Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Kyobu Geka ; 74(8): 627-630, 2021 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-34334608

RESUMO

Bronchial artery aneurysm (BAA) is a rare disease, for which early treatment is recommended due to the risk of rupture often resulting in severe consequences. We report a case of successful treatment of an asymptomatic BAA by selective branch embolization combined with thoracic endovascular aortic repair (TEVAR). A 68-year-old man was accidentally found to have a bronchial artery aneurysm by computed tomography. The distance from the origin of the bronchial artery to the aneurysm was only 6 mm, at which branches were found. The BAA was completely excluded by selective branch coil embolization and deployment of a thoracic stent graft to cover the orifice of the BAA. Angiography confirmed that there was no endoleak. Selective branch embolization of BAA combined with TEVAR is effective to completely occlude the blood stream to BAA.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Artérias Brônquicas/diagnóstico por imagem , Humanos , Masculino , Stents , Resultado do Tratamento
2.
Gen Thorac Cardiovasc Surg ; 69(5): 906-908, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33608837

RESUMO

Here, we report our unique "non-pledget commissural suture technique" to avoid complete atrioventricular block during surgical aortic valve replacement, whereby all commissural stiches are made in a figure-of-eight fashion without a pledget. Then, standard stiches in a non-everting fashion are made using pledget sutures and a prosthetic valve is implanted at the supra-annular position. Among 152 evaluated patients, only five patients experienced complications, including three left bundle branch blocks, one postoperative pacemaker implantation, and one moderate paravalvular leak. Based on the high success rate, our technique may be a reasonable alternative for surgical aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/prevenção & controle , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Técnicas de Sutura , Resultado do Tratamento
3.
J Surg Case Rep ; 2020(9): rjaa333, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32968478

RESUMO

A myxoma is one of the most common tumors in cardiac surgery, with most of them originating from the left or right atrial walls and causing embolic complications. An 84-year-old woman was referred to our institution after echocardiography showed an interatrial septum tumor that was presumed to be a thrombus; however, postoperative pathological examination revealed it to be a cardiac myxoma. This atypical myxoma was covered with a solid capsule containing connective tissue and substantial calcifications, which had made it difficult to establish a diagnosis of myxoma.

4.
Ann Thorac Surg ; 108(4): e273-e274, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31233719

RESUMO

Prosthetic valve removal for reoperative valve replacement is time consuming and has a risk of damage to the heart because of severe adhesions. Prosthetic valves can be removed quickly, easily, and safely by using an ultrasonic scalpel (Harmonic Scalpel, Ethicon Endo-Surgery, Cincinnati, OH). The space between the prosthesis and the native annulus was carefully dissected using Harmonic Synergy blades connected to an Ethicon Gen11 Generator at energy level 5. The average time for prosthetic valve removal using an ultrasonic scalpel was 6 minutes 11 seconds. No patient required new permanent pacemaker implantation.


Assuntos
Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos Ultrassônicos/instrumentação , Remoção de Dispositivo/instrumentação , Humanos , Reoperação
6.
Interact Cardiovasc Thorac Surg ; 23(4): 599-607, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27341829

RESUMO

OBJECTIVES: Heart valve replacement with a bileaflet mechanical valve is a well-established procedure. However, the long-term results of valve replacement using the bileaflet mechanical valve remain unclear, especially for follow-up periods over 30 years. Additionally, it is important to identify predictors of long-term mortality and valve-related events. METHODS: We performed a retrospective cohort analysis of 2727 patients (mean ± standard deviation age, 52.8 ± 1.6 years) who underwent valve replacement with a St. Jude Medical valve at our institute from 1978 to 2012. Data were collected using a questionnaire and chart review or physician contact. The cohort included 950 aortic valve replacements (AVRs), 1255 mitral valve replacements (MVRs) and 522 double valve replacements (DVRs). Follow-up was 91% complete, and the analysis included a total of 39 187 patient-years. RESULTS: Operative mortality rates were 2.3% for AVR, 2.2% for MVR and 3.6% for DVR. The 30-year survival rate (actuarial method) was 38.0% (AVR, 44.5%; MVR, 34.9%; and DVR, 37.5%). The 30-year rates of freedom from valve-related mortality, thromboembolic events and bleeding events were 86.3% (AVR, 88.6%; MVR, 85.4%; and DVR, 84.3%), 83.5% (AVR, 89.8%; MVR, 80.0%; and DVR, 81.4%) and 91.5% (AVR, 94.4%; MVR, 90.1%; and DVR, 90.2%), respectively. The incidence rates of valve-related morbidity, thromboembolic events and bleeding events were significantly higher among patients with MVR and DVR than among those with AVR. Significant risk factors for late death and other late events included male sex, age >65 years and atrial fibrillation. CONCLUSIONS: Low late mortality and a low incidence of valve-related events can be achieved for at least 30 years using mechanical bileaflet valve replacement. Persistent atrial fibrillation is a significant risk factor for morbidity and mortality.


Assuntos
Previsões , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Reimplante/métodos , Medição de Risco/métodos , Idoso , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Inquéritos e Questionários , Taxa de Sobrevida/tendências
7.
Heart Vessels ; 31(5): 819-21, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25633055

RESUMO

Left atrial dissection (LAD) is a rare complication and is defined as a gap from the mitral or tricuspid annular area to the interatrial septum or left atrial wall. Because of its low incidence, this entity is not fully understood. LAD is related to mitral valve surgery as well as coronary artery disease, arrhythmia, trauma, and tumors, and occurs spontaneously. Transesophageal echocardiography is the most useful diagnostic modality for LAD, but multimodality investigation supports accurate diagnosis. We experienced a case of LAD related to retrograde cardioplegia cannula insertion which was treated successfully with internal drainage.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Parada Cardíaca Induzida/efeitos adversos , Parada Cardíaca Induzida/instrumentação , Átrios do Coração/lesões , Traumatismos Cardíacos/etiologia , Insuficiência da Valva Mitral/terapia , Drenagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Gen Thorac Cardiovasc Surg ; 63(8): 434-45, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26003839

RESUMO

Left atrial (LA) dissection is a rare complication and is defined as a gap from the mitral or tricuspid annular area to the interatrial septum or left atrial wall. Because of its low incidence, this entity is not fully understood. LA dissection is related to mitral valve surgery as well as coronary artery disease, arrhythmia, trauma, tumor, and spontaneous occurrence. Transesophageal echocardiography is the most useful diagnostic modality for LA dissection, but multimodality investigation supports accurate diagnosis. There are two treatment options for LA dissection: surgical repair and close observation. Surgical repair involves entry closure and internal drainage. The indication for surgery should be based on the clinical presentation.


Assuntos
Dissecção Aórtica/terapia , Aneurisma Cardíaco/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Septo Interatrial/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Feminino , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Átrios do Coração/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
9.
Kyobu Geka ; 67(6): 505-7, 2014 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-24917411

RESUMO

A 55-year-old gentleman diagnosed with severe aortic insufficiency and annuloaortic ectasia underwent modified Bentall procedure using mechanical valve. Anticoagulation therapy with warfarin was introduced after surgery, but sufficient anticoagulation effect was not achieved with a large amount of dosage. After discontinuing the use of the Clostridium butyricum preparation on postoperative day 29, sufficient anticoagulationt effect was obtained within several days. Clostridium butyricum might change the vitamin K production in the intestinal bacterial flora and attenuated the anticoagulation effect of warfarin.


Assuntos
Anticoagulantes/farmacologia , Produtos Biológicos/efeitos adversos , Clostridium butyricum , Varfarina/antagonistas & inibidores , Insuficiência da Valva Aórtica/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório
10.
Gen Thorac Cardiovasc Surg ; 60(6): 391-3, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22566248

RESUMO

A 59-year-old man, who had been treated using the infarction exclusion technique for inferior post-infarction ventricular septal rupture (VSR) 4 months previously, was readmitted because of deterioration of mitral valve regurgitation, residual shunt, and progression of pulmonary hypertension. We performed mitral valve replacement via the transseptal approach, patch closure of the defect via the transtricuspid approach, and tricuspid valve annuloplasty. The post-operative course was uneventful. The transtricuspid approach is useful in redo surgery for post-infarction VSR.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Pericárdio/transplante , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Ruptura do Septo Ventricular/cirurgia , Cateterismo Cardíaco , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Tomografia Computadorizada Multidetectores , Reoperação , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Ruptura do Septo Ventricular/diagnóstico , Ruptura do Septo Ventricular/etiologia
11.
Interact Cardiovasc Thorac Surg ; 12(1): 82-3, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21098422

RESUMO

The congenital bicuspid aortic valve (BAV) is recognized as a cause of acute aortic dissection (AAD) and also as a risk factor for infective endocarditis (IE) especially ring abscess. We experienced a case of all these combined and operated emergently. A 59-year-old man was transferred to us, and emergent operation was indicated for AAD and aortic stenosis (AS) due to BAV. However, he was strongly suspected of also having IE during the operation and the procedure was changed to a modified Bentall's method. The diagnosis was confirmed by pathological examination postoperatively. He recovered well after postoperative antimicrobial therapy without recurrent infection. It is important to remember that BAV is a risk factor for not only AAD but also IE, which sometimes occurs simultaneously and requires an emergent operation due to high mortality.


Assuntos
Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Valva Aórtica/anormalidades , Endocardite/diagnóstico , Cardiopatias Congênitas/diagnóstico , Doença Aguda , Dissecção Aórtica/cirurgia , Anti-Infecciosos/uso terapêutico , Aneurisma Aórtico/cirurgia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Desbridamento , Endocardite/complicações , Endocardite/cirurgia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
Interact Cardiovasc Thorac Surg ; 5(5): 599-601, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17670657

RESUMO

OBJECTIVES: A girl who was diagnosed with cyanotic congenital heart disease in a newborn, showed anoxic spell attacks which we thought were correlated with the congenital heart disease. Although she underwent the palliative operation at 8 months old and her SpO2 was increased, she experienced severe and life-threatening respiratory dysfunction many times after that. After careful examinations, the respiratory complaint was proved to be not only due to cyanotic congenital heart disease but also tracheobronchomalacia. METHOD: She had undergone the external stenting to the trachea and right bronchus at 1 year old. After that, she was examined by cardiac catheterization and the Fontan-type operation was successful using a tissue-engineered graft at 2 years old. RESULTS: Her post-operative course was uneventful and she was discharged. CONCLUSION: It is very important to remember the possible existence of tracheobronchomalacia and prevent a life-threatening attack when congenital cardiac patients experience a prolonged respiratory failure or abnormal respiration.

13.
Kyobu Geka ; 57(12): 1143-5, 2004 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-15553034

RESUMO

A 54-year-old man with ischemic mitral regurgitation and severe heart failure due to broad myocardial infarction successfully underwent mitral valve plasty and coronary artery bypass grafting under beating heart. He had an old anterior myocardial infarction and was admitted to our hospital with acute inferior myocardial infarction. Two weeks later, the cathetelization revealed moderate mitral regurgitation and triple vessel coronary artery disease. We selected antegrade continuous blood perfusion for myocardial protection on operation. He recovered uneventfully and discharged on postoperative day 31. We could perform this procedure safety and satisfactorily, we could this procedure for heart valve operation with other complications.


Assuntos
Ponte Cardiopulmonar , Ponte de Artéria Coronária sem Circulação Extracorpórea , Implante de Prótese de Valva Cardíaca , Valva Mitral/cirurgia , Disfunção Ventricular Esquerda/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Masculino , Pessoa de Meia-Idade
14.
Jpn J Thorac Cardiovasc Surg ; 51(11): 619-21, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14650594

RESUMO

We describe a transapical aortic cannulation procedure through a left thoracotomy for a case of acute traumatic aortic rupture. A 26-year-old man was involved in a motor vehicle accident and admitted in a state of hypovolemic shock. Chest computed tomography findings revealed a rupture of the proximal portion of the descending aorta and a massive hematoma around the aorta extending into the thoracic cavity. Under hypothermic circulatory arrest, he underwent an emergency graft replacement through a left thoracotomy. We used transapical aortic cannulation together with femoral cannulation, in order to avoid malperfusion of the brain and upper body that can occur as a result of retrograde perfusion. The postoperative outcome was favorable. Transapical cannulation is a useful alternative for hypothermic aortic operations through a left thoracotomy.


Assuntos
Aorta Torácica/lesões , Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Hipotermia Induzida , Toracotomia/métodos , Acidentes de Trânsito , Adulto , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...