Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
NPJ Digit Med ; 7(1): 136, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783001

RESUMO

Data from commercial off-the-shelf (COTS) wearables leveraged with machine learning algorithms provide an unprecedented potential for the early detection of adverse physiological events. However, several challenges inhibit this potential, including (1) heterogeneity among and within participants that make scaling detection algorithms to a general population less precise, (2) confounders that lead to incorrect assumptions regarding a participant's healthy state, (3) noise in the data at the sensor level that limits the sensitivity of detection algorithms, and (4) imprecision in self-reported labels that misrepresent the true data values associated with a given physiological event. The goal of this study was two-fold: (1) to characterize the performance of such algorithms in the presence of these challenges and provide insights to researchers on limitations and opportunities, and (2) to subsequently devise algorithms to address each challenge and offer insights on future opportunities for advancement. Our proposed algorithms include techniques that build on determining suitable baselines for each participant to capture important physiological changes and label correction techniques as it pertains to participant-reported identifiers. Our work is validated on potentially one of the largest datasets available, obtained with 8000+ participants and 1.3+ million hours of wearable data captured from Oura smart rings. Leveraging this extensive dataset, we achieve pre-symptomatic detection of COVID-19 with a performance receiver operator characteristic (ROC) area under the curve (AUC) of 0.725 without correction techniques, 0.739 with baseline correction, 0.740 with baseline correction and label correction on the training set, and 0.777 with baseline correction and label correction on both the training and the test set. Using the same respective paradigms, we achieve ROC AUCs of 0.919, 0.938, 0.943 and 0.994 for the detection of self-reported fever, and 0.574, 0.611, 0.601, and 0.635 for detection of self-reported shortness of breath. These techniques offer improvements across almost all metrics and events, including PR AUC, sensitivity at 75% specificity, and precision at 75% recall. The ring allows continuous monitoring for detection of event onset, and we further demonstrate an improvement in the early detection of COVID-19 from an average of 3.5 days to an average of 4.1 days before a reported positive test result.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37768790

RESUMO

Accurate estimation of physiological biomarkers using raw waveform data from non-invasive wearable devices requires extensive data preprocessing. An automatic noise detection method in time-series data would offer significant utility for various domains. As data labeling is onerous, having a minimally supervised abnormality detection method for input data, as well as an estimation of the severity of the signal corruptness, is essential. We propose a model-free, time-series biomedical waveform noise detection framework using a Variational Autoencoder coupled with Gaussian Mixture Models, which can detect a range of waveform abnormalities without annotation, providing a confidence metric for each segment. Our technique operates on biomedical signals that exhibit periodicity of heart activities. This framework can be applied to any machine learning or deep learning model as an initial signal validator component. Moreover, the confidence score generated by the proposed framework can be incorporated into different models' optimization to construct confidence-aware modeling. We conduct experiments using dynamic time warping (DTW) distance of segments to validated cardiac cycle morphology. The result confirms that our approach removes noisy cardiac cycles and the remaining signals, classified as clean, exhibit a 59.92% reduction in the standard deviation of DTW distances. Using a dataset of bio-impedance data of 97885 cardiac cycles, we further demonstrate a significant improvement in the downstream task of cuffless blood pressure estimation, with an average reduction of 2.67 mmHg root mean square error (RMSE) of Diastolic Blood pressure and 2.13 mmHg RMSE of systolic blood pressure, with increases of average Pearson correlation of 0.28 and 0.08, with a statistically significant improvement of signal-to-noise ratio respectively in the presence of different synthetic noise sources. This enables burden-free validation of wearable sensor data for downstream biomedical applications.

3.
NPJ Digit Med ; 6(1): 110, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37296218

RESUMO

The bold vision of AI-driven pervasive physiological monitoring, through the proliferation of off-the-shelf wearables that began a decade ago, has created immense opportunities to extract actionable information for precision medicine. These AI algorithms model input-output relationships of a system that, in many cases, exhibits complex nature and personalization requirements. A particular example is cuffless blood pressure estimation using wearable bioimpedance. However, these algorithms need training over significant amount of ground truth data. In the context of biomedical applications, collecting ground truth data, particularly at the personalized level is challenging, burdensome, and in some cases infeasible. Our objective is to establish physics-informed neural network (PINN) models for physiological time series data that would use minimal ground truth information to extract complex cardiovascular information. We achieve this by building Taylor's approximation for gradually changing known cardiovascular relationships between input and output (e.g., sensor measurements to blood pressure) and incorporating this approximation into our proposed neural network training. The effectiveness of the framework is demonstrated through a case study: continuous cuffless BP estimation from time series bioimpedance data. We show that by using PINNs over the state-of-the-art time series models tested on the same datasets, we retain high correlations (systolic: 0.90, diastolic: 0.89) and low error (systolic: 1.3 ± 7.6 mmHg, diastolic: 0.6 ± 6.4 mmHg) while reducing the amount of ground truth training data on average by a factor of 15. This could be helpful in developing future AI algorithms to help interpret pervasive physiologic data using minimal amount of training data.

4.
IEEE J Biomed Health Inform ; 27(9): 4273-4284, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37363851

RESUMO

We propose our Confidence-Aware Particle Filter (CAPF) framework that analyzes a series of estimated changes in blood pressure (BP) to provide several true state hypotheses for a given instance. Particularly, our novel confidence-awareness mechanism assigns likelihood scores to each hypothesis in an effort to discard potentially erroneous measurements - based on the agreement amongst a series of estimated changes and the physiological plausibility when considering DBP/SBP pairs. The particle filter formulation (or sequential Monte Carlo method) can jointly consider the hypotheses and their probabilities over time to provide a stable trend of estimated BP measurements. In this study, we evaluate BP trend estimation from an emerging bio-impedance (Bio-Z) prototype wearable modality although it is applicable to all types of physiological modalities. Each subject in the evaluation cohort underwent a hand-gripper exercise, a cold pressor test, and a recovery state to increase the variation to the captured BP ranges. Experiments show that CAPF yields superior continuous pulse pressure (PP), diastolic blood pressure (DBP), and systolic blood pressure (SBP) estimation performance compared to ten baseline approaches. Furthermore, CAPF performs on track to comply with AAMI and BHS standards for achieving a performance classification of Grade A, with mean error accuracies of -0.16 ± 3.75 mmHg for PP (r = 0.81), 0.42 ± 4.39 mmHg for DBP (r = 0.92), and -0.09 ± 6.51 mmHg for SBP (r = 0.92) from more than test 3500 data points.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos
5.
JACC Adv ; 2(2)2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37152621

RESUMO

Traditional measures of clinical status and physiology have generally been based in health care settings, episodic, short in duration, and performed at rest. Wearable biosensors provide an opportunity to obtain continuous non-invasive physiologic data from patients with congenital heart disease (CHD) in the real-world setting, over longer durations, and across varying levels of activity. However, there are significant technical limitations to the use of wearable biosensors in CHD. Here, we review current applications of wearable biosensors in CHD; how clinical and research uses of wearable biosensors must consider various CHD physiologies; the technical challenges in developing wearable biosensors for CHD; and special considerations for digital biomarkers in CHD.

6.
NPJ Digit Med ; 6(1): 59, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36997608

RESUMO

Smart rings provide unique opportunities for continuous physiological measurement. They are easy to wear, provide little burden in comparison to other smart wearables, are suitable for nocturnal settings, and can be sized to provide ideal contact between the sensors and the skin at all times. Continuous measuring of blood pressure (BP) provides essential diagnostic and prognostic value for cardiovascular health management. However, conventional ambulatory BP measurement devices operate using an inflating cuff that is bulky, intrusive, and impractical for frequent or continuous measurements. We introduce ring-shaped bioimpedance sensors leveraging the deep tissue sensing ability of bioimpedance while introducing no sensitivity to skin tones, unlike optical modalities. We integrate unique human finger finite element model with exhaustive experimental data from participants and derive optimum design parameters for electrode placement and sizes that yields highest sensitivity to arterial volumetric changes, with no discrimination against varying skin tones. BP is constructed using machine learning algorithms. The ring sensors are used to estimate arterial BP showing peak correlations of 0.81, and low error (systolic BP: 0.11 ± 5.27 mmHg, diastolic BP: 0.11 ± 3.87 mmHg) for >2000 data points and wide BP ranges (systolic: 89-213 mmHg and diastolic: 42-122 mmHg), highlighting the significant potential use of bioimpedance ring for accurate and continuous estimation of BP.

7.
Res Sq ; 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36711741

RESUMO

The bold vision of AI-driven pervasive physiological monitoring, through the proliferation of off-the-shelf wearables that began a decade ago, has created immense opportunities to extract actionable information for precision medicine. These AI algorithms model the input-output relationships of a system that, in many cases, exhibits complex nature and personalization requirements. A particular example is cuffless blood pressure estimation using wearable bioimpedance. However, these algorithms need to be trained with a significant amount of ground truth data. In the context of biomedical applications, collecting ground truth data, particularly at the personalized level is challenging, burdensome, and in some cases infeasible. Our objective is to establish physics-informed neural network (PINN) models for physiological time series data that would reduce reliance on ground truth information. We achieve this by building Taylor's approximation for the gradually changing known cardiovascular relationships between input and output (e.g., sensor measurements to blood pressure) and incorporating this approximation into our proposed neural network training. The effectiveness of the framework is demonstrated through a case study: continuous cuffless BP estimation from time series bioimpedance data. We show that by using PINNs over the state-of-the-art time series regression models tested on the same datasets, we retain a high correlation (systolic: 0.90, diastolic: 0.89) and low error (systolic: 1.3 ± 7.6 mmHg, diastolic: 0.6 ± 6.4 mmHg) while reducing the amount of ground truth training data on average by a factor of 15. This could be helpful in developing future AI algorithms to help interpret pervasive physiologic data using minimal amount of training data.

8.
Nat Commun ; 13(1): 6604, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36329038

RESUMO

Electrodermal activity (EDA) is a popular index of mental stress. State-of-the-art EDA sensors suffer from obstructiveness on the palm or low signal fidelity off the palm. Our previous invention of sub-micron-thin imperceptible graphene e-tattoos (GET) is ideal for unobstructive EDA sensing on the palm. However, robust electrical connection between ultrathin devices and rigid circuit boards is a long missing component for ambulatory use. To minimize the well-known strain concentration at their interfaces, we propose heterogeneous serpentine ribbons (HSPR), which refer to a GET serpentine partially overlapping with a gold serpentine without added adhesive. A fifty-fold strain reduction in HSPR vs. heterogeneous straight ribbons (HSTR) has been discovered and understood. The combination of HSPR and a soft interlayer between the GET and an EDA wristband enabled ambulatory EDA monitoring on the palm in free-living conditions. A newly developed EDA event selection policy leveraging unbiased selection of phasic events validated our GET EDA sensor against gold standards.


Assuntos
Grafite , Tatuagem , Resposta Galvânica da Pele , Monitorização Ambulatorial
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2886-2890, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085964

RESUMO

Bioimpedance has emerged as a promising modality to continuously monitor hemodynamic and respiratory physiological parameters through a non-invasive skin-contact approach. Bioimpedance sensors placed at the radial zone of the volar wrist provide sensitive operation to the blood flow of the underlying radial artery. The translation of bioimpedance systems into medical-grade settings for continuous hemodynamic monitoring, however, presents challenges when constraining the necessary sensing components to a minimal form factor while maintaining sufficient accuracy and precision of measurements. Thus, it is important to understand the effects of electrode configuration on bioimpedance signals when reducing them to a wearable form factor. Previous work regarding electrode configurations in bioimpedance does not address wearable constraints, nor do they focus on electrodes viable for wearable applications. In this study, we present empirical evidence of the effects of dry silver electrode sizes and spacings on the specificity and sensitivity of a wrist-worn bioimpedance sensor array. We found that wrist-worn bioimpedance systems for hemodynamic monitoring would benefit from reduced injection electrode spacings (up to a 392% increase in signal amplitude with a 50% decrease in spacing), increased sensing electrode spacings, and decreased electrode surface areas. Clinical Relevance - The work directly contributes towards the development of cuffless continuous blood pressure monitors with applications in clinical and ambulatory settings.


Assuntos
Articulação do Punho , Punho , Eletrodos , Monitorização Fisiológica
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4286-4290, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086457

RESUMO

The demand for non-obtrusive, accurate, and continuous blood pressure (BP) monitoring systems is becoming more prevalent with the realization of its significance in preventable cardiovascular disease (CVD) globally. Current cuff-based standards are bulky, uncomfortable, and are limited to discrete recording periods. Wearable sensor technologies such as those using optical photoplethysmography (PPG) have been used to develop blood pressure estimation models through a variety of methods. However, this technology falls short as optical based systems have bias favoring lighter skin tones and lower body fat compositions. Bioimpedance (Bio-Z) is a capable modality of sensing arterial blood flow without implicit inadvertent bias towards individuals. In this paper we propose a ring-based bioimpedance system to capture arterial blood flow from the digital artery of the finger. The ring design provides a more compact wearable device utilizing only a single Bio-Z channel, making it a familiar fit to individuals. Post-processing the acquired Bio-Z signals, we extracted 9 frequency domain features from windowed beat cycles to train subject specific regression models. Results indicate the average mean absolute errors for systolic/diastolic BP to be 4.38/3.63mmHg, consistent with AAMI standards.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Impedância Elétrica , Humanos , Fotopletismografia/métodos , Análise de Onda de Pulso/métodos
11.
IEEE J Biomed Health Inform ; 26(11): 5482-5493, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35976844

RESUMO

Estimating physiological parameters - such as blood pressure (BP) - from raw sensor data captured by noninvasive, wearable devices rely on either burdensome manual feature extraction designed by domain experts to identify key waveform characteristics and phases, or deep learning (DL) models that require extensive data collection. We propose the Data-Driven Guided Attention (DDGA) framework to optimize DL models to learn features supported by the underlying physiology and physics of the captured waveforms, with minimal expert annotation. With only a single template waveform cardiac cycle and its labelled fiducial points, we leverage dynamic time warping (DTW) to annotate all other training samples. DL models are trained to first identify them before estimating BP to inform them which regions of the input represent key phases of the cardiac cycle, yet we still grant the flexibility for DL to determine the optimal feature set from them. In this study, we evaluate DDGA's improvements to a BP estimation task for three prominent DL-based architectures with two datasets: 1) the MIMIC-III waveform dataset with ample training data and 2) a bio-impedance (Bio-Z) dataset with less than abundant training data. Experiments show that DDGA improves personalized BP estimation models by an average 8.14% in root mean square error (RMSE) when there is an imbalanced distribution of target values in a training set and improves model generalizability by an average 4.92% in RMSE when testing estimation of BP value ranges not previously seen in training.


Assuntos
Aprendizado Profundo , Humanos , Determinação da Pressão Arterial , Pressão Sanguínea , Impedância Elétrica , Atenção
12.
IEEE Open J Eng Med Biol ; 3: 78-85, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35873901

RESUMO

Goal: To achieve high-quality comprehensive feature extraction from physiological signals that enables precise physiological parameter estimation despite evolving waveform morphologies. Methods: We propose Boosted-SpringDTW, a probabilistic framework that leverages dynamic time warping (DTW) and minimal domain-specific heuristics to simultaneously segment physiological signals and identify fiducial points that represent cardiac events. An automated dynamic template adapts to evolving waveform morphologies. We validate Boosted-SpringDTW performance with a benchmark PPG dataset whose morphologies include subject- and respiratory-induced variation. Results: Boosted-SpringDTW achieves precision, recall, and F1-scores over 0.96 for identifying fiducial points and mean absolute error values less than 11.41 milliseconds when estimating IBI. Conclusion: Boosted-SpringDTW improves F1-Scores compared to two baseline feature extraction algorithms by 35% on average for fiducial point identification and mean percent difference by 16% on average for IBI estimation. Significance: Precise hemodynamic parameter estimation with wearable devices enables continuous health monitoring throughout a patients' daily life.

13.
Nat Nanotechnol ; 17(8): 864-870, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35725927

RESUMO

Continuous monitoring of arterial blood pressure (BP) in non-clinical (ambulatory) settings is essential for understanding numerous health conditions, including cardiovascular diseases. Besides their importance in medical diagnosis, ambulatory BP monitoring platforms can advance disease correlation with individual behaviour, daily habits and lifestyle, potentially enabling analysis of root causes, prognosis and disease prevention. Although conventional ambulatory BP devices exist, they are uncomfortable, bulky and intrusive. Here we introduce a wearable continuous BP monitoring platform that is based on electrical bioimpedance and leverages atomically thin, self-adhesive, lightweight and unobtrusive graphene electronic tattoos as human bioelectronic interfaces. The graphene electronic tattoos are used to monitor arterial BP for >300 min, a period tenfold longer than reported in previous studies. The BP is recorded continuously and non-invasively, with an accuracy of 0.2 ± 4.5 mm Hg for diastolic pressures and 0.2 ± 5.8 mm Hg for systolic pressures, a performance equivalent to Grade A classification.


Assuntos
Grafite , Tatuagem , Pressão Arterial , Determinação da Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial , Humanos
14.
Sci Rep ; 12(1): 319, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013376

RESUMO

Continuous monitoring of blood pressure (BP) is essential for the prediction and the prevention of cardiovascular diseases. Cuffless BP methods based on non-invasive sensors integrated into wearable devices can translate blood pulsatile activity into continuous BP data. However, local blood pulsatile sensors from wearable devices suffer from inaccurate pulsatile activity measurement based on superficial capillaries, large form-factor devices and BP variation with sensor location which degrade the accuracy of BP estimation and the device wearability. This study presents a cuffless BP monitoring method based on a novel bio-impedance (Bio-Z) sensor array built in a flexible wristband with small-form factor that provides a robust blood pulsatile sensing and BP estimation without calibration methods for the sensing location. We use a convolutional neural network (CNN) autoencoder that reconstructs an accurate estimate of the arterial pulse signal independent of sensing location from a group of six Bio-Z sensors within the sensor array. We rely on an Adaptive Boosting regression model which maps the features of the estimated arterial pulse signal to systolic and diastolic BP readings. BP was accurately estimated with average error and correlation coefficient of 0.5 ± 5.0 mmHg and 0.80 for diastolic BP, and 0.2 ± 6.5 mmHg and 0.79 for systolic BP, respectively.


Assuntos
Pressão Arterial , Técnicas Biossensoriais/instrumentação , Determinação da Pressão Arterial/instrumentação , Transdutores , Dispositivos Eletrônicos Vestíveis , Punho/irrigação sanguínea , Adulto , Impedância Elétrica , Desenho de Equipamento , Humanos , Redes Neurais de Computação , Valor Preditivo dos Testes , Fluxo Pulsátil , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Adulto Jovem
15.
IEEE J Biomed Health Inform ; 26(4): 1516-1527, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34398767

RESUMO

Modality translation grants diagnostic value to wearable devices by translating signals collected from low-power sensors to their highly-interpretable counterparts that are more familiar to healthcare providers. For instance, bio-impedance (Bio-Z) is a conveniently collected modality for measuring physiological parameters but is not highly interpretable. Thus, translating it to a well-known modality such as electrocardiogram (ECG) improves the usability of Bio-Z in wearables. Deep learning solutions are well-suited for this task given complex relationships between modalities generated by distinct processes. However, current algorithms usually train a single model for all users that results in ignoring cross-user variations. Retraining for new users usually requires collecting abundant labeled data, which is challenging in healthcare applications. In this paper, we build a modality translation framework to translate Bio-Z to ECG by learning personalized user information without training several independent architectures. Furthermore, our framework is able to adapt to new users in testing using very few samples. We design a meta-learning framework that contains shared and user-specific parameters to account for user differences while learning from the similarity amongst user signals. In this model, a meta-learner approximated by a neural network learns how to learn user-specific parameters and can efficiently update them in testing. Our experiments show that the proposed model reduces the percentage root mean square difference (PRD) by 41% compared to training a single model for all users and by 36% compared to training independent models for each user. When adapting the model to new users, our model outperforms fine-tuning a pre-trained model through back-propagation by 40% using as few as two new samples in testing.


Assuntos
Redes Neurais de Computação , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletrocardiografia , Humanos
16.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 2330-2334, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34890323

RESUMO

Arterial compliance is one of the essential indicators of certain types of cardiovascular disease, with both systematic and local compliance exhibiting significance. Radial arterial compliance (RAC) has been regarded as an important type of local compliance in several long-term pathophysiological studies. Bio-Impedance (Bio-Z) is a non-invasive signal which can be used to unobtrusively monitor blood volume changes, captured using wearable sensors. In this paper, a compliance monitoring technique based on Bio-Z is proposed for long-term RAC measurements. Both the distensibility-blood pressure (BP) relation and compliance-mean artery pressure relation are analyzed to observe interparticipant compliance variations from four healthy participants, by controlling the blood flow in a way similar to the oscillometric method for BP measurement. A Bio-Z based compliance index (DBZI) is proposed that can be leveraged for continuous and unobtrusive sensing paradigms. A consecutive seven-day experiment shows that the mean and standard deviation values of the difference between the median value of the Bio-Z based beat-by-beat calculated compliance and DBZI are 0.17 and 0.20 mOhm/mmHg, respectively. This demonstrates the consistency and repeatability of the measurements. The results show that DBZI can track the Bio-Z based compliance with an error of 9.72% and 11.67%, compared to a gold standard, in terms of mean and standard deviation, respectively.


Assuntos
Determinação da Pressão Arterial , Artéria Radial , Pressão Sanguínea , Complacência (Medida de Distensibilidade) , Impedância Elétrica , Humanos
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7480-7484, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892823

RESUMO

Continuous and unobtrusive blood pressure (BP) monitoring provides significant advantages in predicting the onset of cardiovascular disease. Bio-impedance sensing is a prominent method for continuous BP monitoring in a wearable form factor that can effectively measure blood pulsations from the arteries and translate them into BP. However, assessing the quality of the bio-impedance signal captured from small electrodes placed on the skin is required to determine the accuracy of BP estimation. In wearable devices, frequent movements of the electrodes on the skin are expected which cause non-optimal contact quality between the electrodes and the skin. This can lead to high skin-electrode impedance which can cause saturation of the current injection module of the bio-impedance device. This phenomenon degrades the signal quality In this paper, we present an automatic gain control (AGC) circuit that controls the amplitude of the current injection into the body based on sensing the skin-electrode impedance to ensure injection of maximum current to maximize the signal-to-noise ratio (SNR) while avoiding saturation of the current injection module. In this work, the proposed AGC method shows higher quality of blood pulsation from bio-impedance signal measured from a human subject with 1.59 dB improvement in SNR which leads to a better estimation of blood pressure.Clinical Relevance- The proposed automatic gain control (AGC) circuit establishes a more accurate method of continuous blood pressure monitoring using bio-impedance.


Assuntos
Determinação da Pressão Arterial , Pressão Sanguínea , Impedância Elétrica , Eletrodos , Humanos , Razão Sinal-Ruído
18.
Front Digit Health ; 3: 731076, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34713201

RESUMO

This paper presents an energy-efficient classification framework that performs human activity recognition (HAR). Typically, HAR classification tasks require a computational platform that includes a processor and memory along with sensors and their interfaces, all of which consume significant power. The presented framework employs microelectromechanical systems (MEMS) based Continuous Time Recurrent Neural Network (CTRNN) to perform HAR tasks very efficiently. In a real physical implementation, we show that the MEMS-CTRNN nodes can perform computing while consuming power on a nano-watts scale compared to the micro-watts state-of-the-art hardware. We also confirm that this huge power reduction doesn't come at the expense of reduced performance by evaluating its accuracy to classify the highly cited human activity recognition dataset (HAPT). Our simulation results show that the HAR framework that consists of a training module, and a network of MEMS-based CTRNN nodes, provides HAR classification accuracy for the HAPT that is comparable to traditional CTRNN and other Recurrent Neural Network (RNN) implantations. For example, we show that the MEMS-based CTRNN model average accuracy for the worst-case scenario of not using pre-processing techniques, such as quantization, to classify 5 different activities is 77.94% compared to 78.48% using the traditional CTRNN.

19.
IEEE Trans Biomed Circuits Syst ; 15(5): 1066-1078, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34550891

RESUMO

This paper presents a reconfigurable electrocardiogram (ECG) analog front-end (AFE) exploiting bio-signals' inherent low activity and quasi-periodicity to reduce power consumption. This is realized by an agile, on-the-fly dynamic noise-power trade-off performed over specific cardiac cycle regions guided by a least mean squares (LMS)-based adaptive predictor leading to ∼2.5× data-dependent power savings. Implemented in 65 nm CMOS, the AFE has tunable performance exhibiting an input-referred noise ranging from 2.38 - 3.64 µVrms while consuming 307 - 769 nW from a 0.8 V supply. A comprehensive system performance verification was performed using ECG records from standard databases to establish the feasibility of the proposed predictor-based approach for power savings without compromising the system's anomaly detection capability or ability to extract pristine ECG features.


Assuntos
Amplificadores Eletrônicos , Eletrocardiografia , Bases de Dados Factuais , Desenho de Equipamento , Processamento de Sinais Assistido por Computador
20.
IEEE Open J Eng Med Biol ; 2: 210-217, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34458855

RESUMO

OBJECTIVE: Bioimpedance sensing is a powerful technique that measures the tissue impedance and captures important physiological parameters including blood flow, lung movements, muscle contractions, body fluid shifts, and other cardiovascular parameters. This paper presents a comprehensive analysis of the modality at different arterial (ulnar, radial, tibial, and carotid arteries) and thoracic (side-rib cage and top thoracolumbar fascia) body regions and offers insights into the effectiveness of capturing various cardiac and respiratory activities. METHODS: We assess the bioimpedance performance in estimating inter-beat (IBI) and inter -breath intervals (IBrI) on six-hours of data acquired in a pilot-study from five healthy participants at rest. RESULTS: Overall, we achieve mean errors as low as 0.003 ± 0.002 and 0.67 ± 0.28 seconds for IBI and IBrI estimations, respectively. CONCLUSIONS: The results show that bioimpedance can be effectively used to monitor cardiac and respiratory activities both at limbs and upper body and demonstrate a strong potential to be adopted by wearables that aim to provide high-fidelity physiological sensing to address precision medicine needs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...