Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Cureus ; 16(1): e52779, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38389634

RESUMO

Purpose To elucidate the utility of a navigated high-speed drill used after the version upgrade in surgeries assisted by a spinal robotics system. Methods The subjects were 166 patients who underwent screw placement using a spinal robotics system between April 2021 to July 2023. A significant change during the study was the introduction of a navigated high-speed drill in 80 post-upgrade cases, aimed at improving drilling accuracy. Screw accuracy was analyzed using the Gertzbein and Robbins classification on postoperative CT scans. Screws placed before (pre-upgrade group: 718 screws in 86 cases) and after the system upgrade (post-upgrade group: 747 screws in 80 cases) were compared in terms of perfect accuracy and deviation rates. Results There were no significant differences in demographics or surgical details between the two groups. No significant differences were observed in the overall perfect accuracy rate and deviation rate (2.4% pre-upgrade vs. 2.0% post-upgrade) between the two groups. For the percutaneous pedicle screw (PPS), the perfect accuracy rate was significantly higher, and the deviation rate was significantly lower in the post-upgrade group (26.1% pre-upgrade vs. 4.4% post-upgrade). Notably, the post-upgrade group achieved 100% perfect accuracy and 0% deviation for the cortical bone trajectory screw (CBT) technique. Conclusions The introduction of the navigated high-speed drill did not significantly alter the overall perfect accuracy or deviation rates for robotic-assisted screw placement. However, its use did demonstrate improved outcomes in specific techniques such as PPS and CBT, indicating its potential value in addressing skiving in robotic-assisted minimally invasive surgeries.

2.
Eur J Orthop Surg Traumatol ; 34(1): 127-134, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37358731

RESUMO

PURPOSE: The purpose of this study was to clarify the learning curve for robotic-assisted spine surgery. We analyzed the workflow in robotic-assisted spine surgery and investigated how much experience is required to become proficient in robotic-assisted spine surgery. METHODS: The data were obtained from consecutive 125 patients who underwent robotic-assisted screw placement soon after introducing a spine robotic system at a single center from April 2021 to January 2023. The 125 cases were divided into phases 1-5 of sequential groups of 25 cases each and compared for screw insertion time, robot setting time, registration time, and fluoroscopy time. RESULTS: There were no significant differences in age, body mass index, intraoperative blood loss, number of fused segments, operation time, or operation time per segment between the 5 phases. There were significant differences in screw insertion time, robot setting time, registration time, and fluoroscopy time between the 5 phases. The screw insertion time, robot setting time, registration time, and fluoroscopy time in phase 1 were significantly longer than those in phases 2, 3, 4, and 5. CONCLUSION: In an analysis of 125 cases after the introduction of the spine robotic system, the screw insertion time, robot setting time, registration time, and fluoroscopy time were significantly longer in the 25 cases in the period initially after introduction. The times were not significantly different in the subsequent 100 cases. Surgeons can be proficient in robotic-assisted spine surgery after their experience with 25 cases.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Curva de Aprendizado , Parafusos Ósseos , Fluoroscopia , Estudos Retrospectivos
3.
Cureus ; 15(11): e49061, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38116336

RESUMO

Purpose This study aimed to compare the radiographic and patient-reported outcomes after surgery in adolescent idiopathic scoliosis (AIS) between robotics and navigation using propensity score matching. Methods This retrospective study involved 50 patients undergoing posterior spinal fusion for AIS between October 2016 and August 2022, utilizing navigation or robotic systems, analyzing them using propensity score matching. The evaluations included assessments using X-ray, Scoliosis Research Society 22-Item (SRS-22) Questionnaire, and CT, considering variables such as age, gender, BMI, and Lenke type. Results Post matching, 13 cases each from robotics and navigation groups were compared. No significant differences were found in the demographic variables, preoperative X-ray parameters, and preoperative SRS-22 scores between the two groups. The robotics group demonstrated a higher perfect accuracy rate (94.0% vs. 84.7%, p=0.005) and a lower deviation rate in pedicle screw placements (1.6% vs. 4.1%, p=0.223). At one year postoperatively, there were no significant differences in the X-ray parameters between both groups. Likewise, no significant differences were found in each domain of SRS-22, but function, self-image, mental health, and satisfaction scores were numerically higher in the robotics group. Conclusion The application of a spinal robotic system in AIS surgery presented enhanced screw accuracy and lower deviation rates, compared to navigation, with no significant differences observed in the X-ray parameters and each domain of SRS-22 at one year postoperatively. This suggests that, to improve patient quality of life (QOL), it is essential for robotic-assisted spine surgery to focus not only on screw accuracy but also on the development of novel robotic-assisted techniques.

