1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(4): 354-364, 2024 Apr 20.
Artigo em Japonês | MEDLINE | ID: mdl-38325850

RESUMO

PURPOSE: Radiography training for students in colleges of radiology should be based on real clinical situations. The purpose of this study was to verify the clinical validity of our originally developed scenarios for chest X-ray training and the instructional contents using gaze information of experienced radiology technologists (RTs). METHODS: We divided 8 RTs with different experiences into an evaluator group (3 RTs) and a subject group (5 RTs). The evaluator group created a validation model consisting of 31 items, a chest X-ray scenario, instructional contents, and gaze attention objects during the scenario. The subject group simulated chest X-ray wearing an eye tracker. The evaluator group evaluated fit rates of the validation model to subjects' procedures based on gaze information to verify the clinical validity of the validation model. RESULTS: The subject group procedures did not deviate from the scenario. We obtained a fit rate of 91.6±6.70%. CONCLUSION: Our validation model showed more than 90% fitting with the chest X-ray techniques of five RTs with different backgrounds. This result suggested that the scenario and instructional contents in this study had clinical validity.


Assuntos
Radiografia Torácica , Tecnologia Radiológica , Humanos , Tecnologia Radiológica/educação , Masculino , Radiologia/educação , Feminino
2.
Radiat Prot Dosimetry ; 199(19): 2391-2395, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37609988

RESUMO

In recent years, radiochromic films have begun to be used for dosimetry in mammography; however, the most sensitive GAFCHROMIC XR-QA2 (XR-QA2) film is no longer available owing to its discontinuation. In this study, we evaluated the sensitivity characteristics of GAFCHROMIC LD-V1 (LD-V1) as an alternative to XR-QA2 in the field of mammography, at a low dose and low energy. Our results show that the average ratio of the concentration change of LD-V1 divided by the concentration change of XR-QA2 at each absorbed dose was 53.7%, indicating the sensitivity of LD-V1 to be approximately half of XR-QA2. In addition, the linearity of the concentration change is sufficient even within a dose range of 0.59-14.52 mGy, which is lower than the manufacturer's recommended dose range. Therefore, the LD-V1 is capable of accurate dose assessment even with a low dose and the low level of energy used in mammography.


Assuntos
Dosimetria Fotográfica , Radiometria , Doses de Radiação , Dosimetria Fotográfica/métodos , Calibragem , Mamografia
3.
Radiat Prot Dosimetry ; 199(8-9): 1007-1011, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225196

RESUMO

Mammography is one of the most effective diagnostic methods for the early detection of breast cancer; however, it poses the risk of radiation exposure. To date, mammography dosimetry has been performed according to the mean glandular dose; however, the actual exposure in the breast has not been assessed. Here, we have measured dose distributions and depth doses using both radiochromic films and mammographic phantoms, and a three-dimensional intra-mammary dose assessment was conducted. The absorbed dose distribution at the surface was markedly higher on the chest wall side but lower on the nipple side. The absorbed doses in the depth direction exponentially decreased. The glandular tissue near the surface may be irradiated with an absorbed dose of 7.0 mGy or higher. Since LD-V1 could be placed inside the phantom, the absorbed dose inside the breast could also be evaluated in three dimensions.


Assuntos
Mamografia , Exposição à Radiação , Radiometria , Tórax , Imagens de Fantasmas
4.
Radiat Prot Dosimetry ; 199(8-9): 1002-1006, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225197

RESUMO

The effects of lead equivalent and lens area of radiation-protective eyewear on lens exposure control were examined. The simulated patient underwent 10-min X-ray fluoroscopy, and the lens dose of the simulated surgeon wearing radiation protection glasses was measured using lens dosemeters attached to the corner of the eye and eyeball. In total, 10 types of radiation protection glasses were selected for measurement. Correlation analysis of the equivalent dose in the lens of the eye with lead equivalence and lens area was performed. The equivalent dose in the lens of the eye of the corner of the eye was negatively correlated with the area of the lens. The equivalent dose in the lens of the eye and the eyeball showed a strong negative correlation with lead equivalence. Lens dosemeters worn at the corner of the eye may overestimate the equivalent dose in the lens of the eye. Moreover, the reduction in exposure of the lens was significantly influenced by the lead equivalent.


Assuntos
Cristalino , Proteção Radiológica , Cirurgiões , Humanos , Olho
5.
Bone Joint Res ; 12(3): 179-188, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-37051813

RESUMO

Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers' websites. We initially identified 4,402 clinical trials, 27 of which were eligible for inclusion and analysis, including nine shoulder surgery trials, eight knee surgery trials, two ankle surgery trials, two hand surgery trials, and six peripheral nerve graft trials. Nine of the trials were completed. We identified only one product that will be commercially available for use in knee surgery with significant mechanical load resistance. Peracetic acid and gamma irradiation were frequently used for sterilization. Despite the demand for decellularized tissue, few decellularized tissue products are currently commercially available, particularly for the knee joint. To be viable in orthopaedic surgery, decellularized tissue must exhibit biocompatibility and mechanical strength, and these requirements are challenging for the clinical application of decellularized tissue. However, the variety of available decellularized products has recently increased. Therefore, decellularized grafts may become a promising option in orthopaedic surgery.

6.
Radiat Prot Dosimetry ; 196(3-4): 226-233, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34668552

RESUMO

This study developed a phantom with a shape similar to that of the breast and use GAFCHROMIC films that can be placed inside the phantom to measure the detailed breast dose distribution in mammography. GAFCHROMIC EBT3 was placed on the block cube breast phantom and irradiated with a mammography device to measure the absorbed dose distribution inside the phantom in the horizontal and depth directions. The dose distribution in the horizontal plane was the highest in the centre on the chest wall side, and it decreased in a fan shape. Along the depth of the phantom, the doses absorbed across the entire cross-section were 16.15 mGy at the surface and 7.51, 3.25 and 1.68 mGy at depths of 10, 20 and 30 mm, respectively. Compared with the mean glandular dose, the proposed method can measure breast dose distributions in greater detail and is applicable to various breast shapes.


Assuntos
Dosimetria Fotográfica , Radiometria , Mama/diagnóstico por imagem , Mamografia , Imagens de Fantasmas
7.
J Radiol Prot ; 41(3)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34102616

RESUMO

Increased x-ray exposure to physicians' eye lenses during radiology procedures is a significant concern. In this study, x-ray exposure to the eye was measured using an anthropomorphic head phantom, with and without radiation-protective devices, to examine the dose of x-ray radiation that physicians are exposed to during endoscopic retrograde cholangiopancreatography (ERCP). X-ray exposure of the eye was measured using novel dedicated direct eye lens dosimeters that could specifically measureHp(3) during the ERCP procedure. The spatial dose in the height direction of the physician was measured using an ionization chamber dosimeter. Eye dosimeters were attached inside and outside the lead (Pb) glasses attached to the head of the human phantom to demonstrate its protective effect. Irradiation from the system lasted for 30 min. When the overcouch x-ray tube system is used, the cumulative radiation dose over the 30 min x-ray fluoroscopy time, without the use of radiation-protective devices, to the left and right eyes was 3.7 and 1.5 mSv, respectively. This dose was estimated to be the dose to the lens per therapeutic ERCP examination. With radiation-protective glasses, the dose reduced to 1.8 and 1.0 mSv for the left and right eye, respectively. The results of our study indicated that radiation exposure to the eye was reduced by up to 80.0% using Pb glasses and by 96.8% using radiation-protective curtains. Our study indicates that a physician's maximum radiation exposure to the eyes during an ERCP procedure may be above the level recommended by the International Commission on Radiological Protection when the physician does not use radiation-protective devices. The eyewear, which is larger and fitted more closely to the face, provided a better protection effect even with a low lead equivalence, demonstrating that the shape of eyewear is important for protective function.


Assuntos
Cristalino , Exposição Ocupacional , Colangiopancreatografia Retrógrada Endoscópica , Olho , Dispositivos de Proteção dos Olhos , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação
8.
Radiat Prot Dosimetry ; 193(2): 96-104, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33786601

RESUMO

In this paper, we propose a novel radiochromic film (RCF)-based computed tomography (CT) dosimetry method, which is different from the method based on CT dose index. RCF dosimetry using Gafchromic QA2 films was performed using two lengths of film-folding phantoms. The phantom was exposed to X-ray CT through a single scan, while the RCF was sandwiched between the phantoms. We analysed the dose profile curve in two directions to investigate the dose distribution. We observed a difference in the dose distribution as the phantom size changed. Our results contradict with the results of previous studies such as Monte Carlo simulation or direct measurement. The ability to visually evaluate 2D dose distributions is an advantage of RCF dosimetry over other methods. This research investigated the ability of 2D X-ray CT dose evaluation using RCF and film-folding phantom.


