Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 384
Filtrar
1.
Vestn Oftalmol ; 140(2. Vyp. 2): 123-128, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739141

RESUMO

Effective and atraumatic removal of a soft lens nucleus requires different surgical techniques compared to phacoemulsification of a dense nucleus. PURPOSE: This study was conducted to develop a non-ultrasound technique for emulsification of a soft lens nucleus. MATERIAL AND METHODS: Fifty-seven patients (57 eyes) underwent surgery. In 23 cases, early or immature cataracts were detected, and in 34 cases, lens removal was performed for refractive purposes in high myopia and complex myopic astigmatism. Phacoemulsifier Centurion Vision System (Alcon Laboratories, Inc., USA) was used for the surgery. Aspiration of soft lens nucleus was done using a rotational technique. The following aspects were evaluated in the course of the surgery: the volume of the required irrigation solution, and the frequency needing to involve ultrasound for complete emulsification of the lens nucleus. Intraoperative and postoperative complications were also assessed. RESULTS: The surgery was uneventful in all cases. There were no violations of the integrity of capsulorhexis edge. The need for short pulses of minimal power ultrasound during the removal of the soft lens using this technique arose only in 11 (19.3%) cases. The effective ultrasound time was less than 1 second. The required volume of irrigation solution was 33.0 (24.0; 43.0) ml, which does not differ significantly from that in ultrasonic phacoemulsification. CONCLUSIONS: The use of modern phacoemulsifiers providing a high vacuum level allows successful removal of a soft lens without using ultrasound, which prevents its negative impact on the ocular tissues. The use of adequate surgical techniques, including the optimal direction of rotation of the lens nucleus in the rotational technique, improves the efficiency of soft lens nucleus removal.


Assuntos
Facoemulsificação , Humanos , Masculino , Feminino , Facoemulsificação/métodos , Pessoa de Meia-Idade , Catarata , Resultado do Tratamento , Núcleo do Cristalino/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Idoso
2.
Vestn Oftalmol ; 140(2. Vyp. 2): 129-135, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739142

RESUMO

The influence of various patterns of preliminary femtosecond laser-assisted fragmentation of the lens nucleus on the energy and hydrodynamic parameters of phacoemulsification remains insufficiently studied. PURPOSE: This study evaluates the influence of various patterns of preliminary femtosecond laser-assisted fragmentation of the lens nucleus on the energy, hydrodynamic parameters of phacoemulsification, and the degree of corneal endothelial cell loss. MATERIAL AND METHODS: Hybrid phacoemulsification was performed in 336 patients (336 eyes) with grade IV immature cataract according to the Buratto classification in three age-matched groups. Group 1 included 103 patients (103 eyes) who underwent hybrid phacoemulsification with preliminary femtosecond laser-assisted fragmentation of the nucleus with a «pizza¼ pattern (division of the nucleus with 10 radial cuts). Group 2 included 112 patients (112 eyes) who underwent femtosecond laser-assisted fragmentation of the nucleus with a «cylinders¼ pattern (division of the nucleus with 8 radial cuts in combination with 5 circular cuts). Group 3 included 121 patients (121 eyes) who underwent femtosecond laser-assisted fragmentation of the nucleus with a «grid¼ pattern (division of the nucleus with 8 radial cuts in combination with multiple mutually perpendicular cuts in the central zone in the form of a grid with a 0.5 mm cell). Effective ultrasound time and the volume of irrigation solution for emulsification of the lens nucleus fragments were determined during the operation. The loss of corneal endothelial cells was assessed 3 months after surgery. RESULTS: The minimum effective ultrasound time was noted after using the "grid" pattern - 4.05 (2.88; 4.74) s, which was significantly less than with the "cylinders" pattern - 4.97 (3.78; 5.88) s and the "pizza" pattern - 6.15 (4.52; 7.75) s (p<0.05). The effective ultrasound time when using the "cylinders" pattern was significantly less than with the "pizza" pattern (p<0.05). The volume of irrigation solution used for emulsification of the lens nucleus fragments was significantly less in the "grid" pattern - 41.5 (33.5; 49.5) ml compared to the "cylinders" patterns 58.5 (51.0; 66.0), p<0.05 and "pizza" pattern 75.0 (66.0; 83.5), p<0.01. The volume of irrigation solution when using the "cylinders" pattern was significantly less than when using the "pizza" pattern (p<0.05). The loss of corneal endothelial cells after using the "grid" pattern was 8.82 (7.59; 9.87)%, which was significantly less than after the "cylinders" patterns - 9.97 (8.81; 10.83)%, p<0.05 and "pizza" - 11.70 (10.62; 12.97)%, p<0.05. At the same time, the loss of endothelial cells after using the "cylinders" pattern was significantly less than after the "pizza" pattern (p<0.05). CONCLUSIONS: The choice of the optimal pattern of preliminary femtosecond laser-assisted fragmentation of the lens nucleus provides a significant decrease in the energy and hydrodynamic parameters of phacoemulsification and, accordingly, the loss of corneal endothelial cells.


Assuntos
Catarata , Hidrodinâmica , Terapia a Laser , Núcleo do Cristalino , Facoemulsificação , Humanos , Facoemulsificação/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Núcleo do Cristalino/cirurgia , Catarata/diagnóstico , Terapia a Laser/métodos , Resultado do Tratamento , Idoso , Acuidade Visual
3.
Vestn Oftalmol ; 140(2. Vyp. 2): 109-115, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739139

RESUMO

Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser. PURPOSE: This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation. MATERIAL AND METHODS: The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed. RESULTS: The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a "grid" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density. CONCLUSIONS: Femtosecond laser-assisted fragmentation of the lens nucleus with a "grid" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.


Assuntos
Facoemulsificação , Humanos , Adulto , Masculino , Feminino , Facoemulsificação/métodos , Terapia a Laser/métodos , Catarata , Resultado do Tratamento , Núcleo do Cristalino/cirurgia , Sucção/métodos , Acuidade Visual
4.
Heliyon ; 10(7): e28856, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596108

RESUMO

The existence of proliferating cells in the intact spinal cord, their distribution and phenotype, are well studied in rodents. A limited number of studies also address the proliferation after spinal cord injury, in non-human primates. However, a detailed description of the quantity, distribution and phenotype of proliferating cells at different anatomical levels of the intact adult non-human primate spinal cord is lacking at present. In the present study, we analyzed normal spinal cord tissues from adult macaque monkeys (Macaca fuscata), infused with Bromo-2'-deoxyuridine (BrdU), and euthanized at 2h, 2 weeks, 5 weeks and 10 weeks after BrdU. We found a significantly higher density of BrdU + cells in the gray matter of cervical segments as compared to thoracic or lumbar segments, and a significantly higher density of proliferating cells in the posterior as compared to the anterior horn of the gray matter. BrdU + cells exhibited phenotype of microglia or endothelial cells (∼50%) or astroglial and oligodendroglial cells (∼40%), including glial progenitor phenotypes marked by the transcription factors Sox9 and Sox10. BrdU + cells also co-expressed other transcription factors known for their involvement in embryonic development, including Emx2, Sox1, Sox2, Ngn1, Olig1, Olig2, Olig3. In the central canal, BrdU + cells were located along the dorso-ventral axis and co-labeled for the markers Vimentin and Nestin. These results reveal the extent of cellular plasticity in the spinal cord of non-human primates under normal conditions.

5.
Vestn Oftalmol ; 140(1): 65-70, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450468

RESUMO

Prevention and treatment of anterior capsular contraction syndrome (ACCS) is a relevant problem in cataract surgery. PURPOSE: The study was performed to develop a femtosecond laser-assisted technique for anterior capsulotomy in anterior capsular contraction syndrome and assess its preliminary results in preventing the progression of pathological changes in the capsular bag. MATERIAL AND METHODS: The examination and femtosecond laser-assisted treatment without additional surgical intervention was performed in 6 patients (6 eyes) aged 69 to 73 years with anterior capsular contraction syndrome. Femtosecond laser-assisted anterior capsulotomy was performed using the VICTUS system (Technolas Perfect Vision, Germany). Capsulotomy diameter was 4.0-4.5 mm, laser radiation energy - 9000 nJ, laser exposure depth 900-1000 µm. RESULTS: The diameter of the anterior capsulotomy before treatment was 2.85 mm [2.75; 2.93]. After 1 month, the diameter of the anterior capsular opening was 2.88 mm [2.78; 2.96] (p>0.05). One year after femtosecond laser intervention, the anterior capsulotomy opening was almost the same shape and diameter - 2.84 mm [2.74; 2.94] (p>0.05). CONCLUSION: Femtosecond laser-assisted circular capsulotomy is an effective and safe method for preventing the progression of anterior capsular contraction syndrome in the absence of severe IOL decentration and for maintaining the diameter of the anterior capsular opening of at least 2.5-3.0 mm.


Assuntos
Extração de Catarata , Oftalmologia , Exposição à Radiação , Humanos , Olho , Lasers
6.
Benef Microbes ; 15(2): 145-164, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38412868

RESUMO

COVID-19 is caused by an airborne virus, SARS-CoV-2. The upper respiratory tract (URT) is, therefore, the first system to endure the attack. Inhabited by an assemblage of microbial communities, a healthy URT wards off the invasion. However, once invaded, it becomes destabilised, which could be crucial to the establishment and progression of the infection. We examined 696 URT samples collected from 285 COVID-19 patients at three time-points throughout their hospital stay and 100 URT samples from 100 healthy controls. We used 16S ribosomal RNA sequencing to evaluate the abundance of various bacterial taxa, α-diversity, and ß-diversity of the URT microbiome. Ordinary least squares regression was used to establish associations between the variables, with age, sex, and antibiotics as covariates. The URT microbiome in the COVID-19 patients was distinctively different from that of healthy controls. In COVID-19 patients, the abundance of 16 genera was significantly reduced. A total of 47 genera were specific to patients, whereas only 2 were unique to controls. The URT samples collected at admission differed more from the control than from the samples collected at later stages of treatment. The following four genera originally depleted in the patients grew significantly by the end of treatment: Fusobacterium, Haemophilus, Neisseria, and Stenotrophomonas. Our findings strongly suggest that SARS-CoV-2 caused significant changes in the URT microbiome, including the emergence of numerous atypical taxa. These findings may indicate increased instability of the URT microbiome in COVID-19 patients. In the course of the treatment, the microbial composition of the URT of COVID-19 patients tended toward that of controls. These microbial changes may be interpreted as markers of recovery.


Assuntos
Bactérias , COVID-19 , Microbiota , RNA Ribossômico 16S , Sistema Respiratório , SARS-CoV-2 , Humanos , COVID-19/microbiologia , Masculino , Feminino , Pessoa de Meia-Idade , Bactérias/classificação , Bactérias/genética , Bactérias/isolamento & purificação , RNA Ribossômico 16S/genética , Idoso , SARS-CoV-2/genética , Sistema Respiratório/microbiologia , Sistema Respiratório/virologia , Adulto , Idoso de 80 Anos ou mais
7.
Front Aging Neurosci ; 15: 1273825, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37953886

RESUMO

Background: Cognitive impairment is an irreversible, aging-associated condition that robs people of their independence. The purpose of this study was to investigate possible causes of this condition and propose preventive options. Methods: We assessed cognitive status in long-living adults aged 90+ (n = 2,559) and performed a genome wide association study using two sets of variables: Mini-Mental State Examination scores as a continuous variable (linear regression) and cognitive status as a binary variable (> 24, no cognitive impairment; <10, impairment) (logistic regression). Results: Both variations yielded the same polymorphisms, including a well-known marker of dementia, rs429358in the APOE gene. Molecular dynamics simulations showed that this polymorphism leads to changes in the structure of alpha helices and the mobility of the lipid-binding domain in the APOE protein. Conclusion: These changes, along with higher LDL and total cholesterol levels, could be the mechanism underlying the development of cognitive impairment in older adults. However, this polymorphism is not the only determining factor in cognitive impairment. The polygenic risk score model included 45 polymorphisms (ROC AUC 69%), further confirming the multifactorial nature of this condition. Our findings, particularly the results of PRS modeling, could contribute to the development of early detection strategies for predisposition to cognitive impairment in older adults.

8.
Artigo em Russo | MEDLINE | ID: mdl-37490669

RESUMO

OBJECTIVE: To reveal the relationships between antipsychotic and anticholinergic drugs and cognitive functions in patients with schizophrenia. MATERIAL AND METHODS: The observational prospective study was conducted at the Bekhterev National Medical Center of Psychiatry and Neurology. The study involved 41 patients (22 men and 19 women) with paranoid schizophrenia, according to ICD 10 criteria, aged 30.12±8.24 years on stable antipsychotic monotherapy or in combination with anticholinergic drug (trihexiphenidyl). Cognitive functions were assessed using the «Brief Assessment of Cognitive Function in Patients with Schizophrenia¼ (BACS) scale, severity of mental state and extrapyramidal disturbances were measured using the «Positive and Negative Syndrome Scale (PANSS) and the Simpson-Angus Scale for Assessment of Extrapyramidal Side Effects (SAS). All examination procedures were performed twice at weeks 2 and 8 of therapy. Patients were divided into 2 groups according to the type of antipsychotic therapy. Twelve patients received first generation antipsychotics (FGAs) (group 1), 29 patients received second generation antipsychotics (SGAs) (group 2). RESULTS: Patients receiving SGAs had a significant decrease in the overall SAS score at week 8 of therapy compared with data at week 2, and there was an improvement in cognitive function, unlike patients receiving FGAs. There were also changes on BACS tests the digit sequencing (V=51.5, p=0.007), token motor task (V=75.5, p=0.007) and Tower of London (V=52, p=0.027) only in patients of group 2. CONCLUSION: The improved tolerance to the drug, as well as cognitive measures, was shown in patients taking SGAs by week 8. Our study confirms the importance of adhering to the minimum effective dose of antipsychotic drugs for the treatment of schizophrenia to prevent cognitive impairment, and to give preference to SGAs in the choice of treatment.


Assuntos
Antipsicóticos , Feminino , Humanos , Masculino , Antipsicóticos/efeitos adversos , Cognição , Quimioterapia Combinada , Estudos Prospectivos , Esquizofrenia Paranoide/tratamento farmacológico
9.
Vestn Oftalmol ; 139(3. Vyp. 2): 21-27, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37144365

RESUMO

The article presents authors' original methods of phaco surgery that can be used in disorders of the capsular-zonular apparatus of the lens. The cataract surgery techniques for lens subluxation developed and introduced into clinical practice allow using the most physiologically correct intracapsular intraocular lens (IOL) fixation in the vast majority of cases. The introduction of femtosecond laser at key stages of phacoemulsification in complicated clinical situations reduces the dependence of the results on the human factor and allows performing removal of complicated cataracts at a qualitatively new level.


Assuntos
Extração de Catarata , Catarata , Cristalino , Lentes Intraoculares , Facoemulsificação , Humanos , Cristalino/cirurgia , Extração de Catarata/efeitos adversos , Extração de Catarata/métodos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Implante de Lente Intraocular/métodos , Catarata/complicações , Catarata/diagnóstico
10.
Vestn Oftalmol ; 139(2): 89-94, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37067937

RESUMO

Anterior capsule contraction syndrome is a specific complication of continuous circular capsulorhexis in various phacoemulsification techniques. Surgical, laser and combined methods have been proposed for its treatment. All approaches in the treatment of anterior capsule contraction syndrome have some advantages, as well as certain problems and difficulties. This review presents the current state of this problem of cataract surgery and possible prospects for improving the treatment.


Assuntos
Extração de Catarata , Terapia a Laser , Facoemulsificação , Humanos , Capsulorrexe/efeitos adversos , Capsulorrexe/métodos , Facoemulsificação/efeitos adversos , Implante de Lente Intraocular , Terapia a Laser/métodos
11.
Mar Pollut Bull ; 187: 114576, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36640501

RESUMO

Twenty-seven sediment samples from the eastern Laptev Sea were analyzed for mercury and total organic carbon as well as grain-size distribution. The average total mercury (THg) concentrations in sediments are 29 ± 14 µg kg-1. A significant correlation of THg content with total organic carbon and clay and silt fractions was shown. The 210Pb-dated sediment core was used to evaluate the contamination degree and flux of THg in sediments from the eastern Laptev Sea. The average sedimentation rate for the all dated intervals was 0.17 cm/year. The THg flux increased from 20 to 28 µg/m2/year in the period of 1892-1950 to 53-59 µg/m2/year in the modern period of 2011-2015. According to various indices, the ecological risk from THg in studied sediment was low.


Assuntos
Mercúrio , Poluentes Químicos da Água , Mercúrio/análise , Poluentes Químicos da Água/análise , Sedimentos Geológicos/química , Carbono , Monitoramento Ambiental
12.
J Autism Dev Disord ; 53(10): 4090-4099, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35397709

RESUMO

We aimed to screen children aged 18-48 months in the general population of nine Russian regions for risk of mental, behavioral and developmental disorders (MBDDs) including autism spectrum disorders (ASD) using an original screening tool. The prevalence of the risk for MBDDs is 1307:10,000 (13.07%), the prevalence of clinically verified cases of MBDDs is 151:10,000 (1.51%), whereas the prevalence of ASD among them is 18:10,000 (0.18%). Basing on our results, the screening procedures are already integrated into the Russian primary care system since the end of 2019. Screening of the risk for MBDDs including ASD in Russia among children in the general pediatric population is a promising area of preventive medicine.


Assuntos
Transtorno do Espectro Autista , Transtorno Autístico , Criança , Humanos , Pré-Escolar , Transtorno do Espectro Autista/diagnóstico , Transtorno do Espectro Autista/epidemiologia , Deficiências do Desenvolvimento/diagnóstico , Deficiências do Desenvolvimento/epidemiologia , Federação Russa/epidemiologia , Prevalência , Programas de Rastreamento
13.
Phys Rev Lett ; 129(17): 173202, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36332250

RESUMO

High-harmonic generation is typically thought of as a sub-laser-cycle process, with the electron's excursion in the continuum lasting a fraction of the optical cycle. However, it was recently suggested that long-lived Rydberg states can play a particularly important role in high harmonic generation by atoms driven by the combination of the counterrotating circularly polarized fundamental light field and its second harmonic. Here we report direct experimental evidence of very long and stable Rydberg trajectories contributing to high-harmonic generation in such fields. We track their dynamics inside the laser pulse using the spin-orbit evolution in the ionic core, utilizing the spin-orbit Larmor clock. We confirm their effect on harmonic emission both via microscopic simulations and by showing how this radiation can lead to a well-collimated macroscopic far-field signal. Our observations contrast sharply with the general view that long-lived Rydberg orbits should generate negligible contribution to the macroscopic far-field high harmonic response of the medium.

14.
Vestn Oftalmol ; 138(5. Vyp. 2): 156-161, 2022.
Artigo em Russo | MEDLINE | ID: mdl-36287150

RESUMO

For the moment, the refractive outcomes of out-of-the-bag intraocular lens (IOL) implantation remain insufficiently studied. PURPOSE: To study and compare the refractive outcomes of retropupillary implantation of an iris-claw lens and transscleral suture fixation of IOL in complicated phacoemulsification. MATERIAL AND METHODS: The study included 70 patients (73 eyes) after complicated phacoemulsification in combination with grade 2 lens subluxation. The first group included 36 patients (39 eyes) who underwent complicated phacoemulsification using torsional ultrasound and retropupillary implantation of an iris-claw lens. The second group included 34 patients (34 eyes) after complicated phacoemulsification using torsional ultrasound and transscleral suture fixation of an elastic hydrophobic IOL. In the postoperative period we performed a comparative evaluation of uncorrected visual acuity and best corrected visual acuity, the average absolute error of IOL optical power calculation, the precision of postoperative refraction within ±0.5 diopters, the degree of induced astigmatism, and the tilt of the IOL. RESULTS: At three months after surgery uncorrected visual acuity of 0.8-1.0 was achieved in 33.3% of cases in the first group and 17.6% in the second group, the average absolute error of IOL optical power calculation was 0.34±0.08 diopters in the first group and 0.63±0.19 diopters in the second group, the precision of postoperative refraction within ±0.5 diopters was 94.9% in the first group and 85.3% in the second group, the tilt of the IOL was 0.69±0.21° in the first group and 3.19±0.97° in the second group (p<0.05). There were no significant differences in best corrected visual acuity and the degree of induced astigmatism 3 months after surgery. CONCLUSION: Implantation of an iris-claw lens in the course of complicated phacoemulsification in lens subluxation significantly improves refractive outcomes of the implantation in comparison with transscleral IOL fixation.


Assuntos
Astigmatismo , Subluxação do Cristalino , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Astigmatismo/cirurgia , Facoemulsificação/efeitos adversos , Refração Ocular , Subluxação do Cristalino/cirurgia
15.
Mar Pollut Bull ; 180: 113797, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35640381

RESUMO

Sediment samples from 53 stations of the southwestern Chukchi sea were investigated to the spatial distributions and assess the state of trace metals contamination using ecological indices. The mean concentrations (mg kg-1) in sediments were: Cr (70.5), Ni (41.0), Cu (16.5), Zn (82.7), As (15.90), Cd (0.27), Pb (15.96), Hg (32.0 µg kg-1). The spatial distribution pattern of trace metals was similar with maximum values in the northern of the Chukchi Sea in the outer shelf sediments, while the high values of Cd were noted at stations located in the southern part of the sea where a strong influence of the Pacific waters penetrating through the Bering Strait. The ecological indices indicated no signs of anthropogenic pollution in the study sediments of the Chukchi Sea. Received data are of value for detecting and tracking future chemical changes in the sediments of the Chukchi sea, particularly in light of environmental changes.


Assuntos
Metais Pesados , Oligoelementos , Poluentes Químicos da Água , Cádmio , China , Monitoramento Ambiental , Sedimentos Geológicos , Metais Pesados/análise , Medição de Risco , Poluentes Químicos da Água/análise
16.
Sovrem Tekhnologii Med ; 14(6): 15-23, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37181287

RESUMO

Multigene testing using NGS (next-generation sequencing) provides a large amount of information and can detect multiple molecular alterations. Subsequent clinical interpretation is a time-consuming process necessary to select a treatment strategy. Existing databases often contain inconsistent information and are not regularly updated. The use of ESCAT levels of evidence requires a deep understanding of the nature of alterations and does not answer the question of which therapy option to select when multiple biomarkers with the same level of evidence are detected. To address these issues, we created the Clinical Relevance of Alterations in Cancer (CRAC) database on the relevance of detected alterations in specific genes, which are often analyzed as part of NGS panels. The team of oncologists and biologists assigned a CRAC score from 1 to 10 to each biomarker (a type of genomic alteration characteristic of specific genes) for 15 malignancies; an average score was entered into the database. CRAC scores are a numerical reflection of the following factors: therapy availability and the prospects of drug treatment with experimental drugs for patients with a particular type of tumor. A total of 134 genes and 15 of the most common tumor types have been selected for CRAC. The biomarker-nosology associations with CRAC scores in the range of 1-3 are the most frequent (n=2719 out of 3495; 77.8%), the least frequent ones (n=52 out of 3495; 1.5%) are with the highest CRAC scores 9 and 10. To estimate the practical effectiveness of the CRAC database, 208 reports on comprehensive molecular profiling were retrospectively analyzed; the applicability of CRAC was compared with the ESCAT level of evidence system. The highest CRAC scores corresponded to the ESCAT maximum levels of evidence: the range of scores 8-10 corresponded to evidence levels I and II. No biomarker within the same level of evidence was represented by the same CRAC score; the largest range of CRAC scores was observed for biomarkers of levels evidence IIIA and IV - from 2 to 10 and from 1 to 9, respectively. The use of CRAC scores allowed to identify additional 95 alterations with CRAC scores of 1-5 in the studied patients. The developed database is available at: https://crac.oncoatlas.ru/.


Assuntos
Relevância Clínica , Neoplasias , Humanos , Estudos Retrospectivos , Medicina de Precisão , Neoplasias/tratamento farmacológico , Neoplasias/genética , Neoplasias/patologia , Bases de Conhecimento
17.
Vestn Oftalmol ; 137(5. Vyp. 2): 209-216, 2021.
Artigo em Russo | MEDLINE | ID: mdl-34669329

RESUMO

Studying the modern capabilities of femtosecond laser in the treatment of complicated cataracts is a topical problem in cataract surgery. PURPOSE: To develop a technique for femtosecond laser-assisted phacoemulsification of hypermature cataract in patients with degree I-II lens subluxation. MATERIAL AND METHODS: Phacoemulsification of hypermature cataract with comorbid lens subluxation was performed in 78 patients (78 eyes) divided into two groups. In the 1st group (45 eyes), capsulorhexis was performed using a femtosecond laser. Patients of the 2nd group (33 eyes) underwent manual capsulorhexis. The study assessed the possible frequency of using modern methods of capsular bag fixation and complete all-in-the-bag intraocular lens (IOL) implantation, as well as the number of various types of intraoperative capsular bag ruptures. RESULTS: In all patients of the 1st group, capsulorhexis of the correct round shape and the required diameter was achieved, allowing the use of modern methods of fixation and centering of the capsular bag. Insignificant tear of the edge of the capsulorhexis after IOL implantation was detected only in 1 (2.2%) patient. Vitreous prolapse was noted in 1 (2.2%) case. In the 2nd group, manual technique resulted in oval capsulorhexis with a smooth edge, allowing the use of modern methods of fixation of the capsular bag only in 7 (21.2%) cases. Vitreous prolapse was noted in 4 (12.1%) cases. The complete in-the-bag IOL implantation was possible in 44 (97.8%) cases in the 1st group and only in 7 (21.2%) in the 2nd group. CONCLUSION: The use of femtosecond laser in patients with hypermature cataract and lens subluxation allows achieving capsulorhexis of ideally round shape with a smooth edge. This creates the necessary conditions for the use of modern methods of fixation of the capsular bag and provides the possibility of complete all-in-the-bag IOL implantation.


Assuntos
Catarata , Subluxação do Cristalino , Lentes Intraoculares , Facoemulsificação , Capsulorrexe , Catarata/complicações , Catarata/diagnóstico , Humanos , Lasers , Implante de Lente Intraocular , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/etiologia , Subluxação do Cristalino/cirurgia , Facoemulsificação/efeitos adversos
18.
Artigo em Russo | MEDLINE | ID: mdl-34481437

RESUMO

OBJECTIVE: To investigate whether visual processing abnormalities are the result of visual dysfunction involving cognitive impairment or independent abnormalities and to identify the relationship of visual impairments with cognitive functions and severity of psychopathological symptoms. MATERIAL AND METHODS: We compared results of visual size perception and actions on objects (motor assessment) in patients with schizophrenia (n=37), including patients with non-resistant schizophrenia (n=19) and healthy individuals (n=20). Cognitive impairments were assessed with BACS. Severity of schizophrenia symptoms was assessed with PANSS. RESULTS: The error in the visual size perception test was smaller in healthy controls compared with non-resistant patients (p<0.03). There are no significant differences between non-resistant patients and other groups. Also, there are no significant differences in motor assessment between healthy controls and patients with schizophrenia. In the visual size perception test, the amount of error correlates with cognitive impairments (r= -0.84, p<0.001), and the severity of psychotic symptoms on PANSS (r=0.55, p<0.05). CONCLUSION: Changes in visual threshold in patients with schizophrenia are correlated with cognitive dysfunction and reflect dysfunction in the parvocellular system.


Assuntos
Transtornos Cognitivos , Disfunção Cognitiva , Esquizofrenia , Cognição , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/etiologia , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/etiologia , Humanos , Testes Neuropsicológicos , Esquizofrenia/complicações
19.
Zh Nevrol Psikhiatr Im S S Korsakova ; 121(5. Vyp. 2): 91-98, 2021.
Artigo em Russo | MEDLINE | ID: mdl-34405663

RESUMO

The review presents information on the most effective current non-drug methods of treatment of depression used in practice. A review of publications in PubMed and PsycINFO and Cochrane Library over the past 10 years was conducted. Non-drug biological therapies demonstrate high efficacy in the reduction of depressive symptoms in patients with recurrent depressive disorder. The use of non-drug therapy does not preclude the continuation of pharmacological therapy. In order to choose an optimal method of treatment, the psychophysical state of a patient, severity of depressive symptoms, response to drug therapy, and possibility of prescribing pharmacological therapy should be taken into account, and the principles of evidence-based medicine should be taken into consideration when making a decision.


Assuntos
Depressão , Estimulação Magnética Transcraniana , Depressão/tratamento farmacológico , Humanos , Resultado do Tratamento
20.
Artigo em Russo | MEDLINE | ID: mdl-34283524

RESUMO

OBJECTIVE: To develop clinical and social models and management routes for patients with autism spectrum disorders (ASD). MATERIAL AND METHODS: A clinical follow-up study was performed for 254 patients, aged 4-17 years (average age 7.3 years), who represented the main forms of ASD. Psychopathological, clinical-follow-up, psychological and statistical methods were used. RESULTS AND CONCLUSION: Five management models for patients with different forms of ASD are described; differentiation of routes for interagency monitoring of patients is proposed. The effectiveness of the integrated use of drug and non-drug therapeutic approaches for the management of patients with ASD in the clinical-age aspect is shown. Timely diagnosis of ASD makes it possible to develop differentiated routes of patient management within the framework of interdepartmental interaction and achieve positive results in the clinical and age aspect.


Assuntos
Transtorno do Espectro Autista , Transtorno do Espectro Autista/diagnóstico , Transtorno do Espectro Autista/terapia , Criança , Seguimentos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...