RESUMO
In this multicenter, prospective, observational study, abdominal aortic flow was examined with pulsed-wave Doppler ultrasound in dogs with a left-to-right shunting patent ductus arteriosus (PDA) and in apparently healthy dogs. Forty-eight dogs with a PDA and 35 controls were included. In the dogs with a PDA, 37/48 had hemodynamically significant PDAs (hsPDAs) while 11/48 had non-hsPDAs, based on the presence or absence of echocardiographic signs of left-sided volume overload, respectively. In 12 dogs (4/35 control dogs, 7/37 dogs with an hsPDA and 1/11 dogs with a non-hsPDA), the diastole was too short to visualize the end-diastolic flow. Antegrade end-diastolic flow was observed in 30/35 controls and 6/11 dogs with a non-hsPDA. Absent end-diastolic flow was observed in 1/35 control dogs and 3/11 dogs with a non-hsPDA. Retrograde end-diastolic flow was observed in 30/37 dogs with an hsPDA and 1/11 dogs with a non-hsPDA. Twenty-one dogs (15 with an hsPDA and 6 with a non-hsPDA) were reassessed after PDA closure, and, in 19/21, end-diastolic flow was visualized: 17/19 showed an antegrade flow, 1/19 an absent flow and 1/19 a retrograde flow. Sensitivity and specificity of retrograde end-diastolic flow for detection of hsPDAs were 100% and 90%, respectively. In conclusion, ultrasonographic assessment of abdominal aortic flow was feasible in dogs with PDA. However, end-diastolic flow was not always visualized. The presence of a retrograde end-diastolic flow was an accurate finding for discriminating hsPDAs and non-hsPDAs.
RESUMO
BACKGROUND: Minimally invasive transcatheter occlusion using Amplatz canine duct occluder (ACDO) is the treatment of choice for dogs with left-to-right shunting patent ductus arteriosus (PDA). However, in small dogs the femoral artery diameter is often too small to accommodate the guiding catheter required for ACDO deployment. OBJECTIVE: Describe the effectiveness of transarterial implantation of Amplatzer Vascular Plug 4 (AVP-4), the only self-expandable nitinol mesh occlusion device which can be implanted through a 4 French diagnostic catheter, in small dogs with left-to-right shunting PDA. ANIMALS: Seven client-owned dogs. METHODS: Descriptive case series. Dogs with hemodynamically relevant left-to-right shunting PDA and a femoral artery diameter less than 2.0 mm measured preoperatively with ultrasonography were prospectively enrolled. RESULTS: Angiography after releasing the device showed complete immediate PDA closure in 5 dogs, where the manufacturers' recommendation were strictly followed (30%-50% device oversizing of the ductal ampulla's diameter). Trivial residual flow on angiography in the 6th dog, whose device was slightly undersized, had resolved on echocardiography within 2 hours after placement. Marked device undersizing in the 7th dog resulted in severe residual shunting, which necessitated the addition of a coil. In this dog, the AVP-4 embolized into the pulmonary artery within 2 weeks after placement. CONCLUSIONS AND CLINICAL IMPORTANCE: Transarterial implantation of AVP-4 is a safe, effective and technically easy procedure for PDA occlusion in small dogs and offers a valuable alternative to coil implantation. Accurate PDA measurement and device sizing is essential to prevent residual shunting, inadvertent device embolization, and protrusion of the device into the aorta.