Assuntos
Dosimetria Fotográfica , Tomografia Computadorizada por Raios X , Método de Monte Carlo , Imagens de Fantasmas , Filme para Raios X , Raios X
9.
Open Med (Wars) ; 13: 394-401, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30234160

RESUMO

Performing accurate diagnosis using computed tomography (CT) in emergency medicine may reduce mortality rates in various diseases. In this observational, correlational and cross-sectional study, we conducted multiple regression analyses to investigate the relationship between CT utilization rates and mortality. In addition, we estimated the annual net profits from CT to show the profitability of introducing a CT system in each Japanese prefecture. We conducted a multiple regression analysis to investigate correlations between CT utilization rates and mortality from each disease adjusted for the population density, number of doctors, as well as transportation time to the medical institution. The results of multiple regression analysis showed that traffic accident mortality was related to CT utilization rate and population density. Extrinsic death such as mortality due to falling, drowning and asphyxia was related to CT utilization, indicating that CT in emergency medicine reduced mortality. Moreover, the annual net profit from multi-slice CT (MSCT) was estimated as positive. Our study clearly demonstrates that CT utilization rates relate to a reduction in mortality from accidents, indicating that screening patients with CT in the emergency room has a beneficial effect and reduces mortality. Therefore, CT equipment has a beneficial effect in both emergency medicine and hospital management.

10.
Front Public Health ; 6: 380, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30687691

RESUMO

The number of computed tomography (CT) systems in operation in Japan is approximately 4.3 times higher than that of the OECD average. However, CT systems are expensive, and thus, a heavy financial burden for hospital management. We calculate the annual net profits from CT introduction in Japan for single-slice CT (SSCT), multi-slice CT (MSCT), number of hospital beds, and prefecture. We also analyze the factors that affect CT profitability. First, the annual income per CT in operation is estimated for 2011. Second, the annual costs per CT are calculated as the sum of depreciation, maintenance, and labor costs. Finally, the annual net profits per CT are estimated for SSCT and MSCT, the number of hospital beds, and prefecture. A correlation analysis between the annual net profits, population, and number of physicians per CT equipment is used to determine the determinants of the net CT profits by prefecture. Our results show that, for hospitals with fewer than 100 beds, the annual net CT profits are higher for SSCT than MSCT, and vice versa for hospitals with at least 100 beds. Both SSCT and MSCT increased profits as the number of hospital beds increased. The annual net CT profits per prefecture are USD -12,105 for SSCT and USD 87,233 for MSCT, on average. The annual net profits per prefecture and population per CT show positive correlations with both SSCT and MSCT, as do the annual net profits per prefecture and number of physicians per CT. Thus, choosing high-performance MSCT is advantageous in terms of profitability in facilities with at least 100 beds. Additionally, CT profitability presumably affects the balance between the number of introduced CTs, population per CT, and number of physicians per CT.

11.
Bioelectromagnetics ; 35(1): 70-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24115150

RESUMO

Occupational exposure to the high static magnetic fields (SMFs) during magnetic resonance imaging (MRI) examinations raises concerns of adverse health effects. In this study, personal exposure monitoring of the magnetic fields during routine examinations in two 3 T MRI systems was carried out. A three-axis Hall magnetometer was attached to a subject's chest during monitoring. Data acquisition started every time the subject entered the scanner room and ended when the subject exited the room. Four radiologic technologists from two different institutes participated in this study. The maximum exposed field ranged from 0 to 1250 mT and the average peak magnetic field (B) was 428 ± 231 mT (mean ± standard deviation (SD): number of samples (N) = 103). Then, the relationship between exposure levels and work duties was analyzed. The MRI examination of the head or neck showed the highest average peak B among four work categories. These results provide information of real exposure levels for 3 T MRI system operators and can also improve the current practical training advice for preventing extra occupational field exposure.


Assuntos
Campos Magnéticos/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Exposição Ocupacional , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Doses de Radiação , Monitoramento de Radiação