Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Phys Med ; 66: 88-96, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31574423

RESUMO

PURPOSE: To perform a systematic and thorough assessment, using the Uncomplicated and Cancer-Free Control Probability (UCFCP) function, of a broad range of photon prostate cancer RT treatments, on the same scenario (a unique pelvic CT set). UCFCP considers, together with the probabilities of local tumour control (TCP) and deterministic (late) sequelae (NTCP), the second primary cancer risk (SPCR) due to photon and neutron peripheral doses. METHODS AND MATERIALS: Thirty-six radiotherapy plans were produced for the same CT. 6, 10, 15 and 18 MV 3DCRT, IMRT and VMAT (77.4 Gy in 43 fractions) and 6 and 10 MV SBRT (36.25 Gy in 5 fractions with flattened and FFF beams) for Elekta, Siemens and Varian Linacs plans were included. DVH and peripheral organ dosimetry were used to compute TCP, NTCP, and SPCR (the competition and LNT models) for further plan ranking. RESULTS: Biological models (and parameters) used predicted an outcome which is in agreement with epidemiological findings. SBRT plans showed the lowest SPCR and a below average NTCPrectal. High energy plans did not rank worse than the low energy ones. Intensity modulated plans were ranked above the 3D conformal techniques. CONCLUSIONS: According to UCFCP, the best plans were the10 MV SBRTs. SPCR rates were low and did not show a substantial impact on plan ranking. High energy intensity-modulated plans did not increase in excess the average of SPCR. Even more, they ranked among the best, provided that MU were efficiently managed.


Assuntos
Fótons/uso terapêutico , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional , Humanos , Masculino , Probabilidade , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X
2.
Radiat Prot Dosimetry ; 185(2): 183-195, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-30649534

RESUMO

There is a growing interest in the combined use of Stereotactic Body Radiation Therapy (SBRT) with Flattening Filter Free (FFF) due to the high local control rates and reduced treatment times, compared to conventionally fractionated treatments. It has been suggested that they may also provide a better radiation protection to radiotherapy patients as a consequence of the expected decrease in peripheral doses. This work aims to determine this reduction in unattended out-of-field regions, where no CT information is available but an important percentage of second primary cancers occur. For that purpose, ten different cases suitable for SBRT were chosen. Thus, 142 different treatment plans including SBRT, as well as 3D-CRT, IMRT and VMAT (with standard fractionation) in low and high energies for Varian (FF and FFF), Siemens and Elekta machines were created. Then, photon and neutron peripheral dose in 14 organs were assessed and compared using two analytical models. For the prostate case, uncomplicated and cancer free control probability estimation was also carried out. As a general behavior, SBRT plans led to the lowest peripheral doses followed by 3D-CRT, VMAT and IMRT, in this order. Unflattened beams proved to be the most effective in reducing peripheral doses, especially for 10 MV. The obtained results suggest that FFF beams for SBRT with 10 MV represent the best compromise between dose delivery efficiency and peripheral dose reduction.


Assuntos
Filtração/instrumentação , Segunda Neoplasia Primária/epidemiologia , Neoplasias/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Filtração/métodos , Humanos , Incidência , Neoplasias/classificação , Neoplasias/patologia , Segunda Neoplasia Primária/diagnóstico , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Espanha/epidemiologia
3.
Phys Med ; 42: 345-352, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28372877

RESUMO

PURPOSE: Neutron peripheral contamination in high-energy radiotherapy implies an increase of secondary radiation-induced cancer risk. Although peripheral neutron dose (PND) has been evaluated in organs, few studies have been performed regarding patient size. This work aims to improve an existing methodology for adult patient PND estimations to generalize it to young and children, for its implementation in treatment planning systems (TPS). METHODS: As a first step, we aimed to generalize the previous model to be usable with any thermal neutron detector. Then, taking into account total neutron spectra and dose-to-point thermal neutron fluence measurements for three phantom sizes (adult, teen and child) and two common treatment locations (H&N and abdomen), the new model was proposed. It represents an upgraded parameterization and extension of the existing one, including patient anatomy. Finally, comparison between estimations and measurements, as well as validation against the original model, was carried out for 510 measured patients. RESULTS: Concordance found between experimental and theoretical estimations makes us confident about later implementation in treatment planning systems. Comparison among the previous and upgraded models shows no significant differences for the adult case. However, an important underestimation (34.1% on average) can be observed regarding child case for the original one. CONCLUSIONS: An improved generalization of an existing PND model, considering patient anatomy has been validated and used in real patients. The final methodology is easily implementable in clinical routine and TPS thanks to the ready availability of input parameters (patient height and weight, high-energy MU and facility characterization).


Assuntos
Modelos Teóricos , Nêutrons/uso terapêutico , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia , Adolescente , Adulto , Criança , Simulação por Computador , Humanos , Método de Monte Carlo , Neoplasias Induzidas por Radiação/prevenção & controle , Fótons/uso terapêutico , Radioterapia/instrumentação
4.
Appl Radiat Isot ; 123: 32-35, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28214683

RESUMO

One of the major causes of secondary malignancies after radiotherapy treatments are peripheral doses, known to increase for some newer techniques (such as IMRT or VMAT). For accelerators operating above 10MV, neutrons can represent important contribution to peripheral doses. This neutron contamination can be measured using different passive or active techniques, available in the literature. As far as active (or direct-reading) procedures are concerned, a major issue is represented by their parasitic photon sensitivity, which can significantly affect the measurement when the point of test is located near to the field-edge. This work proposes a simple method to estimate the unwanted photon contribution to these neutrons. As a relevant case study, the use of a recently neutron sensor for "in-phantom" measurements in high-energy machines was considered. The method, called "Dual Energy Photon Subtraction" (DEPS), requires pairs of measurements performed for the same treatment, in low-energy (6MV) and high energy (e.g. 15MV) fields. It assumes that the peripheral photon dose (PPD) at a fixed point in a phantom, normalized to the unit photon dose at the isocenter, does not depend on the treatment energy. Measurements with ionization chamber and Monte Carlo simulations were used to evaluate the validity of this hypothesis. DEPS method was compared to already published correction methods, such as the use of neutron absorber materials. In addition to its simplicity, an advantage of DEPs procedure is that it can be applied to any radiotherapy machine.


Assuntos
Nêutrons Rápidos , Fótons , Radiometria/métodos , Dosagem Radioterapêutica , Simulação por Computador , Nêutrons Rápidos/efeitos adversos , Humanos , Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Imagens de Fantasmas , Fótons/efeitos adversos , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Radioterapia de Intensidade Modulada/efeitos adversos , Espalhamento de Radiação
5.
Appl Radiat Isot ; 115: 49-54, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27337649

RESUMO

The increasing interest of the medical community to radioinduced second malignancies due to photoneutrons in patients undergoing high-energy radiotherapy, has stimulated in recent years the study of peripheral doses, including the development of some dedicated active detectors. Although these devices are designed to respond to neutrons only, their parasitic photon response is usually not identically zero and anisotropic. The impact of these facts on measurement accuracy can be important, especially in points close to the photon field-edge. A simple method to estimate the photon contribution to detector readings is to cover it with a thermal neutron absorber with reduced secondary photon emission, such as a borated rubber. This technique was applied to the TNRD (Thermal Neutron Rate Detector), recently validated for thermal neutron measurements in high-energy photon radiotherapy. The positive results, together with the accessibility of the method, encourage its application to other detectors and different clinical scenarios.


Assuntos
Nêutrons , Radiometria , Radioterapia de Alta Energia , Humanos , Fótons
6.
Appl Radiat Isot ; 107: 330-334, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26595777

RESUMO

Active thermal neutron detectors are used in a wide range of measuring devices in medicine, industry and research. For many applications, the long-term stability of these devices is crucial, so that very well controlled neutron fields are needed to perform calibrations and repeatability tests. A way to achieve such reference neutron fields, relying on a 3 MV Tandem Pelletron accelerator available at the CNA (Seville, Spain), is reported here. This paper shows thermal neutron field production and reproducibility characteristics over few days.


Assuntos
Nêutrons , Aceleradores de Partículas , Calibragem , Desenho de Equipamento , Humanos , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Reprodutibilidade dos Testes , Espanha
7.
Med Phys ; 41(11): 112105, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25370656

RESUMO

PURPOSE: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. METHODS: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. RESULTS: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. CONCLUSIONS: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an easy implementation of specific peripheral neutron dose models for any type of treatment and facility.


Assuntos
Nêutrons , Radiometria/instrumentação , Radiometria/métodos , Radioterapia/métodos , Antropometria , Calibragem , Estudos de Coortes , Desenho de Equipamento , Humanos , Modelos Estatísticos , Neoplasias/diagnóstico , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Imagens de Fantasmas , Doses de Radiação , Radiografia , Dosagem Radioterapêutica , Análise de Regressão , Reprodutibilidade dos Testes , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...