and to quantify quinine dihydrochloride in children's oral drops formulations were developed and validated. Raman and near infrared (NIR) spectroscopy were selected for the drug analysis due to their low cost, non-destructive and rapid characteristics. Both of the methods developed were successfully validated using the total error approach in the range of 50-150% of the target concentration (20%W/V) within the 10% acceptance limits. Samples collected on the Congolese pharmaceutical market were analyzed by both techniques to detect potentially substandard drugs. After a comparison of the analytical performance of both methods, it has been decided to implement the method based on NIR spectroscopy to perform the routine analysis of quinine oral drop samples in the Quality Control Laboratory of Drugs at the University of Kinshasa (DRC).


Assuntos
Antimaláricos/química , Bioensaio/métodos , Soluções Farmacêuticas/análise , Soluções Farmacêuticas/química , Quinina/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise Espectral Raman/métodos , Administração Oral , África , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...