Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 14012, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35977946

RESUMO

The purpose of this study was to compare swing time and golf club angle parameters during golf swings using three, two dimensional (2D) low cost, Augmented-Video-based-Portable-Systems (AVPS) (Kinovea, SiliconCoach Pro, SiliconCoach Live). Twelve right-handed golfers performed three golf swings whilst being recorded by a high-speed 2D video camera. Footage was then analysed using AVPS-software and the results compared using both descriptive and inferential statistics. There were no significant differences for swing time and the golf phase measurements between the 2D and 3D software comparisons. In general, the results showed a high Intra class Correlation Coefficient (ICC > 0.929) and Cronbach's Coefficient Alpha (CCA > 0.924) reliability for both the kinematic and temporal parameters. The inter-rater reliability test for the swing time and kinematic golf phase measurements on average were strong. Irrespective of the AVPS software investigated, the cost effective AVPS can produce reliable output measures that benefit golf analyses.


Assuntos
Golfe , Fenômenos Biomecânicos , Movimento , Reprodutibilidade dos Testes , Software , Gravação de Videoteipe
2.
Technol Health Care ; 30(3): 713-724, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34542047

RESUMO

BACKGROUND: Electromyographic systems are widely used in scientific and clinical practice. The reproducibility and reliability of these measures are crucial when conducting scientific research and collecting experimental data. OBJECTIVE: To test the reliability of surface electromyography signals from both the Flexor Digitorum Superficialis (FDS) and Extensor Carpi Radialis Brevis (ECRB) muscles of both the left and right arms during an individual, static multi-planar maximum voluntary contraction handgrip task using the Myon 320 system (Myon AG, Switzerland). METHODS: Eight right-handed male participants performed two maximal handgrip tests in five separate wrist positions using both hands. Muscle activity was recorded from both forearms. Reliability was measured using the Standard Error of Measurement (SEM), Coefficient of Variation (CV) and Intra-class correlation coefficients. Wrist joint position correlations within and between the FDS and ECRB muscle activities were also analysed. RESULTS: Absolute reliability was shown across all positions for both hands with CV and SEM recorded at below 10%. The output measures indicate that the Myon 320 system (Myon AG, Switzerland) produces good to fair reliability when assessing forearm muscle activity. Correlations in the left FDS muscles were negative. Correlations between the left ECRB and left FDS muscles were variable but positive between the right ECRB and right FDS muscles. CONCLUSIONS: The data sets retrieved from all participants were reliably evaluated. Wrist position correlations within and between the FDS and ECRB muscles may have been influenced by hand dominance. The findings demonstrate that the methods and systems outlined in this study can be used reliably in future research.


Assuntos
Antebraço , Força da Mão , Eletromiografia/métodos , Antebraço/fisiologia , Força da Mão/fisiologia , Humanos , Masculino , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Projetos Piloto , Reprodutibilidade dos Testes , Punho/fisiologia , Articulação do Punho
3.
Res Sports Med ; 24(3): 222-33, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27267082

RESUMO

The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.


Assuntos
Golfe/fisiologia , Músculo Esquelético/fisiologia , Equipamentos Esportivos , Adulto , Desempenho Atlético , Eletromiografia , Desenho de Equipamento , Antebraço , Humanos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...