4.
Cureus ; 15(6): e40451, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37456478

RESUMO

Background Preoperative and postoperative nutritional statuses are reported to influence the outcomes and complications of multidisciplinary treatment, including patient survival. However, a causal relationship between nutritional status and survival following spinal surgery has not been demonstrated in patients with metastatic spinal tumors. The present study was, therefore, designed to evaluate the correlation between the nutritional status and survival following spinal surgery in patients with metastatic spinal tumors. Methods Nutritional status was evaluated using the Japanese version of the modified Glasgow prognostic score (JmGPS), C-reactive protein-to-albumin ratio (CAR), prognostic nutrition index (PNI), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR), which were calculated from the results of preoperative laboratory tests. The survival period was defined as the interval between the day preoperative data were obtained and the day of death. Results Data from 57 of 113 consecutive surgeries were retrieved. The CAR, JmGPS, and PNI were significantly correlated with the survival period (CAR, r = -0.576, P < 0.01; JmGPS, r = -0.537, P < 0.01; PNI, r = 0.316, P = 0.02). Furthermore, patients with 0 points on the JmGPS had significantly longer survival. Using receiver operating characteristic curves, CAR cutoffs of ≥0.880 and ≤0.220 were found to be optimal in predicting the 90- and 180-day postoperative survival, respectively. Conclusions The findings of the present study indicate that preoperative assessment of the JmGPS, CAR, and PNI has utility in estimating nutritional status and predicting survival following spinal surgery in patients with metastatic spinal tumors.

5.
J Orthop Sci ; 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37353398

RESUMO

BACKGROUND: The present study aimed to evaluate the safety of robot-assisted screw placement in 125 cases after introducing a spinal robotics system and to identify the situations where deviation was likely to occur. METHODS: The subjects were 125 consecutive patients who underwent robotic-assisted screw placement using a spinal robotics system (Mazor X Stealth Edition, Medtronic) from April 2021 to January 2023. The 1048 screws placed with robotic assistance were evaluated. We investigated intraoperative adverse events of the robotics system and complications occurring within 30 days after surgery. We evaluated screw accuracy and deviation and compared them for vertebral levels, screw insertion methods (open traditional pedicle screw [Open-PS], cortical bone trajectory screw [CBT], percutaneous pedicle screw [PPS], and S2 alar iliac screw [S2AIS]), diagnosis, and phases of surgical cases. RESULTS: The deviation rate of robotic-assisted screw placement for spine surgery was 2.2%. Complications were reoperation due to implant-related neurological deficit in 0.8% and surgical site infection in 0.8%. There was significant difference in the deviation rate between vertebral levels. The deviation rate of the T1-T4 level was high at 10.0%. There was significant difference in the deviation rate between Open-PS, CBT, PPS, and S2AIS. The PPSs had a high deviation rate of 10.3%. The deviation rates were not significantly different between patients with and without deformity. The deviation rate did not change depending on the experience of surgical cases, and the deviation rate was favorable from the onset. CONCLUSION: Although the robotic-assisted screw placement was safe, we should be extra vigilant when placing screws in the upper thoracic region (deviation rate 10.0%) and when using PPSs (deviation rate 10.3%).

6.
Spine (Phila Pa 1976) ; 48(7): 501-506, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730533

RESUMO

STUDY DESIGN: Retrospective study. OBJECTIVE: The aim was to clarify the health-related quality of life (QOL) of patients who had adolescent idiopathic scoliosis (AIS) at a minimum of 40 years after surgery. SUMMARY OF BACKGROUND DATA: The postoperative health-related QOL of middle-aged patients with AIS has been reported to be good, but that of middle-aged and older patients with AIS has yet to be completely explored. MATERIALS AND METHODS: We included 179 patients with AIS who underwent spinal fusion(s) between 1968 and 1982. We conducted three surveys in 2009, 2014, and 2022. Patients self-administered both the Scoliosis Research Society-22 and the Roland-Morris Disability questionnaires three times (in 2009, 2014, and 2022) and the Oswestry Disability Index (ODI) questionnaire was self-administered in 2014 and 2022. We considered patients who responded to all three surveys in 2009, 2014, and 2022. RESULTS: For the Scoliosis Research Society-22 questionnaires, no significant differences were detected among the three time points (2009, 2014, and 2022) for total scores, function domain, pain domain, self-image domain, mental domain, or satisfaction domain. The results of the Roland-Morris Disability Questionnaire were also not significantly different among the surveys over time. The ODI questionnaires revealed a significant worsening of the 2022 results compared with the 2014 results. Eight patients (29.6%) who had an ODI deterioration of 10% or more had numerically fewer mobile lumbar disks than those with <10% deterioration of the ODI, although the difference did not reach statistical significance. CONCLUSION: Among patients with AIS who underwent spinal fusion(s) between 1968 and 1982, we found health-related QOL to be maintained over the last 13 years. Relatively good QOL was appreciated in this population of patients who are now middle-aged and older.


Assuntos
Cifose , Escoliose , Fusão Vertebral , Pessoa de Meia-Idade , Humanos , Adolescente , Idoso , Escoliose/epidemiologia , Estudos Retrospectivos , Qualidade de Vida , Cifose/cirurgia , Dor , Inquéritos e Questionários , Resultado do Tratamento , Fusão Vertebral/métodos
7.
IJU Case Rep ; 6(1): 22-25, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36605688

RESUMO

Introduction: We report a case of abdominal compartment syndrome due to hydroperitoneum after endoscopic combined intrarenal surgery. Case presentation: A 56-year-old woman with a left staghorn calculus underwent endoscopic combined intrarenal surgery as a two-staged procedure and developed a distended abdomen, cyanosis of both legs, and hypotension immediately after the second operation. A computed tomography scan showed hydroperitoneum. We performed urgent laparotomy and evacuated approximately 2 L of nearly transparent fluid. No peritoneal injury was detected. Postoperatively, she required intensive care for shocked liver and acute kidney injury. Conclusion: Hydroperitoneum after endoscopic combined intrarenal surgery is a rare complication and may lead to abdominal compartment syndrome or a condition where intra-abdominal pressure exceeds 20 mmHg, causing impaired organ perfusion. Delayed drainage can be fatal.

8.
Eur Spine J ; 32(2): 651-658, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36567341

RESUMO

PURPOSE: To compare the accuracy of pedicle screw placement in adolescent idiopathic scoliosis (AIS) between robotics and navigation and clarify the factors that cause screw deviation when robotics is used. METHODS: Fifty consecutive patients who underwent posterior spinal fusions with computer-assisted pedicle screw placement including robotics and navigation for AIS were included. A total of 741 pedicle screws (250: Robot group, 491: Navi group) were evaluated on postoperative CT images. A rate of penetration of ≥ 2 mm was calculated as the deviation rate. After propensity score matching, we examined vertebral levels, the distance from the reference frame (RF), and the pedicle channel grade as factors for deviation. RESULTS: The deviation rate was significantly lower in the Robot group than in the Navi group (Robot group: 1.6%, Navi group: 7.5%). After propensity score matching, 22 cases were extracted. At T5-T8, the deviation rate of the Robot group was significantly lower than that of the Navi group. In the Robot group, the T2-T4 deviation rate was significantly higher than at the other vertebral levels. The distance from the RF didn't affect the deviation rate. The deviation rate of pedicle channel Grade 4 (inner diameter of less than 1 mm) was significantly higher than for the other grades. CONCLUSION: The deviation rate of robotics was 1.6%, lower than that of navigation. The narrow pedicles with an inner diameter of less than 1 mm (deviation rate: 22.2%) and the upper thoracic level (deviation rate: 14.3%) were factors related to screw deviation even when using robotics.


Assuntos
Parafusos Pediculares , Robótica , Escoliose , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Adolescente , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Cirurgia Assistida por Computador/métodos , Fusão Vertebral/métodos , Computadores , Estudos Retrospectivos
9.
J Orthop Sci ; 28(5): 961-965, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35864030

RESUMO

BACKGROUND: The purpose of this study was to verify whether a spine robotic system was useful for junior surgeons. METHODS: Twenty-seven patients underwent posterior spinal fusion with open surgery using a spine robotic system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland) from April to August 2021. Pedicle screw insertions were performed by five surgeons. The surgeon and insertion time were recorded for each pedicle screw. Two surgeons who are board-certified spine surgeons by the Japanese Society for Spine Surgery and Related Research (JSSR) were defined as the expert surgeon group. Three surgeons who were training to acquire qualifications as JSSR board certified spine surgeons were defined as the junior surgeon group. In postoperative CT images, the deviation of 255 pedicle screws was evaluated using the Gertzbein-Robbins (GR) grades. RESULTS: In the expert surgeon group, the GR grades were Grade A for 79 screws (90.8%), Grade B for 6 (6.9%), Grade C for 2 (2.3%), and 0 (0%) for Grades D and E. I In the junior surgeon group, the GR grades were Grade A for 162 screws (96.4%), Grade B for 6 (3.6%), and 0 (0%) for Grades C, D, and E. There was no significant difference in the deviation rate between surgeon groups (p = 0.08). The mean insertion times were 174.5 ± 83.0 s in the expert surgeon group and 191.0 ± 111.0 s in the junior surgeon group. There was no significant difference in the insertion time between surgeon groups (p = 0.22). CONCLUSIONS: There were no significant differences in the deviation rate and the insertion time of robotic-assisted pedicle screw placement between expert surgeons and junior surgeons who were training to acquire qualifications as JSSR board certified spine surgeons. Robotic-assisted pedicle screw placement can be effectively employed by junior surgeons.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Cirurgiões , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Fusão Vertebral/métodos
10.
Global Spine J ; 13(5): 1319-1324, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34325544

RESUMO

STUDY DESIGN: Multicenter retrospective study. OBJECTIVES: To investigate adverse events (AEs) in patients with neuropathic pain related to lumbar disease who switched to mirogabalin from pregabalin. METHODS: This study surveyed the records of 82 patients with peripheral neuropathic leg pain related to lumbar disease who switched to mirogabalin from pregabalin. We evaluated AEs associated with pregabalin and mirogabalin, the continuation rate of mirogabalin, and the pain-relieving effect at 4 weeks after switching from pregabalin to mirogabalin. We compared patients who switched due to lack of efficacy (LoE group) and patients who switched due to AEs (AE group). RESULTS: The incidence rates of somnolence and dizziness with pregabalin were 12.2% and 14.6%, respectively, while the incidence rates with mirogabalin were reduced to 7.3% for somnolence and 4.9% for dizziness. The incidence of AEs with pregabalin was significantly higher in the AE group (LoE group: 11.1%, AE group 100%), especially for somnolence (LoE group: 3.2%, AE group: 47.1%) and dizziness (LoE group: 4.8%, AE: 52.9%). After switching, the incidences of AEs with mirogabalin were not significantly different between the 2 groups (LoE group: 15.9%, AE group: 23.5%), including for somnolence (LoE group: 7.9%, AE group: 5.9%) and dizziness (LoE group: 4.8%, AE group: 5.9%). There were no significant differences in continuation rate of mirogabalin or the pain-relieving effect between groups. CONCLUSIONS: The patients who experience somnolence and dizziness with pregabalin might be able to continue safely receiving treatment for their pain by switching to mirogabalin.

11.
Eur J Orthop Surg Traumatol ; 33(5): 1805-1810, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35976573

RESUMO

PURPOSE: To verify whether robotics was useful for surgeons who had less experience with spinal deformity surgery. METHODS: A retrospective review was conducted of 70 consecutive patients who underwent robotic-assisted pedicle screw placements with open procedures using a spine robotic system (Mazor X Stealth Edition) at a single institution from April 2021 to April 2022. Gertzbein-Robbins grades were used to assess the deviation of the 599 pedicle screws in the postoperative CT images. The rate of Grade A was considered the perfect accuracy rate, and the rate of Grades C, D, and E was calculated as the deviation rate. The perfect accuracy rate and deviation rate were compared between the spinal deformity and the non-deformity groups. The perfect accuracy rate, deviation rate, and screw insertion time were compared in the spinal deformity cases between the expert surgeon group and the less-experienced surgeon group. RESULTS: The deviation rate of the spinal deformity group was higher than that of the non-deformity group even though there was no statistically significant difference (spinal deformity group: 2.3%, non-deformity group: 1.2%, p = 0.350). In the spinal deformity cases, there was no significant difference in the perfect accuracy rate between the expert surgeon group and the less-experienced surgeon group, but the deviation rate was significantly lower in the less-experienced surgeon group (expert surgeon group: 5.0%, less-experienced surgeon group: 0%, p = 0.008). The screw insertion time was significantly shorter in the less-experienced surgeon group. CONCLUSION: Robotics is particularly useful for surgeons with less experience in spinal deformity surgery.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Cirurgiões , Cirurgia Assistida por Computador , Humanos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Estudos Retrospectivos , Fusão Vertebral/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Vértebras Lombares/cirurgia
12.
Spine Surg Relat Res ; 6(6): 589-595, 2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36561165

RESUMO

Introduction: The purpose of this study was to clarify how many cases surgeons need to experience to pass the learning phase of robotic-assisted spine surgery using the cumulative sum (CUSUM) analysis. Methods: A retrospective review was conducted on the initial 50 consecutive patients who underwent robotic-assisted pedicle screw placements with open procedures using a spine robotic system (Mazor X Stealth Edition) at a single center from April 2021 to January 2022. There were 19 male and 31 female patients with a mean age of 58.7 (range, 13-86) years. To split the surgeries into the early and late phases using the CUSUM analysis of screw insertion time, we compared the screw insertion time, the robot setting time, the registration time, and the operation time in the early and late phases. Results: The screw insertion time, the robot setting time, and the registration time declined as the number of surgical cases increased. The operation time did not decline as the number of surgical cases increased. The learning curve for screw insertion time can be separated into two stages based on the CUSUM analysis. The first 23 cases were in the early phase, and the later 27 cases were in the late phase. The mean screw insertion time was reduced from 3.2 min in the first 23 cases to 2.7 min in the subsequent 27 cases. The robot setting time and registration time in the late phase were also significantly shorter than those in the early phase. Conclusions: The screw insertion time, robot setting time, and registration time decreased with experience. After 23 cases, surgeons passed the learning phase of robotic-assisted spine surgery and became more proficient.

13.
Spine Surg Relat Res ; 6(5): 443-447, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36348673

RESUMO

Introduction: The alpha-defensin lateral flow test has been used in periprosthetic joint infection as a diagnostic support tool because of its simplicity and speed. However, the test has not been used to diagnose spinal infections. The purpose of this study was to investigate the efficacy of the alpha-defensin lateral flow test for diagnosing spinal infections. Methods: The subjects were 11 patients who were suspected of having spinal infections from October 2019 to August 2021 and underwent biopsies at a single institution. There were nine male and two female patients, with an average age of 60.7 (14-87) years. For diagnosing infection, the patient's consent for biopsy was obtained, and the sample was collected by computed tomography-guided aspiration biopsy or open biopsy at the site considered to be a possible abscess. The samples were subjected to a bacterial culture test, an acid-fast bacillus culture test, and an alpha-defensin lateral flow test (SynovasureⓇ lateral flow test; Zimmer Biomet, IN, USA). Results: Of the 11 suspected spinal infections, the alpha-defensin lateral flow test was positive in 8 cases, negative in 2 cases, and undeterminable in 1 case. Of the 10 cases excluding the undeterminable case, the definitive diagnosis was 9 cases of spinal infection (spondylitis: 6 cases, spinal implant infection: 3 cases) and 1 case of vertebral body fracture. The alpha-defensin lateral flow test demonstrated a sensitivity of 88.9%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 50%. The biopsy sample culture test demonstrated a sensitivity of 77.8%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 33.3%. Conclusions: We suggested that the alpha-defensin lateral flow test might be useful as a diagnostic support tool for spinal infections.

14.
Cureus ; 14(5): e25039, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35719818

RESUMO

Introduction The purpose of this study was to clarify the superiority of robotic-assisted lumbar pedicle screw placement in terms of screw insertion time, fluoroscopy time, and operation time. Methods The subjects were 46 patients who underwent a posterior lumbar interbody fusion with an open procedure for lumbar degenerative disease from April 2021 to February 2022. The robot group contained 29 cases of screw insertion using a spine robotic system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The freehand group contained 17 cases of screw insertion with the freehand technique utilizing the conventional C-arm image guidance. The screw insertion time, fluoroscopy time, and operation time were compared between the robot and the freehand group. Results The screw insertion time did not differ significantly between the two groups (robot group: 179.0 ± 65.2 sec; freehand group: 164.2 ± 83.4 sec; p = 0.507). The fluoroscopy time was significantly shorter in the robot group (robot group: 28.3 ± 25.8 sec; freehand group: 67.5 ± 72.8 sec; p = 0.011). The fluoroscopy time per segment was also significantly shorter in the robot group (robot group: 17.8 ± 23.0 sec; freehand group: 60.2 ± 74.8 sec; p = 0.007). The operation time was significantly longer in the robot group (robot group: 249.6 ± 72.5 min; freehand group: 195.8 ± 60.1 sec; p = 0.013), but the operation time per segment did not differ significantly between the two groups (robot group: 144.1 ± 39.0 min; freehand group: 159.7 ± 34.4 min; p = 0.477). Conclusions The screw insertion time and operation time per segment were similar when employing the spine robotic system compared to the freehand technique; however, the fluoroscopy time was shorter. The fluoroscopy time per segment in the robot group was 29.6% of the time of the freehand group using the C-arm. The surgeon's radiation exposure is thought to be decreased since the spine robotic system shortens the fluoroscopy time.

15.
IDCases ; 27: e01410, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35106284

RESUMO

Streptococcus salivarius (S. salivarius) is an oral commensal bacterium that rarely causes disease. Here, we report a case of emphysematous cystitis due to S. salivarius infection in a patient with a neurogenic bladder. A 56-year-old woman was hospitalized and managed for left putamen hemorrhage. Afterward, she developed poor oral intake. Although the patient was afebrile, laboratory test results suggested an inflammatory response. Urinalysis revealed pyuria and hematuria. Abdominal computed tomography revealed a thickened urinary bladder wall and intraluminal gas. Additionally, she was diagnosed with a neurogenic bladder as she had approximately 200 mL of residual urine. The patient was diagnosed with emphysematous cystitis, and S. salivarius was isolated from urine culture specimens. The patient's condition improved immediately after treatment, which included bladder drainage and administration of appropriate antibiotics. We could not find any report on S. salivarius causing urinary tract infections, such as emphysematous cystitis. Accordingly, we report this case along with a review of the literature.

16.
IJU Case Rep ; 5(1): 19-22, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35005462

RESUMO

INTRODUCTION: We report a rare case of an extramedullary plasmacytoma of the ureter. CASE PRESENTATION: A 77-year-old man was referred to our hospital because of left hydronephrosis. Computed tomography showed a tumor in the left ureter, and tumor invasion into the periureteric fat was suspected. Urine cytology showed Eatypical cells whose nuclei were hyperchromatic (class IIIb). The left ureteral tumor was diagnosed as urothelial carcinoma (cT3N0M0) preoperatively. Subsequently, we performed laparoscopic radical nephroureterectomy with bladder cuff excision. The tumor was pathologically diagnosed as a plasmacytoma. Postoperative positron emission tomography did not reveal abnormal uptake, and bone marrow aspiration findings were normal. Consequently, the left ureter tumor was diagnosed as an extramedullary plasmacytoma of the ureter. CONCLUSION: Extramedullary plasmacytoma commonly occurs in the upper respiratory tract or upper gastrointestinal tract. Extramedullary plasmacytoma of the ureter is rare. This is only the fourth reported case of extramedullary plasmacytoma of the ureter.

17.
Cureus ; 14(12): e32574, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36654567

RESUMO

Introduction The purpose of this study was to evaluate robotic-assisted cortical bone trajectory (CBT) screw placement. Early, middle, and late phases of robotic-assisted CBT screw placement were compared for accuracy and screw insertion time by comparing time and accuracy in every phase.  Methods A retrospective review was conducted on the initial 40 patients who underwent spinal fusion using CBT screws in one institution from September 2021 to September 2022 utilizing a spine surgery robot system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The inclusion criterion was one- or two-level posterior lumbar interbody fusion (PLIF). Exclusion criteria were 1) patients who underwent posterior-lateral fusion in other segments, 2) patients who underwent additional decompression in other segments, 3) patients who underwent reoperation, and 4) patients with spondylolysis. The deviation of the CBT screw was evaluated on computed tomography (CT) one week after surgery using the Gertzbein-Robbins grade system. The rate of Grade A was considered the perfect accuracy rate, and the rate of penetration of 2 mm or more (Grades C, D, and E) was calculated as the deviation rate. To assess the learning curve, patients were divided into three groups. The first 10 cases were in the early phase group, the subsequent 10 cases were in the middle phase group, and the last 10 cases were in the late phase group. We compared the perfect accuracy rate, deviation rate, operative time, operative time per segment, intraoperative blood loss, registration time, and screw insertion time among the three groups. Results Thirty patients met the criteria. Overall, the perfect accuracy (Grade A) rate of the screw was 95.3% and the deviation rate was 1.4%. The perfect accuracy rate was 90.4% in the early phase, 95.5% in the middle phase, and 100% in the late phase. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase, and there was no statistically significant difference between the three groups. Among the three groups, the operative time, the operative time per segment, the intraoperative blood loss, and the registration time were not significantly different. There was no significant difference in the screw insertion time among the three groups, but it decreased with experience (early phase: 156.9 ± 54.7 sec, middle phase: 139.9 ± 41.6 sec, and late phase: 106.4 ± 39.9 sec, p=0.060). The screw insertion time of the late phase tended to be shorter than that of the early phase (p=0.052). Conclusions The deviation rate of robotic-assisted CBT screw placement with one- or two-level PLIF was 1.4%, which was highly accurate. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase. Although the deviation rate was low even in the early period, the screw insertion time in the early 10 cases tended to be longer than that in the late 10 cases. After passing the experience of 10 cases, this study concluded that robotic-assisted CBT screw placement was proficient.

18.
Ther Adv Med Oncol ; 13: 17588359211053420, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34707694

RESUMO

Driver mutations in lung cancer have been generally considered mutually exclusive; however, multiple gene screenings have recently become mainstream. Therefore, it is not uncommon to identify two or more mutations at first diagnosis, making it difficult to determine which tyrosine kinase inhibitor to administer. A 69-year-old woman complaining of back pain was diagnosed with adenocarcinoma T4N3M1c, stage IVB. Although PCR mutation test detected exon21 L858R point mutation by bronchoscopic sample, the therapeutic effect of afatinib was poor. Subsequently, next-generation sequencing (NGS) panel test of a metastasized bone specimen confirmed BRAF V600E. Furthermore, high sensitivity NGS panel system found the gene mutation allele frequency was higher for BRAF V600E than EGFR exon21 L858R for both primary lung tissue and the metastasized specimen. Subsequent BRAF/MEK inhibitor administration showed a remarkable treatment effect. When two or more driver mutations are detected in lung cancer, confirming the allelic frequency of the mutant gene might be useful in selecting more effective agents for front-line treatment.

19.
Cureus ; 13(6): e15488, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34262824

RESUMO

Introduction There are few published studies on posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS) that have reported that the stored amounts of autologous blood donation (ABD) needed for the procedure were estimated by taking into account total blood loss (TBL). The aim of this study was to clarify the following clinical questions: (1) Does the use of tranexamic acid (TXA) reduce the TBL during PSF for AIS? (2) What volume of ABD should be stored to avoid allogeneic blood transfusions? Methods This study investigated 44 female patients who underwent PSF for AIS. A total of 33 patients underwent PSF without TXA (non-TXA group) and 11 patients underwent PSF with TXA (TXA group). TBL was determined by the hemoglobin (Hb) balance method calculated with circulating blood volume, Hb levels, hematocrit (Ht) levels before and three days after surgery, and the volumes of blood transfusions, including stored ABD. For the TXA patients, TBL was used to determine the appropriate amount of stored ABD and the number of ABD collections. Results The amount of TBL was lower in the TXA group compared to the non-TXA group. The mean required volume of stored ABD in the TXA group was 218.2 ± 577.3 mL, with a required maximum volume of 699.0 mL. The proportions of patients requiring allogeneic blood transfusion were as follows: 72.7% for those with no ABD collection, 45.5% for one ABD collection, and 0% for two ABD collections when TXA was used during surgery.  Conclusions TXA reduced the TBL of patients undergoing PSF for AIS. The maximum amount of stored ABD needed was 699.0 mL. Allogeneic blood transfusion can be avoided by storing two ABD collections when TXA is used during the surgery.

20.
Spine Surg Relat Res ; 5(2): 81-85, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33842714

RESUMO

INTRODUCTION: The revised Tokuhashi scoring system has been used to predict survival in patients with metastatic spinal tumors. Because of the rapid progress of cancer therapy, the original criteria of the revised Tokuhashi scoring system became in recent years unsuitable. The study aim was to evaluate the validity of the revised Tokuhashi scoring system in patients who underwent spinal surgery and to establish new prognostic criteria. METHODS: The study enrolled 85 patients with metastatic spinal tumors who underwent spinal surgery. The patients' survival outcomes in October 2019 were as follows: 57 patients died; 10 were alive; and 18 had unknown prognoses. The study evaluated the validity of the Tokuhashi scoring system, and established and validated the new prognostic criteria. RESULTS: The accuracies of the Tokuhashi scoring system were 66.7% in the short-term group, 60% in the midterm group, and 100% in the long-term group. Among the patients who died, the survival period and total score were significantly correlated. Total score cutoff point was six points in the patients whose predicted survival was <6 months. Total score cutoff point was eight points in the patients whose predicted survival was ≥1 year. CONCLUSIONS: As the prognosis of patients has improved in recent years, the original criteria of the revised Tokuhashi scoring system have been questioned as to their suitability to current treatments. Especially, the survival period among the patients with total scores of 7 and 8 points was not accurate. According to this study, the new prognostic criteria of the revised Tokuhashi scoring system were set to 0 to 6 points for the short-term group, 7 points for the midterm group, and 8 to 15 points for the long-term group.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...