Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 298
Filtrar
1.
J Nucl Cardiol ; 30(6): 2261-2265, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37917321
2.
J Nucl Cardiol ; 30(6): 2268, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37904064
3.
Heart Rhythm ; 20(6): 886-890, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907232

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) improve outcomes in patients with heart failure (HF) with left ventricular ejection fraction (LVEF) ≤35%. Less is known about whether outcomes varied between the 2 noninvasive imaging modalities used to estimate LVEF-2-dimensional echocardiography (2DE) and multigated acquisition radionuclide ventriculography (MUGA)-which use different principles (geometric vs count-based, respectively). OBJECTIVE: The purpose of this study was to examine whether the effect of ICD on mortality in patients with HF and LVEF ≤35% varied on the basis of LVEF measured by 2DE or MUGA. METHODS: Of the 2521 patients with HF with LVEF ≤35% in the Sudden Cardiac Death in Heart Failure Trial, 1676 (66%) were randomized to either placebo or ICD, of whom 1386 (83%) had LVEF measured by 2DE (n = 971) or MUGA (n = 415). Hazard ratios (HRs) and 97.5% confidence intervals (CIs) for mortality associated with ICD were estimated overall, checking for interaction, and within the 2 imaging subgroups. RESULTS: Of the 1386 patients in the present analysis, all-cause mortality occurred in 23.1% (160 of 692) and 29.7% (206 of 694) of patients randomized to ICD or placebo, respectively (HR 0.77; 97.5% CI 0.61-0.97), which is consistent with that in 1676 patients in the original report. HRs (97.5% CIs) for all-cause mortality in the 2DE and MUGA subgroups were 0.79 (0.60-1.04) and 0.72 (0.46-1.11), respectively (P = .693 for interaction). Similar associations were observed for cardiac and arrhythmic mortalities. CONCLUSION: We found no evidence that in patients with HF and LVEF ≤35%, the effect of ICD on mortality varied by the noninvasive imaging method used to measure LVEF.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Função Ventricular Esquerda , Volume Sistólico , Desfibriladores Implantáveis/efeitos adversos , Modelos de Riscos Proporcionais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia
4.
J Nucl Cardiol ; 30(2): 439-440, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36849636
5.
J Nucl Cardiol ; 30(1): 20-22, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36720751

RESUMO

"A quick glance at selected topics in this issue" aims to highlight contents of the Journal and provide a quick review to the readers.

8.
J Nucl Cardiol ; 30(1): 1-9, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36482238
9.
J Nucl Cardiol ; 29(6): 2807-2811, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36348247
10.
J Nucl Cardiol ; 29(6): 2812, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36322375
11.
J Nucl Cardiol ; 29(5): 2061-2063, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36104571

RESUMO

"A quick glance at selected topics in this issue" aims to highlight contents of the Journal and provide a quick review to the readers.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Humanos
12.
J Nucl Cardiol ; 29(4): 1487-1489, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35829953

RESUMO

"A quick glance at selected topics in this issue" aims to highlight contents of the Journal and provide a quick review to the readers.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Tomografia Computadorizada de Emissão de Fóton Único
14.
J Nucl Cardiol ; 29(4): 1753, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35610538
15.
J Nucl Cardiol ; 29(2): 392-394, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35288811

RESUMO

"A quick glance at selected topics in this issue" aims to highlight contents of the Journal and provide a quick review to the readers.


Assuntos
Medicina Nuclear , Humanos
16.
J Nucl Cardiol ; 29(2): 612-621, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-32754894

RESUMO

BACKGROUND: Assessment of quality of life in patients with stable angina and normal gated single-photon emission computed tomography myocardial perfusion imaging (MPI) remains undefined. Symptom evolution in response to imaging findings has important implications on further diagnostic testing and therapeutic interventions. METHODS: Prospective cohort study was conducted at the University of Alabama at Birmingham enrolling 87 adult participants with stable chest pain from the emergency room, hospital setting, and outpatient clinics. Patients underwent MPI with technetium-99m Sestamibi and had a normal study. Participants filled out Seattle Angina Questionnaires initially and at 3-month follow-up. RESULTS: Among the 87 participants (60 ± 12 years; 40% African American, 70% women, 29% diabetes), the mean score increased by an absolute value of 14.2 [95% CI 10.4-18.7, P < .001] in physical limitation, 23.2 [95% CI 17.1-29.4, P < .001] in angina stability, 10.9 [95% CI 7.6-14.1, P < .001] in angina frequency, and 20.6 [95% CI 16.5-24.7, P < .001] in disease perception. There was no significant change in the mean score of treatment satisfaction [- 1.4, 95% CI - 4.7 to 1.8, P = .38]. At 3-month follow-up, 28 of 87 participants (32%) were angina free. CONCLUSIONS: Patients with stable chest pain and normal MPI experience significant improvement in functional status, quality of life, and disease perception in the short term.


Assuntos
Angina Estável , Imagem de Perfusão do Miocárdio , Adulto , Angina Estável/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Feminino , Humanos , Masculino , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Prognóstico , Estudos Prospectivos , Purinas , Pirazóis , Qualidade de Vida , Cintilografia , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
18.
J Nucl Cardiol ; 29(3): 978-986, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33089878

RESUMO

BACKGROUND: An absent left ventricular ejection fraction (LVEF) reserve with vasodilator stress with PET cardiac imaging has been shown to provide significant independent and incremental value to the perfusion images for prediction of future cardiovascular adverse events. However, the prognostic value of LVEF reserve has not been well characterized with SPECT myocardial perfusion imaging (MPI). METHODS: We studied 858 consecutive patients with normal and abnormal perfusion pattern with regadenoson SPECT MPI. Change in LVEF was calculated as post-stress LVEF-rest LVEF. Absent LVEF reserve was defined as a drop in LVEF by 5% or more on the post-stress images. The primary outcome was a composite of cardiac death, non-fatal myocardial infarction and late coronary revascularization. RESULTS: An absent LVEF reserve was more common in patients with abnormal vs normal MPI (31% vs 19%, P = .001). During a median follow-up of 32 months, the primary outcome was experienced by 31% of the study population. An absent LVEF reserve was not associated with an increased risk of the primary outcome in patients with normal (hazard ratio 1.1, 95% CI .4-2.7, P = .8) or abnormal (.75, .56-1.00, P = .05) MPI. There was no significant correlation between extent of ischemia and post-stress change in LVEF (Pearson r = - .072, P = .07). CONCLUSIONS: In patients undergoing regadenoson SPECT MPI, absent LVEF reserve is not associated with worse cardiac outcomes. Thus, routine reporting of both post-stress and rest LVEF measurements in this setting may not be necessary.


Assuntos
Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Prognóstico , Purinas , Pirazóis , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda
19.
J Nucl Cardiol ; 29(6): 2896-2905, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34677806

RESUMO

BACKGROUND: SPECT myocardial perfusion imaging (MPI) provides an assessment of LV mechanical dyssynchrony (LVMD) which correlates with CVD outcomes in diverse populations including those awaiting renal transplant (RT). The current study examines the association of LVMD on pre-transplant MPI with long-term CVD mortality post RT. METHODS: We identified consecutive patients who underwent RT at the University of Alabama at Birmingham between 2008 and 2012 from our prospectively collected database. 675 patients in the database underwent MPI and had images amenable for phase analysis. A blinded investigator retrieved the studies and derived LVMD indices including histogram bandwidth (BW), standard deviation (SD), phase peak, phase skewness, and phase kurtosis. The primary outcome was CVD death after RT. RESULTS: The study cohort had a median age of 54 years, 56% were men, 43% had diabetes, and 7% had prior myocardial infarction. Patients were on dialysis for a median of 3.4 years prior to RT and 34% received living donor transplants. During a median follow-up time after RT of 4.7 years (IQR 3.5 to 6.3 years) 59 patients (9%) succumbed to CVD death. Patients with wider BW, wider SD, lower skewness, and lower kurtosis had an increased risk of CVD death. On multivariate adjustment, BW and skewness remained as independent predictors of CVD deaths. CONCLUSIONS: LVMD by phase analysis of gated SPECT MPI is associated with increased risk of CVD death after RT. This association is independent of demographics, comorbidities, and traditional findings on MPI and added incremental prognostic information. Assessment of LVMD should be considered for risk stratification in these patients.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Transplante de Rim , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Prognóstico , Imagem de Perfusão do Miocárdio/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA