Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Acta Radiol ; 49(10): 1129-36, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19031180

RESUMO

BACKGROUND: Magnetic resonance (MR)-guided vascular interventions are of increasing interest, and, with the use of contrast-enhanced techniques, intraarterial contrast-enhanced MR angiography (ia-ce-MRA) competes with intraarterial digital subtraction angiography (ia-DSA) for the diagnostic evaluation of the infrainguinal vessel tree. PURPOSE: To assess the diagnostic value of ia-ce-MRA and high-resolution T1-weighted (hr-T1w) imaging compared to the gold-standard ia-DSA for residual stenosis and local dissections after femoropopliteal recanalization in patients with peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: Eight patients with PAOD and short vessel occlusion of their femoropopliteal arteries underwent recanalization and balloon positioning under DSA. Patients were transferred to a short-bore MR scanner. Percutaneous transluminal angioplasty (PTA) was accomplished under MR fluoroscopy. Pre- and postinterventional ia-ce three-dimensional (3D) gradient-echo MRA with gadopentate dimeglumine was performed using the intraarterial introducer sheath. Maximum intensity projections (MIP) and multiplanar reconstructions (MPR) were calculated from the data set. High-resolution T1w images of the angioplasty region before and after dilatation were acquired. Control ia-DSA images were obtained. RESULTS: The postinterventional angioplasty results for stenosis grading were comparable in ia-MRA and ia-DSA. Only two of five local dissections in ia-DSA were visualized with the ia-ce-MRA runs including MIPs and MPRs. To clearly depict dissection, hr-T1w images were needed. CONCLUSION: Grading of stenotic lesions with ia-ce-MRA after PTA is comparable to ia-DSA. Intraarterial ce-MRA with calculated MIPs and MPRs is only partially sufficient to visualize local dissections after PTA. High-resolution T1w images are required for precise diagnosis of dissections in magnetic resonance tomography.


Assuntos
Angioplastia com Balão/métodos , Arteriopatias Oclusivas/diagnóstico , Artéria Femoral/patologia , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Artéria Poplítea/patologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/métodos , Angioplastia com Balão/efeitos adversos , Arteriopatias Oclusivas/terapia , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Constrição Patológica/terapia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Seguimentos , Gadolínio DTPA , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doenças Vasculares Periféricas/etiologia , Doenças Vasculares Periféricas/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Eur Radiol ; 18(10): 2265-73, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18431575

RESUMO

Total-body contrast-enhanced MRA (CE-MRA) provides information of the entire vascular system according to a one-stop-shop approach. Short, wide-bore scanners have not yet been used for total-body CE-MRA, probably due to their restricted field of view in the z-direction. The purpose of this feasibility study is to introduce an image protocol for total-body MRA on a short, wide-bore system. The protocol includes five to six table-moving steps and two injection runs. Two pharmacologically different contrast materials (CM) were applied in ten healthy volunteers in view of possible CM-dependent influences on the protocol outcome (Gd-Bopta, Gd-Dota). Differences consisted of significantly higher CNR with Gd-Bopta with a mean of 73.8+/-38.7 versus 69.1+/-34.3 (p=0.008), significantly better arterial visualization values with Gd-Dota with a mean of 1.26+/-0.44 versus 1.53+/-0.73 (p=0.003) and a tendency to less venous overlay with Gd-Dota, mean 1.19+/-0.44 and 1.34+/-0.72, respectively (p=0.065) (two-tailed Wilcoxon matched-pairs test). Overall 94% of the steps were valued as qualitatively excellent or good. The good results with both CM suggest a transfer to further patient evaluation.


Assuntos
Artérias/anatomia & histologia , Compostos Heterocíclicos , Angiografia por Ressonância Magnética/instrumentação , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Imagem Corporal Total/métodos , Adulto , Meios de Contraste , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Phys Med Biol ; 52(23): 7073-86, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-18029994

RESUMO

In order to maintain overall navigation accuracy established by a calibration procedure in our CT-based registration-free navigation system, the CT scanner has to repeatedly generate identical volume images of a target at the same coordinates. We tested the positioning accuracy of the prototype of an advanced workplace for image-guided surgery (AWIGS) which features an operating table capable of direct patient transfer into a CT scanner. Volume images (N = 154) of a specialized phantom were analysed for translational shifting after various table translations. Variables included added weight and phantom position on the table. The navigation system's calibration accuracy was determined (bias 2.1 mm, precision +/- 0.7 mm, N = 12). In repeated use, a bias of 3.0 mm and a precision of +/- 0.9 mm (N = 10) were maintainable. Instances of translational image shifting were related to the table-to-CT scanner docking mechanism. A distance scaling error when altering the table's height was detected. Initial prototype problems visible in our study causing systematic errors were resolved by repeated system calibrations between interventions. We conclude that the accuracy achieved is sufficient for a wide range of clinical applications in surgery and interventional radiology.


