Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Rapid Commun Mass Spectrom ; 30(8): 1019-30, 2016 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-27003039

RESUMO

RATIONALE: Continuous-flow reaction detection systems (monitoring enzymatic reactions with mass spectrometry (MS)) lack quantitative values so far. Therefore, two independent internal standards (IS) are implemented in a way that the online system stability can be observed, quantitative conversion values for substrate and product can be obtained and they can be used as mass calibration standards for high MS accuracy. METHODS: An application previously developed for the MS detection of peptide phosphorylation by cAMP-dependent protein kinase A (PKA) (De Boer et al., Anal. Bioanal. Chem. 2005, 381, 647-655) was transferred to a continuous-flow reaction detection system. This enzymatic reaction, involving enzyme activation as well as the transfer of a phosphate group from ATP to a peptide substrate, was used to prove the compatibility of a quantitative enzymatic assay in a continuous-flow real-time system (connected to MS). RESULTS: Moreover (using internal standards), the critical parameter reaction temperature (including solution density variations depending on temperature) was studied in the continuous-flow mixing system. Furthermore, two substrates (malantide and kemptide), two enzyme types (catalytic subunit of PKA and complete PKA) and one inhibitor were tested to determine system robustness and long-term availability. Even spraying solutions that contained significant amount of MS contaminants (e.g. the polluted catalytic subunit) resulted in quantifiable MS signal intensities. Subsequent recalculations using the internal standards led to results representing the power of this application. CONCLUSIONS: The presented methodology and the data evaluation with available Achroma freeware enable the direct coupling of biochemical assays with quantitative MS detection. Monitoring changes such as temperature, reaction time, inhibition, or compound concentrations can be observed quantitatively and thus enzymatic activity can be calculated.


Assuntos
Proteínas Quinases Dependentes de AMP Cíclico/metabolismo , Ensaios Enzimáticos/métodos , Espectrometria de Massas/métodos , Software , Ensaios Enzimáticos/normas , Espectrometria de Massas/normas , Modelos Químicos , Oligopeptídeos/análise , Oligopeptídeos/metabolismo , Peptídeos/análise , Peptídeos/metabolismo , Fosforilação , Padrões de Referência , Processamento de Sinais Assistido por Computador
2.
FASEB J ; 26(5): 1810-20, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22308197

RESUMO

Adolescence is a critical developmental period during which most adult smokers initiate their habit. Adolescents are more vulnerable than adults to nicotine's long-term effects on addictive and cognitive behavior. We investigated whether adolescent nicotine exposure in rats modifies expression of nicotinic acetylcholine receptors (nAChRs) in medial prefrontal cortex (mPFC) in the short and/or long term, and whether this has functional consequences. Using receptor binding studies followed by immunoprecipitation of nAChR subunits, we showed that adolescent nicotine exposure, as compared with saline, caused an increase in mPFC nAChRs containing α4 or ß2 subunits (24 and 18%, respectively) 24 h after the last injection. Nicotine exposure in adulthood had no such effect. This increase was transient and was not observed 5 wk following either adolescent or adult nicotine exposure. In line with increased nAChRs expression 1 d after adolescent nicotine exposure, we observed a 34% increase in amplitude of nicotine-induced spontaneous inhibitory postsynaptic currents in layer II/III mPFC pyramidal neurons. These effects were transient and specific, and observed only acutely after adolescent nicotine exposure, but not after 5 wk, and no changes were observed in adult-exposed animals. The acute nicotine-induced increase in α4ß2-containing receptors in adolescents interferes with the normal developmental decrease (37%) of these receptors from early adolescence (postnatal day 34) to adulthood (postnatal day 104) in the mPFC. Together, this suggests that these receptors play a role in mediating the acute rewarding effects of nicotine and may underlie the increased sensitivity of adolescents to nicotine.


Assuntos
Modelos Animais , Nicotina/administração & dosagem , Córtex Pré-Frontal/metabolismo , Receptores Nicotínicos/metabolismo , Transmissão Sináptica , Adolescente , Animais , Cromatografia Líquida , Feminino , Humanos , Imunoprecipitação , Nicotina/metabolismo , Gravidez , Ratos , Ratos Wistar , Espectrometria de Massas por Ionização por Electrospray
3.
Anal Bioanal Chem ; 403(2): 367-75, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22227812

RESUMO

In this study, an integrated approach is developed for the formation, identification and biological characterization of electrochemical conversion products of p38α mitogen-activated protein kinase inhibitors. This work demonstrates the hyphenation of an electrochemical reaction cell with a continuous-flow bioaffinity assay and parallel LC-HR-MS. Competition of the formed products with a tracer (SKF-86002) that shows fluorescence enhancement in the orthosteric binding site of the p38α kinase is the readout for bioaffinity. Parallel HR-MS(n) experiments provided information on the identity of binders and non-binders. Finally, the data produced with this on-line system were compared to electrochemical conversion products generated off-line. The electrochemical conversion of 1-{6-chloro-5-[(2R,5S)-4-(4-fluorobenzyl)-2,5-dimethylpiperazine-1-carbonyl]-3aH-indol-3-yl}-2-morpholinoethane-1,2-dione resulted in eight products, three of which showed bioaffinity in the continuous-flow p38α bioaffinity assay used. Electrochemical conversion of BIRB796 resulted, amongst others, in the formation of the reactive quinoneimine structure and its corresponding hydroquinone. Both products were detected in the p38α bioaffinity assay, which indicates binding to the p38α kinase.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Inibidores Enzimáticos/química , Espectrometria de Massas/métodos , Proteína Quinase 14 Ativada por Mitógeno/antagonistas & inibidores , Sítios de Ligação , Cromatografia Líquida de Alta Pressão/instrumentação , Avaliação Pré-Clínica de Medicamentos , Eletroquímica/instrumentação , Inibidores Enzimáticos/farmacologia , Humanos , Cinética , Espectrometria de Massas/instrumentação , Proteína Quinase 14 Ativada por Mitógeno/química , Ligação Proteica
4.
J Biomol Screen ; 16(8): 917-24, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21799121

RESUMO

This study describes the evaluation, validation, and use of contactless postcolumn fractionation of bioactive mixtures with acetylcholine binding protein (AChBP) affinity analysis with help of a spotter technology. The high-resolution fractionation tailors the fractionation frequency to the chromatographic peaks. Postcolumn reagents for AChBP bioaffinity profiling are mixed prior to droplet ejection into 1536-well plates. After an incubation step, microplate reader analysis is used to determine bioactive compounds in a mixture. For ligands tested, a good correlation was found for IC(50)s determined in flow injection analysis mode when compared with traditional radioligand binding assays. After the evaluation and validation, bioaffinity profiling of actual mixtures was performed. The advantage of this "atline" technology using postcolumn bioaffinity analysis when compared to continuous flow online postcolumn bioaffinity profiling is the possibility to choose postcolumn incubation times freely without compromising resolution due to diffusion effects.


Assuntos
Proteínas de Transporte , Cromatografia de Afinidade/métodos , Cromatografia Líquida de Alta Pressão/métodos , Misturas Complexas/análise , Análise de Injeção de Fluxo/métodos , Ensaios de Triagem em Larga Escala , Compostos Bicíclicos Heterocíclicos com Pontes/análise , Compostos Bicíclicos Heterocíclicos com Pontes/metabolismo , Proteínas de Transporte/química , Proteínas de Transporte/metabolismo , Fracionamento Químico/métodos , Cromatografia de Afinidade/instrumentação , Misturas Complexas/química , Análise de Injeção de Fluxo/instrumentação , Ligantes , Espectrometria de Massas/métodos , Nanotecnologia/métodos , Nicotina/análise , Nicotina/metabolismo , Agonistas Nicotínicos/análise , Agonistas Nicotínicos/metabolismo , Ligação Proteica , Piridinas/análise , Piridinas/metabolismo , Ensaio Radioligante , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Reprodutibilidade dos Testes
5.
Anal Bioanal Chem ; 401(4): 1109-25, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21755271

RESUMO

This review discusses the most important current methods employing mass spectrometry (MS) analysis for the study of protein affinity interactions. The methods are discussed in depth with particular reference to MS-based approaches for analyzing protein-protein and protein-immobilized ligand interactions, analyzed either directly or indirectly. First, we introduce MS methods for the study of intact protein complexes in the gas phase. Next, pull-down methods for affinity-based analysis of protein-protein and protein-immobilized ligand interactions are discussed. Presently, this field of research is often called interactomics or interaction proteomics. A slightly different approach that will be discussed, chemical proteomics, allows one to analyze selectivity profiles of ligands for multiple drug targets and off-targets. Additionally, of particular interest is the use of surface plasmon resonance technologies coupled with MS for the study of protein interactions. The review addresses the principle of each of the methods with a focus on recent developments and the applicability to lead compound generation in drug discovery as well as the elucidation of protein interactions involved in cellular processes. The review focuses on the analysis of bioaffinity interactions of proteins with other proteins and with ligands, where the proteins are considered as the bioactives analyzed by MS.


Assuntos
Proteínas Imobilizadas , Espectrometria de Massas , Proteínas/química , Humanos , Proteínas Imobilizadas/química , Proteínas Imobilizadas/metabolismo , Ligantes , Proteínas/metabolismo , Proteômica/métodos
6.
Anal Chim Acta ; 698(1-2): 69-76, 2011 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-21645661

RESUMO

In this paper we describe the hyphenation of high temperature liquid chromatography with ICP-MS and ESI-MS for the characterization of halogen containing drug metabolites. The use of temperature gradients up to 200°C enabled the separation of metabolites with low organic modifier content. This specific property allowed the use of detection methods that suffer from (significant) changes in analyte response factors as a function of the organic modifier content such as ICP-MS. Metabolites of two kinase inhibitors (SB-203580-Iodo and MAPK inhibitor VIII) produced by bacterial cytochrome P450 BM3 mutants and human liver microsomes were identified based on high resolution MS(n) data. Quantification was done using their normalized and elemental specific response in the ICP-MS. The importance of these kinds of quantification strategies is stressed by the observation that the difference of the position of one oxygen atom in a structure can greatly affect its response in ESI-MS and UV detection.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Halogênios/análise , Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Bromo/análise , Bromo/química , Bromo/metabolismo , Feminino , Halogênios/química , Halogênios/metabolismo , Temperatura Alta , Humanos , Imidazóis/análise , Imidazóis/química , Imidazóis/metabolismo , Iodo/análise , Iodo/química , Iodo/metabolismo , Limite de Detecção , Masculino , Microssomos Hepáticos/química , Microssomos Hepáticos/metabolismo , Oxigênio/análise , Oxigênio/química , Oxigênio/metabolismo , Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Inibidores de Proteínas Quinases/análise , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/metabolismo , Piridinas/análise , Piridinas/química , Piridinas/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos
7.
Talanta ; 84(3): 623-31, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21482259

RESUMO

Current development in catalyst discovery includes combinatorial synthesis methods for the rapid generation of compound libraries combined with high-throughput performance-screening methods to determine the associated activities. Of these novel methodologies, mass spectrometry (MS) based flow chemistry methods are especially attractive due to the ability to combine sensitive detection of the formed reaction product with identification of introduced catalyst complexes. Recently, such a mass spectrometry based continuous-flow reaction detection system was utilized to screen silver-adducted ferrocenyl bidentate catalyst complexes for activity in a multicomponent synthesis of a substituted 2-imidazoline. Here, we determine the merits of different ionization approaches by studying the combination of sensitive detection of product formation in the continuous-flow system with the ability to simultaneous characterize the introduced [ferrocenyl bidentate+Ag](+) catalyst complexes. To this end, we study the ionization characteristics of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), no-discharge APCI, dual ESI/APCI, and dual APCI/no-discharge APCI. Finally, we investigated the application potential of the different ionization approaches by the investigation of ferrocenyl bidentate catalyst complex responses in different solvents.


Assuntos
Espectrometria de Massas/métodos , Catálise , Ligantes
8.
J Pharm Biomed Anal ; 55(1): 85-92, 2011 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-21300511

RESUMO

Galantamine hydrobromide was subjected to different stress conditions (acidic, alkaline, thermal, photolytic and oxidative). Degradation was found to occur under acidic, photolytic and oxidative conditions, while the drug was stable under alkaline and elevated temperature conditions. A stability-indicating reversed-phase liquid chromatographic method was developed for the determination of the drug in the presence of its degradation products. The method was validated for linearity, precision, accuracy, specificity, selectivity and intermediate precision. Additionally, the degradation kinetics of the drug was assessed in relevant cases. The kinetics followed a first order behavior in the case of acidic and photolytic degradation, while a two-phase kinetics behavior was found for the oxidative degradation. The degradation products were characterized by mass spectrometry and nuclear magnetic resonance spectroscopy. Dehydration, epimerization and N-oxidation were the main processes observed during the degradation of galantamine. Moreover, if sufficient material could be isolated the inhibitory activity against the target enzyme acetylcholinesterase was also assessed.


Assuntos
Inibidores da Colinesterase/química , Galantamina/química , Tecnologia Farmacêutica , Doença de Alzheimer/tratamento farmacológico , Inibidores da Colinesterase/análise , Inibidores da Colinesterase/farmacologia , Inibidores da Colinesterase/efeitos da radiação , Colinesterases/metabolismo , Cromatografia Líquida de Alta Pressão , Estabilidade de Medicamentos , Galantamina/análogos & derivados , Galantamina/farmacologia , Galantamina/efeitos da radiação , Temperatura Alta/efeitos adversos , Concentração de Íons de Hidrogênio , Cinética , Luz/efeitos adversos , Espectroscopia de Ressonância Magnética , Oxirredução , Fotólise , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Estereoisomerismo , Espectrometria de Massas em Tandem
9.
Anal Bioanal Chem ; 399(8): 2669-81, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21058031

RESUMO

This review provides an overview of direct and indirect technologies to screen protein-ligand interactions with mass spectrometry. These technologies have as a key feature the selection or affinity purification of ligands in mixtures prior to detection. Specific fields of interest for these technologies are metabolic profiling of bioactive metabolites, natural extract screening, and the screening of libraries for bioactives, such as parallel synthesis libraries and small combichem libraries. The review addresses the principles of each of the methods discussed, with a focus on developments in recent years, and the applicability of the methods to lead generation and development in drug discovery.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Espectrometria de Massas/métodos , Proteínas/química , Ligantes , Ligação Proteica
10.
Anal Chem ; 83(1): 125-32, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21117623

RESUMO

The development of a contactless postcolumn spotter technology capable of rapidly and accurately depositing LC eluent onto another platform (e.g., 1536-well microtiter plates) is described. Many detection methodologies are suitable for online analysis, such as mass spectrometry, UV-vis, and fluorescence. In some cases, when online analysis is less suitable, off-line postcolumn analysis is the methodology of choice and usually relies on LC-based fractionation prior to detection (e.g., MALDI-MS, Raman spectrsocopy, biochemical assays). As fractionation generally involves loss in resolution, the technology described here allows high-resolution contactless fractionation by tailoring the fractionation frequency to the chromatographic peaks and mixing in of postcolumn reagents. Droplet ejection at frequencies of at least 6 Hz could be performed in the nanoliter to low microliter range with repeatabilities of ∼6%. Furthermore, multiple droplets can be ejected at the same position thereby allowing adjustment of fractionation volume and speed. The technology was evaluated, optimized, and validated prior to two proof-of-principle demonstrations comprising off-line chemical detection of injected fluorescein and off-line postcolumn biochemical detection of acetylcholine-binding protein ligands, both based on 1536-well plate reader analysis.


Assuntos
Fracionamento Químico/métodos , Cromatografia Líquida/métodos , Nanotecnologia/métodos , Animais , Proteínas de Transporte/isolamento & purificação , Proteínas de Transporte/metabolismo , Linhagem Celular , Fracionamento Químico/instrumentação , Fluoresceína/química , Indicadores e Reagentes/química , Espectrometria de Massas , Nanotecnologia/instrumentação , Reprodutibilidade dos Testes , Fatores de Tempo
11.
Anal Bioanal Chem ; 399(8): 2655-68, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21107824

RESUMO

In the screening of complex mixtures, for example combinatorial libraries, natural extracts, and metabolic incubations, different approaches are used for integrated bioaffinity screening. Four major strategies can be used for screening of bioactive mixtures for protein targets-pre-column and post-column off-line, at-line, and on-line strategies. The focus of this review is on recent developments in post-column on-line screening, and the role of mass spectrometry (MS) in these systems. On-line screening systems integrate separation sciences, mass spectrometry, and biochemical methodology, enabling screening for active compounds in complex mixtures. There are three main variants of on-line MS based bioassays: the mass spectrometer is used for ligand identification only; the mass spectrometer is used for both ligand identification and bioassay readout; or MS detection is conducted in parallel with at-line microfractionation with off-line bioaffinity analysis. On the basis of the different fields of application of on-line screening, the principles are explained and their usefulness in the different fields of drug research is critically evaluated. Furthermore, off-line screening is discussed briefly with the on-line and at-line approaches.


