Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 88: 242-249, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34311162

RESUMO

PURPOSE: To assess if single shot acquisitions with solid-state dosimeters as well as Robson's method could replace ionization chambers for tube output and HVL measurements, saving medical physicists time. MATERIAL AND METHODS: The energy responses of 4 solid-state dosimeters with automatic calculation of HVL were compared to ionization chamber measurements. Five anode/filter combinations were tested: Mo/Mo, Mo/Rh, Rh/Rh, W/Rh and W/Ag, from 24kVp to 35kVp. Tube output was measured free in air. HVL was measured using the solid-state dosimeters (single-shot acquisition), then manually with aluminum sheets and finally using the parametrization method of Robson. RESULTS: Deviations in tube output and HVL related to energy response in SSD were small in the 25-32 kVp range, and for tube output typically within 3%. Extrapolation using the Robson parametrization was within 5%, except for one device and for all W/Rh. Deviations of the HVL using the single shot approach were within 10% of the gold standard data. Larger deviations were found at the extreme tube voltages of 24kVp and 35kVp (maximum of 24%). CONCLUSION: With the assumption that deviations in tube output of 5% and for HVL of 10% are acceptable, all tested solid state dosimeters met this criterion in the tube voltage range of 26kVp to 32kVp. Robson's method worked well for the spectra for which the method was developed, making both alternative approaches trustworthy for routine quality assurance purposes.


Assuntos
Mamografia , Dosímetros de Radiação , Fenômenos Físicos , Doses de Radiação , Raios X
2.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22940731

RESUMO

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Assuntos
Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Pediatria/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , África/epidemiologia , Ásia/epidemiologia , Europa (Continente)/epidemiologia , Pesquisas sobre Atenção à Saúde , Humanos , América Latina/epidemiologia , Doses de Radiação
3.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528891

RESUMO

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Assuntos
Padrões de Prática Médica/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , África , Ásia , Criança , Pré-Escolar , Europa (Continente) , Humanos , Lactente , Recém-Nascido , Agências Internacionais , América Latina , Doses de Radiação , Proteção Radiológica , Inquéritos e Questionários
4.
Radiat Prot Dosimetry ; 149(4): 454-63, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21775317

RESUMO

It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.


Assuntos
Vértebras Lombares/efeitos da radiação , Doses de Radiação , Monitoramento de Radiação/métodos , Vértebras Torácicas/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Coleta de Dados , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Montenegro , Radiografia/métodos , Radiografia Torácica , Valores de Referência
5.
Eur J Radiol ; 79(2): e70-3, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21507590

RESUMO

The purpose of this work was to investigate status of imaging technology and practice in five countries in Eastern-European region and evaluate the impact of IAEA projects on radiation protection of patients. Information collected using standardized IAEA protocol included status of technology, practices and patient dose levels in interventional procedure, radiography, mammography and computed tomography (CT). In spite of increased number of digital units, single phase generators or units older than 30 year are still in use. Examples of obsolete practice such as using fluoroscopy for positioning, photofluorography, chest fluoroscopy and soft-beam technique for chest radiography are also in use. Modern multi-slice CT or digital mammography units are available; however, there is lack of adequate radiation protection and medical physics support in hospitals. Information on patient doses in interventional procedures, conventional radiography, mammography and CT was collected to have baseline data and corrective measures were proposed with appropriate follow up actions taken.


Assuntos
Diagnóstico por Imagem , Controle de Qualidade , Proteção Radiológica/normas , Adulto , Criança , Europa Oriental , Feminino , Fluoroscopia , Humanos , Masculino , Mamografia , Posicionamento do Paciente , Estudos Prospectivos , Doses de Radiação , Radiometria/métodos , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...