Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Ultrasound J ; 16(1): 23, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538806

RESUMO

BACKGROUND: The use of ultrasound assessment, including the Venous Excess Ultrasound (VEXUS) score, is increasingly being utilised as part of fluid status assessment in clinical practice. We aimed to evaluate the ability of the VEXUS score to track fluid removal during the course of the dialysis session and explore the relationship between traditional measures of fluid status and venous congestion. METHODS: Single-centre, observational study in patients undergoing intermittent haemodialysis, who presented above their target dry weight. Patients had serial assessment using VEXUS, lung ultrasound and selected echocardiographic measures, before, during and after fluid removal. RESULTS: Amongst 33 patients analysed, 5 (15%) had an elevated VEXUS score (> 0). There was no difference in starting weight, dry weight or amount of fluid removed in patients with a normal VEXUS score and those with an elevated VEXUS score. In all patients with elevated VEXUS scores, the degree of venous congestion improved during the course of fluid removal. All patients with an elevated VEXUS score had evidence of both right and left ventricular systolic impairment. CONCLUSION: In patients with ESRF undergoing haemodialysis, the incidence of venous congestion as measured by the VEXUS is low. In patients with elevated VEXUS scores, removal of fluid through haemodialysis improves the venous congestion score. The pattern of LV and RV systolic dysfunction suggests that VEXUS may be a reflection of cardiac failure rather than venous volume status. TRIAL REGISTRATION: Ethical approval was provided by South Central-Berkshire Research and Ethics Committee and registered on clinicaltrials.org (IRAS305720). TRIAL REGISTRATION: ISRCTN14351189 - Retrospectively registered on 30/11/2023.

2.
Crit Care ; 26(1): 261, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050737

RESUMO

BACKGROUND: Reduced renal perfusion has been implicated in the development of septic AKI. However, the relative contributions of macro- and microcirculatory blood flow and the extent to which impaired perfusion is an intrinsic renal phenomenon or part of a wider systemic shock state remains unclear. METHODS: Single-centre prospective longitudinal observational study was carried out. Assessments were made at Day 0, 1, 2 and 4 after ICU admission of renal cortical perfusion in 50 patients with septic shock and ten healthy volunteers using contrast-enhanced ultrasound (CEUS). Contemporaneous measurements were made using transthoracic echocardiography of cardiac output. Renal artery blood flow was calculated using velocity time integral and vessel diameter. Assessment of the sublingual microcirculation was made using handheld video microscopy. Patients were classified based on the degree of AKI: severe = KDIGO 3 v non-severe = KDIGO 0-2. RESULTS: At study enrolment, patients with severe AKI (37/50) had prolonged CEUS mean transit time (mTT) (10.2 vs. 5.5 s, p < 0.05), and reduced wash-in rate (WiR) (409 vs. 1203 au, p < 0.05) and perfusion index (PI) (485 vs. 1758 au, p < 0.05); differences persisted throughout the entire study. Conversely, there were no differences in either cardiac index, renal blood flow or renal resistive index. Sublingual microcirculatory variables were not significantly different between groups at study enrolment or at any subsequent time point. Although lactate was higher in the severe AKI group at study enrolment, these differences did not persist, and there were no differences in either ScvO2 or ScvCO2-SaCO2 between groups. Patients with severe AKI received higher doses of noradrenaline (0.34 vs. 0.21mcg/kg/min, p < 0.05). Linear regression analysis showed no correlation between mTT and cardiac index (R-0.18) or microcirculatory flow index (R-0.16). CONCLUSION: Renal cortical hypoperfusion is a persistent feature in critically ill septic patients who develop AKI and does not appear to be caused by reductions in macrovascular renal blood flow or cardiac output. Cortical hypoperfusion appears not be associated with changes in the sublingual microcirculation, raising the possibility of a specific renal pathogenesis that may be amenable to therapeutic intervention. Trial Registration Clinical Trials.gov NCT03713307 , 19 Oct 2018.


Assuntos
Injúria Renal Aguda , Choque Séptico , Injúria Renal Aguda/complicações , Humanos , Microcirculação/fisiologia , Perfusão/efeitos adversos , Estudos Prospectivos , Circulação Renal , Choque Séptico/complicações
4.
PLoS One ; 16(12): e0261546, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34941918

RESUMO

INTRODUCTION: Haemorrhage is a leading cause of death following traumatic injury and the early detection of hypovolaemia is critical to effective management. However, accurate assessment of circulating blood volume is challenging when using traditional vital signs such as blood pressure. We conducted a study to compare the stroke volume (SV) recorded using two devices, trans-thoracic electrical bioimpedance (TEB) and supra-sternal Doppler (SSD), against a reference standard using trans- thoracic echocardiography (TTE). METHODS: A lower body negative pressure (LBNP) model was used to simulate hypovolaemia and in half of the study sessions lower limb tourniquets were applied as these are common in military practice and can potentially affect some haemodynamic monitoring systems. In order to provide a clinically relevant comparison we constructed an error grid alongside more traditional measures of agreement. RESULTS: 21 healthy volunteers aged 18-40 were enrolled and underwent 2 sessions of LBNP, with and without lower limb tourniquets. With respect to absolute SV values Bland Altman analysis showed significant bias in both non-tourniquet and tourniquet strands for TEB (-42.5 / -49.6 ml), rendering further analysis impossible. For SSD bias was minimal but percentage error was unacceptably high (35% / 48%). Degree of agreement for dynamic change in SV, assessed using 4 quadrant plots showed a seemingly acceptable concordance rate for both TEB (86% / 93%) and SSD (90% / 91%). However, when results were plotted on an error grid, constructed based on expert clinical opinion, a significant minority of measurement errors were identified that had potential to lead to moderate or severe patient harm. CONCLUSION: Thoracic bioimpedance and suprasternal Doppler both demonstrated measurement errors that had the potential to lead to clinical harm and caution should be applied in interpreting the results in the detection of early hypovolaemia following traumatic injury.


Assuntos
Monitorização Hemodinâmica/instrumentação , Hemorragia/fisiopatologia , Volume Sistólico , Adolescente , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
5.
BMC Nephrol ; 22(1): 359, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34719384

RESUMO

BACKGROUND: Acute kidney injury (AKI) is common among patients hospitalised with COVID-19 and associated with worse prognosis. The aim of this study was to investigate the epidemiology, risk factors and outcomes of AKI in patients with COVID-19 in a large UK tertiary centre. METHODS: We analysed data of consecutive adults admitted with a laboratory-confirmed diagnosis of COVID-19 across two sites of a hospital in London, UK, from 1st January to 13th May 2020. RESULTS: Of the 1248 inpatients included, 487 (39%) experienced AKI (51% stage 1, 13% stage 2, and 36% stage 3). The weekly AKI incidence rate gradually increased to peak at week 5 (3.12 cases/100 patient-days), before reducing to its nadir (0.83 cases/100 patient-days) at the end the study period (week 10). Among AKI survivors, 84.0% had recovered renal function to pre-admission levels before discharge and none required on-going renal replacement therapy (RRT). Pre-existing renal impairment [odds ratio (OR) 3.05, 95%CI 2.24-4,18; p <  0.0001], and inpatient diuretic use (OR 1.79, 95%CI 1.27-2.53; p <  0.005) were independently associated with a higher risk for AKI. AKI was a strong predictor of 30-day mortality with an increasing risk across AKI stages [adjusted hazard ratio (HR) 1.59 (95%CI 1.19-2.13) for stage 1; p < 0.005, 2.71(95%CI 1.82-4.05); p < 0.001for stage 2 and 2.99 (95%CI 2.17-4.11); p < 0.001for stage 3]. One third of AKI3 survivors (30.7%), had newly established renal impairment at 3 to 6 months. CONCLUSIONS: This large UK cohort demonstrated a high AKI incidence and was associated with increased mortality even at stage 1. Inpatient diuretic use was linked to a higher AKI risk. One third of survivors with AKI3 exhibited newly established renal impairment already at 3-6 months.


Assuntos
Injúria Renal Aguda , COVID-19 , Terapia de Substituição Renal , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/terapia , COVID-19/complicações , COVID-19/diagnóstico , COVID-19/epidemiologia , Estudos de Coortes , Mortalidade Hospitalar , Humanos , Incidência , Unidades de Terapia Intensiva/estatística & dados numéricos , Testes de Função Renal/métodos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Gravidade do Paciente , Terapia de Substituição Renal/métodos , Terapia de Substituição Renal/estatística & dados numéricos , Fatores de Risco , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença , Reino Unido/epidemiologia
7.
Kidney Int Rep ; 6(2): 265-271, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33521400

RESUMO

INTRODUCTION: During the coronavirus disease 2019 (COVID-19) pandemic in 2020, high rates of acute kidney injury (AKI) in critically unwell patients are being reported, leading to an increased demand for renal replacement therapy (RRT). Providing RRT for this large number of patients is proving challenging, and so alternatives to continuous renal replacement therapies (CRRT) in the intensive care unit (ICU) are needed. Peritoneal dialysis (PD) can be initiated immediately after percutaneous insertion of the catheter, but there are concerns about impact on ventilation and RRT efficacy. We sought to describe our recent experience with percutaneous catheter insertion and peritoneal dialysis in patients in the ICU with COVID-19 infection. METHOD: Patients were selected according to local protocol, and catheters were inserted percutaneously by experienced operators using a Seldinger technique. Sequential Organ Failure Assessment (SOFA) score and ventilation requirements were recorded at the time of insertion and 24 hours later. Procedural complications, proportion of RRT provided by PD, renal recovery, and RRT parameters (serum potassium and maximum base excess) during PD were assessed. RESULTS: Percutaneous PD catheters were successfully inserted in 37 of 44 patients (84.1%) after a median of 13.5 days (interquartile range [IQR] = 10.0, 20.3 days) in the ICU. No adverse events were reported; SOFA scores and ventilation requirements were comparable before and after insertion; and adequate RRT parameters were achieved. The median proportion of RRT provided by PD following catheter insertion was 94.6% (IQR = 75.0, 100%). CONCLUSION: Peritoneal dialysis provides a safe and effective alternative to CRRT in selected patients with AKI and COVID-19 infection requiring ventilation on intensive care.

8.
Nat Commun ; 12(1): 1017, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33589641

RESUMO

Nonlinear optical devices and their implementation into modern nanophotonic architectures are constrained by their usually moderate nonlinear response. Recently, epsilon-near-zero (ENZ) materials have been found to have a strong optical nonlinearity, which can be enhanced through the use of cavities or nano-structuring. Here, we study the pump dependent properties of the plasmon resonance in the ENZ region in a thin layer of indium tin oxide (ITO). Exciting this mode using the Kretschmann-Raether configuration, we study reflection switching properties of a 60 nm layer close to the resonant plasmon frequency. We demonstrate a thermal switching mechanism, which results in a shift in the plasmon resonance frequency of 20 THz for a TM pump intensity of 70 GW cm-2. For degenerate pump and probe frequencies, we highlight an additional two-beam coupling contribution, not previously isolated in ENZ nonlinear optics studies, which leads to an overall pump induced change in reflection from 1% to 45%.

9.
J Crit Care ; 62: 190-196, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33422809

RESUMO

PURPOSE: The aim of this study is to describe the incidence of Acute Kidney Injury (AKI) amongst patients admitted to the Intensive Care Unit (ICU) with COVID-19. In addition we aim to detail the range of Renal Replacement Therapy (RRT) modalities offered to these patients (including peritoneal dialysis - PD - and intermittent haemodialysis - IHD) in order to meet demand during pandemic conditions. MATERIALS AND METHODS: Single-centre retrospective case note review of adult patients with confirmed COVID-19 admitted to ICU. RESULTS: Amongst 136 patients without a prior history of End Stage Kidney Disease (ESKD), 108 (79%) developed AKI and 63% of admitted patients received RRT. Due to resource limitations the range of RRT options were expanded from solely Continuous Veno-Venous HaemoDiaFiltration (CVVHDF - our usual standard of care) to include PD (in 35 patients) and IHD (in 15 patients). During the study period the proportion of RRT provided within ICU as CVVHDF fell from 100% to a nadir of 39%. There were no significant complications of either PD or IHD. CONCLUSIONS: During periods of resource limitations PD and IHD can safely be used to reduce dependence on CVVHDF in select patients with AKI secondary to COVID-19.


Assuntos
Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia , COVID-19/complicações , Cuidados Críticos/métodos , Terapia de Substituição Renal/métodos , Adulto , Idoso , Terapia de Substituição Renal Contínua/métodos , Feminino , Humanos , Unidades de Terapia Intensiva , Terapia de Substituição Renal Intermitente/métodos , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal/estatística & dados numéricos , Estudos Retrospectivos , SARS-CoV-2 , Centros de Atenção Terciária , Reino Unido/epidemiologia
10.
Shock ; 55(4): 479-487, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32890313

RESUMO

BACKGROUND: Acute kidney injury (AKI) is a common complication of COVID-19 critical illness but the pathophysiology is uncertain. Some evidence has indicated that a vascular aetiology may be implicated. We used contrast-enhanced ultrasound (CEUS) and echocardiography to study renal perfusion and global blood flow and compared our findings with measurements taken in a group of septic shock patients and healthy volunteers. METHODS: Prospective case-control study. Renal perfusion variables were assessed with CEUS; macrovascular blood flow was assessed using Doppler analysis of large renal vessels; echocardiography was used to assess right and left heart function and cardiac output. RESULTS: CEUS-derived parameters were reduced in COVID-19 associated AKI compared with healthy controls (perfusion index 3,415 vs. 548 a.u., P = 0·001; renal blood volume 7,794 vs. 3,338 a.u., P = 0·04). Renal arterial flow quantified using time averaged peak velocity was also reduced compared with healthy controls (36·6 cm/s vs. 20·9 cm/s, P = 0.004) despite cardiac index being similar between groups (2.8 L/min/m2 vs. 3.7 L/min/m2, P = 0.07). There were no differences in CEUS-derived or cardiac parameters between COVID-19 and septic shock patients but patients with septic shock had more heterogeneous perfusion variables. CONCLUSION: Both large and small vessel blood flow is reduced in patients with COVID-19 associated AKI compared with healthy controls, which does not appear to be a consequence of right or left heart dysfunction. A reno-vascular pathogenesis of COVID-19 AKI seems likely.


Assuntos
Injúria Renal Aguda/fisiopatologia , COVID-19/complicações , COVID-19/fisiopatologia , Estado Terminal , Testes de Função Cardíaca , Circulação Renal/fisiologia , Ultrassonografia , Injúria Renal Aguda/diagnóstico por imagem , Idoso , COVID-19/diagnóstico por imagem , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fluxo Sanguíneo Regional/fisiologia , Choque Séptico/complicações , Choque Séptico/fisiopatologia
11.
Shock ; 55(6): 752-758, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33021572

RESUMO

ABSTRACT: Critically ill patients with COVID-19 infection frequently exhibit a hyperinflammatory response and develop organ failures; however, the underlying mechanisms are unclear. We investigated the microcirculatory, endothelial, and inflammatory responses in critically ill COVID-19 patients and compared them to a group of patients with septic shock in a prospective observational case control study. Thirty critically ill patients with COVID-19 were compared to 33 patients with septic shock.Measurements of sublingual microcirculatory flow using Incident Dark Field video-microscopy and serial measurements of IL-6 and Syndecan-1 levels were performed. COVID-19 patients had significantly less vasoactive drug requirement and lower plasma lactate than those with septic shock. Microcirculatory flow was significantly worse in septic patients than those with COVID-19 (MFI 2.6 vs 2.9 p 0.02, PPV 88 vs 97% P < 0.001). IL-6 was higher in patients with septic shock than COVID-19 (1653 vs 253 pg/mL, P 0.03). IL-6 levels in COVID 19 patients were not elevated compared to healthy controls except on the day of ICU admission. Syndecan-1 levels were not different between the two pathological groups. Compared to patients with undifferentiated septic shock an overt shock state with tissue hypoperfusion does not appear typical of COVID-19 infection. There was no evidence of significant sublingual microcirculatory impairment, widespread endothelial injury or marked inflammatory cytokine release in this group of critically ill COVID-19 patients.


Assuntos
COVID-19/sangue , Endotélio Vascular/metabolismo , Interleucina-6/sangue , Microcirculação , SARS-CoV-2/metabolismo , Choque Séptico/sangue , Sindecana-1/sangue , Idoso , COVID-19/patologia , Estado Terminal , Endotélio Vascular/patologia , Feminino , Humanos , Inflamação/sangue , Inflamação/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Séptico/patologia
12.
Clin Hemorheol Microcirc ; 75(2): 121-133, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929146

RESUMO

BACKGROUND: Endothelial hyperpermeability is suggested to play a role in the development of microcirculatory perfusion disturbances and organ failure following hemorrhagic shock, but evidence is limited. OBJECTIVE: To study the effect of plasma from traumatic hemorrhagic shock patients on in vitro endothelial barrier function. METHODS: Plasma from traumatic hemorrhagic shock patients was obtained at the emergency department (ED), the intensive care unit (ICU), 24 h after ICU admission and from controls (n = 8). Sublingual microcirculatory perfusion was measured using incident dark field videomicroscopy at matching time points. Using electric cell-substrate impedance sensing, the effects of plasma exposure on in vitro endothelial barrier function of human endothelial cells were assessed. RESULTS: Plasma from traumatic hemorrhagic shock patients collected at ED admission induced a 19% loss of in vitro endothelial resistance compared to plasma from controls (p < 0.001). This loss was due to reduced cell-cell contacts (p < 0.01). Plasma withdrawn at later time points did not affect endothelial barrier function (p > 0.99). Interestingly, in vitro endothelial resistance showed a positive association with in vivo microcirculatory perfusion (r = 0.56, p < 0.01). CONCLUSIONS: Plasma from traumatic hemorrhagic shock patients obtained following ED admission, but not at later stages, induced in vitro endothelial hyperpermeability. This coincided with in vivo microcirculatory perfusion disturbances.


Assuntos
Células Endoteliais/fisiologia , Adulto , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Choque Hemorrágico/fisiopatologia , Adulto Jovem
13.
Shock ; 54(1): 15-20, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31764623

RESUMO

BACKGROUND: The current standard of analyzing microcirculatory video microscopy is time-consuming and occurs away from the patient, limiting its clinical utility. Point-of-care assessment with incident dark field (IDF) microscopy, however, may offer greater clinical applicability. We aimed to determine the reproducibility of the Point of Care Microcirculation (POEM) tool when used at the bedside in critically ill patients. METHODS: A multinational, multicenter, prospective observational study of adult intubated patients was undertaken during a 9-month period in Germany, the United Kingdom, and the United States. A user recorded a batch of four standardized video clips from each patient, calculated a POEM score and recorded the time for image acquisition. A second user blinded to the first repeated this process. Patients with video clips of poor quality were excluded. At a later date, the two users again blinded themselves to reassess both their own clips and those of the other user. Basic demographic information was recorded. Intrauser reliability (an individual user rescoring the same batch of videos after blinding), interuser reliability (a second user rescoring the other user's video batch after blinding), and test-retest reliability (two users individually capturing videos and recording POEM scores) were assessed using a linearly weighted kappa statistic for ordinal data. RESULTS: Sixty-five patients were included in the final analysis. Observer agreement was substantial for all tests. Intrauser agreement was 0.73 (0.95 CI 0.64-0.81), interuser agreement 0.71 (0.95 CI 0.63-0.79), and test-retest agreement 0.75 (0.95 CI 0.65-0.86). Average time to record videos and assess POEM scores 7:34 ± 3:37 minutes. CONCLUSIONS: Point-of-care assessment of the microcirculation using IDF video microscopy and POEM scoring appears to be both a feasible and reproducible approach to microcirculatory assessment. Testing of the score in critically ill patients showed substantial agreement within and between investigators, but further studies should validate its utility as a tool to guide shock resuscitation.


Assuntos
Estado Terminal , Microcirculação , Testes Imediatos , Estado Terminal/terapia , Feminino , Humanos , Masculino , Microcirculação/fisiologia , Microscopia de Vídeo/métodos , Microscopia de Vídeo/normas , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
BMJ Open ; 9(8): e028364, 2019 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-31439601

RESUMO

INTRODUCTION: Septic acute kidney injury (AKI) is the most common complication of septic shock and increases mortality. A large body of experimental data suggests alterations in renal perfusion occur, but this is yet to be fully assessed in humans. The aim of the current study is to observe the macro and microcirculations in both the systemic and renal circulations in a cohort of patients with early septic shock. METHODS AND ANALYSIS: Single-centre, prospective, longitudinal, observational study of 50 patients with septic shock. Renal microcirculatory assessment will be performed with contrast-enhanced ultrasound, the sublingual microcirculation assessed with incident dark field microscopy and transthoracic echocardiography used to assess global flow. Patients will be enrolled as soon as possible after admission to the intensive care unit and then at +24,+48 and +96 hours. Blood samples of circulatory and renal biomarkers will be collected. Sample groups will be defined by the presence or absence of AKI and then subclassified by the severity (Kidney Disease Improving Global Outcomes (KDIGO) criteria), variables will be compared within and between groups over time. ETHICS AND DISSEMINATION: Research Ethics Committee (REC) approval has been granted for this study by Yorkshire and the Humber, Leeds West Research Ethics Committee (18/YH/0371) and due to the nature of the patients enrolled with septic shock, capacity for informed consent is likely to be lacking. Therefore, a personal consultee (friend or relative) will be consulted or a nominated consultee (clinician) in their absence. After capacity is regained, consent will then be sought from the patient in accordance with the Mental Capacity Act, UK (2005). This consent process has been approved following REC review. Results will be published in a relevant peer-reviewed journal and presented at academic meetings.


Assuntos
Injúria Renal Aguda/fisiopatologia , Rim/irrigação sanguínea , Choque Séptico/fisiopatologia , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/etiologia , Progressão da Doença , Ecocardiografia , Humanos , Rim/diagnóstico por imagem , Estudos Longitudinais , Microcirculação , Estudos Observacionais como Assunto , Estudos Prospectivos , Choque Séptico/complicações , Ultrassonografia
15.
Clin Hemorheol Microcirc ; 71(1): 71-82, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29843227

RESUMO

BACKGROUND: Preclinical studies report that higher plasma viscosity improves microcirculatory flow after haemorrhagic shock and resuscitation, but no clinical study has tested this hypothesis. OBJECTIVE: We investigated the relationship between plasma viscosity and sublingual microcirculatory flow in patients during resuscitation for traumatic haemorrhagic shock (THS). METHODS: Sublingual video-microscopy was performed for 20 trauma patients with THS as soon as feasible in hospital, and then at 24 h and 48 h. Values were obtained for total vessel density, perfused vessel density, proportion of perfused vessels, microcirculatory flow index (MFI), microcirculatory heterogeneity index (MHI), and Point of Care Microcirculation (POEM) scores. Plasma viscosity was measured using a Wells-Brookfield cone and plate micro-viscometer. Logistic regression analyses examined relationships between microcirculatory parameters and plasma viscosity, adjusting for covariates (systolic blood pressure, heart rate, haematocrit, rate and volume of fluids, and rate of noradrenaline). RESULTS: Higher plasma viscosity was not associated with improved microcirculatory parameters. Instead, there were weakly significant associations between higher plasma viscosity and lower (poorer) MFI (p = 0.040), higher (worse) MHI (p = 0.033), and lower (worse) POEM scores (p = 0.039). CONCLUSIONS: The current study did not confirm the hypothesis that higher plasma viscosity improves microcirculatory flow dynamics in patients with THS. Further clinical investigations are warranted to determine whether viscosity is a physical parameter of importance during resuscitation of these patients.


Assuntos
Microcirculação/fisiologia , Choque Hemorrágico/fisiopatologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Viscosidade
16.
Crit Care Med ; 46(9): e889-e896, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29957708

RESUMO

OBJECTIVES: To assess the relationship between microcirculatory perfusion and multiple organ dysfunction syndrome in patients following traumatic hemorrhagic shock. DESIGN: Multicenter prospective longitudinal observational study. SETTING: Three U.K. major trauma centers. PATIENTS: Fifty-eight intubated and ventilated patients with traumatic hemorrhagic shock. INTERVENTIONS: Sublingual incident dark field microscopy was performed within 12 hours of ICU admission (D0) and repeated 24 and 48 hours later. Cardiac output was assessed using oesophageal Doppler. Multiple organ dysfunction syndrome was defined as Serial Organ Failure Assessment score greater than or equal to 6 at day 7 post injury. MEASUREMENTS AND MAIN RESULTS: Data from 58 patients were analyzed. Patients had a mean age of 43 ± 19 years, Injury Severity Score of 29 ± 14, and initial lactate of 7.3 ± 6.1 mmol/L and received 6 U (interquartile range, 4-11 U) of packed RBCs during initial resuscitation. Compared with patients without multiple organ dysfunction syndrome at day 7, patients with multiple organ dysfunction syndrome had lower D0 perfused vessel density (11.2 ± 1.8 and 8.6 ± 1.8 mm/mm; p < 0.01) and microcirculatory flow index (2.8 [2.6-2.9] and 2.6 [2.2-2.8]; p < 0.01) but similar cardiac index (2.5 [± 0.6] and 2.1 [± 0.7] L/min//m; p = 0.11). Perfused vessel density demonstrated the best discrimination for predicting subsequent multiple organ dysfunction syndrome (area under curve 0.87 [0.76-0.99]) compared with highest recorded lactate (area under curve 0.69 [0.53-0.84]), cardiac index (area under curve 0.66 [0.49-0.83]) and lowest recorded systolic blood pressure (area under curve 0.54 [0.39-0.70]). CONCLUSIONS: Microcirculatory hypoperfusion immediately following traumatic hemorrhagic shock and resuscitation is associated with increased multiple organ dysfunction syndrome. Microcirculatory variables are better prognostic indicators for the development of multiple organ dysfunction syndrome than more traditional indices. Microcirculatory perfusion is a potential endpoint of resuscitation following traumatic hemorrhagic shock.


Assuntos
Insuficiência de Múltiplos Órgãos/etiologia , Choque Hemorrágico/complicações , Adulto , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Microcirculação , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/fisiopatologia , Estudos Prospectivos , Fluxo Sanguíneo Regional , Choque Hemorrágico/etiologia , Choque Hemorrágico/fisiopatologia , Ferimentos e Lesões/complicações
17.
Intensive Care Med ; 44(3): 281-299, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29411044

RESUMO

PURPOSE: Hand-held vital microscopes (HVMs) were introduced to observe sublingual microcirculatory alterations at the bedside in different shock states in critically ill patients. This consensus aims to provide clinicians with guidelines for practical use and interpretation of the sublingual microcirculation. Furthermore, it aims to promote the integration of routine application of HVM microcirculatory monitoring in conventional hemodynamic monitoring of systemic hemodynamic variables. METHODS: In accordance with the Delphi method we organized three international expert meetings to discuss the various aspects of the technology, physiology, measurements, and clinical utility of HVM sublingual microcirculatory monitoring to formulate this consensus document. A task force from the Cardiovascular Dynamics Section of the European Society of Intensive Care Medicine (with endorsement of its Executive Committee) created this consensus as an update of a previous consensus in 2007. We classified consensus statements as definitions, requirements, and/or recommendations, with a minimum requirement of 80% agreement of all participants. RESULTS: In this consensus the nature of microcirculatory alterations is described. The nature of variables, which can be extracted from analysis of microcirculatory images, is presented and the needed dataset of variables to identify microcirculatory alterations is defined. Practical aspects of sublingual HVM measurements and the nature of artifacts are described. Eleven statements were formulated that pertained to image acquisitions and quality statements. Fourteen statements addressed the analysis of the images, and 13 statements are related to future developments. CONCLUSION: This consensus describes 25 statements regarding the acquisition and interpretation of microcirculatory images needed to guide the assessment of the microcirculation in critically ill patients.


Assuntos
Estado Terminal , Microcirculação , Consenso , Cuidados Críticos , Humanos , Soalho Bucal/irrigação sanguínea
18.
J Trauma Acute Care Surg ; 84(1): 81-88, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28885470

RESUMO

BACKGROUND: Endothelial cell damage and glycocalyx shedding after trauma can increase the risk of inflammation, coagulopathy, vascular permeability, and death. Bedside sublingual video-microscopy may detect worse flow and perfusion associated with this endotheliopathy. We compared markers of endotheliopathy with physical flow dynamics after traumatic hemorrhagic shock. METHODS: Sublingual incident dark field video-microscopy was performed at three time points after injury (<10 hours, 10-30 hours, and 30-50 hours). Values for microcirculatory flow index (MFI), Point Of carE Microcirculation assessment (POEM) score, proportion of perfused vessels (PPV), microcirculatory heterogeneity index (MHI), perfused vessel density (PVD), and total vessel density (TVD) were obtained. ELISAs were performed to measure concentrations of thrombomodulin and syndecan-1 as biomarkers of endothelial cell damage and glycocalyx shedding respectively. Flow parameters were dichotomized to above and below average, and biomarkers compared between groups; below average MFI, POEM, PPV, PVD, and TVD, and above average MHI were considered poor microcirculatory flow dynamics. RESULTS: A total of 155 sublingual video-microscopy clips corresponding to 39 time points from 17 trauma patients were analyzed. Median age was 35 (IQR 25-52); 16/17 were men. Within 10 hours of injury, syndecan-1 concentrations were significantly higher compared to 17 age- and sex-matched healthy controls (30 [IQR 20-44] ng/mL) for worse TVD (78 [IQR 63-417] ng/mL), PVD (156 [IQR 63-590] ng/mL), PPV (249 [IQR 64-578] ng/mL), MFI (249 [IQR 64-578] ng/mL), MHI (45 [IQR] 38-68) ng/mL), and POEM scores (108 [IQR 44-462] ng/mL) (all p < 0.01). Thrombomodulin was also raised within 10 hours of injury when compared to healthy controls (2.9 [IQR 2.2-3.4] ng/mL) for worse PPV (4.1 [IQR 3.4-6.2] ng/mL) and MFI (4.1 [IQR 3.4-6.2] ng/mL) (both p < 0.05). CONCLUSIONS: Endothelial cell damage and glycocalyx shedding are associated with worse flow, density, and heterogeneity within microvessels after traumatic hemorrhagic shock. The clinical utility of these biomarkers and flow parameters at the bedside are yet to be elucidated. LEVEL OF EVIDENCE: Prognostic study, level III.


Assuntos
Células Endoteliais/patologia , Glicocálix/patologia , Microcirculação/fisiologia , Choque Hemorrágico/patologia , Choque Hemorrágico/fisiopatologia , Choque Traumático/patologia , Choque Traumático/fisiopatologia , Adulto , Biomarcadores/metabolismo , Células Endoteliais/metabolismo , Feminino , Humanos , Estudos Longitudinais , Masculino , Microscopia de Vídeo , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Hemorrágico/metabolismo , Choque Traumático/metabolismo , Sindecana-1/metabolismo , Trombomodulina/metabolismo
19.
PLoS One ; 12(12): e0189870, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29261771

RESUMO

BACKGROUND: Cell free deoxyribonucleic acid (cfDNA) has been proposed as a biomarker of secondary complications following trauma. Raised thrombomodulin and syndecan-1 levels have been used to indicate endotheliopathy, and are associated with inflammation, coagulopathy, and mortality. The current study aimed to analyse the association between cfDNA and biomarkers of endotheliopathy in a cohort of trauma patients, and whether raised levels of cfDNA were associated with poorer clinical outcomes. METHODS: Serum thrombomodulin and syndecan-1 were used as biomarkers of endotheliopathy and compared to plasma cfDNA in trauma patients from two prospective longitudinal observational studies. Cohort A (n = 105) had a predicted injury severity score (ISS) >8, and had blood sampled within 1h of injury and at 4-12h. Cohort B (n = 17) had evidence of haemorrhagic shock, and had blood sampled at a median time of 3.5h after injury. Relationships between biomarkers were tested using multivariable linear regression models that included the covariates of gender, age, ISS, Glasgow Coma Scale, lactate, systolic blood pressure, and heart rate. A model was fitted to investigate whether changes in cfDNA were associated with similar changes in endothelial biomarkers. RESULTS: The mean age was 41 (SD 19), and the median ISS was 25 (IQR 12-34). There was a significant association between cfDNA levels and both syndecan-1 and thrombomodulin levels (both p<0.001). This was independent of all covariates except for ISS, which significantly correlated with cfDNA levels. 50 ng/ml change in syndecan-1 and 1 ng/ml change in thrombomodulin corresponded to 15% and 20% increases in cfDNA levels respectively (both p<0.001). Patients who died had significantly higher prehospital and in-hospital cfDNA levels (both p<0.05). CONCLUSIONS: Raised cfDNA levels are associated with markers of endotheliopathy following trauma, and are associated with mortality. This relationship is present within the first hour of injury, and a change in one biomarker level is reflected by similar changes in the others. These findings are in keeping with the hypothesis that circulating DNA and endothelial injury share a common pathway following trauma.


Assuntos
Ácidos Nucleicos Livres/sangue , Endotélio Vascular/patologia , Ferimentos e Lesões/sangue , Adulto , Biomarcadores/sangue , Transtornos da Coagulação Sanguínea/sangue , Transfusão de Sangue , Feminino , Humanos , Tempo de Internação , Masculino , Estudos Prospectivos , Sindecana-1/sangue , Trombomodulina/metabolismo , Fatores de Tempo , Resultado do Tratamento
20.
BMJ Open ; 6(12): e014162, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-28003301

RESUMO

OBJECTIVES: Sublingual microcirculatory monitoring for traumatic haemorrhagic shock (THS) may predict clinical outcomes better than traditional blood pressure and cardiac output, but is not usually performed until the patient reaches the intensive care unit (ICU), missing earlier data of potential importance. This pilot study assessed for the first time the feasibility and safety of sublingual video-microscopy for THS in the emergency department (ED), and whether it yields useable data for analysis. SETTING: A safety and feasibility assessment was undertaken as part of the prospective observational MICROSHOCK study; sublingual video-microscopy was performed at the UK-led Role 3 medical facility at Camp Bastion, Afghanistan, and in the ED in 3 UK Major Trauma Centres. PARTICIPANTS: There were 15 casualties (2 military, 13 civilian) who presented with traumatic haemorrhagic shock with a median injury severity score of 26. The median age was 41; the majority (n=12) were male. The most common injury mechanism was road traffic accident. PRIMARY AND SECONDARY OUTCOME MEASURES: Safety and feasibility were the primary outcomes, as measured by lack of adverse events or clinical interruptions, and successful acquisition and storage of data. The secondary outcome was the quality of acquired video clips according to validated criteria, in order to determine whether useful data could be obtained in this emergency context. RESULTS: Video-microscopy was successfully performed and stored for analysis for all patients, yielding 161 video clips. There were no adverse events or episodes where clinical management was affected or interrupted. There were 104 (64.6%) video clips from 14 patients of sufficient quality for analysis. CONCLUSIONS: Early sublingual microcirculatory monitoring in the ED for patients with THS is safe and feasible, even in a deployed military setting, and yields videos of satisfactory quality in a high proportion of cases. Further investigations of early microcirculatory behaviour in this context are warranted. TRIAL REGISTRATION NUMBER: NCT02111109.


Assuntos
Serviços Médicos de Emergência/métodos , Serviço Hospitalar de Emergência , Microcirculação , Monitorização Fisiológica/métodos , Soalho Bucal , Choque Hemorrágico/fisiopatologia , Ferimentos e Lesões/complicações , Adulto , Afeganistão , Serviços Médicos de Emergência/normas , Estudos de Viabilidade , Feminino , Instalações de Saúde , Humanos , Escala de Gravidade do Ferimento , Masculino , Microscopia de Vídeo/normas , Pessoa de Meia-Idade , Militares , Segurança do Paciente , Projetos Piloto , Estudos Prospectivos , Fluxo Sanguíneo Regional , Choque Hemorrágico/etiologia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...