Assuntos
Misturas Complexas/análise , Espectrometria de Massas , Animais , Bioensaio , Humanos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Proteínas/análise
12.
J Mass Spectrom ; 45(11): 1332-43, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20967738

RESUMO

Ferrocene is a popular template in material science due to its exceptional characteristics that offer the ability to optimize the selectivity and activity of catalysts by the addition of carefully selected substituents. In combinatorial catalyst development, the high susceptibility to electrophilic substitution reactions offers the opportunity for the rapid introduction of molecular diversity. Mass spectrometry (MS)-based continuous-flow systems can be applied to rapidly evaluate catalyst performance as well as to (provisionally) identify the introduced catalyst complexes. Herein, we describe the fragmentation characteristics of the [ferrocenyl bidentate + Ag](+) catalyst complexes in dedicated (high-resolution) MS(n) experiments. The investigation of the fragmentation patterns of a selected number of catalyst classes is accompanied with a density functional theory investigation of fragmentation intermediates in order to assess the viability of a selected fragmentation mechanism.


Assuntos
Compostos Ferrosos/química , Compostos de Prata/química , Espectrometria de Massas em Tandem/métodos , Catálise , Íons/química , Metalocenos , Termodinâmica
13.
J Biomol Screen ; 15(8): 978-89, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20817886

RESUMO

Fragment-based drug discovery (FBDD) has become a widely accepted tool that is complementary to high-throughput screening (HTS) in developing small-molecule inhibitors of pharmaceutical targets. Because a fragment campaign can only be as successful as the hit matter found, it is critical that the first stage of the process be optimized. Here the authors compare the 3 most commonly used methods for hit discovery in FBDD: high concentration screening (HCS), solution ligand-observed nuclear magnetic resonance (NMR), and surface plasmon resonance (SPR). They selected the commonly used saturation transfer difference (STD) NMR spectroscopy and the proprietary target immobilized NMR screening (TINS) as representative of the array of possible NMR methods. Using a target typical of FBDD campaigns, the authors find that HCS and TINS are the most sensitive to weak interactions. They also find a good correlation between TINS and STD for tighter binding ligands, but the ability of STD to detect ligands with affinity weaker than 1 mM K(D) is limited. Similarly, they find that SPR detection is most suited to ligands that bind with K(D) better than 1 mM. However, the good correlation between SPR and potency in a bioassay makes this a good method for hit validation and characterization studies.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Proteínas Imobilizadas/química , Ressonância Magnética Nuclear Biomolecular/métodos , Fragmentos de Peptídeos/isolamento & purificação , Ressonância de Plasmônio de Superfície/métodos , Técnicas Biossensoriais/métodos , Descoberta de Drogas/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Proteínas Imobilizadas/metabolismo , Proteínas Imobilizadas/farmacologia , Ligantes , Modelos Biológicos , Terapia de Alvo Molecular , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Biblioteca de Peptídeos , Ligação Proteica , Bibliotecas de Moléculas Pequenas/análise
14.
J Med Chem ; 53(19): 7192-201, 2010 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-20828128

RESUMO

The soluble acetylcholine binding protein (AChBP) is a homologue of the ligand-binding domain of the nicotinic acetylcholine receptors (nAChR). To guide future fragment-screening using surface plasmon resonance (SPR) biosensor technology as a label-free, direct binding, biophysical screening assay, a focused fragment library was generated based on deconstruction of a set of α7 nAChR selective quinuclidine containing ligands with nanomolar affinities. The interaction characteristics of the fragments and the parent compounds with AChBP were evaluated using an SPR biosensor assay. The data obtained from this direct binding assay correlated well with data from the reference radioligand displacement assay. Ligand efficiencies for different (structural) groups of fragments in the library were correlated to binding with distinct regions of the binding pocket, thereby identifying ligand efficiency hot spots (LE hot spots). These hot spots can be used to identity the most promising hit fragments in a large scale fragment library screen.


Assuntos
Carbamatos/química , Proteínas de Transporte/química , Modelos Moleculares , Piridinas/química , Quinuclidinas/química , Receptores Nicotínicos/química , Animais , Aplysia , Sítios de Ligação , Ligação Competitiva , Técnicas Biossensoriais , Carbamatos/síntese química , Humanos , Ligantes , Lymnaea , Piridinas/síntese química , Quinuclidinas/síntese química , Ensaio Radioligante , Relação Estrutura-Atividade , Ressonância de Plasmônio de Superfície
15.
Anal Bioanal Chem ; 398(7-8): 3023-32, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20872136

RESUMO

One way to profile complex mixtures for receptor affinity is to couple liquid chromatography (LC) on-line to biochemical detection (BCD). A drawback of this hyphenated screening approach is the relatively high consumption of sample, receptor protein and (fluorescently labeled) tracer ligand. Here, we worked toward minimization of sample and reagent consumption, by coupling nano-LC on-line to a light-emitting diode (LED) based capillary confocal fluorescence detection system capable of on-line BCD with low-flow rates. In this fluorescence detection system, a capillary with an extended light path (bubble cell) was used as a detection cell in order to enhance sensitivity. The technology was applied to a fluorescent enhancement bioassay for the acetylcholine binding protein, a structural analog of the extracellular ligand-binding domain of neuronal nicotinic acetylcholine receptors. In the miniaturized setup, the sensitive and low void volume LED-induced confocal fluorescence detection system operated in flow injection analysis mode allowing the measurement of IC(50) values, which were comparable with those measured by a conventional plate reader bioassay. The current setup uses 50 nL as injection volume with a carrier flow rate of 400 nL/min. Finally, coupling of the detection system to gradient reversed-phase nano-LC allowed analysis of mixtures in order to identify the bioactive compounds present by injecting 10 nL of each mixture.


Assuntos
Bioensaio/métodos , Cromatografia Líquida/métodos , Análise de Injeção de Fluxo/métodos , Microfluídica/métodos , Microscopia de Fluorescência/métodos , Bioensaio/instrumentação , Proteínas de Transporte/análise , Microfluídica/instrumentação
16.
Anal Bioanal Chem ; 398(4): 1771-80, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20730527

RESUMO

A high-resolution screening method was developed for the p38α mitogen-activated protein kinase to detect and identify small-molecule binders. Its central role in inflammatory diseases makes this enzyme a very important drug target. The setup integrates separation by high-performance liquid chromatography with two parallel detection techniques. High-resolution mass spectrometry gives structural information to identify small molecules while an online enzyme binding detection method provides data on p38α binding. The separation step allows the individual assessment of compounds in a mixture and links affinity and structure information via the retention time. Enzyme binding detection was achieved with a competitive binding assay based on fluorescence enhancement which has a simple principle, is inexpensive, and is easy to interpret. The concentrations of p38α and the fluorescence tracer SK&F86002 were optimized as well as incubation temperature, formic acid content of the LC eluents, and the material of the incubation tubing. The latter notably improved the screening of highly lipophilic compounds. For optimization and validation purposes, the known kinase inhibitors BIRB796, TAK715, and MAPKI1 were used among others. The result is a high-quality assay with Z' factors around 0.8, which is suitable for semi-quantitative affinity measurements and applicable to various binding modes. Furthermore, the integrated approach gives affinity data on individual compounds instead of averaged ones for mixtures.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Proteína Quinase 14 Ativada por Mitógeno/química , Ligação Competitiva , Humanos , Cinética , Ligação Proteica
17.
Anal Biochem ; 407(1): 58-64, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20599657

RESUMO

Surface plasmon resonance (SPR) biosensors recently gained an important place in drug discovery. Here we present a primary and secondary SPR biosensor screening methodology. The primary screening method is based on a direct binding assay with covalent immobilized drug target proteins. For the secondary screening method, a sequential competition assay has been developed where the captured protein is first exposed to an unknown test compound, followed directly by an exposure to a high-molecular-weight reporter ligand. Using the high-molecular-weight reporter ligand to probe the remaining free binding site on the sensor, a significant signal enhancement is obtained. Furthermore, this assay format allows the validation of the primary direct binding assay format, efficiently revealing false positive data. As a model system, acetylcholine binding protein (AChBP), which is a soluble model protein for neuronal nicotinic acetylcholine receptors, has been used. The secondary assay is lower in throughput than the primary assay; however, the signal-to-noise ratio is two times higher compared with the direct assay, and it has a z' factor of 0.96. Using both assays, we identified the compound tacrine as a ligand for AChBP.


Assuntos
Ligantes , Receptores Nicotínicos/metabolismo , Ressonância de Plasmônio de Superfície/métodos , Sítios de Ligação , Ligação Proteica , Receptores Nicotínicos/química , Receptores Nicotínicos/genética , Proteínas Recombinantes/química , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/metabolismo , Tacrina/química
18.
Chromatographia ; 72(1-2): 7-13, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20628447

RESUMO

A new methodology is described enabling the affinity screening of potential ligands towards the human estrogen receptor alpha ligand binding domain (ERalpha-LBD). In-solution incubation is performed of the analyte and the His-tagged ERalpha-LBD. The bound complex is immobilized on a nickel-loaded protein-affinity selection column, where after the unbound fraction is removed. The immobilized protein-ligand complex is exposed to a decreased pH value and an increased organic modifier concentration releasing the ligand for MS detection, and precipitating the proteins on a filter positioned between the affinity column and the mass spectrometer. The trapping column can be regenerated for reuse at least 70 times. The advantages of the methodology over existing methodologies are the absence of a pre-concentration as well as a chromatographic separation step, resulting in a significantly shorter analysis time compared to previously described procedures, and in addition, allowing the determination of solutes with unfavorable chromatographic properties. The overall analysis time now can be reduced about 250% to approximately 6 min. Replacing the filters after every measurement results in an intra-day standard deviation of 14.8% and an inter-day standard deviation of 21.3%.

19.
J Med Chem ; 53(12): 4720-30, 2010 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-20518527

RESUMO

The acetylcholine binding protein (AChBP) is considered an analogue for the ligand-binding domain of neuronal nicotinic acetylcholine receptors (nAChRs). Its stability and solubility in aqueous buffer allowed the development of an online bioaffinity analysis system. For this, a tracer ligand which displays enhanced fluorescence in the binding pocket of AChBP was identified from a concise series of synthetic benzylidene anabaseines. Evaluation and optimization of the bioaffinity assay was performed in a convenient microplate reader format and subsequently transferred to the online format. The high reproducibility has the prospect of estimating the affinities of ligands from an in-house drug discovery library injected in one known concentration. Furthermore, the online bioaffinity analysis system could also be applied to mixture analysis by using gradient HPLC. This led to the possibility of affinity ranking of ligands in mixtures with parallel high-resolution mass spectrometry for compound identification.


Assuntos
Anabasina/análogos & derivados , Proteínas de Transporte/química , Anabasina/síntese química , Anabasina/química , Sítios de Ligação , Cromatografia Líquida , Descoberta de Drogas , Análise de Injeção de Fluxo , Fluorometria , Ligantes , Espectrometria de Massas/métodos , Ligação Proteica , Ensaio Radioligante , Reprodutibilidade dos Testes
20.
J Pharm Biomed Anal ; 53(3): 609-16, 2010 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-20466502

RESUMO

The present paper describes a methodology for rapid assessment of chemical and biological degradation products of tacrine and their bioactivity for acetylcholinesterase (AChE). Analysis was achieved by utilizing liquid chromatography coupled to parallel high resolution mass spectrometry and an on-line continuous-flow AChE bioassay for biochemical detection. Key advantage of the strategy described involves the straightforward chemical production of large quantities of products of which many were the same as formed during the biological degradation by cytochromes P450 (CYPs). For this, chemical degradation of tacrine was evaluated under acidic, basic and oxidative conditions as well as elevated temperatures and light exposure. Chemical degradation products were only formed after 2h under reflux with 3% hydrogen peroxide, where more than 50% of tacrine was converted to degradation products. Many of these products showed bioactivity. Mostly, mono-, di- or tri-oxygenated compounds were observed. This study demonstrated that the combination of chemical and biological degradation provides valuable information indicating that assessment of biological activity is important not only for biological degradation products, but also for chemical degradation products when formed. Furthermore, chemical degradation can be used to produce conveniently and in relatively large quantities clean mixtures of compounds that are also produced during metabolic incubations.


Assuntos
Acetilcolinesterase/metabolismo , Tacrina/metabolismo , Acetilcolinesterase/química , Animais , Microssomos Hepáticos/metabolismo , Ratos , Suínos , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA