1.
Postgrad Med ; 125(3): 91-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23748510

RESUMO

BACKGROUND: Point-of-care testing (POCT) is widely used to measure blood glucose levels in people with diabetes, although its use in measuring glycated hemoglobin (HbA1c) levels is less common, perhaps due to perceived performance issues and access to the technology. METHODS: Forty blood samples were analyzed in duplicate using Bayer's A1CNow + ® Multi-Test A1C system (A1CNow + ) with 3 different reagent lots; HbA1c levels of the samples spanned the clinically relevant range of 4% to 10%. Corresponding samples were sent to a National Glycohemoglobin Standardization Program (NGSP) secondary reference laboratory (University of Missouri Secondary Reference Laboratory #9), which analyzed the samples with a Tosoh Automated Glycohemoglobin Analyzer HLC-723G8 (Tosoh G8; Tosoh Bioscience, Inc). RESULTS: Glycated hemoglobin levels measured with the A1CNow + aligned with measurements obtained using the laboratory method, with correlation coefficients of 0.985, 0.987, and 0.989 for the 3 lots, respectively. The 95% CIs for the differences between the A1CNow + levels and the mean HbA1c levels were within -0.55% to +0.50% for the 3 reagent lots, which is well within the currently acceptable limits of ±0.75% HbA1c required by the NGSP. Results were further analyzed per the new tighter NGSP performance criteria effective September 1, 2012, requiring that 37 of 40 results be within ±7% (relative bias) of the NGSP reference laboratory measures. All 3 lots met the tighter NGSP criteria. CONCLUSION: The A1CNow + provides accuracy and precision when performing POCT of HbA1c as an aid in diabetes management. Ongoing improvements in this and other HbA1c POCT devices may lead to a greater global acceptance of the role of POCT of HbA1c in diabetes management.


Assuntos
Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Autoanálise/normas , Diabetes Mellitus/sangue , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/normas , Reprodutibilidade dos Testes
2.
J Diabetes Sci Technol ; 1(3): 405-11, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-19885097

RESUMO

Measurement of hemoglobin A1c (A1C) has long been accepted as the best indicator of glucose control over time. Assays for A1C use technologies based on either charge differences (high-pressure liquid chromatography) or structure (boronate affinity or immunoassay combined with general chemistry). These technologies are generally employed in expensive laboratory instruments. More recently, A1C technology has been incorporated into point of care (POC) devices, allowing for immediate availability of A1C measurements, greatly facilitating diabetes care in both specialist and general practices. POC A1C tests should have acceptable performance, standardization to national reference, National Glycohemoglobin Standardization Program (NGSP) certification, simple operation without need for costly instrumentation, and Clinical Laboratory Improvement Amendments (CLIA) waiver. CLIA-waived POC technology includes Bio-Rad MicroMat II (distributed by Cholestech as GDX) and the Axis-Shield Afinion, both of which utilize boronate affinity. The DCA 2000(R)+ utilizes combined immunoassay and general chemistry. These instruments cost $1000 to $3000 and require regular maintenance, making them appropriate only for high-volume physician offices. The newly improved A1CNow+ also utilizes combined immunoassay and general chemistry, but the small, inexpensive, disposable monitor can be used by patients as well as by health care professionals. The new version of A1CNow+ has improved performance through recent introduction of automated solid state chemistry manufacturing, improved fluidics and automated assembly of the test cartridge, error-correcting software, and unitary meter calibration with factory calibration directly to the NGSP reference standard.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA