Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2021: 6638588, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33954189

RESUMO

Magnetic Resonance Imaging (MRI) is an important yet slow medical imaging modality. Compressed sensing (CS) theory has enabled to accelerate the MRI acquisition process using some nonlinear reconstruction techniques from even 10% of the Nyquist samples. In recent years, interpolated compressed sensing (iCS) has further reduced the scan time, as compared to CS, by exploiting the strong interslice correlation of multislice MRI. In this paper, an improved efficient interpolated compressed sensing (EiCS) technique is proposed using radial undersampling schemes. The proposed efficient interpolation technique uses three consecutive slices to estimate the missing samples of the central target slice from its two neighboring slices. Seven different evaluation metrics are used to analyze the performance of the proposed technique such as structural similarity index measurement (SSIM), feature similarity index measurement (FSIM), mean square error (MSE), peak signal to noise ratio (PSNR), correlation (CORR), sharpness index (SI), and perceptual image quality evaluator (PIQE) and compared with the latest interpolation techniques. The simulation results show that the proposed EiCS technique has improved image quality and performance using both golden angle and uniform angle radial sampling patterns, with an even lower sampling ratio and maximum information content and using a more practical sampling scheme.


Assuntos
Algoritmos , Compressão de Dados , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos
2.
Sensors (Basel) ; 19(8)2019 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-31018597

RESUMO

The application of compressed sensing (CS) to biomedical imaging is sensational since it permits a rationally accurate reconstruction of images by exploiting the image sparsity. The quality of CS reconstruction methods largely depends on the use of various sparsifying transforms, such as wavelets, curvelets or total variation (TV), to recover MR images. As per recently developed mathematical concepts of CS, the biomedical images with sparse representation can be recovered from randomly undersampled data, provided that an appropriate nonlinear recovery method is used. Due to high under-sampling, the reconstructed images have noise like artifacts because of aliasing. Reconstruction of images from CS involves two steps, one for dictionary learning and the other for sparse coding. In this novel framework, we choose Simultaneous code word optimization (SimCO) patch-based dictionary learning that updates the atoms simultaneously, whereas Focal underdetermined system solver (FOCUSS) is used for sparse representation because of a soft constraint on sparsity of an image. Combining SimCO and FOCUSS, we propose a new scheme called SiFo. Our proposed alternating reconstruction scheme learns the dictionary, uses it to eliminate aliasing and noise in one stage, and afterwards restores and fills in the k-space data in the second stage. Experiments were performed using different sampling schemes with noisy and noiseless cases of both phantom and real brain images. Based on various performance parameters, it has been shown that our designed technique outperforms the conventional techniques, like K-SVD with OMP, used in dictionary learning based MRI (DLMRI) reconstruction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA