1.
Transfus Med ; 21(2): 90-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21118316

RESUMO

BACKGROUND: Advances in immunohaematology laboratory practice to improve performance, cost-effectiveness and patient safety are desirable. OBJECTIVES: To perform a multi-centre evaluation of the 8-column Grifols DG Gel(®) cards and reagent system to assess its performance, suitability and adaptability to the daily blood transfusion laboratory routine in the United Kingdom. METHODS/MATERIALS: A total of 4281 immunohematological analyses {1825 ABO/D grouping, 1921 antibody screening, 75 Rh phenotyping and K antigen determination, 361 antibody identification and 99 neonates [ABO/D and DAT (direct anti-globulin test)]} were performed on 2255 specimens. All cases were run in parallel with the reference method of each laboratory (DiaMed-ID(®) cards or conventional tube technique in some cases). RESULTS: Concordant results between Grifols DG Gel(®) system and the reference method were obtained in 97·7% of tests. For ABO grouping by the Grifols DG Gel(®) system, sensitivity was 99·95%, specificity was 99·96%, predictive positive value (PPV) was 99·89% and predictive negative value (PNV) was 99·98%. For D grouping, sensitivity was 99·78%, specificity was 100%, PPV was 100% and PNV was 99·78%. For antibody screening, sensitivity was 90·63%, specificity was 99·94%, PPV was 99·32% and PNV was 99·15%. Of the Rh subgroups and K types, results were 100% concordant. For antibody specificity detection, accuracy was 96·95% for Grifols DG Gel(®) system and 95·29% for DiaMed-ID(®) system. For the newborn tests, concordant results were obtained in 100% of ABO/D grouping and in 89·9% of DAT. CONCLUSION: The Grifols DG Gel(®) 8-column system is reliable and safe for routine tests performed in the immunohaematology laboratory.


Assuntos
Testes Diagnósticos de Rotina/instrumentação , Testes de Hemaglutinação/instrumentação , Adulto , Anticorpos/sangue , Automação , Antígenos de Grupos Sanguíneos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Transfusão de Sangue , Teste de Coombs/instrumentação , Géis , Humanos , Indicadores e Reagentes , Recém-Nascido , Triagem Neonatal/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...