Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37642480

RESUMO

OBJECTIVE: This study aimed to evaluate the risk factors and prevalence of intraoperative contamination (IoC) through the microbial culture of superficial and deep samples obtained during surgery. SUMMARY OF BACKGROUND DATA: Surgical site infection (SSI) in spinal surgery is a serious complication. The prevalence of IoC may differ based on surgical approach and technique, even in the setting of the same procedure. METHODS: In this in-vivo study, microbial cultivation was performed with superficial (ligamentum flavum, LF) and deep (nucleus pulposus, NP) surgical specimens to evaluate IoC in 132 patients undergoing single-level transforaminal lumbar interbody fusion (TLIF). Biportal endoscopic (BE) TLIF was performed under continuous wound irrigation (group A, n=66), whereas open microscopic (OM) TLIF was performed under intermittent wound irrigation (group B, n=66). LF and NP specimens were homogenized, gram-stained, and cultured in aerobic and anaerobic media for 14 days. Microbial culture results and occurrence of SSI in the two groups were assessed. The Chi-square test and Fisher's exact test were used to determine significant differences among categorical variables. Logistic regression analysis was used to assess the influence of patient characteristics on the prevalence of positive microbial cultures. RESULTS: Of the 132 patients, 34 (25.8%) had positive microbial cultures, and positive culture required an incubation period of 72 h to 2 weeks in all these patients except for three. Overall positive culture was significantly higher in group B than in group A (P=0.029). The subgroups of LF- and NP-positive cultures were 18.18% (n=24) and 12.88% (n=17), respectively; the SSI was 0.76% (n=1). Group A had a significantly lower subgroup of NP-positive culture than group B (P=0.035). OM technique was an independent risk factor associatd with overall positive culture (P<0.05). The most common microorganism was Cutibacterium acnes (C. acnes). CONCLUSION: BE-TLIF with continuous wound irrigation showed significantly lower overall, and NP-positive cultures, than OM-TLIF with intermittent irrigation. The most common strain of positive culture was C. acnes. LEVEL OF EVIDENCE: II.

2.
Acta Neurochir (Wien) ; 165(8): 2153-2163, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37407854

RESUMO

BACKGROUND: Lumbar foraminal stenosis (LFS) is an important pathologic entity that causes lumbar radiculopathies. Unrecognized LFS may be associated with surgical failure, and LFS remains challenging to treat surgically. This retrospective cohort study aimed to evaluate the clinical outcomes and prognostic factors of decompressive foraminotomy performed using the biportal endoscopic paraspinal approach for LFS. METHODS: A total of 102 consecutive patients with single-level unilateral LFS who underwent biportal endoscopic paraspinal decompressive foraminotomy were included. We evaluated the Visual Analogue Scale (VAS) score and the Oswestry Disability Index (ODI) before and after surgery. Demographic, preoperative data, and radiologic parameters, including the coronal root angle (CRA), were investigated. The patients were divided into Group A (satisfaction group) and Group B (unsatisfaction group). Parameters were compared between these two groups to identify the factors influencing unsatisfactory outcomes. RESULTS: In Group A (78.8% of patients), VAS and ODI scores significantly improved after biportal endoscopic paraspinal decompressive foraminotomy (p < 0.001). However, Group B (21.2% of patients) showed higher incidences of stenosis at the lower lumbar level (p = 0.009), wide segmental lordosis (p = 0.021), and narrow ipsilateral CRA (p = 0.009). In the logistic regression analysis, lower lumbar level (OR = 13.82, 95% CI: 1.33-143.48, p = 0.028) and narrow ipsilateral CRA (OR = 0.92, 95% CI: 0.86-1.00, p = 0.047) were associated with unsatisfactory outcomes. CONCLUSIONS: Significant improvement in clinical outcomes was observed for a year after biportal endoscopic paraspinal decompressive foraminotomy. However, clinical outcomes were unsatisfactory in 21.2% of patients, and lower lumbar level and narrow ipsilateral CRA were independent risk factors for unsatisfactory outcomes.


Assuntos
Foraminotomia , Estenose Espinal , Humanos , Descompressão Cirúrgica/efeitos adversos , Estudos Retrospectivos , Constrição Patológica/cirurgia , Resultado do Tratamento , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Endoscopia/efeitos adversos
3.
Acta Neurochir (Wien) ; 165(6): 1435-1443, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37115323

RESUMO

PURPOSE: The aim of this study was to introduce biportal endoscopic extraforaminal lumbar interbody fusion (BE-EFLIF), which involves insertion of a cage through a more lateral side as compared to the conventional corridor of transforaminal lumbar interbody fusion. We described the advantages and surgical steps of 3D-printed porous titanium cage with large footprints insertion through multi-portal approach, and preliminary results of this technique. METHODS: This retrospective study included 12 consecutive patients who underwent BE-EFLIF for symptomatic single-level lumbar degenerative disease. Clinical outcomes, including a visual analog scale (VAS) for back and leg pain and the Oswestry disability index (ODI), were collected at preoperative months 1 and 3, and 6 months postoperatively. In addition, perioperative data and radiographic parameters were analyzed. RESULTS: The mean patient age, follow-up period, operation time, and volume of surgical drainage were 68.3 ± 8.4 years, 7.6 ± 2.8 months, 188.3 ± 42.4 min, 92.5 ± 49.6 mL, respectively. There were no transfusion cases. All patients showed significant improvement in VAS and ODI postoperatively, and these were maintained for 6 months after surgery (P < 0.001). The anterior and posterior disc heights significantly increased after surgery (P < 0.001), and the cage was ideally positioned in all patients. There were no incidences of early cage subsidence or other complications. CONCLUSIONS: BE-EFLIF using a 3D-printed porous titanium cage with large footprints is a feasible option for minimally invasive lumbar interbody fusion. This technique is expected to reduce the risk of cage subsidence and improve the fusion rate.


Assuntos
Fusão Vertebral , Titânio , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Porosidade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Impressão Tridimensional
4.
Clin Orthop Surg ; 10(4): 462-467, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30505415

RESUMO

BACKGROUND: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. METHODS: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. RESULTS: The average VSA of the lateral column was 22° ± 6°, and that of the intermediate column was 29° ± 8° in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was 30 ± 3 mm at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. CONCLUSIONS: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.


Assuntos
Rádio (Anatomia)/anatomia & histologia , Adulto , Idoso , Povo Asiático/estatística & dados numéricos , Placas Ósseas , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/cirurgia , República da Coreia , Tomografia Computadorizada por Raios X , População Branca/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...