Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nucl Med Commun ; 32(10): 887-95, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21876399

RESUMO

OBJECTIVES: Radiolabelled somatostatin analogues have found wide clinical use in nuclear medicine for both diagnostic and therapeutic applications. Here, we describe the development of a fully automated synthesis system allowing radiolabelling of 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-derivatized peptides with 68Ga/¹¹¹In/¹77Lu and 9°Y, meeting radiation safety and pharmaceutical requirements. MATERIALS AND METHODS: The system consists of a syringe pump, a holder for insertion of a single use multivalve cassette, a heater and a removable radiation shielding. 68Ga labelling was performed in acetate buffer and ¹77Lu, 9°Y and ¹¹¹In labelling in ascorbate buffer, respectively, followed by purification on a C18 cartridge and final sterile filtration. Cross-contamination was prevented by using disposable cassettes and also by ensuring pharmaceutical standards. Radiochemical purity (RCP) was determined by instant thin-layer chromatography on silica gel impregnated glass fibres and reversed-phase high performance liquid chromatography. RESULTS: 68Ga-DOTA-peptides were prepared with high RCP (>91%) and radiochemical yields (RCY>80% decay corrected) and 68Ge content was less than 0.0001% in all cases. Synthesis time did not exceed 30 min. ¹¹¹In, ¹77Lu and 9°Y labelling of DOTA-peptides resulted again in high yields (approximately 90%) and RCP (approximately 95%) and total synthesis time of less than 45 min. Radiation dose to fingers was considerably reduced when compared with manual labelling procedures. CONCLUSION: The described system allows fully automated, aseptic preparation of DOTA-peptides radiolabelled with different radionuclides in high radiochemical yields and pharmaceutical quality suitable for clinical application.


Assuntos
Equipamentos Descartáveis , Marcação por Isótopo/instrumentação , Peptídeos/química , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Automação , Segurança de Equipamentos , Compostos Heterocíclicos com 1 Anel/química , Peptídeos/síntese química , Peptídeos/uso terapêutico , Radiometria , Robótica
2.
ChemSusChem ; 1(12): 993-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19034896

RESUMO

Irradiation of a palladium catalyst bearing UV-A-absorbing phosphine ligands with low-intensity UV-A light leads to higher conversions of reactants at lower temperatures and an increased selectivity towards the cross-coupling product in Suzuki-Miyaura- and Stille-type reactions. The examples studied illustrate that a selective energy input into the catalyst by irradiation leads to more selective conversions under milder reaction conditions. With the availability of affordable and energy-efficient UV-A LED light sources, selective heating of the catalyst by light can be envisaged as a general strategy to increase the performance of a catalyst.


Assuntos
Raios Ultravioleta , Catálise/efeitos da radiação , Ligantes , Paládio/química , Fosfinas/química , Especificidade por Substrato , Temperatura
3.
Chem Commun (Camb) ; (9): 1170-2, 2005 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-15726181

RESUMO

Sweet solutions are obtained upon heating mixtures of simple carbohydrates, urea and inorganic salts to moderate temperatures, to give new chiral media for organic reactions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...