Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1304: 342539, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637037

RESUMO

Three-dimensional (3D)-cultured cells have attracted the attention of researchers in tissue engineering- and drug screening-related fields. Among them, 3D cellular fibers have attracted significant attention because they can be stacked to prepare more complex tissues and organs. Cellular fibers are widely fabricated using extrusion 3D bioprinters. For these applications, it is necessary to evaluate cellular activities, such as the oxygen consumption rate (OCR), which is one of the major metabolic activities. We previously reported the use of scanning electrochemical microscopy (SECM) to evaluate the OCRs of cell spheroids. However, the SECM approach has not yet been applied to hydrogel fibers prepared using the bioprinters. To the best of our knowledge, this is the first study to evaluate the OCR of cellular fibers printed by extrusion 3D bioprinters. First, the diffusion theory was discussed to address this issue. Next, diffusion models were simulated to compare realistic models with this theory. Finally, the OCRs of MCF-7 cells in the printed hydrogel fibers were evaluated as a proof of concept. Our proposed approach could potentially be used to evaluate the OCRs of tissue-engineered fibers for organ transplantation and drug screening using in-vitro models.


Assuntos
Hidrogéis , Esferoides Celulares , Humanos , Microscopia Eletroquímica de Varredura , Células Cultivadas , Engenharia Tecidual/métodos , Consumo de Oxigênio , Impressão Tridimensional
2.
Biotechnol Bioeng ; 121(3): 1050-1059, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38131167

RESUMO

Pancreatic islet transplantation presents a promising therapy for individuals suffering from type 1 diabetes. To maintain the function of transplanted islets in vivo, it is imperative to induce angiogenesis. However, the mechanisms underlying angiogenesis triggered by islets remain unclear. In this study, we introduced a microphysiological system to study the angiogenic capacity and dynamics of individual islets. The system, which features an open-top structure, uniquely facilitates the inoculation of islets and the longitudinal observation of vascular formation in in vivo like microenvironment with islet-endothelial cell communication. By leveraging our system, we discovered notable islet-islet heterogeneity in the angiogenic capacity. Transcriptomic analysis of the vascularized islets revealed that islets with high angiogenic capacity exhibited upregulation of genes related to insulin secretion and downregulation of genes related to angiogenesis and fibroblasts. In conclusion, our microfluidic approach is effective in characterizing the vascular formation of individual islets and holds great promise for elucidating the angiogenic mechanisms that enhance islet transplantation therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas , Humanos , Microfluídica , Ilhotas Pancreáticas/metabolismo , Secreção de Insulina
3.
Anal Chem ; 95(49): 18158-18165, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-38014683

RESUMO

Vasculature-on-a-chip is a microfluidic cell culture device used for modeling vascular functions by culturing endothelial cells. Porous membranes are widely used to create cell culture environments. However, in situ real-time measurements of cellular metabolites in microchannels are challenging. In this study, a novel microfluidic device with a porous membrane electrode was developed for the in situ monitoring of nitric oxide (NO) released by endothelial cells in real time. In this system, a porous Au membrane electrode was placed directly beneath the cells for in situ and real-time measurements of NO, a biomarker of endothelial cells. First, the device was electrochemically characterized to construct a calibration plot for NO. Next, NO released by human umbilical vein endothelial cells under l-arginine stimulation was successfully quantified. Furthermore, the changes in NO release with culture time (in days) using the same sample were successfully recorded by exploiting minimally invasive measurements. This is the first report on the combination of a microfluidic device and porous membrane electrode for the electrochemical analysis of endothelial cells. This device will contribute to the development of organ-on-a-chip technology for real-time in situ cell analyses.


Assuntos
Dispositivos Lab-On-A-Chip , Óxido Nítrico , Humanos , Óxido Nítrico/metabolismo , Porosidade , Células Endoteliais da Veia Umbilical Humana/metabolismo , Eletrodos
4.
Adv Healthc Mater ; 12(31): e2302011, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37478383

RESUMO

Core-shell hydrogel fibers are widely used in cell culture applications. A simple and rapid method is presented for fabricating core-shell hydrogel fibers, consisting of straight or beaded core fibers, for cell culture applications. The core fibers are prepared using interfacial polyelectrolyte complexation (IPC) with chitosan and DNA. Briefly, two droplets of chitosan and DNA are brought in contact to form an IPC film, which is dragged to prepare an IPC fiber. The incubation time and DNA concentration are adjusted to prepare straight and beaded IPC fibers. The fibers with Ca2+ are immersed in an alginate solution to form calcium alginate shell hydrogels around the core IPC fibers. To the best of the knowledge, this is the first report of core-shell hydrogel fibers with IPC fiber cores. To demonstrate cell culture, straight hydrogel fibers are applied to fabricate hepatic models consisting of HepG2 and 3T3 fibroblasts, and vascular models consisting of human umbilical vein endothelial cells and 3T3 fibroblasts. To evaluate the effect of co-culture, albumin secretion, and angiogenesis are evaluated. Beaded hydrogel fibers are used to fabricate many size-controlled spheroids for fiber and cloning applications. This method can be widely applied in tissue engineering and cell analysis.


Assuntos
Quitosana , Hidrogéis , Humanos , Polieletrólitos , Alginatos , Células Endoteliais , Técnicas de Cultura de Células/métodos , DNA
5.
Artigo em Inglês | MEDLINE | ID: mdl-37306698

RESUMO

Microarrays are widely utilized in bioanalysis. Electrochemical biosensing techniques are often applied in microarray-based assays because of their simplicity, low cost, and high sensitivity. In such systems, the electrodes and sensing elements are arranged in arrays, and the target analytes are detected electrochemically. These sensors can be utilized for high-throughput bioanalysis and the electrochemical imaging of biosamples, including proteins, oligonucleotides, and cells. In this chapter, we summarize recent progress on these topics. We categorize electrochemical biosensing techniques for array detection into four groups: scanning electrochemical microscopy, electrode arrays, electrochemiluminescence, and bipolar electrodes. For each technique, we summarize the key principles and discuss the advantages, disadvantages, and bioanalysis applications. Finally, we present conclusions and perspectives about future directions in this field.

6.
Front Bioeng Biotechnol ; 11: 1184325, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37274161

RESUMO

Heterogeneous nature is a pivotal aspect of cancer, rendering treatment problematic and frequently resulting in recurrence. Therefore, advanced techniques for identifying subpopulations of a tumour in an intact state are essential to develop novel screening platforms that can reveal differences in treatment response among subpopulations. Herein, we conducted a non-invasive analysis of oxygen metabolism on multiple subpopulations of patient-derived organoids, examining its potential utility for non-destructive identification of subpopulations. We utilised scanning electrochemical microscopy (SECM) for non-invasive analysis of oxygen metabolism. As models of tumours with heterogeneous subpopulations, we used patient-derived cancer organoids with a distinct growth potential established using the cancer tissue-originated spheroid methodology. Scanning electrochemical microscopy measurements enabled the analysis of the oxygen consumption rate (OCR) for individual organoids as small as 100 µm in diameter and could detect the heterogeneity amongst studied subpopulations, which was not observed in conventional colorectal cancer cell lines. Furthermore, our oxygen metabolism analysis of pre-isolated subpopulations with a slow growth potential revealed that oxygen consumption rate may reflect differences in the growth rate of organoids. Although the proposed technique currently lacks single-cell level sensitivity, the variability of oxygen metabolism across tumour subpopulations is expected to serve as an important indicator for the discrimination of tumour subpopulations and construction of novel drug screening platforms in the future.

7.
Anal Sci ; 39(6): 769-770, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37223848
8.
Macromol Biosci ; 23(9): e2300069, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37055930

RESUMO

Hydrogels are widely used in cell culture applications. For fabricating tissues and organs, it is essential to produce hydrogels with specific structures. For instance, multiple-branched hydrogels are desirable for the development of network architectures that resemble the biological vascular network. However, existing techniques are inefficient and time-consuming for this application. To address this issue, a simple, rapid, and large-scale fabrication method based on viscous fingering is proposed. This approach utilizes only two plates. To produce a thin solution, a high-viscosity solution is introduced into the space between the plates, and one of the plates is peeled off. During this procedure, the solution's high viscosity results in the formation of multi-branched structures. Using this strategy, 180 mm × 200 mm multi-branched Pluronic F-127 hydrogels are successfully fabricated within 1 min. These structures are used as sacrificial layers for the fabrication of polydimethylsiloxane channels for culturing human umbilical vein endothelial cells (HUVECs). Similarly, multi-branched Matrigel and calcium (Ca)-alginate hydrogel structures are fabricated, and HUVECs are successfully cultured inside the hydrogels. Also, the hydrogels are collected from the plate, while maintaining their structures. The proposed fabrication technique will contribute to the development of network architectures such as vascular structures in tissue engineering.


