Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NMC Case Rep J ; 6(4): 117-120, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31592152

RESUMO

A 63-year-old man was admitted in our hospital with the chief complaint of upper limb numbness 3 years after undergoing spinous process-splitting laminoplasty (C3-C7) in another hospital. The hydroxyapatite spacers used for the laminoplasty had dislocated, resulting sensory disorders of the upper extremities. Additionally, loosened hydroxyapatite intraspinous spacers and syringomyelia were confirmed. A revision operation was performed, during which the C5 spacer was observed to have dislodged into the spinal canal, and a dural membrane defect, arachnoid membrane tear, cerebrospinal fluid leakage, and marked adhesion change were observed. The adhesion was exfoliated as far as possible; moreover, to prevent the reflux of syringomyelia, a syrinx-subarachnoid shunt (SS shunt) was placed. Although there was concern of further adhesion by putting foreign matter, SS shunt indwelling was chosen to obtain sure disappearance of syringomyelia. The postoperative course was uneventful. A gradual improvement in the upper limb numbness was observed without a recurrence of syringomyelia at 9 years of follow-up.

3.
Neurol Med Chir (Tokyo) ; 49(11): 501-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19940397

RESUMO

Vertebroplasty with hydroxyapatite blocks through a modified percutaneous approach was used to treat 30 patients with vertebral body fractures in 32 vertebral bodies between February 2003 and March 2007. The mean follow-up period was 16.6 months. The pain associated with this procedure, effects on adjacent vertebral bodies, and other complications were evaluated. The rate of recollapse after vertebroplasty was examined in 26 patients with 26 vertebral bodies treated and followed up for more than 3 months. Mean time of operation was 57 minutes and mean number of blocks used per vertebral body was 104. The mean visual analogue scale score was 7.0 preoperatively and 1.6 postoperatively. The mean decline in postoperative vertebral body height was 13%. New vertebral body fractures occurred postoperatively in 3 vertebral bodies in 2 patients. Leakage of blocks outside the vertebral body occurred in 2 patients during the operation, and after the operation in one patient, and the hydroxyapatite plug broke postoperatively in one patient. Hydroxyapatite blocks yielded good pain relief comparable to bone cement, with no serious complications such as a pulmonary embolism or leakage into the spinal canal, and are effective for percutaneous vertebroplasty.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Durapatita/uso terapêutico , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Coluna Vertebral/cirurgia , Coluna Vertebral/cirurgia , Vertebroplastia/métodos , Idoso , Idoso de 80 Anos ou mais , Dor nas Costas/diagnóstico por imagem , Dor nas Costas/patologia , Dor nas Costas/cirurgia , Materiais Biocompatíveis/efeitos adversos , Durapatita/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Feminino , Migração de Corpo Estranho/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Dor Pós-Operatória/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Embolia Pulmonar/epidemiologia , Radiografia , Recidiva , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/patologia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/patologia , Resultado do Tratamento , Vertebroplastia/efeitos adversos , Vertebroplastia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA