Ann Intern Med ; 155(1): 33-8, 2011 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-21727291

RESUMO

BACKGROUND: A pocket mobile echocardiography (PME) device is commercially available for clinical use, but public data documenting its accuracy compared with standard transthoracic echocardiography (TTE) are not available. OBJECTIVE: To compare the accuracy of rapidly acquired PME images with those acquired by standard TTE. DESIGN: Cross-sectional study. At the time of referral for TTE, ultrasonographers acquired PME images first in 5 minutes or less. Ultrasonographers were not blinded to the clinical indication for imaging or to the PME image results when obtaining standard TTE images. Two experienced echocardiographers and 2 cardiology fellows who were blinded to the indication for the study and TTE results but not to the device source interpreted the PME images. SETTING: Scripps Clinic Torrey Pines and Scripps Green Hospital, La Jolla, California. PATIENTS: Convenience sample of 97 patients consecutively referred for echocardiography. MEASUREMENTS: Visualizability and accuracy (the sum of proportions of true-positive and true-negative readings and observer variability) for ejection fraction, wall-motion abnormalities, left ventricular end-diastolic dimension, inferior vena cava size, aortic and mitral valve pathology, and pericardial effusion. RESULTS: Physician-readers could visualize some but not all echocardiographic measurements obtained with the PME device in every patient (highest proportions were for ejection fraction and left ventricular end-diastolic dimension [95% each]; the lowest proportion was for inferior vena cava size [75%]). Accuracy also varied by measurement (aortic valve was 96% [highest] and inferior vena cava size was 78% [lowest]) and decreased when nonvisualizability was accounted for (aortic valve was 91% and inferior vena cava size was 58%). Observer agreement was fair to moderate for some measurements among less-experienced readers. LIMITATION: The study was conducted at a single setting, there was no formal estimate of accuracy given the small convenience sample of patients, and few abnormal echocardiographic measurements occurred. CONCLUSION: The rapid acquisition of images by skilled ultrasonographers who use PME yields accurate assessments of ejection fraction and some but not all cardiac structures in many patients. Further testing of the device in larger patient cohorts with diverse cardiac abnormalities and with untrained clinicians obtaining and interpreting images is required before wide dissemination of its use can be recommended. PRIMARY FUNDING SOURCE: National Institutes of Health.


Assuntos
Ecocardiografia/instrumentação , Ecocardiografia/métodos , Idoso , Idoso de 80 Anos ou mais , Cardiologia , Competência Clínica , Estudos Transversais , Ecocardiografia/normas , Feminino , Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Derrame Pericárdico/diagnóstico por imagem , Estetoscópios , Volume Sistólico , Veia Cava Inferior/diagnóstico por imagem
3.
Evolution ; 56(6): 1110-22, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12144013

RESUMO

Ciliates provide a powerful system to analyze the evolution of duplicated alpha-tubulin genes in the context of single-celled organisms. Genealogical analyses of ciliate alpha-tubulin sequences reveal five apparently recent gene duplications. Comparisons of paralogs in different ciliates implicate differing patterns of substitutions (e.g., ratios of replacement/synonymous nucleotides and radical/conservative amino acids) following duplication. Most substitutions between paralogs in Euplotes crassus, Halteria grandinella and Paramecium tetraurelia are synonymous. In contrast, alpha-tubulin paralogs within Stylonychia lemnae and Chilodonella uncinata are evolving at significantly different rates and have higher ratios of both replacement substitutions to synonymous substitutions and radical amino acid changes to conservative amino acid changes. Moreover, the amino acid substitutions in C. uncinata and S. lemnae paralogs are limited to short stretches that correspond to functionally important regions of the alpha-tubulin protein. The topology of ciliate alpha-tubulin genealogies are inconsistent with taxonomy based on morphology and other molecular markers, which may be due to taxonomic sampling, gene conversion, unequal rates of evolution, or asymmetric patterns of gene duplication and loss.


Assuntos
Cilióforos/genética , Evolução Molecular , Duplicação Gênica , Tubulina (Proteína)/genética , Sequência de Aminoácidos , Animais , Sequência de Bases , Clonagem Molecular , Variação Genética , Dados de Sequência Molecular , Filogenia , Alinhamento de Sequência , Homologia de Sequência de Aminoácidos , Homologia de Sequência do Ácido Nucleico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...