1.
PLoS One ; 19(5): e0301845, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38787860

RESUMO

Differential white blood cell counts are frequently used in diagnosis, patient stratification, and treatment selection to optimize therapy responses. Referral laboratories are often used but challenged with use of different hematology platforms, variable blood shipping times and storage conditions, and the different sensitivities of specific cell types. To extend the scientific literature and knowledge on the temporal commutability of blood samples between hematology analyzers, we performed a comparative ex-vivo study using four of the most utilized commercial platforms, focusing on the assessment of eosinophils given its importance in asthma management. Whole blood from healthy volunteers with and without atopy (n = 6+6) and participants with eosinophilic asthma (n = 6) were stored under different conditions (at 4, 20, 30, and 37°C, with or without agitation) and analyzed at different time points (3, 6, 24, 48 and 72h post-sampling) in parallel on the Abbott CELL-DYN Sapphire, Beckman Coulter DxH900, Siemens ADVIA 2120i and Sysmex XN-1000V. In the same blood samples, eosinophil-derived neurotoxin (EDN), eosinophil activation and death markers were analyzed. All platforms gave comparable measurements of cell differentials on fresh blood within the same day of sampling. However, by 24 hours, significant temporal and temperature-dependent differences were observed, most markedly for eosinophils. None of the platforms performed perfectly across all temperatures tested during the 72 hours, showing that handling conditions should be optimized depending on the cell type of interest and the hematology analyzer. Neither disease status (healthy vs. asthma) nor agitation of the sample affected the cell quantification result or EDN release. The eosinophil activation markers measured by flow cytometry increased with time, were influenced by temperature, and were higher in those with asthma versus healthy participants. In conclusion, hematology analyzer, time window from sampling until analysis, and temperature conditions must be considered when analyzing blood cell differentials, particularly for eosinophils, via central labs to obtain counts comparable to the values obtained in freshly sampled blood.


Assuntos
Asma , Eosinófilos , Humanos , Asma/sangue , Asma/diagnóstico , Eosinófilos/citologia , Feminino , Masculino , Adulto , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/métodos , Contagem de Leucócitos/instrumentação , Contagem de Leucócitos/métodos , Pessoa de Meia-Idade , Hematologia/instrumentação , Hematologia/métodos
2.
J Immunol Methods ; 500: 113181, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34762913

RESUMO

Eosinophil-derived neurotoxin (EDN) is a surrogate biomarker of eosinophil activation and has considerable potential as a precision medicine biomarker in diseases where eosinophils may play a causative role. Clinical data for EDN have been generated using different quantitative immunoassays, but comparisons between these individual data sets are challenging as no internationally recognised EDN standards or orthogonal methods exist. In this study we aimed to compare commercial EDN assays from ALPCO, MBL, LSBio and CUSABIO for sample commutability. Firstly, we analytically validated the ALPCO enzyme linked immunosorbent assay (ELISA) and demonstrated appropriate analytical characteristics, including an intra/inter-assay precision coefficient-of-variation of between 1.9 and 6.8%. EDN purified from blood proved to be a good quality control material, whereas recombinant EDN, expressed in E.coli, did not react in the ALPCO immunoassay. Using healthy and asthma patient serum samples we confirmed that the ALPCO assay correlated well with the MBL assay, with a coefficient of determination (R2) of 0.92. However, the results from LSBio and CUSABIO assays were not commutable to the other assays.


Assuntos
Asma/diagnóstico , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Neurotoxina Derivada de Eosinófilo/sangue , Eosinófilos/imunologia , Humanos , Variações Dependentes do Observador , Controle de Qualidade , Reprodutibilidade dos Testes
3.
PLoS One ; 16(2): e0246627, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33566823

RESUMO

There is a growing body of evidence for the utility of eosinophil-derived neurotoxin (EDN) as a biomarker in asthma, including association with eosinophilic airway inflammation, assessment of disease severity and potential for predicting pathogenic risks, including exacerbations. However, to interpret any biomarker data with confidence, it is first important to understand the preanalytical factors and biological variation that may affect its reliable measurement and results interpretation. In this study we defined the healthy serum EDN reference range for men and women as 1.98 to 26.10 ng/mL, with no significant gender differences. Smoking did not impact the mean EDN levels and no circadian rhythm was identified for EDN, unlike blood eosinophils (EOS) where levels peaked at 00:00h. EDN expression in different cell types was investigated and shown to occur primarily in eosinophils, indicating they are likely to be the main cellular repository for EDN. We also confirm that the quantification of serum EDN is not influenced by the type of storage tube used, and it is stable at ambient temperature or when refrigerated for at least 7 days and for up to one year when frozen at -20°C or -80°C. In summary, EDN is a stable biomarker that may prove useful in precision medicine approaches by enabling the identification of a subpopulation of asthma patients with activated eosinophils and a more severe form of the disease.


Assuntos
Asma/imunologia , Neurotoxina Derivada de Eosinófilo/imunologia , Adulto , Idoso , Asma/sangue , Biomarcadores/sangue , Eosinófilos/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Índice de Gravidade de Doença
4.
Physiol Meas ; 39(8): 085001, 2018 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-30019689

RESUMO

OBJECTIVE: To evaluate a new portable toolkit for quantifying upper and lower extremity muscle tone in patients with upper motor neuron syndrome (UMNS). APPROACH: Cross-sectional, multi-site, observational trial to test and validate a new technology. SETTING: Neurorehabilitation clinics at tertiary care hospitals. PARTICIPANTS: Four cohorts UMNS patient, >6 mo post acquired brain injury, spinal cord injury, multiple sclerosis and cerebral palsy, and a sample of healthy age-matched adult controls. MEASURES: Strength: grip, elbow flexor and extensor, and knee extensor; range of motion (ROM): passive ROM (contracture) and passive-active ROM (paresis); objective spasticity: stretch-reflex test for elbow, and pendulum test for knee; subjective spasticity: modified Ashworth scale scores for elbow and knee flexors and extensors. RESULTS: Measures were acquired for 103 patients from three rehabilitation clinics. Results for patient cohorts were consistent with the literature. Grip strength correlated significantly with elbow muscle strength and all patient populations were significantly weaker in upper- and lower-extremity compared to controls. Strength and paresis were correlated for elbow and knee but neither correlated with contracture. Elbow spasticity correlated with strength and paresis but not contracture. Knee spasticity correlated with strength, and subjective spasticity correlated with contracture. SIGNIFICANCE: The BioTone™ toolkit provided comprehensive objective measures for assessing muscle tone in patients with UMNS. The toolkit could be useful for standardizing outcomes measures in clinical trials and for routine practice.


Assuntos
Tono Muscular , Reabilitação Neurológica/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Cotovelo/inervação , Feminino , Humanos , Joelho/inervação , Masculino , Pessoa de Meia-Idade , Neurônios Motores/patologia , Força Muscular , Padrões de Referência , Adulto Jovem
5.
Arthritis Res Ther ; 20(1): 78, 2018 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-29720236

RESUMO

BACKGROUND: The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSensplus point-of-care meter. METHODS: UA levels were measured using both the HumaSensplus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSensplus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin's concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. RESULTS: In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87-0.92), Lin's coefficient was 0.91 (0.88-0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 µmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 µmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine plasma results were discordant, comparison with LC-MS measurements showed that plasma measurements had better concordance: capillary UA, ICC 0.84 (95% CI 0.75-0.90), Lin's coefficient 0.84 (0.77-0.91); plasma UA, ICC 0.96 (0.94-0.98), Lin's coefficient 0.96 (0.94-0.98). CONCLUSIONS: UA measurements with the HumaSensplus meter were reasonably comparable with those of the laboratory assay. The meter is easy to use and may be useful in the clinic and in epidemiologic studies.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Punções/instrumentação , Ácido Úrico/sangue , Coleta de Amostras Sanguíneas/métodos , Feminino , Gota/sangue , Gota/diagnóstico , Humanos , Hiperuricemia/sangue , Hiperuricemia/diagnóstico , Masculino , Pessoa de Meia-Idade , Punções/métodos , Curva ROC , Reprodutibilidade dos Testes
6.
J Immunol Methods ; 449: 76-79, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28713008

RESUMO

Myeloperoxidase (MPO) is predominantly expressed by neutrophils and is an important enzyme used by the immune system for the neutralisation of bacteria and other microorganisms. The strong oxidative activity of MPO has been linked to pro-inflammatory responses in surrounding cells and tissues with implication in the pathophysiology of cardiovascular, neuroscience and inflammatory diseases. This broad disease association has made MPO an attractive biomarker and therapeutic target. Here we describe the construction and validation of a single combined MPO activity and protein concentration assay using commercially available reagents. This method offers the investigative laboratory the ability to generate results from blood plasma samples in a single analytical run using the same sample aliquot.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/análise , Ensaio de Imunoadsorção Enzimática/métodos , Peroxidase/sangue , Humanos , Peroxidase/metabolismo
7.
J Clin Pharmacol ; 57(11): 1460-1471, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28618005

RESUMO

Lanabecestat (AZD3293; LY3314814) is an orally active potent inhibitor of human ß-secretase 1 in clinical development for the treatment of Alzheimer disease. In this first Japanese clinical study for an Alzheimer disease intervention to include cerebrospinal fluid (CSF) sampling in Japanese elderly healthy subjects, we report the pharmacokinetics and effects on plasma and CSF amyloid-ß (Aß) peptides of lanabecestat in a phase 1 study involving 40 healthy Japanese subjects (NCT02005211). No safety and tolerability concerns were identified in healthy Japanese subjects exposed to lanabecestat up to the highest doses given, which is consistent with observations in a US phase 1 study of lanabecestat. Exposure to lanabecestat was similar for young and elderly subjects and increased in a dose-dependent manner. For elderly subjects, plasma lanabecestat half-life after multiple dosing was 12 to 17 hours (on days 10 and 14). Robust plasma and CSF Aß peptide reductions were also seen at all doses, with CSF Aß42 concentrations reduced by 63% and 79% in the 15- and 50-mg lanabecestat groups, respectively. CSF soluble amyloid-ß precursor protein ß also decreased following lanabecestat treatment. Suppression of CSF Aß peptides was similar in elderly healthy Japanese subjects and US patients with mild to moderate Alzheimer disease. Lanabecestat is a promising potentially disease-modifying treatment in phase 3 development for patients with early Alzheimer disease.


Assuntos
Secretases da Proteína Precursora do Amiloide/antagonistas & inibidores , Peptídeos beta-Amiloides/metabolismo , Ácido Aspártico Endopeptidases/antagonistas & inibidores , Líquido Cefalorraquidiano/metabolismo , Imidazóis/uso terapêutico , Plasma/metabolismo , Compostos de Espiro/uso terapêutico , Adulto , Idoso , Doença de Alzheimer/tratamento farmacológico , Secretases da Proteína Precursora do Amiloide/metabolismo , Precursor de Proteína beta-Amiloide/metabolismo , Povo Asiático , Encéfalo/metabolismo , Método Duplo-Cego , Feminino , Meia-Vida , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/metabolismo , Adulto Jovem
8.
PLoS One ; 11(9): e0162076, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27598247

RESUMO

Ulcerative colitis is a chronic inflammatory disease affecting the colon and is characterized by epithelial damage and barrier dysfunction. Upregulation of the tight junction protein claudin-2 by cytokines is hypothesized to contribute to the dysregulation of the epithelial barrier. New therapeutic agents which block the action of cytokines are being investigated in patients with ulcerative colitis. In order to understand the potential of these therapies, it is important to have reliable assays that can assess downstream endpoints that reflect drug mechanism of action. The aim of the current study was therefore to establish & validate an assay to reproducibly assess the expression and distribution of claudin-2 in human colon biopsy samples. Initially, the potential to measure claudin-2 protein by immunohistochemistry (IHC) was investigated. To identify suitable reagents to develop an IHC assay, pre-established criteria were used to screen five commercial antibodies by Western blotting, immunofluorescence and immunohistochemistry on claudin-2 positive and negative cells and healthy and ulcerative colitis colon tissue. Despite some of these antibodies specifically detecting claudin-2 using some of these techniques, none of the antibodies showed the expected specific staining pattern in formalin fixed human colon samples. As an alternative method to detect claudin-2 expression and distribution in formalin fixed biopsy sections, an in situ hybridization assay was developed. This assay underwent a novel tiered approach of validation to establish that it was fit-for-purpose, and suitable for clinical deployment. In addition, to understand the possible relationship of claudin-2 in the context of disease severity, expression was compared to the Geboes score. Overall, the microscopical Geboes score correlated with the claudin-2 biomarker score for samples that retained crypt morphology; samples with the highest Geboes score were not specifically distinguished, probably due to crypt destruction. In summary, we have applied a strategy for identifying target-specific antibodies in formalin fixed biopsy samples and highlighted that (published) antibodies may not correctly identify the intended antigen in tissues fixed using this method. Furthermore, we have developed and, for the first time, validated an in situ hybridization assay for detection of claudin-2 mRNA, suitable for use as a supportative method in clinical trials. Using our validated assay, we have demonstrated that increased claudin-2 expression correlates with the severity of ulcerative colitis, where crypt destruction is not seen.


Assuntos
Claudina-2/genética , Colite Ulcerativa/diagnóstico , Colo/metabolismo , Hibridização In Situ/normas , Mucosa Intestinal/metabolismo , Animais , Anticorpos/química , Biomarcadores/metabolismo , Biópsia , Western Blotting , Células CHO , Colite Ulcerativa/metabolismo , Colite Ulcerativa/patologia , Colo/patologia , Cricetulus , Formaldeído , Expressão Gênica , Humanos , Imuno-Histoquímica , Mucosa Intestinal/patologia , Índice de Gravidade de Doença , Fixação de Tecidos/métodos
9.
Expert Rev Mol Diagn ; 16(3): 373-82, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26689648

RESUMO

OBJECTIVE: A key goal in gout treatment is achieving sustained serum uric acid (sUA) lowering. Point-of-care test (PoCT) meters provide convenient, rapid measures of sUA levels to monitor/adjust therapy. Four commercially available sUA PoCT meters were compared qualitatively (ease of use) and quantitatively (precision/accuracy). METHODS: Liquid chromatography mass spectrometry (LC-MS) analysis was used as a laboratory reference method to compare precision of PoCT devices using blood samples from 20 healthy volunteers. Accuracy was compared against the LC-MS reference method and a laboratory clinical chemistry platform. RESULTS: Qualitatively, EasyTouch(®) GU and UASure were least user-friendly, requiring repeated attempts for accurate use. HumaSens and BeneCheck provided good usability and assay precision. Cross-validation of meter precision with laboratory-based uricase assay gave good correlations between both methods (R(2) = 0.8061 and 0.7605, respectively). CONCLUSION: UA PoCT meters can be important in managing gout, and the characteristics compared herein may enhance successful patient uptake.


Assuntos
Análise Química do Sangue/instrumentação , Equipamentos para Diagnóstico/normas , Sistemas Automatizados de Assistência Junto ao Leito , Ácido Úrico/sangue , Adulto , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
10.
Virchows Arch ; 462(3): 269-79, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23354597

RESUMO

BRCA1 protein measurement has previously been evaluated as a potential diagnostic marker without reaching a conclusive recommendation. In this study, we applied current best practice in antibody validation to further characterize MS110, a widely used antibody targeting BRCA1. Antibody specificity was investigated using different biochemical validation techniques. We found that BRCA1 could not be reliably detected using immunoprecipitation and Western blot in endogenously expressing cells. We used immunohistochemistry on formalin-fixed paraffin-embedded cell pellets to establish compatibility with formalin-fixed paraffin-embedded samples. We demonstrated that in transfected cells and cell lines with known genetic BRCA1 status, MS110 successfully detected BRCA1 giving the expected level of staining in immunohistochemistry. Following this, we investigated the use of BRCA1 protein measurement by immunohistochemistry in a cohort of triple negative breast and serous ovarian tumour samples to explore the use of BRCA1 protein measurement by immunohistochemistry for patient stratification. Using MS110 in repeated standardized experiments, on serial sections from a panel of patient samples, results demonstrated considerable run-to-run variability. We concluded that in formalin-fixed tissue samples, MS110 does detect BRCA1; however, using standard methodologies, BRCA1 expression levels in tissue samples is incompatible with the use of this protein as a statistically robust patient selection marker in immunohistochemistry. These results demonstrate the need for further development to deliver BRCA1 protein quantification by immunohistochemistry as a patient stratification marker.


Assuntos
Anticorpos Monoclonais , Proteína BRCA1/análise , Biomarcadores Tumorais/análise , Neoplasias da Mama/metabolismo , Neoplasias Ovarianas/metabolismo , Proteína BRCA1/genética , Biomarcadores Tumorais/genética , Western Blotting , Neoplasias da Mama/genética , Feminino , Imunofluorescência , Humanos , Imuno-Histoquímica , Imunoprecipitação , Neoplasias Ovarianas/genética , Transcriptoma , Transfecção