Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Arq Bras Cardiol ; 121(7): e20230585, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082573

RESUMO

BACKGROUND: Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). OBJECTIVE: This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. METHODS: A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. RESULTS: After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). CONCLUSION: As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Resultado do Tratamento , Adulto , Adolescente , Adulto Jovem , Fatores de Tempo , Criança , Ecocardiografia , Função Ventricular Direita/fisiologia , Volume Sistólico/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Período Pós-Operatório
2.
Radiographics ; 44(7): e230156, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38870043

RESUMO

Accurate evaluation of the mitral valve (MV) apparatus is essential for understanding the mechanisms of MV disease across various clinical scenarios. The mitral annulus (MA) is a complex and crucial structure that supports MV function; however, conventional imaging techniques have limitations in fully capturing the entirety of the MA. Moreover, recognizing annular changes might aid in identifying patients who may benefit from advanced cardiac imaging and interventions. Multimodality cardiovascular imaging plays a major role in the diagnosis, prognosis, and management of MV disease. Transthoracic echocardiography is the first-line modality for evaluation of the MA, but it has limitations. Cardiac MRI (CMR) has emerged as a robust imaging modality for assessing annular changes, with distinct advantages over other imaging techniques, including accurate flow and volumetric quantification and assessment of variations in the measurements and shape of the MA during the cardiac cycle. Mitral annular disjunction (MAD) is defined as atrial displacement of the hinge point of the MV annulus away from the ventricular myocardium, a condition that is now more frequently diagnosed and studied owing to recent technical advances in cardiac imaging. However, several unresolved issues regarding MAD, such as the functional significance of pathologic disjunction and how this disjunction advances in the clinical course, require further investigation. The authors review the role of CMR in the assessment of MA disease, with a focus on MAD and its functional implications in MV prolapse and mitral regurgitation. ©RSNA, 2024 Supplemental material is available for this article. See the invited commentary by Stojanovska and Fujikura in this issue.


Assuntos
Imageamento por Ressonância Magnética , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem
3.
Arq. bras. cardiol ; 121(7): e20230585, jun.2024. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1563937

RESUMO

Resumo Fundamento A regurgitação valvar pulmonar é uma importante complicação de longo prazo em pacientes com tetralogia de Fallot (TF). Objetivo O presente estudo tem como objetivo investigar os efeitos do implante valvar pulmonar (IVP) na anatomia e função do ventrículo direito (VD) e na evolução em longo prazo da prótese implantada em posição pulmonar. Métodos Uma análise de coorte retrospectiva e unicêntrica foi realizada em 56 pacientes consecutivos com TF submetidos a IVP. O estudo incluiu pacientes de ambos os gêneros, com idade ≥ 12 anos e compreendeu avaliação de dados clínicos e cirúrgicos, ressonância magnética cardiovascular pré e pós-operatória e dados ecocardiográficos obtidos mais de 1 ano após IVP. Resultados Após o IVP, houve uma diminuição significativa do volume sistólico final do VD indexado pela área de superfície corpórea (ASC), de 89 mL/ASC para 69 mL/ASC (p < 0,001) e do volume diastólico final indexado do VD, de 157 mL/ASC para 116 mL/ASC (p < 0,001). Além disso, houve aumento da fração de ejeção corrigida do VD [ FEVDc = fluxo pulmonar ajustado (fluxo pulmonar anterógrado − fluxo regurgitante) / volume diastólico final do VD ] de 23% para 35% (p < 0,001) e da fração de ejeção do ventrículo esquerdo de 58% para 60% (p = 0,008). No entanto, foi observado um aumento progressivo no gradiente de pico da válvula pulmonar ao longo do tempo, com 25% dos pacientes apresentando um gradiente superior a 60 mmHg. Próteses menores (tamanhos 19 a 23) foram associadas a um risco 4,3 vezes maior de gradiente > 60 mmHg em comparação com próteses maiores (tamanhos 25 a 27; p = 0,029; intervalo de confiança: 1,18 a 17,8). Conclusão Conforme esperado, o IVP demonstrou melhorias nos volumes e na função do VD. O acompanhamento e a vigilância a longo prazo são cruciais para avaliar a durabilidade da prótese e detectar potenciais complicações. O dimensionamento adequado das próteses é essencial para melhorar a longevidade da prótese.


Abstract Background Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). Objective This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. Methods A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. Results After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow − regurgitant flow) / R V end-diastolic volume] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). Conclusion As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.

6.
Autops Case Rep ; 13: e2023449, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034520

RESUMO

Giant cell arteritis (GCA) is a type of chronic vasculitis that affects medium and large-caliber arteries, frequently related to aortic involvement and, consequently, to aneurysm formation. However, associated valvulitis with giant cells is uncommon. We describe the case of a 50-year-old female patient with aortic aneurysm and valvular insufficiency, whose anatomopathological examination revealed giant-cell aortic valvulitis associated with giant cell aortitis.

7.
Ren Fail ; 45(1): 2224888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37350345

RESUMO

BACKGROUND: Candidates for transcatheter aortic valve implantation (TAVI) are currently evaluated using computed tomography angiography and invasive cardiac catheterization as an essential part of case selection and pre-procedure interventional planning. However, both imaging methods utilize iodinated agents, which may cause contrast-induced nephropathy, particularly in patients with baseline renal dysfunction. This study aimed to describe a zero-contrast imaging protocol for pre-TAVI evaluation in patients with advanced renal impairment. METHODS: The pre-TAVI zero-contrast scheme consisted of the following multi-modality combinations: (1) gadolinium-free magnetic resonance imaging (three-dimensional navigator-echo with electrocardiogram-gated steady-state free-precession series); (2) iodinated-free multislice computed tomography electrocardiogram-gated; (3) lower limb arterial duplex scan ultrasound; and (4) transesophageal echocardiography. Ultimately, TAVI was performed for those deemed good candidates, and contrast was allowed during the intervention; however, operators were strongly advised to utilize the least volume possible of iodinated agents. This pilot survey included ten patients with symptomatic aortic stenosis and renal dysfunction who underwent zero-contrast multi-modality imaging. RESULTS: All the patients ultimately underwent TAVI. The intervention was successful in all cases, without ≥ moderate residual aortic regurgitation, prosthesis embolization, annulus rupture, major vascular complications, stroke, or death during index hospitalization. The creatinine clearance remained stable throughout the observation period (baseline: 26.85 ± 12.55 mL/min; after multi-modality imaging: 26.76 ± 11.51 mL/min; post-TAVI at discharge: 29.84 ± 13.98 mL/min; p = 0.3 all). CONCLUSION: The proposed contrast-free imaging protocol appears to be a promising clinical tool for pre-TAVI evaluation in patients with severe renal dysfunction.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores , Cateterismo Cardíaco/métodos
10.
Autops. Case Rep ; 13: e2023449, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520268

RESUMO

ABSTRACT Giant cell arteritis (GCA) is a type of chronic vasculitis that affects medium and large-caliber arteries, frequently related to aortic involvement and, consequently, to aneurysm formation. However, associated valvulitis with giant cells is uncommon. We describe the case of a 50-year-old female patient with aortic aneurysm and valvular insufficiency, whose anatomopathological examination revealed giant-cell aortic valvulitis associated with giant cell aortitis.

12.
Radiol Bras ; 55(6): 373-379, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36514677

RESUMO

Aortic valve stenosis is the most common acquired valvular heart disease. Transcatheter aortic valve implantation, also known as transcatheter aortic valve replacement (TAVR), is an important treatment option for symptomatic aortic stenosis in patients at any level of surgical risk. The role of computed tomography angiography (CTA) has expanded considerably in recent years, and it has now become the imaging method of choice for the planning of TAVR. Therefore, radiologists should understand the main aspects of this imaging modality, including the appropriate technique and protocol to acquire reliable CTA images and to create a useful radiology report. The aim of this study was to review the most important aspects of CTA for TAVR planning.


A estenose da válvula aórtica é a doença cardíaca valvar adquirida mais comum. A substituição transcateter da válvula aórtica (TAVR), ou implante transcateter da válvula aórtica, é uma importante opção no tratamento da estenose aórtica sintomática, independente do risco cirúrgico do paciente. O papel da angiotomografia computadorizada cresceu consideravelmente nos últimos anos e tornou-se o método de escolha no planejamento de TAVR. Assim, o radiologista deve compreender os principais aspectos dessa modalidade, incluindo técnica e protocolo, a fim de adquirir imagens confiáveis e compor um relatório para a realização do procedimento. O objetivo deste ensaio é revisar os pontos mais importantes que precisam ser avaliados na angiotomografia no planejamento de TAVR.

13.
Radiol. bras ; 55(6): 373-379, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422519

RESUMO

Abstract Aortic valve stenosis is the most common acquired valvular heart disease. Transcatheter aortic valve implantation, also known as transcatheter aortic valve replacement (TAVR), is an important treatment option for symptomatic aortic stenosis in patients at any level of surgical risk. The role of computed tomography angiography (CTA) has expanded considerably in recent years, and it has now become the imaging method of choice for the planning of TAVR. Therefore, radiologists should understand the main aspects of this imaging modality, including the appropriate technique and protocol to acquire reliable CTA images and to create a useful radiology report. The aim of this study was to review the most important aspects of CTA for TAVR planning.


Resumo A estenose da válvula aórtica é a doença cardíaca valvar adquirida mais comum. A substituição transcateter da válvula aórtica (TAVR), ou implante transcateter da válvula aórtica, é uma importante opção no tratamento da estenose aórtica sintomática, independente do risco cirúrgico do paciente. O papel da angiotomografia computadorizada cresceu consideravelmente nos últimos anos e tornou-se o método de escolha no planejamento de TAVR. Assim, o radiologista deve compreender os principais aspectos dessa modalidade, incluindo técnica e protocolo, a fim de adquirir imagens confiáveis e compor um relatório para a realização do procedimento. O objetivo deste ensaio é revisar os pontos mais importantes que precisam ser avaliados na angiotomografia no planejamento de TAVR.

14.
Sci Rep ; 12(1): 15776, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36138087

RESUMO

Left ventricular hypertrophy is a risk factor for cardiovascular mortality in patients on peritoneal dialysis (PD). Because icodextrin has a greater ultrafiltration power compared with glucose-based solutions for long dwell, it could improve left ventricular mass by reducing fluid overload. This was a randomized clinical trial that included patients on PD recruited from 2 teaching hospitals, in Sao Paulo-Brazil. Patients were allocated to the control glucose group (GLU) or the intervention icodextrin (ICO) group. Clinical and cardiac magnetic resonance image (MRI) parameters were evaluated at baseline and 6 months after randomization. The primary outcome was the change in left ventricular mass adjusted by surface area (ΔLVMI), measured by cardiac MRI. A total of 22 patients completed the study (GLU, N = 12 and ICO, N = 10). Baseline characteristics such as age, sex, underlying disease, and time on dialysis were similar in both groups. At baseline, 17 patients (77.3%) presented with left ventricular hypertrophy with no difference between groups (p = 0.748). According to the total body water (TBW)/extracellular water (ECW) ratio, 36.8% and 80% of patients from GLU and ICO groups, respectively, were considered hypervolemic (p = 0.044). During follow-up, ΔLVMI was 3.9 g/m (- 10.7, 2.2) in GLU and 5.2 (- 26.8, 16.8) in ICO group (p = 0.651). ΔLVMI correlated with change in brain natriuretic peptide (r = 0.566, p = 0.044), which remained significant in a multiple regression analysis. The use of the icodextrin-based solution in prevalent patients on PD compared with a glucose-based solution was not able to improve LMV. A larger randomized trial with a longer follow-up period may be needed to show changes in LVM in this patient population.Trial registration: this study has been registered at ReBEC (Registro Brasileiro de Ensaios Clinicos) under the identification #RBR-2mzhmj2, available at: https://ensaiosclinicos.gov.br/pesquisador .


Assuntos
Soluções para Diálise , Icodextrina , Diálise Peritoneal , Brasil , Glucanos/uso terapêutico , Glucose/efeitos adversos , Glucose/uso terapêutico , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Icodextrina/uso terapêutico , Peptídeo Natriurético Encefálico , Diálise Peritoneal/métodos , Estudos Prospectivos , Diálise Renal
17.
Einstein (Sao Paulo) ; 18: eRC5876, 2020.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33111813

RESUMO

A male patient with flu-like symptoms and tomography and laboratory diagnosis of severe acute respiratory syndrome. He developed acute cardiac dysfunction during admission and was submitted to a cardiac magnetic resonance imaging examination, which confirmed acute myocarditis, indicating cardiac involvement by coronavirus disease 2019. A review and discussion about coronavirus disease 2019-related cardiac manifestations are reported, focusing on the imaging findings to make diagnosis.


Assuntos
Infecções por Coronavirus/complicações , Miocardite/virologia , Pneumonia Viral/complicações , Betacoronavirus , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino , Miocardite/diagnóstico por imagem , Pandemias , Pneumonia Viral/diagnóstico , SARS-CoV-2
20.
Cardiovasc Revasc Med ; 21(5): 640-646, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31501019

RESUMO

BACKGROUND/PURPOSE: This study sought to determine the diagnostic accuracy of 320-row computed tomography (320CT) for characterizing coronary atherosclerotic plaques in comparison with optical coherence tomography (OCT). METHODS/MATERIALS: From 32 patients, 42 coronary segments were evaluated and co-registered by both 320CT and OCT. 320CT vulnerable plaque characteristics included low attenuation plaque (LAP) (<30HU), napkin-ring sign (NRS), positive remodeling (PR) and spotty calcification (SC). The presence of macrophage, neovascularization and cholesterol crystals was also determined by OCT. RESULTS: Minimal lumen area was 2.78 ±â€¯1.23 mm by OCT and 3.29 ±â€¯1.49 mm by 320CT (p < 0.001). Noncalcified plaques were classified accordingly by both methods in 88.2% of the cases (p = 0.005). There was no association between any 320CT plaque type and OCT fibroatheroma (p = 0.62). The combination of 2 or more of the 320CT vulnerable plaque characteristics was associated with the presence of macrophage (74.2 vs. 25.8%; p = 0.034) and cholesterol crystals (85.7 vs. 14.3%; p = 0.04), but not with neovascularization (p = 0.65). The presence of all four characteristics demonstrated an accuracy of 75.1% for detecting OCT fibroatheroma. CONCLUSIONS: 320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all four 320CT vulnerable plaque characteristics provided the highest accuracy for detecting fibroatheromas. SUMMARY: 320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all 320CT vulnerable plaque characteristics (low attenuation plaque (<30HU), napkin-ring sign, positive remodeling and spotty calcification) provided the highest accuracy for detecting fibroatheromas compared to optical coherence tomography.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Placa Aterosclerótica , Tomografia de Coerência Óptica , Calcificação Vascular/diagnóstico por imagem , Idoso , Colesterol/análise , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/patologia , Vasos Coronários/química , Vasos Coronários/patologia , Cristalização , Feminino , Fibrose , Humanos , Macrófagos/patologia , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Calcificação Vascular/metabolismo , Calcificação Vascular/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA