1.
Mod Rheumatol ; 21(5): 514-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21331659

RESUMO

We report a patient with rheumatoid factor-positive polyarthritis-type juvenile idiopathic arthritis (JIA) in whom clinical remission was achieved within 10 months after the start of methotrexate (MTX) therapy, and systemic repair of bone erosion was noted 8 months after clinical remission. These results indicate that even in cases of active JIA with the development of bone erosion, continuation of MTX therapy after the achievement of clinical remission can improve the prognosis, including repair of bone destruction.


Assuntos
Antirreumáticos/uso terapêutico , Artrite Juvenil/tratamento farmacológico , Artrite Juvenil/fisiopatologia , Metotrexato/uso terapêutico , Osteogênese/efeitos dos fármacos , Regeneração/efeitos dos fármacos , Adolescente , Artrite Juvenil/diagnóstico por imagem , Feminino , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/efeitos dos fármacos , Articulações dos Dedos/fisiologia , Humanos , Radiografia , Indução de Remissão , Articulação do Dedo do Pé/diagnóstico por imagem , Articulação do Dedo do Pé/efeitos dos fármacos , Articulação do Dedo do Pé/fisiologia
2.
Biomaterials ; 27(8): 1327-32, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16213581

RESUMO

The biocompatibility and biodegradation of hydroxyapatite (HA)/poly(L-lactide) (PLLA) composite bone implant rods were studied using two types of HA particles as reinforcing fillers, uncalcined-HA (u-HA) or calcined-HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA were implanted into the distal femurs of 25 rabbits. Four of these rabbits lived for more than 5 years after implantation, with one living for 7 years 4 months. Samples were retrieved after the rabbits died naturally and specimens were examined by light microscopy and scanning electron microscopy (SEM). For u-HA/PLLA, the shrinkage of the rods progressed further after 4 years, and some were almost completely resorbed. We could not find traces of the rod in some sections from more than 6 years. Remodeled bone encircled the residual material, and trabecular bone bonded directly to the rod was found toward the center. For u-HA/PLLA 30%, results were similar to u-HA/PLLA 40%, and the cross-sectional area had decreased by 4.0% at over 7 years. Most of the PLLA had been released from the rods. Neither obvious osteolytic nor osteoarthritic changes were found after 4 years.


Assuntos
Substitutos Ósseos , Durapatita , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Poliésteres , Próteses e Implantes , Animais , Masculino , Coelhos , Fatores de Tempo
3.
J Biomed Mater Res B Appl Biomater ; 66(2): 539-47, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12861605

RESUMO

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.


Assuntos
Materiais Biocompatíveis/metabolismo , Fixação Interna de Fraturas/instrumentação , Hidroxiapatitas/metabolismo , Fixadores Internos , Poliésteres/metabolismo , Implantes Absorvíveis , Animais , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Fêmur/cirurgia , Fêmur/ultraestrutura , Masculino , Osseointegração , Coelhos , Radiografia