Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Clin Psychopharmacol ; 35(1): 22-33, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25493397

RESUMO

OBJECTIVE: AZD6280 is a novel γ-aminobutyric acid A receptor modulator with higher in vitro efficacy at the α2,3 subtypes as compared to the α1 and α5 subtypes. This study compared the pharmacodynamic effects of single oral dose AZD6280 10 mg and 40 mg on the central nervous system with 2 mg of lorazepam. METHODS: Sixteen healthy males were enrolled into the double-blind, randomized, 4-way crossover study. Two validated central nervous system test batteries, Neurocart and CogState, were administered to measure drug effects on cognition, neurophysiologic function, and psychomotor and subjective feelings. Statistical analysis was performed using mixed model analysis of variance, with fixed factors of treatment, period, time and treatment by time, and random factors of subject, subject by treatment and subject by time, and the average prevalue as covariate. RESULTS: Most pharmacodynamic parameters were affected by lorazepam. AZD6280 induced dose-dependent smaller-than-lorazepam effects on saccadic peak velocity (SPV) (AZD6280, 10 mg vs. AZD6280, 40 mg vs. lorazepam [deg/s]: -22.6 vs. -50.0 vs. -62.9, P < 0.001), whereas the impacts on adaptive-tracking, body-sway, smooth-pursuit, and the one-card-learning tests were significant but much smaller than lorazepam. Thus, the slopes of regression lines for the ΔLog(Sway)-ΔSPV, ΔTracking-ΔSPV, and ΔSmooth-ΔSPV relations were flatter with AZD6280 than with lorazepam. AZD6280 caused a distinct electroencephalography signature from that of lorazepam. CONCLUSIONS: The SPV responses to AZD6280 suggest potential concentration-related anxiolytic effects, whereas the smaller SPV-normalized effects of AZD6280 on various non-SPV pharmacodynamic parameters suggest a more favorable side effect profile compared to lorazepam. Overall, the pharmacodynamic profile of AZD6280 matches the pharmacological specificity and selectivity of this compound at the α2,3 γ-aminobutyric acid A receptor subtypes.


Assuntos
Moduladores GABAérgicos/farmacologia , Voluntários Saudáveis , Compostos Heterocíclicos com 2 Anéis/farmacologia , Receptores de GABA-A , Adolescente , Adulto , Estudos Cross-Over , Método Duplo-Cego , Moduladores GABAérgicos/metabolismo , Compostos Heterocíclicos com 2 Anéis/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Receptores de GABA-A/metabolismo , Resultado do Tratamento , Adulto Jovem
2.
Circulation ; 111(18): 2326-9, 2005 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-15851603

RESUMO

BACKGROUND: Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation. METHODS AND RESULTS: The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n=15] and fast release [FR; n=15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the total population (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group (0.41+/-0.49 mm) than the SR group (0.09+/-0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR=9.1% and SR=5.7%). CONCLUSIONS: This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimus-eluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation).


Assuntos
Sirolimo/administração & dosagem , Stents/efeitos adversos , Doenças Cardiovasculares , Angiografia Coronária , Intervalo Livre de Doença , Seguimentos , Oclusão de Enxerto Vascular , Humanos , Incidência , Cinética , Stents/normas , Resultado do Tratamento , Ultrassonografia de Intervenção
3.
Circulation ; 111: 2326-2329, 25 apr 2005. ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062008

RESUMO

Background—Despite the proven superiority of sirolimus-eluting stents (SES) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation.Methods and Results—The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n 15] and fast release [FR; n 15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the totalpopulation (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group(0.41 0.49 mm) than the SR group (0.09 0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR 9.1% and SR 5.7%).Conclusions—This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimuseluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation).


Assuntos
Angiografia/métodos , Angiografia/tendências , Reestenose Coronária/complicações , Reestenose Coronária/prevenção & controle , Reestenose Coronária/tratamento farmacológico , Stents/tendências
4.
Circulation ; 107(1): 24-31, 7/14 janeiro de 2004. ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061992

RESUMO

We have previously repoted the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis .Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil.Nine patients received 2 stents (1,4 stents per lesion).Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 mounths. All vessels were patent at the time of 12-months angiografy.Angiographic late loss averaged...


Assuntos
Humanos , Angiografia Coronária , Reestenose Coronária , Stents , Ultrassom
5.
Circulation ; 107(1): 24-7, 2003 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-12515737

RESUMO

BACKGROUND: We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. METHODS AND RESULTS: Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07+/-0.2 mm in-stent and -0.05+/-0.3 mm in-lesion at 4 months, and 0.36+/-0.46 mm in-stent and 0.16+/-0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92+/-1.9 mm(3) at 4 months and 2.55+/-4.9 mm(3) after 1 year. Percent volume obstruction was 0.81+/-1.7% and 1.76+/-3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. CONCLUSION: This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.


Assuntos
Reestenose Coronária/tratamento farmacológico , Sirolimo/administração & dosagem , Stents , Terapia Combinada , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/cirurgia , Preparações de Ação Retardada , Ecocardiografia Tridimensional , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prevenção Secundária , Sirolimo/uso terapêutico , Stents/efeitos adversos
6.
Circulation ; 107(3): 381-3, 2003 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-12551858

RESUMO

BACKGROUND: The safety and efficacy of sirolimus-eluting stenting have been demonstrated, but the outcome of patients treated with this novel technology beyond the first year remains unknown. We sought to evaluate the angiographic, intravascular ultrasound (IVUS), and clinical outcomes of patients treated with sirolimus-eluting stents 2 years after implantation. METHODS AND RESULTS: This study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR], n=15, and fast release [FR], n=15) in São Paulo, Brazil. Twenty-eight patients underwent 2-year angiographic and IVUS follow-up. No deaths occurred during the study period. In-stent late loss was slightly greater in the FR group (0.28+/-0.4 mm) than in the SR group (-0.09+/-0.23 mm, P=0.007). No patient had in-stent restenosis. At 2-year follow-up, only 1 patient (FR group) had a 52% diameter stenosis within the lesion segment, which required repeat revascularization. The target-vessel revascularization rate for the entire cohort was 10% (3/30) at 2 years. All other patients had < or =35% diameter stenosis. Angiographic lumen loss at the stent edges was also minimal (in-lesion late loss was 0.33+/-0.42 mm [FR] and 0.13+/-0.29 mm [SR]). In-stent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 2 years (FR= 9.90+/-9 mm3 and SR=10.35+/-9.3 mm3). CONCLUSIONS: This study demonstrates the safety and efficacy of sirolimus-eluting Bx Velocity stents 2 years after implantation in humans. In-stent lumen dimensions remained essentially unchanged at 2-year follow-up in the 2 groups, although angiographic lumen loss was slightly higher in the FR group. Restenosis "catch-up" was not found in our patient population.


Assuntos
Doença da Artéria Coronariana , Sirolimo/administração & dosagem , Stents , Terapia Combinada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Preparações de Ação Retardada , Seguimentos , Humanos , Sirolimo/uso terapêutico , Stents/efeitos adversos , Resultado do Tratamento , Ultrassonografia
7.
Circulation ; 104: 2007-2011, 29 de julho de 2001.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061980

RESUMO

Background—We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. Methods and Results—Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in São Paulo, Brazil (n530, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular


ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the $50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis


was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (265% obstruction volume, GIII) and at 12 months (GI5265% and GII5263%). Conclusions—This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.


Assuntos
Angiografia , Reestenose Coronária , Stents , Ultrassom
8.
Circulation ; 103(2): 192-195, 16 jan 2001. ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061977

RESUMO

Background- Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor) coated BX velocity stents. Methdo and Results- Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analized angiographic and 3D volumetric intravascular ultrasound data (immediatlly after procedure and at 4-month follow-up). Eigth month clinical follow-up was obtained for all patients...


Assuntos
Angioplastia , Reestenose Coronária , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA