Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-915501

RESUMO

Poor graft function (PGF) is a serious, potentially life-threatening complication of allogeneic hematopoietic stem cell transplantation. Eltrombopag has shown multilineage responses in patients with refractory severe aplastic anemia, supporting the idea that it may improve cytopenia in patients with PGF. This retrospective, single center analysis included 8 Korean patients receiving eltrombopag for PGF. Median interval between transplant and eltrombopag treatment was 73 days, and the median duration treatment was 3.5 weeks.With median maximum daily dose of 50 mg, the time to best response was 93 days. Median hemoglobin increased from 8.2 g/dL to 10.9 g/dL, platelet from 18.5 × 109 /L to 54 × 109 /L, and absolute neutrophil count from 1.25 × 109 /L to 3.32 × 109 /L. In conclusion, eltrombopag is a good option for PGF in Korean patients, even at a lower dose compared to western patients.

2.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-71459

RESUMO

PURPOSE: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). MATERIALS AND METHODS: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and T2*-weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. RESULTS: Three phases of alpha'-martensite, gamma-austenite, and epsilon-martensite were seen on XRD, and their composition changed from alpha'-martensite to gamma-austenite and/or epsilon-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised alpha'-martensite, the Fe-20Mn and Fe-25Mn specimens comprised gamma+epsilon phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single gamma phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. CONCLUSION: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of gamma-austenite and/or epsilon-martensite.


Assuntos
Ligas , Angiografia , Artefatos , Constituição e Estatutos , Campos Magnéticos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Manganês , Stents , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...