Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Fluids (1994) ; 35(10): 103117, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37849975

RESUMO

Viscoelastic focusing has emerged as a promising method for label-free and passive manipulation of micro and nanoscale bioparticles. However, the design of microfluidic devices for viscoelastic particle focusing requires a thorough comprehensive understanding of the flow condition and operational parameters that lead to the desired behavior of microparticles. While recent advancements have been made, viscoelastic focusing is not fully understood, particularly in straight microchannels with rectangular cross sections. In this work, we delve into inertial, elastic, and viscoelastic focusing of biological cells in rectangular cross-section microchannels. By systematically varying degrees of fluid elasticity and inertia, we investigate the underlying mechanisms behind cell focusing. Our approach involves injecting cells into devices with a fixed, non-unity aspect ratio and capturing their images from two orientations, enabling the extrapolation of cross-sectional equilibrium positions from two dimensional (2D) projections. We characterized the changes in hydrodynamic focusing behaviors of cells based on factors, such as cell size, flow rate, and fluid characteristics. These findings provide insights into the flow characteristics driving changes in equilibrium positions. Furthermore, they indicate that viscoelastic focusing can enhance the detection accuracy in flow cytometry and the sorting resolution for size-based particle sorting applications. By contributing to the advancement of understanding viscoelastic focusing in rectangular microchannels, this work provides valuable insight and design guidelines for the development of devices that harness viscoelastic focusing. The knowledge gained from this study can aid in the advancement of viscoelastic particle manipulation technique and their application in various fields.

2.
BMB Rep ; 56(12): 651-656, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37679295

RESUMO

Senescence, a cellular process through which damaged or dysfunctional cells suppress the cell cycle, contributes to aging or age-related functional decline. Cell metabolism has been closely correlated with aging processes, and it has been widely recognized that metabolic changes underlie the cellular alterations that occur with aging. Here, we report that fatty acid oxidation (FAO) serves as a critical regulator of cellular senescence and uncover the underlying mechanism by which FAO inhibition induces senescence. Pharmacological or genetic ablation of FAO results in a p53-dependent induction of cellular senescence in human fibroblasts, whereas enhancing FAO suppresses replicative senescence. We found that FAO inhibition promotes cellular senescence through acetyl-CoA, independent of energy depletion. Mechanistically, increased formation of autophagosomes following FAO inhibition leads to a reduction in SIRT1 protein levels, thereby contributing to senescence induction. Finally, we found that inhibition of autophagy or enforced expression of SIRT1 can rescue the induction of senescence as a result of FAO inhibition. Collectively, our study reveals a distinctive role for the FAO-autophagy-SIRT1 axis in the regulation of cellular senescence. [BMB Reports 2023; 56(12): 651-656].


Assuntos
Senescência Celular , Sirtuína 1 , Humanos , Sirtuína 1/genética , Sirtuína 1/metabolismo , Senescência Celular/fisiologia , Envelhecimento/metabolismo , Autofagia , Ácidos Graxos
3.
Biochem Biophys Res Commun ; 674: 124-132, 2023 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-37419033

RESUMO

Metastasis is one of the most malignant characteristics of cancer cells, in which metabolic reprogramming is crucial for promoting and sustaining multi-steps of metastasis, including invasion, migration and infiltration. Recently, it has been shown that melanoma cells undergo a metabolic switching toward the upregulation of fatty acid oxidation (FAO) during metastasis. However, the underlying mechanisms by which FAO contributes to metastasis of melanoma cells remain obscure. Here, we report that FAO contributes to melanoma cell migration and invasion by regulating the formation of autophagosomes. Pharmacological or genetic inhibition of FAO impairs migration of melanoma cells, which seems not to be linked to energy production or redox homeostasis. Importantly, we reveal that acetyl-CoA production by FAO contributes to melanoma cell migration through autophagy regulation. Mechanistically, FAO inhibition results in increased autophagosome formation, which suppresses migration and invasion properties of melanoma cells. Our results underscore the crucial role of FAO in melanoma cell migration and support the potential therapeutic relevance of modulating cellular acetyl-CoA levels to inhibit cancer metastasis.


Assuntos
Melanoma , Humanos , Acetilcoenzima A/metabolismo , Melanoma/metabolismo , Oxirredução , Movimento Celular/fisiologia , Autofagia , Ácidos Graxos/metabolismo
4.
Chem Rev ; 122(13): 11247-11286, 2022 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737882

RESUMO

Electroporation (EP) is a commonly used strategy to increase cell permeability for intracellular cargo delivery or irreversible cell membrane disruption using electric fields. In recent years, EP performance has been improved by shrinking electrodes and device structures to the microscale. Integration with microfluidics has led to the design of devices performing static EP, where cells are fixed in a defined region, or continuous EP, where cells constantly pass through the device. Each device type performs superior to conventional, macroscale EP devices while providing additional advantages in precision manipulation (static EP) and increased throughput (continuous EP). Microscale EP is gentle on cells and has enabled more sensitive assaying of cells with novel applications. In this Review, we present the physical principles of microscale EP devices and examine design trends in recent years. In addition, we discuss the use of reversible and irreversible EP in the development of therapeutics and analysis of intracellular contents, among other noteworthy applications. This Review aims to inform and encourage scientists and engineers to expand the use of efficient and versatile microscale EP technologies.


Assuntos
Eletroporação , Membrana Celular/metabolismo , Eletrodos
5.
PLoS One ; 17(3): e0264907, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35259174

RESUMO

Direct assessment of patient samples holds unprecedented potential in the treatment of cancer. Circulating tumor cells (CTCs) in liquid biopsies are a rapidly evolving source of primary cells in the clinic and are ideal candidates for functional assays to uncover real-time tumor information in real-time. However, a lack of routines allowing direct and active interrogation of CTCs directly from liquid biopsy samples represents a bottleneck for the translational use of liquid biopsies in clinical settings. To address this, we present a workflow for using a microfluidic vortex-assisted electroporation system designed for the functional assessment of CTCs purified from blood. Validation of this approach was assessed through drug response assays on wild-type (HCC827 wt) and gefitinib-resistant (HCC827 GR6) non-small cell lung cancer (NSCLC) cells. HCC827 cells trapped within microscale vortices were electroporated to sequentially deliver drug agents into the cytosol. Electroporation conditions facilitating multi-agent delivery were characterized for both cell lines using an automatic single-cell image fluorescence intensity algorithm. HCC827 GR6 cells spiked into the blood to emulate drug-resistant CTCs were able to be collected with high purity, demonstrating the ability of the device to minimize background cell impact for downstream sensitive cell assays. Using our proposed workflow, drug agent combinations to restore gefitinib sensitivity reflected the anticipated cytotoxic response. Taken together, these results represent a microfluidics multi-drug screening panel workflow that can enable functional interrogation of patient CTCs in situ, thereby accelerating the clinical standardization of liquid biopsies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Células Neoplásicas Circulantes , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Linhagem Celular Tumoral , Gefitinibe/uso terapêutico , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Microfluídica/métodos , Células Neoplásicas Circulantes/patologia , Preparações Farmacêuticas
6.
Micromachines (Basel) ; 12(6)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34063750

RESUMO

The growing demands for label-free, high throughput processing of biological, environmental, and industrial samples have instigated technical innovations for inflow particle manipulations with better resolution and purity [...].

7.
Micromachines (Basel) ; 12(3)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802356

RESUMO

Fast and accurate interrogation of complex samples containing diseased cells or pathogens is important to make informed decisions on clinical and public health issues. Inertial microfluidics has been increasingly employed for such investigations to isolate target bioparticles from liquid samples with size and/or deformability-based manipulation. This phenomenon is especially useful for the clinic, owing to its rapid, label-free nature of target enrichment that enables further downstream assays. Inertial microfluidics leverages the principle of inertial focusing, which relies on the balance of inertial and viscous forces on particles to align them into size-dependent laminar streamlines. Several distinct microfluidic channel geometries (e.g., straight, curved, spiral, contraction-expansion array) have been optimized to achieve inertial focusing for a variety of purposes, including particle purification and enrichment, solution exchange, and particle alignment for on-chip assays. In this review, we will discuss how inertial microfluidics technology has contributed to improving accuracy of various assays to provide clinically relevant information. This comprehensive review expands upon studies examining both endogenous and exogenous targets from real-world samples, highlights notable hybrid devices with dual functions, and comments on the evolving outlook of the field.

8.
FASEB J ; 33(12): 14137-14146, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31657647

RESUMO

Metformin has been shown to alter cell adhesion protein expression, which is thought to play a role in its observed antitumor properties. We found that metformin treatment down-regulated integrin ß1 concomitant with the loss of inositol polyphosphate multikinase (IPMK) in murine myocytes, adipocytes, and hepatocytes. To determine if IPMK was upstream of integrin ß1 expression, we examined IPMK-/- mouse embryonic fibroblast cells and found that integrins ß1 and ß3 gene expression was reduced by half, relative to wild-type cells, whereas focal adhesion kinase (FAK) activity and Rho/Rac/Cdc42 protein levels were increased, resulting in migration defects. Using nanonet force microscopy, we determined that cell:extracellular matrix adhesion and cell contractility forces were decreased, confirming the functional relevance of integrin and Rho protein dysregulation. Pharmacological studies showed that inhibition of both FAK1 and proline-rich tyrosine kinase 2 partially restored integrin ß1 expression, suggesting negative regulation of integrin ß1 by FAK. Together our data indicate that IPMK participates in the regulation of cell migration and provides a potential link between metformin and wound healing impairment.-Tu-Sekine, B., Padhi, A., Jin, S., Kalyan, S., Singh, K., Apperson, M., Kapania, R., Hur, S. C., Nain, A., Kim, S. F. Inositol polyphosphate multikinase is a metformin target that regulates cell migration.


Assuntos
Metformina/farmacologia , Fosfotransferases (Aceptor do Grupo Álcool)/antagonistas & inibidores , Fosfotransferases (Aceptor do Grupo Álcool)/metabolismo , Animais , Movimento Celular , Regulação para Baixo , Fibroblastos , Quinase 1 de Adesão Focal/genética , Quinase 1 de Adesão Focal/metabolismo , Regulação Enzimológica da Expressão Gênica/efeitos dos fármacos , Hipoglicemiantes/farmacologia , Integrina beta1/genética , Integrina beta1/metabolismo , Camundongos , Camundongos Knockout , Fosfotransferases (Aceptor do Grupo Álcool)/genética
10.
Methods Mol Biol ; 1634: 65-79, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28819841

RESUMO

Circulating tumor cells (CTCs) are disseminated tumor cells that reflect the tumors of origin and can provide a liquid biopsy that would potentially enable noninvasive tumor profiling, treatment monitoring, and identification of targeted treatments. Accurate and rapid purification of CTCs holds great potential to improve cancer care but the task remains technically challenging. Microfluidic isolation of CTCs within microscale vortices enables high-throughput and size-based purification of rare CTCs from bodily fluids. Collected cells are highly pure, viable, and easily accessible, allowing seamless integration with various downstream applications. Here, we describe how to fabricate the High-Throughput Vortex Chip (Vortex-HT) and to process diluted whole blood for CTC collection. Lastly, immunostaining and imaging protocols for CTC classification and corresponding CTC image galleries are reported.


Assuntos
Separação Celular/métodos , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Neoplasias/diagnóstico , Células Neoplásicas Circulantes/patologia , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/imunologia , Biomarcadores Tumorais/metabolismo , Contagem de Células , Separação Celular/instrumentação , Tamanho Celular , Dimetilpolisiloxanos/química , Fluoresceína-5-Isotiocianato/química , Imunofluorescência/métodos , Corantes Fluorescentes/química , Humanos , Imunoconjugados/química , Queratinas/genética , Queratinas/imunologia , Queratinas/metabolismo , Antígenos Comuns de Leucócito/genética , Antígenos Comuns de Leucócito/imunologia , Antígenos Comuns de Leucócito/metabolismo , Neoplasias/sangue , Neoplasias/imunologia , Neoplasias/patologia , Células Neoplásicas Circulantes/imunologia , Células Neoplásicas Circulantes/metabolismo , Nylons/química , Ficoeritrina/química , Ligação Proteica , Reologia
11.
Sci Rep ; 7: 44757, 2017 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-28317836

RESUMO

Successful developments of new therapeutic strategies often rely on the ability to deliver exogenous molecules into cytosol. We have developed a versatile on-chip vortex-assisted electroporation system, engineered to conduct sequential intracellular delivery of multiple molecules into various cell types at low voltage in a dosage-controlled manner. Micro-patterned planar electrodes permit substantial reduction in operational voltages and seamless integration with an existing microfluidic technology. Equipped with real-time process visualization functionality, the system enables on-chip optimization of electroporation parameters for cells with varying properties. Moreover, the system's dosage control and multi-molecular delivery capabilities facilitate intracellular delivery of various molecules as a single agent or in combination and its utility in biological research has been demonstrated by conducting RNA interference assays. We envision the system to be a powerful tool, aiding a wide range of applications, requiring single-cell level co-administrations of multiple molecules with controlled dosages.


Assuntos
Eletroporação/instrumentação , Microtecnologia/instrumentação , Carbocianinas/metabolismo , Linhagem Celular Tumoral , Desenho de Equipamento , Técnicas de Transferência de Genes , Proteínas de Fluorescência Verde/metabolismo , Células HEK293 , Humanos , MicroRNAs/metabolismo , Ovalbumina/metabolismo , RNA Interferente Pequeno/metabolismo
12.
Anal Chem ; 86(20): 10099-105, 2014 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-25291206

RESUMO

Combination therapy has become one of the leading approaches for treating complex diseases because it coadministers clinically proven drugs to concurrently target multiple signaling pathways of diseased cells. Identification of synergic drug combinations at their respective effective doses without unwanted accumulative side effects is the key to success for such therapy. In this work, we demonstrate the feasibility of the vortex-assisted microfluidic electroporation system for direct drug cocktail analyses where drug substances were individually delivered into cytosols in a sequential and dosage-controlled manner. Through quantitative analyses, the synergic combinational dosage ratios of the chemotherapeutic drug and the anticancer flavonoid were identified. When integrated with high-throughput label-free rare cell purification techniques, the presented system has the potential for development of personalized medicines as the system would be capable of comprehensively assessing drug combinations directly on patients' cellular samples.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/análise , Eletroporação/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Desenho de Equipamento , Humanos , Microfluídica
13.
J Vis Exp ; (90): e51702, 2014 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-25145886

RESUMO

Electroporation has received increasing attention in the past years, because it is a very powerful technique for physically introducing non-permeant exogenous molecular probes into cells. This work reports a microfluidic electroporation platform capable of performing multiple molecule delivery to mammalian cells with precise and molecular-dependent parameter control. The system's ability to isolate cells with uniform size distribution allows for less variation in electroporation efficiency per given electric field strength; hence enhanced sample viability. Moreover, its process visualization feature allows for observation of the fluorescent molecular uptake process in real-time, which permits prompt molecular delivery parameter adjustments in situ for efficiency enhancement. To show the vast capabilities of the reported platform, macromolecules with different sizes and electrical charges (e.g., Dextran with MW of 3,000 and 70,000 Da) were delivered to metastatic breast cancer cells with high delivery efficiencies (>70%) for all tested molecules. The developed platform has proven its potential for use in the expansion of research fields where on-chip electroporation techniques can be beneficial.


Assuntos
Eletroporação/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Linhagem Celular Tumoral , Eletroporação/métodos , Humanos , Técnicas Analíticas Microfluídicas/métodos
14.
Lab Chip ; 13(14): 2764-72, 2013 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-23727978

RESUMO

We developed an on-chip microscale electroporation system that enables sequential delivery of multiple molecules with precise and independent dosage controllability into pre-selected identical populations of target cells. The ability to trap cells with uniform size distribution contributed to enhanced molecular delivery efficiency and cell viability. Additionally, the system provides real-time monitoring ability of the entire delivery process, allowing timely and independent modification of cell- and molecule-specific electroporation parameters. The precisely controlled amount of inherently membrane-impermeant molecules was transferred into human cancer cells by varying electric field strengths and molecule injection durations. The proposed microfluidic electroporation system's improved viability and comparable gene transfection efficiency to that of commercial systems suggest that the current system has great potential to expand the research fields that on-chip electroporation techniques can be used in.


Assuntos
Eletroporação/instrumentação , Eletroporação/métodos , Técnicas de Transferência de Genes , Técnicas Analíticas Microfluídicas , Animais , Linhagem Celular Tumoral , Sobrevivência Celular , Eletroquimioterapia/instrumentação , Eletroquimioterapia/métodos , Desenho de Equipamento , Corantes Fluorescentes/química , Corantes Fluorescentes/metabolismo , Genes Reporter , Proteínas de Fluorescência Verde/genética , Humanos , Proteínas Luminescentes/genética , Microscopia de Fluorescência , Plasmídeos , Transfecção , Proteína Vermelha Fluorescente
15.
PLoS One ; 7(10): e46550, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23056341

RESUMO

Passive and label-free isolation of viable target cells based on intrinsic biophysical cellular properties would allow for cost savings in applications where molecular biomarkers are known as well as potentially enable the separation of cells with little-to-no known molecular biomarkers. We have demonstrated the purification of adrenal cortical progenitor cells from digestions of murine adrenal glands utilizing hydrodynamic inertial lift forces that single cells and multicellular clusters differentially experience as they flow through a microchannel. Fluorescence staining, along with gene expression measurements, confirmed that populations of cells collected in different outlets were distinct from one another. Furthermore, primary murine cells processed through the device remained highly viable and could be cultured for 10 days in vitro. The proposed target cell isolation technique can provide a practical means to collect significant quantities of viable intact cells required to translate stem cell biology to regenerative medicine in a simple label-free manner.


Assuntos
Córtex Suprarrenal/citologia , Microfluídica , Células-Tronco/citologia , Córtex Suprarrenal/metabolismo , Animais , Biomarcadores/metabolismo , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Células-Tronco/metabolismo
16.
Proc Natl Acad Sci U S A ; 109(29): 11630-5, 2012 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-22753513

RESUMO

Optical microscopy is one of the most widely used diagnostic methods in scientific, industrial, and biomedical applications. However, while useful for detailed examination of a small number (< 10,000) of microscopic entities, conventional optical microscopy is incapable of statistically relevant screening of large populations (> 100,000,000) with high precision due to its low throughput and limited digital memory size. We present an automated flow-through single-particle optical microscope that overcomes this limitation by performing sensitive blur-free image acquisition and nonstop real-time image-recording and classification of microparticles during high-speed flow. This is made possible by integrating ultrafast optical imaging technology, self-focusing microfluidic technology, optoelectronic communication technology, and information technology. To show the system's utility, we demonstrate high-throughput image-based screening of budding yeast and rare breast cancer cells in blood with an unprecedented throughput of 100,000 particles/s and a record false positive rate of one in a million.


Assuntos
Diagnóstico por Imagem/métodos , Citometria de Fluxo/métodos , Ensaios de Triagem em Larga Escala/métodos , Técnicas Analíticas Microfluídicas/métodos , Microscopia de Vídeo/métodos , Linhagem Celular Tumoral , Feminino , Humanos , Saccharomycetales
17.
Biomicrofluidics ; 5(2): 22206, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21918676

RESUMO

Cell isolation in designated regions or from heterogeneous samples is often required for many microfluidic cell-based assays. However, current techniques have either limited throughput or are incapable of viable off-chip collection. We present an innovative approach, allowing high-throughput and label-free cell isolation and enrichment from heterogeneous solution using cell size as a biomarker. The approach utilizes the irreversible migration of particles into microscale vortices, developed in parallel expansion-contraction trapping reservoirs, as the cell isolation mechanism. We empirically determined the critical particle∕cell diameter D(crt) and the operational flow rate above which trapping of cells∕particles in microvortices is initiated. Using this approach we successfully separated larger cancer cells spiked in blood from the smaller blood cells with processing rates as high as 7.5×10(6) cells∕s. Viable long-term culture was established using cells collected off-chip, suggesting that the proposed technique would be useful for clinical and research applications in which in vitro culture is often desired. The presented technology improves on current technology by enriching cells based on size without clogging mechanical filters, employing only a simple single-layered microfluidic device and processing cell solutions at the ml∕min scale.

18.
Lab Chip ; 11(17): 2827-34, 2011 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-21804970

RESUMO

The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.


Assuntos
Separação Celular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Automação , Linhagem Celular Tumoral , Separação Celular/métodos , Centrifugação/instrumentação , Corantes Fluorescentes/química , Humanos , Técnicas Analíticas Microfluídicas/métodos , Miniaturização , Modelos Teóricos
19.
Lab Chip ; 11(5): 912-20, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21271000

RESUMO

The ability to detect and isolate rare target cells from heterogeneous samples is in high demand in cell biology research, immunology, tissue engineering and medicine. Techniques allowing label-free cell enrichment or detection are especially important to reduce the complexity and costs towards clinical applications. Single-cell deformability has recently been recognized as a unique label-free biomarker for cell phenotype with implications for assessment of cancer invasiveness. Using a unique combination of fluid dynamic effects in a microfluidic system, we demonstrate high-throughput continuous label-free cell classification and enrichment based on cell size and deformability. The system takes advantage of a balance between deformability-induced and inertial lift forces as cells travel in a microchannel flow. Particles and droplets with varied elasticity and viscosity were found to have separate lateral dynamic equilibrium positions due to this balance of forces. We applied this system to successfully classify various cell types using cell size and deformability as distinguishing markers. Furthermore, using differences in dynamic equilibrium positions, we adapted the system to conduct passive, label-free and continuous cell enrichment based on these markers, enabling off-chip sample collection without significant gene expression changes. The presented method has practical potential for high-throughput deformability measurements and cost-effective cell separation to obtain viable target cells of interest in cancer research, immunology, and regenerative medicine.


Assuntos
Separação Celular/instrumentação , Fenômenos Mecânicos , Técnicas Analíticas Microfluídicas/métodos , Fenômenos Biomecânicos , Linhagem Celular Tumoral , Sobrevivência Celular , Elasticidade , Perfilação da Expressão Gênica , Humanos , Células Neoplásicas Circulantes/metabolismo , Viscosidade
20.
Anal Bioanal Chem ; 397(8): 3249-67, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20419490

RESUMO

Cell separation and sorting are essential steps in cell biology research and in many diagnostic and therapeutic methods. Recently, there has been interest in methods which avoid the use of biochemical labels; numerous intrinsic biomarkers have been explored to identify cells including size, electrical polarizability, and hydrodynamic properties. This review highlights microfluidic techniques used for label-free discrimination and fractionation of cell populations. Microfluidic systems have been adopted to precisely handle single cells and interface with other tools for biochemical analysis. We analyzed many of these techniques, detailing their mode of separation, while concentrating on recent developments and evaluating their prospects for application. Furthermore, this was done from a perspective where inertial effects are considered important and general performance metrics were proposed which would ease comparison of reported technologies. Lastly, we assess the current state of these technologies and suggest directions which may make them more accessible.


Assuntos
Separação Celular/métodos , Células/citologia , Técnicas Analíticas Microfluídicas/métodos , Animais , Separação Celular/instrumentação , Células/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...