Assuntos
Hidrogéis , Engenharia Tecidual , Humanos , Hidrogéis/química , Viscosidade , Engenharia Tecidual/métodos , Células Endoteliais da Veia Umbilical Humana , Alginatos/química , Técnicas de Cultura de Células
9.
Micromachines (Basel) ; 14(2)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36838027

RESUMO

The Limulus amebocyte lysate (LAL) reaction-based assay, the most commonly used endotoxin detection method, requires a skilled technician. In this study, to develop an easy-to-use and highly sensitive endotoxin sensor, we created an electrochemical endotoxin sensor by using an interdigitated array electrode (IDAE) device with advantages of amplifiable signals via redox cycling and portability. We added Boc-Leu-Gly-Arg-p-aminophenol (LGR-pAP) as an electrochemical substrate for an LAL reaction and detected p-aminophenol (pAP) released from LGR-pAP as a product of an endotoxin-induced LAL reaction via an IDAE device. The IDAE device showed a great redox cycling efficiency of 79.8%, and a 4.79-fold signal amplification rate. Then, we confirmed that pAP was detectable in the presence of LGR-pAP through chronoamperometry with the potential of the anode stepped from -0.3 to 0.5 V vs. Ag/AgCl while the cathode was biased at -0.3 V vs. Ag/AgCl. Then, we performed an endotoxin assay by using the IDAE device. Our endotoxin sensor detected as low as 0.7 and 1.0 endotoxin unit/L after the LAL reaction for 1 h and 45 min, respectively, and these data were within the cut-off value for ultrapure dialysis fluid. Therefore, our highly sensitive endotoxin sensor is useful for ensuring medical safety.

10.
Biosens Bioelectron ; 219: 114808, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36327566

RESUMO

Microphysiological systems (MPSs) with three-dimensional (3D) cultured models have attracted considerable interest because of their potential to mimic human health and disease conditions. Recent MPSs have shown significant advancements in engineering perfusable vascular networks integrated with 3D culture models, realizing a more physiological environment in vitro; however, a sensing system that can monitor their activity under biomimetic vascular flow is lacking. We designed an open-top microfluidic device with sensor capabilities and demonstrated its application in analyzing oxygen metabolism in vascularized 3D tissue models. We first validated the platform by using human lung fibroblast (hLF) spheroids. Then, we applied the platform to a patient-derived cancer organoid and evaluated the changes in oxygen metabolism during drug administration through the vascular network. We found that the platform could integrate a perfusable vascular network with 3D cultured cells, and the electrochemical sensor could detect the change in oxygen metabolism in a quantitative, non-invasive, and real-time manner. This platform would become a monitoring system for 3D cultured cells integrated with a perfusable vascular network.

11.
Anal Chem ; 94(47): 16451-16460, 2022 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-36331911

RESUMO

Here, we report a high-sensitivity dual immunoassay using Lumulus amebocyte lysate (LAL) and blood coagulation cascade reactions with redox cycling in a nanoscale-gap electrode. Endotoxin and factor XIa were used as the label molecules for the immunoassay of two types of analytes to induce the LAL and coagulation cascade reactions, respectively, when each corresponding analyte existed in the sample solution. In addition to the signal amplification by the cascade reactions, we employed redox cycling in a nanoscale gap to achieve a highly sensitive assay. The nanoscale-gap electrode amplifies the amperometric signals from p-aminophenol liberated from artificial substrates in the final steps of the cascade reactions. First, the cross reaction between the LAL and coagulation cascade reactions was investigated. The results indicated that these cascade reactions did not efficiently proceed in a single solution owing to the cross reaction. Therefore, we selected to induce two cascade reactions in different solutions by bisecting the beads after the immunocomplex formation on the beads. The cross reactions of factor XIa with the LAL cascade reaction and of endotoxin with the coagulation cascade reaction were investigated. The effects of these cross reactions were revealed to be negligible by bisecting the beads before inducing the cascade reactions. Finally, a dual immunoassay for goat and human immunoglobulin G was performed, for which the limits of detection were 70 pg/mL (470 fmol/L) and 1.0 ng/mL (6.6 pmol/L), respectively. Thus, our dual immunoassay provides a sensitive platform for clinical diagnosis requiring detection of multiple analytes.


Assuntos
Endotoxinas , Fator XIa , Humanos , Imunoensaio/métodos , Eletrodos , Oxirredução
12.
Anal Chem ; 94(36): 12427-12434, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-36027565

RESUMO

Here, we report a highly sensitive immunoassay for human immunoglobulin G (IgG) that uses signal amplification of the coagulation cascade. Z-Phe-Pro-Lys-p-nitroaniline (FPK-pNA) was used as a substrate for thrombin activation in the last step of the coagulation cascade. During the coagulation cascade, pNA is liberated from FPK-pNA and can be detected electrochemically. Using square wave voltammetry with a glassy carbon electrode, we demonstrated that pNA can be quantified in a solution modeling the coagulation cascade prepared by mixing FPK-pNA and pNA. Characterization of the reactivity of thrombin toward FPK-pNA revealed that thrombin efficiently reacted with FPK-pNA. Subsequent characterization of factor XIa activity of factor XIa-labeled antibody revealed that factor XIa was not inactivated during labeling. Finally, a coagulation cascade-based immunoassay for human IgG was performed using a factor XIa-labeled antibody on magnetic beads. The limit of detection for human IgG was 5.0 pg/mL (33 fM) indicating that the coagulation cascade can amplify the immunoassay sensitivity compared to immunoassay using a thrombin-labeled antibody as a condition without a coagulation cascade. Coagulation cascade-based immunoassay was also highly selective. In the near future, we will report a highly sensitive immunoassay for the simultaneous detection of multiple analytes using a coagulation cascade-based immunoassay and Limulus amebocyte lysate reaction-based immunoassay we previously reported.


Assuntos
Coagulação Sanguínea , Trombina , Eletrodos , Humanos , Imunoensaio , Imunoglobulina G
13.
Anal Sci ; 38(10): 1297-1304, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35895213

RESUMO

Endothelial cells have been widely used for vascular biology studies; recent progress in tissue engineering have offered three-dimensional (3D) culture systems for vascular endothelial cells which can be considered as physiologically relevant models. To facilitate the studies, we developed an electrochemical device to detect nitric oxide (NO), a key molecule in the vasculature, for the evaluation of 3D cultured endothelial cells. Using an NO-sensitive catalyst composed of Fe-N co-doped reduced graphene oxide, the real-time monitoring of NO release from the endothelial cell spheroids was demonstrated.


Assuntos
Células Endoteliais , Óxido Nítrico , Carbono , Catálise , Engenharia Tecidual/métodos
14.
Micromachines (Basel) ; 13(4)2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35457875

RESUMO

Recently, biomedical tools have been rapidly miniaturized due to the progress of micro-/nanofabrication technology based on bottom-up and top-down approaches [...].

15.
J Biosci Bioeng ; 133(6): 509-514, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35382990

RESUMO

The industrial use of living organisms for bioproduction of valued substances has been accomplished mostly using microorganisms. To produce high-value bioproducts such as antibodies that require glycosylation modification for better performance, animal cells have been recently gaining attention in bioengineering because microorganisms are unsuitable for producing such substances. Furthermore, animal cells are now classified as products because a large number of cells are required for use in regenerative medicine. In this article, we review animal cell technologies and the use of animal cells, focusing on useable cell generation and large-scale production of animal cells. We review recent advance in mammalian cell line development because this is the first step in the production of recombinant proteins, and it largely affects the efficacy of the production. We next review genetic engineering technology focusing on CRISPR-Cas system as well as surrounding technologies as these methods have been gaining increasing attention in areas that use animal cells. We further review technologies relating to bioreactors used in the context of animal cells because they are essential for the mass production of target products. We also review tissue engineering technology because tissue engineering is one of the main exits for mass-produced cells; in combination with genetic engineering technology, it can prove to be a promising treatment for patients with genetic diseases after the establishment of induced pluripotent stem cell technology. The technologies highlighted in this review cover brief outline of the recent animal cell technologies related to industrial and medical applications.


Assuntos
Sistemas CRISPR-Cas , Engenharia Genética , Animais , Reatores Biológicos , Linhagem Celular , Edição de Genes/métodos , Humanos , Mamíferos/genética , Medicina Regenerativa
16.
Micromachines (Basel) ; 13(3)2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35334714

RESUMO

Three-dimensional organs and tissues can be constructed using hydrogels as support matrices for cells. For the assembly of these gels, chemical and physical reactions that induce gluing should be induced locally in target areas without causing cell damage. Herein, we present a novel electrochemical strategy for gluing hydrogel fibers. In this strategy, a microelectrode electrochemically generated HClO or Ca2+, and these chemicals were used to crosslink chitosan-alginate fibers fabricated using interfacial polyelectrolyte complexation. Further, human umbilical vein endothelial cells were incorporated into the fibers, and two such fibers were glued together to construct "+"-shaped hydrogels. After gluing, the hydrogels were embedded in Matrigel and cultured for several days. The cells spread and proliferated along the fibers, indicating that the electrochemical glue was not toxic toward the cells. This is the first report on the use of electrochemical glue for the assembly of hydrogel pieces containing cells. Based on our results, the electrochemical gluing method has promising applications in tissue engineering and the development of organs on a chip.

17.
Micromachines (Basel) ; 12(12)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34945341

RESUMO

We present a novel methodology based on ion conductance to evaluate the perfusability of vascular vessels in microfluidic devices without microscopic imaging. The devices consisted of five channels, with the center channel filled with fibrin/collagen gel containing human umbilical vein endothelial cells (HUVECs). Fibroblasts were cultured in the other channels to improve the vascular network formation. To form vessel structures bridging the center channel, HUVEC monolayers were prepared on both side walls of the gel. During the culture, the HUVECs migrated from the monolayer and connected to the HUVECs in the gel, and vascular vessels formed, resulting in successful perfusion between the channels after culturing for 3-5 d. To evaluate perfusion without microscopic imaging, Ag/AgCl wires were inserted into the channels, and ion currents were obtained to measure the ion conductance between the channels separated by the HUVEC monolayers. As the HUVEC monolayers blocked the ion current flow, the ion currents were low before vessel formation. In contrast, ion currents increased after vessel formation because of creation of ion current paths. Thus, the observed ion currents were correlated with the perfusability of the vessels, indicating that they can be used as indicators of perfusion during vessel formation in microfluidic devices. The developed methodology will be used for drug screening using organs-on-a-chip containing vascular vessels.

18.
Adv Healthc Mater ; 10(21): e2101186, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34409770

RESUMO

Microphysiological systems (MPS) or organs-on-chips (OoC) can emulate the physiological functions of organs in vitro and are effective tools for determining human drug responses in preclinical studies. However, the analysis of MPS has relied heavily on optical tools, resulting in difficulties in real-time and high spatial resolution imaging of the target cell functions. In this study, the role of scanning probe microscopy (SPM) as an analytical tool for MPS is evaluated. An access hole is made in a typical MPS system with stacked microchannels to insert SPM probes into the system. For the first study, a simple vascular model composed of only endothelial cells is prepared for SPM analysis. Changes in permeability and local chemical flux are quantitatively evaluated during the construction of the vascular system. The morphological changes in the endothelial cells after flow stimulation are imaged at the single-cell level for topographical analysis. Finally, the possibility of adapting the permeability and topographical analysis using SPM for the intestinal vascular system is further evaluated. It is believed that this study will pave the way for an in situ permeability assay and structural analysis of MPS using SPM.


Assuntos
Células Endoteliais , Dispositivos Lab-On-A-Chip , Humanos , Microscopia de Varredura por Sonda , Permeabilidade
19.
Biosens Bioelectron ; 181: 113123, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33714859

RESUMO

The respiratory activity of cultured cells can be electrochemically monitored using scanning electrochemical microscopy (SECM) with high spatial resolution. However, in SECM, the electrode takes a long time to scan, limiting simultaneous measurements with large biological samples such as cell spheroids. Therefore, for rapid electrochemical imaging, a novel strategy is needed. Herein, we report electrochemiluminescence (ECL) imaging of spheroid respiratory activity for the first time using sequential potential steps. L-012, a luminol analog, was used as an ECL luminophore, and H2O2, a sensitizer for ECL of L-012, was generated by the electrochemical reduction of dissolved O2. The ECL imaging visualized spheroid respiratory activity-evidenced by ECL suppression-corresponding to O2 distribution around the spheroids. This method enabled the time-lapse imaging of respiratory activity in multiple spheroids with good spatial resolution comparable to that of SECM. Our work provides a promising high-throughput imaging strategy for elucidating spheroid cellular dynamics.


Assuntos
Técnicas Biossensoriais , Esferoides Celulares , Técnicas Eletroquímicas , Eletrodos , Peróxido de Hidrogênio , Medições Luminescentes , Luminol
20.
Anal Chem ; 93(11): 4902-4908, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33710857

RESUMO

Scanning ion conductance microscopy (SICM) has enabled cell surface topography at a high resolution with low invasiveness. However, SICM has not been applied to the observation of cell surfaces in hydrogels, which can serve as scaffolds for three-dimensional cell culture. In this study, we applied SICM for imaging a cell surface in a microvascular lumen reconstructed in a hydrogel. To achieve this goal, we developed a micropipet navigation technique using ionic current to detect the position of a microvascular lumen. Combining this navigation technique with SICM, endothelial cells in a microvascular model and blebs were visualized successfully at the single-cell level. To the best of our knowledge, this is the first report on visualizing cell surfaces in hydrogels using a SICM. This technique will be useful for furthering our understanding of the mechanism of intravascular diseases.


Assuntos
Células Endoteliais , Microscopia , Membrana Celular , Íons , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...