Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Environ Sci Technol ; 44(5): 1713-9, 2010 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20108959

RESUMO

Passive samplers such as the Polar Organic Chemical Integrative Sampler (POCIS) are useful tools for monitoring trace levels of polar organic chemicals in aquatic environments. The use of performance reference compounds (PRC) spiked into the POCIS adsorbent for in situ calibration may improve the semiquantitative nature of water concentration estimates based on this type of sampler. In this work, deuterium labeled atrazine-desisopropyl (DIA-d5) was chosen as PRC because of its relatively high fugacity from Oasis HLB (the POCIS adsorbent used) and our earlier evidence of its isotropic exchange. In situ calibration of POCIS spiked with DIA-d5 was performed, and the resulting time-weighted average concentration estimates were compared with similar values from an automatic sampler equipped with Oasis HLB cartridges. Before PRC correction, water concentration estimates based on POCIS data sampling rates from a laboratory calibration exposure were systematically lower than the reference concentrations obtained with the automatic sampler. Use of the DIA-d5 PRC data to correct POCIS sampling rates narrowed differences between corresponding values derived from the two methods. Application of PRCs for in situ calibration seems promising for improving POCIS-derived concentration estimates of polar pesticides. However, careful attention must be paid to the minimization of matrix effects when the quantification is performed by HPLC-ESI-MS/MS.


Assuntos
Água Doce/análise , Herbicidas/análise , Poluentes Químicos da Água/análise , Adsorção , Automação , Cromatografia Líquida de Alta Pressão , Monitoramento Ambiental/métodos , Cinética , Modelos Teóricos , Compostos Orgânicos/análise , Resíduos de Praguicidas/análise , Praguicidas/análise , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização por Electrospray
2.
Environ Sci Technol ; 43(9): 3054-60, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19534113

RESUMO

Concerns about indoor air quality and the potential effects on people living in these environments are increasing as more reports about the toxicities and the potential indoor air exposure levels of household-use chemicals and chemicals from housing and fumishing manufacture in air are being assessed. Gas chromatography/mass spectromery was used to confirm numerous airborne contaminants obtained from the analysis of semipermeable membrane devices deployed inside of 52 homes situated along the border between Arizona and Mexico. We also describe nontarget analytes in the organochlorine pesticide fractions of 12 of these homes; this fraction is also the most likely to contain the broadest scope of bioconcentratable chemicals accumulated from the indoor air. Approximately 400 individual components were identified, ranging from pesticides to a wide array of hydrocarbons, fragrances such as the musk xylenes, flavors relating to spices, aldehydes, alcohols, esters and phthalate esters, and other miscellaneous types of chemicals. The results presented in this study demonstrate unequivocally that the mixture of airborne chemicals present indoors is far more complex than previously demonstrated.


Assuntos
Poluentes Atmosféricos/análise , Ar/análise , Características de Residência , Compostos Orgânicos Voláteis/análise , Arizona , Cromatografia Gasosa , Membranas Artificiais , México , Praguicidas/análise , Bifenilos Policlorados/análise , Hidrocarbonetos Policíclicos Aromáticos/análise
3.
Environ Toxicol Chem ; 26(6): 1258-64, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17571693

RESUMO

Uptake of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) by triolein-containing semipermeable membrane devices (SPMDs) and by crucian carp (Carassius carassius) was studied in Taihu Lake, a shallow, freshwater lake in China. Crucian carp and SPMDs were deployed side by side for 32 d. The first-order uptake rate constants of individual PAHs and OCPs for the two matrices were calculated and compared to relate the amounts of chemicals accumulated by the matrices to dissolved water concentrations. On a wet-weight basis, total concentrations of PAHs and OCPs in crucian carp fillets averaged 49.5 and 13.6 ng/g, respectively, after the 32-d exposure, whereas concentrations in whole SPMDs averaged 716.9 and 62.3 ng/g, respectively. The uptake rate constants of PAHs and OCPs by SPMDs averaged seven- and fivefold higher, respectively, than those for crucian carp; however, the patterns of uptake rate constants derived from test chemical concentrations in the crucian carp and SPMDs were similar. Although equilibrium was not reached for some PAHs and OCPs during the 32-d exposure period, a reasonably good correlation between the concentration factors (CFs) and octanol/water partition coefficient (Kow) values of PAHs and OCPs in SPMDs (r = 0.86, p < 0.001) was observed when potential sorption to dissolved organic carbon was taken into account. Similar efforts to correlate the CFs and Kow values of PAHs and OCPs in crucian carp (r = 0.75, p < 0.001) were less successful, likely because of PAH metabolism by finfish. Overall, the present results suggest that SPMDs may serve as a surrogate for contaminant monitoring with fish in freshwater lake environments.


Assuntos
Peixes/metabolismo , Hidrocarbonetos Clorados/metabolismo , Membranas Artificiais , Praguicidas/metabolismo , Compostos Policíclicos/metabolismo , Poluentes Químicos da Água/metabolismo , Animais , China , Água Doce
5.
Environ Pollut ; 144(2): 371-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16554113

RESUMO

Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Resíduos de Praguicidas/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Raios Ultravioleta , Monitoramento Ambiental/métodos , Desenho de Equipamento , Reprodutibilidade dos Testes
6.
Environ Sci Technol ; 38(13): 3689-97, 2004 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15296322

RESUMO

Compound-specific carbon and hydrogen isotope analysis (CSCIA and CSHIA) has been increasingly used to study the source, transport, and bioremediation of organic contaminants such as petroleum hydrocarbons. In natural aquatic systems, dissolved contaminants represent the bioavailable fraction that generally is of the greatest toxicological significance. However, determining the isotopic ratios of waterborne hydrophobic contaminants in natural waters is very challenging because of their extremely low concentrations (often at sub-parts ber billion, or even lower). To acquire sufficient quantities of polycyclic aromatic hydrocarbons with 10 ng/L concentration for CSHIA, more than 1000 L of water must be extracted. Conventional liquid/liquid or solid-phase extraction is not suitable for such large volume extractions. We have developed a new approach that is capable of efficiently sampling sub-parts per billion level waterborne petroleum hydrocarbons for CSIA. We use semipermeable membrane devices (SPMDs) to accumulate hydrophobic contaminants from polluted waters and then recover the compounds in the laboratory for CSIA. In this study, we demonstrate, under a variety of experimental conditions (different concentrations, temperatures, and turbulence levels), that SPMD-associated processes do not induce C and H isotopic fractionations. The applicability of SPMD-CSIA technology to natural systems is further demonstrated by determining the delta13C and deltaD values of petroleum hydrocarbons present in the Pawtuxet River, RI. Our results show that the combined SPMD-CSIA is an effective tool to investigate the source and fate of hydrophobic contaminants in the aquatic environments.


Assuntos
Monitoramento Ambiental/métodos , Petróleo/análise , Poluentes Químicos da Água/análise , Alcanos/análise , Isótopos de Carbono/análise , Deutério/análise , Água Doce , Cromatografia Gasosa-Espectrometria de Massas , Membranas Artificiais , Hidrocarbonetos Policíclicos Aromáticos/análise , Rhode Island , Temperatura
7.
Environ Toxicol Chem ; 23(7): 1617-28, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15230313

RESUMO

We performed 20-d, flow-through exposures of lipid-containing semipermeable membrane devices (SPMDs) and Pacific oysters (Crassostrea gigas) to three concentrations (nominally 10, 100, and 250 ng/L) of a diverse mixture of polycyclic aromatic hydrocarbons (PAHs). Exposure water was seawater free of particulates larger than 0.1 microm. The results of these controlled laboratory studies demonstrated that SPMDs and oysters concentrate the same chemicals but that the relative amounts accumulated are different. For oysters, the 20-d mean (across treatments) concentration factors (CFs) of test compounds with log Kow < or = 4.8 were much lower (4.0- to 20-fold lower) than those of the same compounds in SPMDs. In contrast, the 20-d CFs of PAHs with log Kow > or = 5.6 in oysters from the low-level treatment were higher than the corresponding CFs for SPMDs. The CFs of these compounds in oysters from the low-level treatment ranged from approximately 3.0- to 13-fold higher than those in oysters from the high-level treatment. This physiologically mediated difference in oyster CFs appears to be linked to active feeding in the low-level treatment and to apparent toxicity-induced cessation of feeding (i.e., valve closure) in the high-level treatment. Because CFs for these compounds in oysters were not independent of exposure concentrations, it follows that tissue levels were not proportional to exposure concentration. However, both sampling approaches have advantages and disadvantages, and the appropriateness of their use depends on the goals of a given study.


Assuntos
Exposição Ambiental , Monitoramento Ambiental/métodos , Lipídeos/química , Membranas Artificiais , Compostos Orgânicos/análise , Ostreidae/metabolismo , Animais , Comportamento Alimentar , Cinética , Hidrocarbonetos Policíclicos Aromáticos/análise , Manejo de Espécimes , Poluentes Químicos da Água/toxicidade
8.
Environ Toxicol Chem ; 23(7): 1640-8, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15230316

RESUMO

Increasingly it is being realized that a holistic hazard assessment of complex environmental contaminant mixtures requires data on the concentrations of hydrophilic organic contaminants including new generation pesticides, pharmaceuticals, personal care products, and many chemicals associated with household, industrial, and agricultural wastes. To address this issue, we developed a passive in situ sampling device (the polar organic chemical integrative sampler [POCIS]) that integratively concentrates trace levels of complex mixtures of hydrophilic environmental contaminants, enables the determination of their time-weighted average water concentrations, and provides a method of estimating the potential exposure of aquatic organisms to the complex mixture of waterborne contaminants. Using a prototype sampler, linear uptake of selected herbicides and pharmaceuticals with log K(ow)s < 4.0 was observed for up to 56 d. Estimation of the ambient water concentrations of chemicals of interest is achieved by using appropriate uptake models and determination of POCIS sampling rates for appropriate exposure conditions. Use of POCIS in field validation studies targeting the herbicide diuron in the United Kingdom resulted in the detection of the chemical at estimated concentrations of 190 to 600 ng/L. These values are in agreement with reported levels found in traditional grab samples taken concurrently.


Assuntos
Monitoramento Ambiental/métodos , Compostos Orgânicos/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/instrumentação , Geografia , Biologia Marinha , Medição de Risco , Manejo de Espécimes , Reino Unido
9.
Environ Toxicol ; 19(4): 329-35, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15269903

RESUMO

Phytoremediation in a simulated crude oil spill was studied with a "minimalistic" approach. The SPMD-TOX paradigm-a miniature passive sorptive device to collect and concentrate chemicals and microscale tests to detect toxicity-was used to monitor over time the bioavailability and potential toxicity of an oil spill. A simulated crude oil spill was initiated on an intertidal freshwater grass-wetland along the St. Lawrence River southwest of Quebec City, Quebec, Canada. Several phytoremediation treatments were investigated; to dissipate and ameliorate the spill, treatments included nutrient amendments with inorganic nitrogen sources (ammonium nitrate and sodium nitrate) and phosphate (super triple phosphate) with and without cut plants, with natural attenuation (no phytoremedial treatment) as a control. Sequestered oil residues were bioavailable in all oil-treated plots in Weeks 1 and 2. Interestingly, the samples were colored and fluoresced under ultraviolet light. In addition, microscale tests showed that sequestered residues were acutely toxic and genotoxic, as well as that they induced hepatic P(450) enzymes. Analysis of these data suggested that polycyclic aromatic hydrocarbons were among the bioavailable residues sequestered. In addition, these findings suggested that the toxic bioavailable fractions of the oil spill and degradation products dissipated rapidly over time because after the second week the water column contained no oil or detectable degradation products in this riverine intertidal wetland. SPMD-TOX revealed no evidence of bioavailable oil products in Weeks 4, 6, 8, and 12. All phytoremediation efforts appeared to be ineffective in changing either the dissipation rate or the ability to ameliorate the oil toxicity. SPMD-TOX analysis of the water columns from these riverine experimental plots profiled the occurrence, dissipation, and influence of phytoremediation on the bioavailability and toxicity of oil products (parent or degradation products).


Assuntos
Petróleo/toxicidade , Testes de Toxicidade/métodos , Poluentes Químicos da Água/toxicidade , Animais , Biodegradação Ambiental , Disponibilidade Biológica , Cyperaceae/metabolismo , Citocromo P-450 CYP1A1/biossíntese , Monitoramento Ambiental/métodos , Corantes Fluorescentes , Sedimentos Geológicos/química , Ictaluridae/metabolismo , Medições Luminescentes , Membranas Artificiais , Testes de Mutagenicidade , Petróleo/metabolismo , Quebeque , Rios , Fatores de Tempo , Testes de Toxicidade/instrumentação , Raios Ultravioleta , Vibrio/genética , Vibrio/metabolismo , Movimentos da Água , Poluentes Químicos da Água/metabolismo
10.
Chemosphere ; 49(7): 703-15, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12431007

RESUMO

High performance liquid chromatography coupled with programmable fluorescence detection was employed for the determination of 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs) in water, sediment, and semipermeable membrane devices (SPMDs). Chromatographic separation using this analytical method facilitates selectivity, sensitivity (ppt levels), and can serve as a non-destructive technique for subsequent analysis by other chromatographic and spectroscopic techniques. Extraction and sample cleanup procedures were also developed for water, sediment, and SPMDs using various chromatographic and wet chemical methods. The focus of this publication is to examine the enrichment techniques and the analytical methodologies used in the isolation, characterization, and quantitation of 15 PPPAHs in different sample matrices.


Assuntos
Técnicas de Química Analítica/instrumentação , Poluentes Ambientais/análise , Sedimentos Geológicos/química , Membranas Artificiais , Hidrocarbonetos Policíclicos Aromáticos/análise , Água/química , Técnicas de Química Analítica/métodos , Cromatografia Líquida de Alta Pressão , Desenho de Equipamento , Espectrometria de Fluorescência
11.
Chemosphere ; 49(7): 717-29, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12431008

RESUMO

Semipermeable membrane devices (SPMDs) were employed to sample sediment pore water in static exposure studies under controlled laboratory conditions using (control pond and formulated) sediments fortified with 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs). The sediment fortification level of 750 ng/g was selected on the basis of what might be detected in a sediment sample from a contaminated area. The sampling interval consisted of 0, 4, 7, 14, and 28 days for each study. The analytical methodologies, as well as the extraction and sample cleanup procedures used in the isolation, characterization, and quantitation of 15 PPPAHs at different fortification levels in SPMDs, water, and sediment were reported previously (Williamson, M.S. Thesis, University of Missouri-Columbia, USA; Williamson et al., Chemosphere (This issue--PII: S0045-6535(02)00394-6)) and used for this project. Average (mean) extraction recoveries for each PPPAH congener in each matrix are reported and discussed. No procedural blank extracts (controls) were found to contain any PPPAH residues above the method quantitation limit, therefore, no matrix interferences were detected. The focus of this publication is to demonstrate the ability to sequester environmental contaminants, specifically PPPAHs, from sediment pore water using SPMDs and two different types of fortified sediment.


Assuntos
Técnicas de Química Analítica/instrumentação , Sedimentos Geológicos/química , Membranas Artificiais , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Químicos da Água/análise , Desenho de Equipamento
12.
Environ Sci Technol ; 36(1): 85-91, 2002 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11811495

RESUMO

Permeability/performance reference compounds (PRCs) are analytically noninterfering organic compounds with moderate to high fugacity from semipermeable membrane devices (SPMDs) that are added to the lipid prior to membrane enclosure. Assuming that isotropic exchange kinetics (IEK) apply and that SPMD-water partition coefficients are known, measurement of PRC dissipation rate constants during SPMD field exposures and laboratory calibration studies permits the calculation of an exposure adjustment factor (EAF). In theory, PRC-derived EAF ratios reflect changes in SPMD sampling rates (relative to laboratory data) due to differences in exposure temperature, membrane biofouling, and flow velocity-turbulence at the membrane surface. Thus, the PRC approach should allow for more accurate estimates of target solute/vapor concentrations in an exposure medium. Undersome exposure conditions, the impact of environmental variables on SPMD sampling rates may approach an order of magnitude. The results of this study suggest that most of the effects of temperature, facial velocity-turbulence, and biofouling on the uptake rates of analytes with a wide range of hydrophobicities can be deduced from PRCs with a much narrower range of hydrophobicities. Finally, our findings indicate that the use of PRCs permits prediction of in situ SPMD sampling rates within 2-fold of directly measured values.


Assuntos
Monitoramento Ambiental/instrumentação , Poluentes Ambientais/análise , Membranas Artificiais , Calibragem , Compostos Orgânicos/análise , Permeabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA