Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 230
Filtrar
1.
J Vasc Interv Radiol ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38705571

RESUMO

PURPOSE: To evaluate the long-term efficacy and safety of proprietary transperineal laser ablation (TPLA) of the prostate. MATERIALS AND METHODS: Patients with symptomatic benign prostatic hyperplasia underwent TPLA with a 1064-nm continuous-wave diode laser. IPSS, QoL, PVR and prostate volume were evaluated at baseline and successive timepoints. RESULTS: Forty prospectively enrolled patients had post-TPLA follow-up of ≥ 36 months. Median duration of follow-up was 56.5 months (range: 36-76 months). Compared with baseline, the median reduction in IPSS at 12-month follow-up was 74% (interquartile range [IQR]: 60-81%) (P < .001). Median QoL score at 12 months was improved from 5 (IQR: 4-5) at baseline to 1 (IQR: 0-1) (P < .001). Median PVR at 12 months decreased from 108 mL (IQR: 38-178 mL) to 13.5 mL (IQR: 0-40.5 mL) (P < .001), a median reduction of 88% (IQR: 61-100%). At 12 months, median prostate volume was significantly reduced from 66 mL (IQR: 48.5-86.5 mL) to 46 mL (IQR 36-65 mL) (P < .001), a median reduction of 32% (IQR: 21-45%). For all of these parameters, the benefit of TPLA persisted at last follow-up and all changes were statistically significant vs baseline. There were no intraoperative adverse events; perioperative adverse events consisted of one case of prostatitis and one case of urinary tract infection (both mild according to the modified SIR classification system). CONCLUSION: TPLA for symptomatic BPH produced durable benefits across a range of clinical outcomes and was well tolerated in 56.5 months median duration follow-up.

2.
J Pers Med ; 14(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38672992

RESUMO

The liver is the second most common solid organ injured in blunt and penetrating abdominal trauma. Non-operative management (NOM) has become the standard of care for liver injuries in stable patients, where transarterial embolization (TAE) represents the main treatment, increasing success rates and avoiding invasive surgical procedures. In hemodynamically (HD) unstable patients, operative management (OM) is the standard of care. To date, there are no consensus guidelines about the endovascular treatment of patients with HD instability or in ones that responded to initial infusion therapy. A review of the literature was performed for published papers addressing the outcome of using TAE as the primary treatment for HD unstable/transient responder trauma liver patients with hemorrhagic vascular lesions, both as a single treatment and in combination with surgical treatment, focusing additionally on the different definitions used in the literature of unstable and transient responder patients. Our review demonstrated a good outcome in HD unstable/transient responder liver trauma patients treated with TAE but there still remains much debate about the definition of unstable and transient responder patients.

3.
CVIR Endovasc ; 7(1): 6, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180623

RESUMO

The aim of the article is to introduce a new term in post-procedural events related to the procedure itself. All the Societies and Councils report these events as complications and they are divided in mild, moderate and severe or immediate and delayed.On the other hand the term error is known as the application of a wrong plan, or strategy to achieve a goal.For the first time, we are trying to introduce the term "consequence"; assuming that the procedure is the only available and the best fit to clinical indication, a consequence should be seen as an expected and unavoidable occurrence of an "adverse event" despite correct technical execution.

4.
Clin Genitourin Cancer ; 22(2): 237-243, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38065718

RESUMO

BACKGROUND: Robot assisted partial nephrectomy (RAPN) and microwave ablation (MWA) are 2 of the most advanced techniques for the management of localized small renal masses. PURPOSE: To compare the perioperative, functional and oncological results of RAPN and MWA. MATERIALS AND METHODS: Data from 171 consecutive patients undergoing either RAPN or MWA for a localized small renal mass at a single academic center was retrospectively collected. Baseline features included patients' demographics and masses' characteristics. Procedures were compared in terms of perioperative outcomes and renal function variation Progression of a persistent lesion or local recurrence after a complete treatment defined local tumor progression. Descriptive statistics and survival analysis tested the association between predictors and local tumor progression. RESULTS: Of all, 109 and 62 patients underwent RAPN and MWA. Patients in the MWA group were older (P = .002) had higher Charlson Comorbidity Index (CCI) (P < .001) and higher frequency of preoperative chronic kidney disease (P < .001). MWA led to a shorter postoperative hospitalization time (P < .001) and lower incidence of medical complications (6.5% vs. 22.9%, P = .02) than RAPN. GFR decline was similar between groups both at discharge (P = .39) and at the time of last follow up (P = 1.00). A lower rate of secondary interventions (11.7% vs. 2.8%, P = .037) and a better disease-free survival (83.2% vs. 96.5%, P = .027) were reported after RAPN. Conversely, cancer specific and overall survival were comparable (P > .05). At univariate regression analysis, MWA was associated with local tumor progression (HR 3.46, P = .040). CONCLUSION: MWA displayed a lower perioperative impact, while functional outcomes were similar after each intervention. RAPN resulted superior in terms of tumor eradication, but no difference was noted regarding cancer specific survival. Thus, MWA represents a valid alternative in frail patients, though less radical than RAPN.


Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Neoplasias Renais/patologia , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Nefrectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos
5.
J Clin Med ; 12(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38068478

RESUMO

The aim of the study was to try to obtain more information on diagnostic samplings and biomarkers using dual-layer spectral CT in lung biopsies. Lung biopsies were performed by merging images obtained with CBCT with those from spectral CT to use them as functional guidance, experimenting with double sampling to determine the difference between the area with a higher Z-effective number and that with a lower Z-effective number. Ten patients with large lung lesions on spectral CT were selected and underwent percutaneous transthoracic lung mass biopsy. Technical success was calculated. The percentage of neoplastic, inflammatory, fibrotic, necrotic cells, or non-neoplastic lung parenchyma was reported. The possibility of carrying out immunohistochemical or molecular biology investigations was analyzed. All lesions were results malignant in 10/10 samples in the Zmax areas; in the Zmin areas, malignant cells were found in 7/10 samples. Technical success was achieved in 100% of cases for Zmax sampling and in 70% for Zmin sampling (p-value: 0.2105). The biomolecular profile was detected in 9/10 (90%) cases in Zmax areas, while in 4/10 (40%) cases in Zmin areas (p-value: 0.0573). The advantage of Z-effective imaging would be to identify a region of the lesion that is highly vascularized and probably richer in neoplastic cells, thus decreasing the risk of obtaining a non-diagnostic biopsy sample.

6.
J Endovasc Ther ; : 15266028231217233, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38062565

RESUMO

OBJECTIVE: To report on the recommendations of an expert-based consensus on the indications, timing, and techniques of aortic balloon occlusion (ABO) in the management of ruptured abdominal aortic aneurysms (rAAA). METHODS: Eleven facilitators created appropriate statements regarding the study issues that were voted on using a 4-point Likert scale with open-comment fields, by a selected panel of international experts (vascular surgeons and interventional radiologists) using a 3-round modified Delphi consensus procedure (study period: January-April 2023). Based on the experts' responses, only the statements reaching grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final study report. The consistency of each round's answers was also graded using Cohen's kappa, the intraclass correlation coefficient, and, in case of double resubmission, Fleiss kappa. RESULTS: Sixty-three experts were included in the final analysis and voted on 25 statements related to indication and timing (n=6), and techniques (n=19) of ABO in the setting of rAAA. Femoral sheath or ABO should be preferably placed in the operating room, via a percutaneous transfemoral access, on a stiff wire (grade B, consistency I), ABO placement should be suprarenal and last less than 30 minutes (grade B, consistency II), postoperative peripheral vascular status (grade A, consistency II) and laboratory testing every 6 to 12 hours (grade B, consistency) should be assessed to detect complications. Formal training for ABO should be implemented (grade B, consistency I). Most of the statements in this international expert-based Delphi consensus study might guide current choices for indications, timing, and techniques of ABO in the management of rAAA. Clinical practice guidelines should incorporate dedicated statements that can guide clinicians in decision-making. CONCLUSIONS: At arrival and during both open or endovascular procedures for rAAA, selective use of intra-aortic balloon occlusion is recommended, and it should be performed preferably by the treating physician in aortic pathology. CLINICAL IMPACT: This is the first consensus study of international vascular experts aimed at defining the indications, timing, and techniques of optimal use of ABO in the clinical setting of rAAA. Aortic occlusion by endovascular means (or ABO) is a quick procedure in properly trained hands that may play an important role as a temporizing measure until the definitive aortic repair is achieved, whether by endovascular or open means. Since data on its use in hemodynamically unstable patients are limited in the literature, owing to practical challenges in the performance of well-conducted prospective studies, understanding real-world use by experts is of importance in addressing critical issues and identifying main gaps in knowledge.

7.
J Clin Med ; 12(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137667

RESUMO

PURPOSE: to evaluate the clinical impact of a protocol for the image-guided percutaneous microwave ablation (MWA) of hepatocellular carcinoma (HCC) that includes cone-beam computed tomography (CBCT), fusion imaging and ablation volume prediction in patients with hepatocellular carcinoma unsuitable for standard ultrasound (US) guidance. MATERIALS AND METHODS: this study included all patients with HCC treated with MWA between January 2021 and June 2022 in a tertiary institution. Patients were divided into two groups: Group A, treated following the protocol, and Group B, treated with standard ultrasound (US) guidance. Follow-up images were reviewed to assess residual disease (RD), local tumor progression (LTP) and intrahepatic distant recurrence (IDR). Ablation response at 1 month was also evaluated according to mRECIST. Baseline variables and outcomes were compared between the groups. For 1-month RD, propensity score weighting (PSW) was performed. RESULTS: 80 consecutive patients with 101 HCCs treated with MWA were divided into two groups. Group A had 41 HCCs in 37 patients, and Group B had 60 HCCs in 43 patients. Among all baseline variables, the groups differed regarding their age (mean of 72 years in Group A and 64 years in Group B, respectively), new vs. residual tumor rates (48% Group A vs. 25% Group B, p < 0.05) and number of subcapsular tumors (56.7% Group B vs. 31.7% Group A, p < 0.05) and perivascular tumors (51.7% Group B vs. 17.1% Group A, p < 0.05). The protocol led to repositioning the antenna in 49% of cases. There was a significant difference in 1-month local response between the groups measured as the RD rate and mRECIST outcomes. LTP rates at 3 and 6 months, and IDR rates at 1, 3 and 6 months, showed no significant differences. Among all variables, logistic regression after PSW demonstrated a protective effect of the protocol against 1-month RD. CONCLUSIONS: The use of CBCT, fusion imaging and ablation volume prediction during percutaneous MWA of HCCs provided a better 1-month tumor local control. Further studies with a larger population and longer follow-up are needed.

8.
J Clin Med ; 12(24)2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38137745

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is a cancer with one of the highest mortality rates in the world. Several studies have been conductedusing preclinical experiments in mice to find new therapeutic strategies. Experimental ultrasound, in expert hands, is a safe, multifaceted, and relatively not-expensive device that helps researchers in several ways. In this systematic review, we propose a summary of the applications of ultrasonography in a preclinical mouse model of PDAC. Eighty-eight studies met our inclusion criteria. The included studies could be divided into seven main topics: ultrasound in pancreatic cancer diagnosis and progression (n: 21); dynamic contrast-enhanced ultrasound (DCE-US) (n: 5); microbubble ultra-sound-mediated drug delivery; focused ultrasound (n: 23); sonodynamic therapy (SDT) (n: 7); harmonic motion elastography (HME) and shear wave elastography (SWE) (n: 6); ultrasound-guided procedures (n: 9). In six cases, the articles fit into two or more sections. In conclusion, ultrasound can be a really useful, eclectic, and ductile tool in different diagnostic areas, not only regarding diagnosis but also in therapy, pharmacological and interventional treatment, and follow-up. All these multiple possibilities of use certainly represent a good starting point for the effective and wide use of murine ultrasonography in the study and comprehensive evaluation of pancreatic cancer.

9.
J Clin Med ; 12(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38002726

RESUMO

Chronic mesenteric ischemia (CMI) arises from the inability to achieve adequate intestinal blood flow after meals, leading to an imbalance between oxygen and metabolite supply and demand. The true incidence of CMI remains uncertain. However, the occurrence of mesenteric artery occlusive disease (MAOD) is relatively common among the elderly population. Delays in diagnosing CMI can often be attributed to several factors, including the variability in patient symptoms and the range of potential causes for chronic abdominal pain with weight loss. Mikkelson pioneered the introduction of a surgical treatment for occlusive lesions of the superior mesenteric artery (SMA) in 1957. The inaugural performance of endovascular revascularization (ER) for visceral vessels took place in 1980. The literature has documented two types of endovascular revascularization (ER) methods: percutaneous transluminal angioplasty (PTA) and primary stenting (PMAS). Despite the limited quality of available evidence, the consensus among experts is strongly in favor of PMAS over PTA alone for the treatment of atherosclerotic mesenteric artery stenosis. There are several key areas of focus for chronic mesenteric ischemia (CMI) treatment. Randomized controlled trials comparing different stent types, such as covered stents versus bare metal stents, are needed to evaluate efficacy, patency rates, and long-term outcomes in CMI patients.

10.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892768

RESUMO

PURPOSE: The present study aims to evaluate the effectiveness and safety of the anti-reflux microcatheter during DEB-TACE with DC Bead LUMITM (radiopaque beads) for the treatment of hepatocellular carcinoma (HCC). METHODS: We performed an observational longitudinal prospective monocentric study to analyze all patients with HCC who underwent to DEB-TACE with DC Bead LUMITM and anti-reflux microcatheter. Technical success, the presence of residual disease, and clinical success were evaluated. The performance of the anti-reflux microcatheter on the basis of the percentage of tumor covered and the non-target embolization (NTE) was also evaluated. RESULTS: Twenty patients underwent DEB-TACE with DC Bead LUMITM and an anti-reflux microcatheter. Technical success was achieved in all cases. Residual disease in the target tumor was observed in 11/20 (55%) of cases and no residual disease was found in 9/20 (45%) of cases. The clinical response at 1-month follow-up was of PD 4/20 (20%), SD 7/20 (35%), and CR 9/20 (45%). No major complications were recorded, and 10% of cases had minor complications. The distribution of beads on post-procedural CBCT, classified according to the percentage of target nodule coverage, was ≥50% in 70% (14/20) of cases and between 30-50% in 30% of cases (6/20). NTE was never registered.

11.
J Transl Int Med ; 11(3): 198-202, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37662891

RESUMO

Thrombolysis is not currently recommended in cirrhotic patients with acute portal vein thrombosis (PVT) in most guidelines, because of the exceedingly limited data and the perceived high risk of bleeding adverse events. However, in the few studies including patients with cirrhosis, the rate of success was high and that of adverse events was similar in patients with or without cirrhosis. Hence, thrombolysis might be a rescue therapeutic option in patients with cirrhosis and acute, symptomatic thrombosis of the portal venous system, unresponsive to anticoagulation, provided a suitable timing is kept, less than 30 days and, if possible, less than 14 days from the acute onset of portal vein thrombosis. In this review perspective article, I discuss the several potential approaches of thrombolysis, either local or systemic, alone or combined with mechanical procedures for thrombus removal, or as a complement to Transjugular Intrahepatic Portosystemic Shunt placement, with a focus on the more suitable timing of thrombolysis. However, the very limited available data preclude from performing firm recommendations, and decision to carry out thrombolysis must take into account both the occurrence of major contraindications and the current critical clinical setting. In the next future, large high-quality multicentre studies will hopefully be able to settle more firm indications and preferable techniques.

12.
Int J Mol Sci ; 24(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37628865

RESUMO

Despite the advances made in treatment, the prognosis of pancreatic ductal adenocarcinoma (PDAC) remains dismal, even in the locoregional and locally advanced stages, with high relapse rates after surgery. PDAC exhibits a chemoresistant and immunosuppressive phenotype, and the tumor microenvironment (TME) surrounding cancer cells actively participates in creating a stromal barrier to chemotherapy and an immunosuppressive environment. Recently, there has been an increasing use of interventional radiology techniques for the treatment of PDAC, although they do not represent a standard of care and are not included in clinical guidelines. Local approaches such as radiation therapy, hyperthermia, microwave or radiofrequency ablation, irreversible electroporation and high-intensity focused ultrasound exert their action on the tumor tissue, altering the composition and structure of TME and potentially enhancing the action of chemotherapy. Moreover, their action can increase antigen release and presentation with T-cell activation and reduction tumor-induced immune suppression. This review summarizes the current evidence on locoregional therapies in PDAC and their effect on remodeling TME to make it more susceptible to the action of antitumor agents.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Microambiente Tumoral , Recidiva Local de Neoplasia , Neoplasias Pancreáticas/terapia , Carcinoma Ductal Pancreático/terapia , Neoplasias Pancreáticas
13.
Technol Cancer Res Treat ; 22: 15330338231184840, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37592839

RESUMO

PURPOSE: The aim of this study was to describe the safety and efficacy profiles of TACE using DC Beads LUMI. MATERIALS AND METHODS: We retrospectively analyzed 90 patients with HCC who underwent TACE with DC Bead LUMI™ between November 2018 and November 2020 at Fondazione IRCCS Cà Granda Policlinico Hospital in Milan, Italy. Patient- and tumour-related factors were registered, including the number of treated lesions, dose of DC Beads LUMI™, dose of Epirubicin, DC Beads LUMI™ target tumour coverage (LC) according to the percentage of target nodule involvement (LC1-0%-25%, LC2-25%-50%, LC3-50%-75%, LC4 75%-100%). Treatment efficacy was obtained through reviewing the follow-up imaging for evidence of response in target lesion(s), according to modified response criteria in solid tumours (mRECIST) criteria with the following outcomes: complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD). Safety assessment was based on the quantitative and qualitative recording of the adverse events, classified according to CIRSE classification. RESULTS: Seventy-two patients were enrolled, and 95 procedures were carried out. We observed a target tumour response rate at 1 month with CR in 68%, PR in 10.3% 11.8%, SD in 13%, PD in 7.2%, and an overall tumour(s) (whole liver) response at 1 month with CR in 58.9%, PR in 12.6%, SD in 10.5% and PD in 18%. We found a significant association (p < 0.01) between tumour response CR or CR + PR and the number of the target lesion(s). CIRSE classification grade I and grade II complications were recorded, respectively, in 11 (11.6%) and 6 (6.3%) procedures. No grade III-IV-V complications occurred. CONCLUSION: TACE using DC Beads LUMI is a safe and effective treatment option for patients with HCC.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Quimioembolização Terapêutica/métodos , Resultado do Tratamento
14.
Technol Cancer Res Treat ; 22: 15330338231181284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608564

RESUMO

Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of "Prediction Ablation Volume Software" may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) "Prediction Ablation Volume Software." This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Ablação por Cateter/métodos
15.
Technol Cancer Res Treat ; 22: 15330338231185277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608585

RESUMO

OBJECTIVE: The aim of this study is to evaluate the feasibility, safety, and short-term effectiveness of a high-power (150 W) microwave ablation (MWA) device for tumor ablation in the lung, liver, and kidney. METHODS: Between December 2021 and June 2022, patients underwent high-power MWA for liver, lung, and kidney tumors. A retrospective observational study was conducted in accordance with the Declaration of Helsinki. The MWA system utilized a 150-W, 2.45-GHz microwave generator (Emprint™ HP Ablation System, Medtronic). The study assessed technical success, safety, and effectiveness, considering pre- and post-treatment diameter and volume, lesion location, biopsy and/or cone beam computed tomography (CBCT) usage, MWA ablation time, MWA power, and dose-area product (DAP). RESULTS: From December 2021 to June 2022, 16 patients were enrolled for high-power MWA. Treated lesions included hepatocellular carcinoma (10), liver metastasis from colon cancer (1), liver metastasis from pancreatic cancer (1), squamous cell lung carcinoma (2), renal cell carcinoma (1), and renal oncocytoma (1). Technical success rate was 100%. One grade 1 complication (6.25%) was reported according to CIRSE classification. Overall effectiveness was 92.8%. Pre- and post-treatment mean diameters for liver lesions were 19.9 mm and 37.5 mm, respectively; for kidney lesions, 34 mm and 35 mm; for lung lesions, 29.5 mm and 31.5 mm. Pre- and post-treatment mean volumes for liver lesions were 3.4 ml and 24 ml, respectively; for kidney lesions, 8.2 ml and 20.5 ml; for lung lesions, 10.2 ml and 32.7 ml. The mean ablation time was 48 minutes for liver, 42.5 minutes for lung, and 42.5 minutes for renal ablation. The mean DAP for all procedures was 40.83 Gcm2. CONCLUSION: This preliminary study demonstrates the feasibility, safety, and effectiveness of the new 150 W MWA device. Additionally, it shows reduced ablation times for large lesions.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Rim/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
Diagnostics (Basel) ; 13(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37510092

RESUMO

Percutaneous image-guided thermal ablation is included in most society guidelines for treatment of hepatocellular carcinoma (HCC). The results of this treatment in terms of efficacy depend on the ability to precisely place the device into the target tumor. Ultrasound (US) is a commonly used imaging guidance modality for its real-time feedback. However, an accurate device deployment remains challenging in some clinical scenarios, including cases of tumors that are undetectable or not clearly visible by US. To overcome this problem, fusion imaging techniques have been developed, which combine images from different modalities. The most widely known technique combines pre-procedural contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI) with real-time US scans. Cone beam CT (CBCT) is a technology that can provide intra-procedural cross-sectional images, which can be registered to images from other modalities, including preprocedural CT/MR scans. The aim of our study is to report the preliminary experience on percutaneous microwave ablation (MWA) of patients with HCC that were treated using the "double fusion" technique, which combines the use of US fusion imaging and CBCT fusion imaging. We describe the technical details, feasibility, safety and short-term efficacy of this technique in a small series of eight patients with 11 HCCs.

18.
J Clin Med ; 12(11)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37297991

RESUMO

The purpose of this bicentric case series was to report the safety, efficacy, and clinical outcome of transcatheter embolization in pulmonary artery pseudoaneurysms (PAPAs). Between January 2016 and June 2021, eight patients with PAPA were subjected to transcatheter embolization. The total number of patients was eight, of which five were female, with a mean age of 62 ± 14 years (average ± standard deviation). Etiology was traumatic in 2/8 cases and iatrogenic in 6/8 cases (after positioning a Swan-Ganz catheter in 5/6 cases and a temporary pacemaker in the latter case). In a single case, the PAPA was incidentally discovered during a routine X-ray, in the remaining 7 cases, the procedure was performed in emergency settings. PAPA embolization was performed using detachable coils alone in 3 cases; coils and glue in 1 case; coils, glue, and vascular plug in 1 case; coils and non-adhesive liquid embolic agents (Onyx and Squid respectively) in 2 cases; and non-adhesive liquid embolic agent alone (Onyx) in 1 case. No peri-procedural or post-procedural complications were recorded. Both the technical and clinical success rates were 100.0%. In conclusion, endovascular embolization is a technically feasible and safe therapeutic option for patients with PAPAs.

19.
Semin Vasc Surg ; 36(2): 283-299, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330241

RESUMO

Endovascular embolization of bleeding vessels in trauma and non-trauma patients is frequently used and is an important tool for bleeding control. It is included in the EVTM (endovascular resuscitation and trauma management) concept and its use in patients with hemodynamic instability is increasing. When the correct embolization tool is chosen, a dedicated multidisciplinary team can rapidly and effectively achieve bleeding control. In this article, we will describe the current use and possibilities for embolization of major hemorrhage (traumatic and non-traumatic) and the published data supporting these techniques as part of the EVTM concept.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Embolização Terapêutica/efeitos adversos , Hemorragia/etiologia , Hemorragia/terapia , Ressuscitação/efeitos adversos , Ressuscitação/métodos
20.
Semin Vasc Surg ; 36(2): 307-318, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37330243

RESUMO

"Acute venous problems" refers to a group of disorders that affect the veins and result in sudden and severe symptoms. They can be classified based on the pathological triggering mechanisms, such as thrombosis and/or mechanical compression, and their consequences, including symptoms, signs, and complications. The management and therapeutic approach depend on the severity of the disease, the location, and the involvement of the vein segment. Although summarizing these conditions can be challenging, the objective of this narrative review was to provide an overview of the most common acute venous problems. This will include an exhaustive yet concise and practical description of each condition. The multidisciplinary approach remains one of the major advantages in dealing with these conditions, maximizing the results and the prevention of complications.


Assuntos
Filtros de Veia Cava , Trombose Venosa , Humanos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Veias/diagnóstico por imagem , Veias/cirurgia , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...