Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Perioper Med ; 6: e40474, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36804173

RESUMO

BACKGROUND: Postoperative deterioration is often preceded by abnormal vital parameters. Therefore, vital parameters of postoperative patients are routinely measured by nursing staff. Wrist-worn sensors could potentially provide an alternative tool for the measurement of vital parameters in low-acuity settings. These devices would allow more frequent or even continuous measurements of vital parameters without relying on time-consuming manual measurements, provided their accuracy in this clinical population is established. OBJECTIVE: This study aimed to assess the accuracy of heart rate (HR) and respiratory rate (RR) measures obtained via a wearable photoplethysmography (PPG) wristband in a cohort of postoperative patients. METHODS: The accuracy of the wrist-worn PPG sensor was assessed in 62 post-abdominal surgery patients (mean age 55, SD 15 years; median BMI 34, IQR 25-40 kg/m2). The wearable obtained HR and RR measurements were compared to those of the reference monitor in the postanesthesia or intensive care unit. Bland-Altman and Clarke error grid analyses were performed to determine agreement and clinical accuracy. RESULTS: Data were collected for a median of 1.2 hours per patient. With a coverage of 94% for HR and 34% for RR, the device was able to provide accurate measurements for the large majority of the measurements as 98% and 93% of the measurements were within 5 bpm or 3 rpm of the reference signal. Additionally, 100% of the HR and 98% of the RR measurements were clinically acceptable on Clarke error grid analysis. CONCLUSIONS: The wrist-worn PPG device is able to provide measurements of HR and RR that can be seen as sufficiently accurate for clinical applications. Considering the coverage, the device was able to continuously monitor HR and report RR when measurements of sufficient quality were obtained. TRIAL REGISTRATION: ClinicalTrials.gov NCT03923127; https://www.clinicaltrials.gov/ct2/show/NCT03923127.

2.
Sleep Med ; 100: 573-576, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36327586

RESUMO

Previous research has shown an interplay between the thalamus and cerebral cortex during NREM sleep in humans, however the directionality of the thalamocortical synchronization is as yet unknown. In this study thalamocortical connectivity during different NREM sleep stages using sleep scalp electroencephalograms and local field potentials from the left and right anterior thalamus was measured in three epilepsy patients implanted with deep brain stimulation electrodes. Connectivity was assessed as debiased weighted phase lag index and granger causality between the thalamus and cortex for the NREM sleep stages N1, N2 and N3. Results showed connectivity was most prominently directed from cortex to thalamus. Moreover, connectivity varied in strength between the different sleep stages, but barely in direction or frequency. These results imply relatively stable thalamocortical connectivity during NREM sleep directed from the cortex to the thalamus.


Assuntos
Estimulação Encefálica Profunda , Humanos , Estimulação Encefálica Profunda/métodos , Fases do Sono/fisiologia , Eletroencefalografia/métodos , Tálamo , Córtex Cerebral/fisiologia , Sono/fisiologia
3.
Eur J Surg Oncol ; 48(4): 917-923, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34753618

RESUMO

INTRODUCTION: Recent advances in wearable technology allow for the development of wirelessly connected sensors to continuously measure vital parameters in the general ward or even at home. The present study assesses the accuracy of a wearable patch (Healthdot) for continuous monitoring of heartrate (HR) and respiration rate (RR). MATERIALS AND METHODS: The Healthdot measures HR and RR by means of chest accelerometry. The study population consisted of patients following major abdominal oncological surgery. The analysis focused on the agreement between HR and RR measured by the Healthdot and the gold standard patient monitor in the intensive and post-anesthesia care unit. RESULTS: For HR, a total of 112 h of measurements was collected in 26 patients. For RR, a total of 102 h of measurements was collected in 21 patients. On second to second analysis, 97% of the HR and 87% of the RR measurements were within 5 bpm and 3 rpm of the reference monitor. Assessment of 5-min averaged data resulted in 96% of the HR and 95% of the RR measurements within 5 bpm and 3 rpm of the reference monitor. A Clarke error grid analysis showed that 100% of the HR and 99.4% of the 5-min averaged data was clinically acceptable. CONCLUSION: The Healthdot accurately measured HR and RR in a cohort of patients recovering from major abdominal surgery, provided that good quality data was obtained. These results push the Healthdot forward as a clinically acceptable tool in low acuity settings for unobtrusive, automatic, wireless and continuous monitoring.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Frequência Cardíaca , Humanos , Monitorização Fisiológica , Taxa Respiratória
4.
PLoS One ; 16(4): e0247903, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33909642

RESUMO

Recognition of early signs of deterioration in postoperative course could be improved by continuous monitoring of vital parameters. Wearable sensors could enable this by wireless transmission of vital signs. A novel accelerometer-based device, called Healthdot, has been designed to be worn on the skin to measure the two key vital parameters respiration rate (RespR) and heart rate (HeartR). The goal of this study is to assess the reliability of heart rate and respiration rate measured by the Healthdot in comparison to the gold standard, the bedside patient monitor, during the postoperative period in bariatric patients. Data were collected in a consecutive group of 30 patients who agreed to wear the device after their primary bariatric procedure. Directly after surgery, a Healthdot was attached on the patients' left lower rib. Vital signs measured by the accelerometer based Healthdot were compared to vital signs collected with the gold standard patient monitor for the period that the patient stayed at the post-anesthesia care unit. Over all patients, a total of 22 hours of vital signs obtained by the Healthdot were recorded simultaneously with the bedside patient monitor data. 87.5% of the data met the pre-defined bias of 5 beats per minute for HeartR and 92.3% of the data met the pre-defined bias of 5 respirations per minute for RespR. The Healthdot can be used to accurately derive heart rate and respiration rate in postbariatric patients. Wireless continuous monitoring of key vital signs has the potential to contribute to earlier recognition of complications in postoperative patients. Future studies should focus on the ability to detect patient deterioration in low-care environments and at home after discharge from the hospital.


Assuntos
Acelerometria , Cirurgia Bariátrica , Frequência Cardíaca , Taxa Respiratória , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA