Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zentralbl Chir ; 132(3): 220-5; discussion 225-6, 2007 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-17610193

RESUMO

INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.


Assuntos
Angioplastia , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Aneurisma Ilíaco/cirurgia , Transplante de Rim , Complicações Pós-Operatórias/cirurgia , Stents , Transplante Heterotópico , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Comorbidade , Embolização Terapêutica , Seguimentos , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA