1.
Childs Nerv Syst ; 39(11): 3163-3168, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36997725

RESUMO

OBJECTIVE: Conventional pediatric spine MRI protocols have multiple sequences resulting in long acquisition times. Sedation is consequently required. This study evaluates the diagnostic capability of a limited MRI spine protocol for selected common pediatric indications. METHODS: Spine MRIs at CHEO between 2017 and 2020 were reviewed across pediatric patients younger than four years old. Two blinded neuroradiologists reviewed limited scan sequences, and results were independently compared to previously reported findings from the complete imaging series. T2 sagittal sequences from the craniocervical junction to sacrum and T1 axial sequence of the lumbar spine constitute the short protocol, with the outcomes of interest being cerebellar ectopia, syrinx, level of conus, filum < 2 mm, fatty filum, and spinal dysraphism. RESULTS: A total of 105 studies were evaluated in 54 male and 51 female patients (mean age 19.2 months). The average combined scan time of the limited sequences was 15 min compared to 35 min for conventional protocols (delta = 20 min). The average percent agreement between full and limited sequences was > 95% in all but identifying a filum < 2 mm, where the percent agreement was 87%. Using limited MR sequences had high sensitivity (> 0.91) and specificity (> 0.99) for the detection of cerebellar ectopia, syrinx, fatty filum, and spinal dysraphism. CONCLUSION: This study demonstrates that selected spinal imaging sequences allow for consistent and accurate diagnosis of specific clinical conditions. A limited spine imaging protocol has potential as a screening test to reduce the need for full-sequence MRI scans. Further work is needed to determine utility of selected imaging for other clinical indications.


Assuntos
Defeitos do Tubo Neural , Disrafismo Espinal , Siringomielia , Humanos , Masculino , Feminino , Criança , Lactente , Pré-Escolar , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Vértebras Lombares , Região Lombossacral
2.
AJNR Am J Neuroradiol ; 38(8): 1636-1642, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28619840

RESUMO

BACKGROUND AND PURPOSE: Stronger magnetic fields have the potential to improve fetal image resolution. Our objective was to detect whether there was better anatomic resolution of brain structures in fetuses imaged with a 3T magnet compared with a 1.5T magnet. MATERIALS AND METHODS: Multiple cerebral and facial anatomic structures were retrospectively assessed in 28 fetal MR imaging scans with normal findings (12 at 3T and 16 at 1.5T) with a 0-3 grading score. Fetuses were assessed during the second trimesters (gestational age, 20-24 weeks). The association between the quality ratings and magnetic field strengths (1.5T versus 3T) was evaluated by a linear mixed-effects model. A quantitative assessment of the signal intensity was also performed in the different layers of the developing brain. Comparative log-ratios were calculated across the different layers of the fetal brain. RESULTS: There was a statistically significant interaction between location and magnetic field strength (P < .001). The cerebral structures of the cerebellum, pons, venous system, semicircular canal, and cochlea showed statistically significant higher values on the 3T magnet. Similarly, statistical significance was also obtained on the quantitative assessment of the multilayer appearance of the brain; the 3T magnet had a median factor of 8.38 higher than the 1.5T magnet (95% CI, 4.73-14.82). Other anatomic structures assessed in the supratentorial compartment of the brain showed higher values on the 3T magnet with no statistical significance. CONCLUSIONS: Both magnets depict cerebral and facial normal anatomic structures; however, our data indicates better anatomic detail on the 3T than on the 1.5T magnet.


Assuntos
Encéfalo/diagnóstico por imagem , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/embriologia , Campos Eletromagnéticos , Face/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Gravidez , Valores de Referência , Estudos Retrospectivos