Assuntos
Imobilização/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imobilização/métodos , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração/instrumentação , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-17763093

RESUMO

Technology integration is an enabling technological prerequisite to achieve a major breakthrough in sophisticated intra-operative imaging, navigation and robotics in minimally invasive and/or emergency diagnosis and therapy. Without a high degree of integration and reliability comparable to that achieved in the aircraft industry image guidance in its different facets will not ultimately succeed. As of today technology integration in the field of image-guidance is close to nonexistent. Technology integration requires inter-departmental integration of human and financial resources and of medical processes in a dialectic way. This expanded techno-socio-economic integration has profound consequences for the administration and working conditions in hospitals. At the university hospital of Basel, Switzerland, a multimodality multifunction sterile suite was put into operation after a substantial pre-run. We report the lessons learned during our venture into the world of medical technology integration and describe new possibilities for similar integration projects in the future.


Assuntos
Tecnologia Biomédica/organização & administração , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Salas Cirúrgicas/organização & administração , Robótica/organização & administração , Integração de Sistemas , Angiografia , Tecnologia Biomédica/instrumentação , Arquitetura Hospitalar , Hospitais Universitários , Humanos , Robótica/instrumentação , Tomografia Computadorizada por Raios X
5.
Artigo em Inglês | MEDLINE | ID: mdl-17763094

RESUMO

Since the beginning of 2007 the first six robotically assisted CT-based clinical punctures were performed with a new CE-certified assistance device with CT and MRI compatibility. The cases treated include bone and soft-tissue interventions, closed reduction and percutaneous fixation of pelvic fractures, radiofrequency ablation (RFA) and drainage within a Multifunctional Image-Guided Therapy Suite (MIGTS) under interdisciplinary conditions. The device was successfully integrated within the operating room environment of the MIGTS. The results of the robotically assisted CT-based procedures are promising. Even though further experience is needed in view of team experience, decrease of intervention time and system modifications, the first clinical cases demonstrate the feasibility of the system for various application types. The support offered by the device for trajectory planning, insertion point recognition, and needle guidance is especially beneficial for complex punctures with small target volumes or off-plane trajectories.


Assuntos
Punções/métodos , Robótica/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas/organização & administração , Equipe de Assistência ao Paciente , Punções/instrumentação , Robótica/instrumentação
7.
Ultraschall Med ; 28(1): 45-51, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17304412

RESUMO

PURPOSE: Colour coded duplex sonography (DS) is widely used for the assessment of renal artery stenosis (RAS). Different criteria have been specified for the detection of significant RAS. The aim of our study was to compare routinely used DS criteria, both with intra-arterial pressure gradients and arteriographic degree of stenosis, and to validate different cut-off points of these DS criteria for the assessment of haemodynamically significant RAS. MATERIALS AND METHODS: We retrospectively analysed forty-nine patients (median age 67 years, 29 male) with RAS documented by duplex sonography, referred for renal arterial subtraction arteriography and intra-arterial pressure measurement (93 renal arteries). DS measurement of peak systolic velocity (PSV) in the main renal artery, the renal/aortal velocity ratio (RAR) and the side-to-side differences of the intrarenal resistive indices (DeltaRI) were correlated to intra-arterial pressure measurements and arteriographic degree of stenosis. Receiver operating characteristics (ROC) were used to determine the best cut-off value of DS criteria. RESULTS: 39 (41 %) renal arteries had normal findings or non significant stenosis < 50 %, 23 (25 %) had a diameter reduction between 50 % and 69 %, and 31 (33 %) > or = 70 %. The systolic pressure gradient showed good correlation with the arteriographic degree of RAS (r = 0.77, p < 0.001) and the PSV measured by duplex sonography (r = 0.67, p < 0.001). Mean systolic pressure gradient was 24 mmHg at 50 % stenosis and 23 mmHg at PSV of 200 cm/sec. A PSV of > or = 200 cm/sec provided a sensitivity of 92 % and specificity of 81 % for detecting RAS of > or = 50 %. Similar results were found for RAR > or = 2.5 with a sensitivity of 92 % and specificity of 79 %. These cut-off values have a negative predictive value of 100 % for excluding high-grade RAS of > or = 70 %. A DeltaRI of > or =0.05 has low sensitivity of 31 %, but a high specificity of 97 % for detecting RAS of > or = 50 %. CONCLUSION: DS measurements and the severity of arteriographic diameter reduction correlate well with systolic pressure gradients. Clinically expedient DS criteria for detecting RAS of > or = 50 % are a PSV of > or = 200 cm/sec or a RAR of > or =2.5. These criteria allow reliable exclusion of severe RAS of > or = 70 %.


Assuntos
Obstrução da Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Ultrassonografia Doppler Dupla/métodos , Adulto , Idoso , Angiografia , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/fisiopatologia , Sensibilidade e Especificidade , Sístole , Ultrassonografia Doppler em Cores
9.
Eur J Anaesthesiol ; 22(10): 754-61, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16211733

RESUMO

BACKGROUND AND OBJECTIVE: Staff attitude plays a pivotal role in quality management. The objective of the present study was to further define how interdisciplinary emergency hospital staff experience their daily work and the extent to which the professional speciality and training of an individual influences his/her assessment of multiple-trauma team performance. METHODS: The clinical staff involved in multiple-trauma emergency management of a university hospital was asked to answer a confidential questionnaire. Factorial analysis was used to identify 8 major dimensions from a total of 53 items. RESULTS: The questionnaire was returned by 128 team members. All professional groups were most dissatisfied with the dimensions 'education and training', 'work sequence between specialities' and 'communication between specialities'. Assessment of the quality of in-hospital emergency-trauma management differed significantly between professional specialities (ANOVA, F=5.2; P=0.028); surgeons gave the highest ratings for all but one dimension. Having taken an Advanced Trauma Life Support (ATLS) course influenced significantly the total rating of multiple-trauma treatments of anaesthetists and surgeons (F=5.5; P=0.024). CONCLUSIONS: The perceptions of interdisciplinary trauma team members without the completion of an ATLS training course were that they did not communicate enough with each other and that there were differences between their expectations and reality. The differences and the communication deficits were overcome in team members who had passed an ATLS course.


Assuntos
Traumatismo Múltiplo/terapia , Equipe de Assistência ao Paciente/normas , Anestesia , Comunicação , Serviços Médicos de Emergência , Análise Fatorial , Cirurgia Geral , Hospitais Universitários , Humanos , Satisfação no Emprego , Cuidados para Prolongar a Vida , Inquéritos e Questionários , Recursos Humanos
10.
Cardiovasc Intervent Radiol ; 28(5): 649-52, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16010512

RESUMO

A 76-year-old patient suffering from two painful osteolytic metastases in C1 and C4 underwent percutaneous vertebroplasty by a hybrid technique in a multi-functional image-guided therapy suite (MIGTS). Two trocars were first placed into the respective bodies of C1 and C4 under fluoroscopic computed tomography guidance using a lateral approach. Thereafter, the patient was transferred on a moving table to the digital subtraction angiography unit in the same room for implant injection. Good pain relief was achieved by this minimally invasive procedure without complications. A hybrid approach for vertebroplasty in a MIGTS appears to be safe and feasible and might be indicated in selected cases for difficult accessible lesions.


Assuntos
Vértebras Cervicais/cirurgia , Fluoroscopia , Procedimentos Ortopédicos/métodos , Tomografia Computadorizada por Raios X , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Adenocarcinoma/cirurgia , Idoso , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Neoplasias Primárias Desconhecidas/patologia , Neoplasias Primárias Desconhecidas/cirurgia , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Dor/diagnóstico por imagem , Dor/etiologia , Dor/cirurgia , Interpretação de Imagem Radiográfica Assistida por Computador , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/cirurgia
11.
Chirurg ; 76(10): 959-66, 2005 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-16021393

RESUMO

INTRODUCTION: The purpose of this study was to examine whether staff questionnaire evaluation is useful for quality control in the emergency room (ER) setting. METHODS: Consecutive anonymous questionnaires (Likert scale 1-5) were filled out by the involved medical staff in all ER trauma cases in a university hospital from July 2002 to December 2003 (analysis of variance, P<0.05). RESULTS: In 171 ER cases, 844 staff members responded. Main criticisms concerned time management or satisfaction with personal ER training (Likert <4). Consultants rated the quality of their training significantly higher than younger doctors, two thirds of consultants vs one third of residents having passed an Advanced Trauma and Life Support course (P<0.001). Depending on responders' professional specialties and whether the situation concerned multiple trauma (Injury Severity Score >15), a significant systematic difference resulted. CONCLUSION: Our standardized staff questionnaire evaluation was revealed to be a discriminative instrument for quality management of trauma cases in the ER. To confirm these findings, correlation with clinical outcome data and further validation of the method are needed.


Assuntos
Atitude do Pessoal de Saúde , Serviço Hospitalar de Emergência/normas , Corpo Clínico Hospitalar , Traumatismo Múltiplo/cirurgia , Controle de Qualidade , Gestão da Qualidade Total , Interpretação Estatística de Dados , Feminino , Alemanha , Humanos , Satisfação no Emprego , Masculino , Medicina , Garantia da Qualidade dos Cuidados de Saúde , Especialização , Inquéritos e Questionários , Recursos Humanos
12.
Acta Radiol ; 45(6): 618-21, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15587418

RESUMO

The purpose of this study is to demonstrate the feasibility of computer-tomography-navigated closed reduction and percutaneous fixation (CRPF) in a patient with an externally rotated left acetabular fracture. After a follow-up of 18 months the patient was pain-free and had a normal range of motion in both hip joints. Radiologically, the fracture was fully consolidated, remodelled, and there were no signs of osteoarthritis. To our knowledge, CT-navigated CRPF of a rotated acetabular fracture has not been reported before. Further studies regarding the feasibility of the method are warranted.


Assuntos
Acetábulo/lesões , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X , Adulto , Estudos de Viabilidade , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Fatores de Tempo
13.
Cardiovasc Intervent Radiol ; 26(5): 502-5, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14753316

RESUMO

Delayed or non-union of a sacral fracture is a serious clinical condition that may include chronic pain, sitting discomfort, gait disturbances, neurological problems, and inability to work. It is also a difficult reconstruction problem. Late correction of the deformity is technically more demanding than the primary treatment of acute pelvic injuries. Open reduction, internal fixation (ORIF), excision of scar tissue, and bone grafting often in a multi-step approach are considered to be the treatment of choice in delayed unions of the pelvic ring. This procedure implies the risk of neurological and vascular injuries, infection, repeated failure of union, incomplete correction of the deformity, and incomplete pain relief as the most important complications. We report a new approach for minimally invasive treatment of a delayed union of the sacrum without vertical displacement. A patient who suffered a Malgaigne fracture (Tile C1.3) was initially treated with closed reduction and percutaneous screw fixation (CRPF) of the posterior pelvic ring under CT navigation and plating of the anterior pelvic ring. Three months after surgery he presented with increasing hip pain caused by a delayed union of the sacral fracture. The lesion was successfully treated percutaneously in a single step procedure using CT navigation for drilling of the delayed union, autologous bone grafting, and screw fixation.


Assuntos
Fraturas não Consolidadas/cirurgia , Sacro/lesões , Sacro/cirurgia , Parafusos Ósseos , Transplante Ósseo/métodos , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Sacro/diagnóstico por imagem , Transplante Autólogo
14.
AJR Am J Roentgenol ; 177(6): 1371-5, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11717086

RESUMO

OBJECTIVE: The purpose of our study was to assess the value of a modified three-point Dixon MR technique for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet, correlated with arthroscopy. SUBJECTS AND METHODS: Twenty consecutive patients who underwent both MR imaging and arthroscopy of the knee joint for suspected internal derangement were examined. A modified three-point Dixon MR sequence with a single radiofrequency echo single-scan method for water and fat separation with correction of the static field inhomogeneities was performed on a 0.35-T open magnet to obtain fat suppression. The MR images were prospectively evaluated for the presence and grade of articular cartilage defects. RESULTS: Uniform fat suppression was obtained in all patients using the modified three-point Dixon technique. Fifty-nine cartilage abnormalities were identified in 19 patients on the basis of arthroscopy. Forty-seven of 59 arthroscopically proven abnormalities were prospectively detected on MR imaging. Compared with arthroscopy, the overall sensitivity of the modified three-point Dixon technique in detecting cartilage lesions was 80% and the specificity was 73%. Sixty-five percent of the cartilage abnormalities were graded identically on MR imaging and arthroscopy. CONCLUSION: The modified three-point Dixon sequence is a useful technique for achieving fat suppression in the knee joint on a 0.35-T open magnet. It is a sensitive and specific technique for the assessment of cartilage abnormalities in the knee.


Assuntos
Doenças das Cartilagens/patologia , Cartilagem Articular/patologia , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Campos Eletromagnéticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA