Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 179: 113065, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33578116

RESUMO

Recombinase polymerase amplification (RPA) is considered one of the best amplification methods for realizing a miniaturized diagnostic instrument; however, it is notably challenging to obtain low detection limits in solid-phase RPA. To overcome these difficulties, we combined solid-phase RPA with electrochemical detection and used a new concentration combination of three primers (surface-bound forward primer, solution reverse primer, and an extremely low concentration of solution forward primer). When solid-phase RPA was performed on an indium tin oxide (ITO) electrode modified with a surface-bound forward primer in a solution containing a biotin-terminated solution reverse primer, an extremely low concentration of a solution forward primer, and a template DNA or genomic DNA for a target gene of hepatitis B virus (HBV), amplification occurred mainly in solution until all the solution forward primers were consumed. Subsequently, DNA amplicons produced in solution participated in solid-phase amplification involving surface-bound forward primer and solution reverse primer. Afterward, neutravidin-conjugated DT-diaphorase (DT-D) was attached to a biotin-terminated DNA amplicon on the ITO electrode. Finally, chronocoulometric charges were measured using electrochemical-enzymatic redox cycling involving the ITO electrode, 1,4-naphthoquinone, DT-D, and reduced ß-nicotinamide adenine dinucleotide. The detection limit for HBV was measured using microfabricated electrodes and was found to be approximately 0.1 fM. This proposed method demonstrated better amplification efficiency for HBV genomic DNA than solid-phase RPA without using additional solution primer and asymmetric solid-phase RPA.


Assuntos
Técnicas Biossensoriais , Hepatite B , DNA Viral/genética , Hepatite B/diagnóstico , Humanos , Técnicas de Amplificação de Ácido Nucleico , Recombinases , Sensibilidade e Especificidade
2.
ACS Sens ; 4(11): 2966-2973, 2019 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-31647639

RESUMO

Carboxyl esterases show limited use as catalytic labels in bioassays because of slow enzymatic reaction. We report that DT-diaphorase from Bacillus stearothermophilus (DT-D, EC 1.6.99.-) shows high carboxyl esterase-like activity in the presence of reduced ß-nicotinamide adenine dinucleotide (NADH) and may be used as a better catalytic label than carboxyl esterases. DT-D is a redox enzyme and can participate in signal-amplifying redox cycling. Thus, an electrochemical immunosensor using a DT-D label allows for triple signal amplification based on (i) hydrolysis of a carboxyl ester, (ii) electrochemical-chemical (EC) redox cycling involving an electrode, a hydrolysis product, and NADH, and (iii) electrochemical-enzymatic (EN) redox cycling involving an electrode, a hydrolysis product, DT-D, and NADH. Ester hydrolysis by DT-D is confirmed via spectrophotometric measurement of a chromogenic substrate (4-nitrophenyl acetate) and 1H NMR spectra. Among two phenyl acetates and four naphthyl acetates considered, 4-aminonaphthalene-1-yl acetate (4-NH2-NAc) is chosen as the best acetyl ester substrate because 4-NH2-NAc is stable, its hydrolysis is slow in the absence of DT-D, its hydrolysis is very fast in the presence of DT-D, and EC and EN redox cycling involving the hydrolysis product (4-amino-1-naphthol) is rapid. However, hydrolysis of 4-NH2-NAc by esterase from porcine liver (EC 3.1.1.1.) is very slow. When DT-D is applied to sandwich-type detection of thyroid-stimulating hormone in artificial serum, the detection limit is ∼2 pg/mL, indicating that the developed immunosensor is highly sensitive because of triple signal amplification. DT-D may be used as a catalytic label in sensitive and stable bioassays instead of common alkaline phosphatase and horseradish peroxidase.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Geobacillus stearothermophilus/enzimologia , Imunoensaio , NAD(P)H Desidrogenase (Quinona)/metabolismo , Eletrodos , Hidrólise , NAD(P)H Desidrogenase (Quinona)/análise , Oxirredução
3.
Anal Chem ; 91(7): 4680-4686, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30882203

RESUMO

DT-diaphorase (DT-D) is known to mainly catalyze the two-electron reduction of quinones and nitro(so) compounds. Detection of Gram-negative bacterial outer membrane vesicles (OMVs) that contain pyrogenic lipopolysaccharides (LPSs, also called endotoxins) is required for evaluating the toxic effects of analytical samples. Here, we report that DT-D has a high dephosphorylation activity: DT-D catalyzes reductive dephosphorylation of a phosphate-containing substrate in the presence of NADH. We also report that sensitive and simple OMV detection is possible with a sandwich-type electrochemical immunosensor using DT-D and two identical LPS-binding antibodies as a catalytic label and two sandwich probes, respectively. The absorbance change in a solution containing 4-nitrophenyl phosphate indicates that dephosphorylation occurs in the presence of both DT-D and NADH. Among the three phosphate-containing substrates [4-aminophenyl phosphate, ascorbic acid phosphate, and 1-amino-2-naphthyl phosphate (ANP)] that can be converted into electrochemically active products after dephosphorylation, ANP shows the highest electrochemical signal-to-background ratio, because (i) the dephosphorylation of ANP by DT-D is fast, (ii) the electrochemical oxidation of the dephosphorylated product (1-amino-2-naphthol, AN) is rapid, even at a bare indium-tin oxide electrode, and (iii) two redox cycling processes significantly increase the electrochemical signal. The two redox cycling processes include an electrochemical-enzymatic redox cycling and an electrochemical-chemical redox cycling. The electrochemical signal in a neutral buffer (tris buffer, pH 7.5) is comparable to that in a basic buffer (tris buffer, pH 9.5). When the immunosensor is applied to the detection of OMV from Escherichia coli, the detection limit is found to be 8 ng/mL. This detection strategy is highly promising for the detection of biomaterials, including other extracellular vesicles.


Assuntos
Escherichia coli/química , Vesículas Extracelulares/química , NAD(P)H Desidrogenase (Quinona)/metabolismo , Monoéster Fosfórico Hidrolases/metabolismo , Biocatálise , NAD(P)H Desidrogenase (Quinona)/química , Monoéster Fosfórico Hidrolases/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...