Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Front Med (Lausanne) ; 11: 1302431, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435388

RESUMO

Through their effects on sleep duration, bedroom environments, and pollen allergies, seasonal variations may impact positive airway pressure (PAP) adherence. We analyzed daily PAP telemonitoring data from 25,846 adults (median age 64 years, 67.8% male) treated with PAP for at least 4 months [mean (standard deviation, SD) duration of PAP: 5.5 years (SD 4.1)] to examine seasonal changes in PAP adherence, leaks, and residual apnea-hypopnea index. We demonstrate a significant decrease in PAP adherence in June compared to January (mean (SD): 0.37 (1.54) h/night) that achieved the minimal clinically important difference (MCID) of 30 min in 13.9% of adults. Furthermore, we provide novel data supporting the association of rising temperatures with seasonal changes in PAP use. Indeed, the most pronounced decline in PAP adherence was observed during the hottest days, while PAP adherence was only slightly reduced during the coolest days of June. Clinicians should be aware of seasonal changes in PAP adherence that are likely to be exacerbated by climate change.

2.
Sleep Med ; 112: 188-190, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37897963

RESUMO

Leakage is a common issue with PAP therapy and may contribute to short-term non-compliance with treatment. PAP manufacturers use different methods to estimate and report air leaks (median, mean, p90, p95, % of important air leak, time spent on major leaks), which makes the analysis and comparisons challenging. Leak intensity is a well-known parameter of major importance as it can significantly affect the performance of PAP devices. However, there is a lack of knowledge regarding another leakage parameter, namely the leakage pattern. As of now, there is no standard classification for leak patterns in real-life settings. Our objective was to develop and propose a comprehensive nomenclature for leakage patterns observed during nasal auto-PAP therapy. We examined 50 ventilatory polygraphy recordings conducted with auto-PAP, based on data from a prior study in which the unintentional leak flow was precisely measured over time. We have categorized leaks into two main types: continuous leaks, which appear and persist for an extended period, and discontinuous leaks, which vanish more rapidly. Continuous leaks can have both abrupt or gradual apparitions and terminations. Their "shape" can be either interrupted or constant. Discontinuous leaks can have both abrupt or gradual apparitions and terminations. Due to the relatively short observation scale (less than 5 min minutes), this type of leakage is not characterized by a specific shape between apparition and termination. This nomenclature could be a valuable tool that facilitates comparative bench tests or clinical studies. This tool could support manufacturers in developing precise algorithms for leak compensation, residual AHI estimation and the accuracy of CPAP monitoring data. Lastly, establishing a standardized approach for describing and categorizing air leakage patterns could assist clinicians in identifying device-related issues, such as patient discomfort arising from specific types of leakage.


Assuntos
Algoritmos , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos
3.
Respir Res ; 24(1): 234, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37759266

RESUMO

BACKGROUND: As the prevalence of OSA increases in older patients, the proportion of elderly patients treated with CPAP is expected to become even higher. We studied CPAP-adherence in a real-life cohort involving a large population of elderly patients with OSA. METHODS: eQUALISAS is a cross-sectional study of CPAP treated OSA patients for at least 4 months who received remote monitoring during 2021. CPAP adherence, device-reported residual AHI (AHICPAP) and 95th percentile non-intentional leaks were software collected during January 2021. Age and sex were also collected. RESULTS: Data from 26,343 patients including 1656 patients aged [80-85] years and 639 patients aged ≥ 85 years were analysed. Median CPAP adherence increases from 6.3 h (< 50 years) to 7 h (75-80 years) and decreases after this age (p < 0.001). The decrease in CPAP adherence observed after the age of 80 was associated with an increase in the proportion of patients with a CPAP-adherence < 4 h/day (p < 0.001). Proportion of CPAP treated female, patients having AHICPAP mean ≥ 10 events per hour or 95th percentile non-intentional leaks mean over 24 l/min increase with aging of the population. However, for patients over 80 years old, Chi square test showed no association of adherence with gender, AHICPAP and leaks (p > 0.05). CONCLUSION: This study demonstrates that adherence gradually increases with age until 80 years. The proportion of non-adherent patients grows with age after 80 years old. No significative relationship was found between adherence after 80 years old and gender, leaks and AHICPAP. TRIAL REGISTRATION: The study is registered on Health Data Hub platform (No. F20220715144543).


Assuntos
Envelhecimento , Apneia Obstrutiva do Sono , Idoso , Humanos , Feminino , Idoso de 80 Anos ou mais , Estudos Transversais , Cooperação do Paciente , Software
4.
ERJ Open Res ; 9(3)2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37377653

RESUMO

Dapagliflozin decreases central sleep apnoea in central sleep apnoea patients, thereby sparing the initiation of ventilatory therapy https://bit.ly/41e2fm0.

5.
Digit Health ; 9: 20552076231167009, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37051564

RESUMO

Background: Obstructive sleep apnea syndrome is a common sleep-breathing disorder associated with adverse health outcomes including excessive daytime sleepiness, impaired quality of life and is well-established as a cardiovascular risk factor. Continuous positive airway pressure is the reference treatment, but its cardiovascular and metabolic benefits are still debated. Combined interventions aiming at improving patient's lifestyle behaviours are recommended in guidelines management of obstructive sleep apnea syndrome but adherence decreases over time and access to rehabilitation programmes is limited. Telerehabilitation is a promising approach to address these issues, but data are scarce on obstructive sleep apnea syndrome. Methods: The aim of this study is to assess the potential benefits of a telerehabilitation programme implemented at continuous positive airway pressure initiation, compared to continuous positive airway pressure alone and usual care, on symptoms and cardiometabolic risk factors of obstructive sleep apnea syndrome. This study is a 6-months multicentre randomized, parallel controlled trial during which 180 obese patients with severe obstructive sleep apnea syndrome will be included. We will use a sequential hierarchical criterion for major endpoints including sleepiness, quality of life, nocturnal systolic blood pressure and inflammation biological parameters. Discussion: m-Rehab obstructive sleep apnea syndrome is the first multicentre randomized controlled trial to examine the effectiveness of a telerehabilitation lifestyle programme in obstructive sleep apnea syndrome. We hypothesize that a telerehabilitation lifestyle intervention associated with continuous positive airway pressure for 6 months will be more efficient than continuous positive airway pressure alone on symptoms, quality of life and cardiometabolic risk profile. Main secondary outcomes include continuous positive airway pressure adherence, usability and satisfaction with the telerehabilitation platform and medico-economic evaluation. Trial registration: Clinicaltrials.gov Identifier: NCT05049928. Registration data: 20 September 2021.

8.
Am J Respir Crit Care Med ; 206(11): 1393-1404, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35816570

RESUMO

Rationale: Randomized controlled trials showed no effect of positive airway pressure (PAP) therapy for obstructive sleep apnea (OSA) on cardiovascular (CV) risk. However, patient selection and low PAP adherence preclude the generalization of their data to clinical samples. Objectives: To evaluate the association between hours of PAP use, mortality, and CV morbidity in real-life conditions. Methods: Data from the Pays de la Loire Cohort were linked to health administrative data to identify incident major adverse cardiovascular events (MACEs; a composite outcome of mortality, stroke, and cardiac diseases) in patients with OSA who were prescribed PAP. Cox proportional hazards analyses were conducted to evaluate the association between MACEs and quartiles of average daily PAP use over the study period. Measurements and Main Results: After a median follow-up of 6.6 years, 961 of 5,138 patients experienced MACEs. Considering nonadherent patients (0-4 h/night) as the reference group, adjusted hazard ratios (95% confidence intervals) for MACEs were 0.87 (0.73-1.04) for the 4-6 h/night group, 0.75 (0.62-0.92) for the 6-7 h/night group, and 0.78 (0.65-0.93) for the ⩾7 h/night group (P = 0.0130). Sensitivity analyses using causal inference approaches confirmed the association of PAP use with MACEs. The association was stronger in male patients (P value for interaction = 0.0004), patients without overt CV disease at diagnosis (P < 0.0001), and those belonging to the excessively sleepy symptom subtype (P = 0.060). Conclusions: These real-life clinical data demonstrate a dose-response relationship between PAP adherence and incident MACEs in OSA. Patient support programs may help improve PAP adherence and CV outcomes in patients with OSA.


Assuntos
Doenças Cardiovasculares , Síndromes da Apneia do Sono , Humanos , Masculino , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/complicações , Pressão Positiva Contínua nas Vias Aéreas , Cooperação do Paciente , Síndromes da Apneia do Sono/complicações , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
10.
Respir Res ; 23(1): 46, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246109

RESUMO

BACKGROUND: Whether the COVID-19 pandemic impacts Positive Airway Pressure (PAP) adherence over the long-term is unknown and only preliminary short-term data have been reported. METHODS: With the aim of describing the impact of the first and second waves of COVID-19 on PAP adherence during 2020 in France, we designed a cross-sectional study of Sleep-Apnea (SA)-patients under PAP telemonitoring. To examine PAP adherence in adult SA patients, we assessed de-identified data from a non-profit healthcare provider database during the period January 1, 2019 to December 31, 2020. Included patients met the following criteria: (i) PAP-treated for at least 4 months before January 1, 2019 and with continuous PAP during both 2019 and 2020; (ii) ≥ 360 daily PAP telemonitored data per year. For PAP adherence, data were collected using the PAP-software. RESULTS: 8477/10482 patients were finally included in the analysis [72.4% male, median age 70 years (IQ25-75: 61-77], 25.6% < 62 years old, initial Apnea-Hypopnea Index (AHI) of 41 (31-59)/h. Median PAP adherence was 7.21 (6.12-8.10) h/day in 2020 versus 7.12 (6.05-8.02) h/day in 2019, p < 0.001. The median difference in PAP adherence between the first 2020 lockdown and the corresponding 2019 weeks was 9.75 (CI95% 8.75-10.75) min/day, p < 0.001. The median difference in PAP adherence between the second 2020 lockdown and the corresponding 2019 weeks was 5.00 (CI95% 4.00-6.00) min/day, p < 0.001. If we consider the minimal clinically important difference of 30 min for PAP adherence, 30.4% and 26% of the patients increased their PAP adherence by at least 30 min during the first and second lockdowns respectively; 17.6% and 19.3% of the patients lowered their PAP adherence by at least 30 min in the first and second lockdowns, respectively. CONCLUSION: During the first and second lockdowns, the COVID-19 pandemic had a clinically irrelevant effect on PAP adherence for the study population. Future studies are needed to describe COVID-19 pandemic impact on PAP adherence not only for long-term PAP-treated SA patients but also for incident cases. Trial registration The COVADENE study was registered on March 1st, 2021 on ClinicalTrials.gov (Identifier: NCT04775966).


Assuntos
COVID-19/epidemiologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Pandemias , Síndromes da Apneia do Sono/terapia , Cooperação e Adesão ao Tratamento , Idoso , Comorbidade , Estudos Transversais , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Síndromes da Apneia do Sono/epidemiologia , Resultado do Tratamento
11.
ESC Heart Fail ; 8(4): 2513-2526, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34102018

RESUMO

AIMS: Optimizing medical cardiac treatment for sleep apnoea (SA) in patients with chronic heart failure and reduced ejection fraction (HFrEF) is an expert Grade C recommendation based on six studies encompassing a total of 67 patients only. Whether sacubitril-valsartan (SV), a cornerstone of HFrEF medical treatment, impacts SA is unknown and requires evaluation. METHODS AND RESULTS: The ENTRESTO-SAS trial is a six-centre, prospective, open-label real-life cohort study (NCT02916160). Ambulatory patients eligible for SV (i.e. HFrEF adults who remain symptomatic despite optimal treatment) were evaluated before and after 3 months of SV (including nocturnal ventilatory polygraphy); 118 patients were final analysed [median age was 66 (IQ25-75 : 56-73) years, 81.4% male, 36.5% New York Heart Association III-IV, N-terminal pro-B-type natriuretic peptide level of 1564 (701-3376) ng/L, left ventricular ejection fraction of 30 (25-34)%, 60.7% ischaemic HFrEF, 97.5% initially treated with angiotensin-converting enzyme inhibitors or angiotensin II receptor blockers, 83.9% with beta-blockers, 64.4% with mineralocorticoid receptor antagonists, and 74.6% with diuretics]. Three groups were defined according to initial central/obstructive apnoea-hypopnoea indices (AHIs): G1 (n = 49, AHIcentral  ≥ 5/h and AHIobstructive  < 15/h); G2 (n = 27, AHIobstructive  ≥ 15/h); and G3 (n = 42, AHIcentral  < 5/h and AHIobstructive  < 15/h). At 3 months, the AHI (main predefined outcome) decreased significantly by -7.10/h (IQ25-75 : -16.10 to 0.40; P < 0.001) in G1 + G2 without positive airway pressure treatment (45 patients, median initial AHI of 24.20 (IQ25-75 : 16.40-43.50)/h). Of these, 24.4% presented an AHI decrease ≥50% and 37.78% had a final AHI < 15/h (tendency for improvement from an initial value of 20%: P = 0.0574). For G1 patients (n = 37), AHI significantly decreased from a median of 22.90 (16.00-43.50)/h to 19.20 (12.70-31.10)/h (P = 0.002). For G2 patients (n = 8), AHI decreased from a median of 30.10 (26.40-47.60)/h to 22.75 (14.60-36.90)/h (statistically non-significant, P = 0.059). CONCLUSIONS: In this real-life population, SV treatment for 3 months in SA patients is associated with a significant decrease in AHI. These results support the current guidelines that recommend first an optimization of the HFrEF treatment in patients with HFrEF and central SA. A potential positive airway pressure sparing effect merits further investigation.


Assuntos
Insuficiência Cardíaca , Síndromes da Apneia do Sono , Idoso , Aminobutiratos , Compostos de Bifenilo , Estudos de Coortes , Combinação de Medicamentos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Estudos Prospectivos , Síndromes da Apneia do Sono/tratamento farmacológico , Síndromes da Apneia do Sono/epidemiologia , Volume Sistólico , Valsartana , Função Ventricular Esquerda
12.
BMJ Open ; 11(5): e044499, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33972338

RESUMO

INTRODUCTION: To date, continuous positive airway pressure (CPAP) remains the cornerstone of obstructive sleep apnoea treatment. CPAP data describing residual sleep-disordered breathing events (ie, the CPAP-measured apnoea-hypopnoea indices (AHI-CPAPflow)) is difficult to interpret because it is an entirely different metric than the polysomnography (PSG) measured AHI gold standard (AHI-PSGgold). Moreover, manufacturer definitions for apnoea and hypopnoea are not only different from those recommended for PSG scoring, but also different between manufacturers. In the context of CPAP initiation and widespread telemedicine at home to facilitate sleep apnoea care, there is a need for concrete evidence that AHI-CPAPflow can be used as a surrogate for AHI-PSGgold. METHODS AND ANALYSIS: No published systematic review and meta-analysis (SRMA) has compared the accuracy of AHI-CPAPflow against AHI-PSGgold and the primary objective of this study is therefore to do so using published data. The secondary objectives are to similarly evaluate other sleep disordered breathing indices and to perform subgroup analyses focusing on the inclusion/exclusion of central apnoea patients, body mass index levels, CPAP device brands, pressure titration modes, use of a predetermined and fixed pressure level or not, and the impact of a 4% PSG desaturation criteria versus 3% PSG on accuracy. The Preferred Reporting Items for SRMA protocols statement guided study design. Randomised controlled trials and observational studies of adult patients (≥18 years old) treated by a CPAP device will be included. The CPAP intervention and PSG comparator must be performed synchronously. PSGs must be scored manually and follow the American Academy of Sleep Medicine guidelines (2007 AASM criteria or more recent). To assess the risk of bias in each study, the Quality Assessment of Diagnostic Accuracy Studies 2 tool will be used. ETHICS AND DISSEMINATION: This protocol received ethics committee approval on 16 July 2020 (IRB_MTP_2020_07_2020000404) and results will be disseminated via peer-reviewed publications. PROSPERO/TRIAL REGISTRATION NUMBERS: CRD42020159914/NCT04526366; Pre-results.


Assuntos
Apneia Obstrutiva do Sono , Telemedicina , Adolescente , Adulto , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Metanálise como Assunto , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Revisões Sistemáticas como Assunto
13.
Respir Res ; 22(1): 79, 2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33691702

RESUMO

BACKGROUND: Pulmonary rehabilitation (PR) improves exercise capacity, health-related quality of life (HRQoL) and dyspnea in chronic obstructive pulmonary disease (COPD) patients. Maintenance programs can sustain the benefits for 12 to 24 months. Yet, the long-term effects (> 12 months) of pragmatic maintenance programs in real-life settings remain unknown. This prospective cohort study assessed the yearly evolution in the outcomes [6-min walking distance (6MWD), HRQoL, dyspnea] of a supervised self-help PR maintenance program for COPD patients followed for 5 years. The aim was to assess the change in the outcomes and survival probability for 1 to 5 years after PR program discharge in COPD patients following a PR maintenance program supported by supervised self-help associations. METHODS: Data were prospectively collected from 144 COPD patients who followed a pragmatic multidisciplinary PR maintenance program for 1 to 5 years. They were assessed yearly for 6MWD, HRQol (VQ11) and dyspnea (MRC). The 5-year survival probability was compared to that of a control PR group without a maintenance program. A trajectory-based cluster analysis identified the determinants of long-term response. RESULTS: Maintenance program patients showed significant PR benefits at 4 years for 6MWD and VQ11 and 5 years for MRC. The 5-year survival probability was higher than for PR patients without PR maintenance. Two clusters of response to long-term PR were identified, with responders being the less severe COPD patients. CONCLUSIONS: This study provides evidence of the efficacy of a pragmatic PR maintenance program in a real-life setting for more than 3 years. In contrast to short-term PR, long-term PR maintenance appeared more beneficial in less severe COPD patients.


Assuntos
Bases de Dados Factuais/tendências , Terapia por Exercício/métodos , Terapia por Exercício/tendências , Tolerância ao Exercício/fisiologia , Doença Pulmonar Obstrutiva Crônica/reabilitação , Idoso , Estudos de Coortes , Terapia por Exercício/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/mortalidade , Taxa de Sobrevida/tendências , Fatores de Tempo
14.
Respir Res ; 22(1): 17, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33451313

RESUMO

BACKGROUND: For some patients, Continuous Positive Airway Pressure (CPAP) remains an uncomfortable therapy despite the constant development of technological innovations. To date, no real life study has investigated the relationship between mask related side-effects (MRSEs) and CPAP-non-adherence (defined as < 4 h/day) or residual-excessive-sleepiness (RES, Epworth-Sleepiness-Scale (ESS) score ≥ 11) in the long-term. METHODS: The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks). MRSEs were evaluated using visual-analogue-scales, CPAP-data using CPAP-software, sleepiness using ESS. RESULTS: 1484 patients were included in the analysis (72.2% male, median age 67 years (IQ25-75: 60-74), initial Apnea-Hypopnea-Index (AHI) of 39 (31-56)/h, residual AHIflow was 1.9 (0.9-4) events/h), CPAP-treatment lasted 4.4 (2.0-9.7) years, CPAP-usage was 6.8 (5.5-7.8) h/day, the prevalence of CPAP-non-adherence was 8.6%, and the prevalence of RES was 16.17%. Leak-related side-effects were the most prevalent side-effects (patient-reported leaks concerned 75.4% of responders and had no correlation with CPAP-reported-leaks). Multivariable logistic regression analyses evaluating explanatory-variable (demographic data, device/mask data and MRSEs) effects on variables-of-interest (CPAP-non-adherence and RES), indicated for patient-MRSEs significant associations between: (i) CPAP-non-adherence and dry-mouth (p = 0.004); (ii) RES and patient-reported leaks (p = 0.007), noisy mask (p < 0.001), dry nose (p < 0.001) and harness pain (p = 0.043). CONCLUSION: In long-term CPAP-treated patients, leak-related side-effects remain the most prevalent side-effects, but patient-reported leaks cannot be predicted by CPAP-reported-leaks. Patient-MRSEs can be independently associated with CPAP-non-adherence and RES, thus implying a complementary role for MRSE questionnaires alongside CPAP-device-reported-data for patient monitoring. Trial registration InterfaceVent is registered with ClinicalTrials.gov (NCT03013283).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/tendências , Apneia Obstrutiva do Sono/terapia , Sonolência , Idoso , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/fisiopatologia
15.
J Asthma ; 58(7): 946-957, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32285714

RESUMO

OBJECTIVE: Oral corticosteroids (OCS) are frequently used as relievers for acute asthma and controllers for severe asthma. However, the relief offered by OCS is counterbalanced by adverse effects. We aimed to describe how patients perceive OCS treatment benefits and risks, and how this could affect their adherence to the treatment. METHODS: Patients aged ≥18 years with asthma registered with Carenity, an online patient community, were invited to respond to a questionnaire containing 35 closed and 3 open questions to assess their asthma and perceptions of OCS. RESULTS: 268/300 respondents were receiving or had received OCS for asthma (58 for long-term use and 107 for short-term use). The mean age at diagnosis was 21.3 years. 66% had uncontrolled asthma (GINA control score 3 or 4). Although 42% perceived OCS to be efficacious, 46% mentioned adverse effects. Respondents were mostly satisfied with OCS (median = 7.0/10), particularly for efficacy (median = 8.0/10). Respondents reported having strategies to avoid OCS, mainly because of adverse effects. 26% of respondents had previously reduced or stopped OCS; this proportion was 22% for short-term OCS users and 36% for long-term users. 15% of the respondents not receiving long-term OCS would take the treatment without doing anything else if long-term OCS were prescribed; 42% would seek an alternative treatment. CONCLUSIONS: OCS for asthma is perceived efficient but associated with adverse effects. Patients seek alternative treatment.


Assuntos
Corticosteroides/uso terapêutico , Antiasmáticos/uso terapêutico , Asma/tratamento farmacológico , Asma/psicologia , Percepção , Administração Oral , Corticosteroides/administração & dosagem , Corticosteroides/efeitos adversos , Adulto , Antiasmáticos/administração & dosagem , Antiasmáticos/efeitos adversos , Dieta , Feminino , França , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Comportamento de Busca de Informação , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
16.
Respir Res ; 21(1): 243, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32957983

RESUMO

BACKGROUNDS: To explain the excess cardiovascular mortality observed in the SERVE-HF study, it was hypothesized that the high-pressure ASV default settings used lead to inappropriate ventilation, cascading negative consequences (i.e. not only pro-arrythmogenic effects through metabolic/electrolyte abnormalities, but also lower cardiac output). The aims of this study are: i) to describe ASV-settings for long-term ASV-populations in real-life conditions; ii) to describe the associated minute-ventilations (MV) and therapeutic pressures for servo-controlled-flow versus servo-controlled-volume devices (ASV-F Philips®-devices versus ASV-V ResMed®-devices). METHODS: The OTRLASV-study is a cross-sectional, 5-centre study including patients who underwent ASV-treatment for at least 1 year. The eight participating clinicians were free to adjust ASV settings, which were compared among i) initial diagnosed sleep-disordered-breathing (SBD) groups (Obstructive-Sleep-Apnea (OSA), Central-Sleep-Apnea (CSA), Treatment-Emergent-Central-Sleep-Apnea (TECSA)), and ii) unsupervised groups (k-means clusters). To generate these clusters, baseline and follow-up variables were used (age, sex, body mass index (BMI), initial diagnosed Obstructive-Apnea-Index, initial diagnosed Central-Apnea-Index, Continuous-Positive-Airway-Pressure used before ASV treatment, presence of cardiopathy, and presence of a reduced left-ventricular-ejection-fraction (LVEF)). ASV-data were collected using the manufacturer's software for 6 months. RESULTS: One hundred seventy-seven patients (87.57% male) were analysed with a median (IQ25-75) initial Apnea-Hypopnea-Index of 50 (38-62)/h, an ASV-treatment duration of 2.88 (1.76-4.96) years, 61.58% treated with an ASV-V. SDB groups did not differ in ASV settings, MV or therapeutic pressures. In contrast, the five generated k-means clusters did (generally described as follows: (C1) male-TECSA-cardiopathy, (C2) male-mostly-CSA-cardiopathy, (C3) male-mostly-TECSA-no cardiopathy, (C4) female-mostly-elevated BMI-TECSA-cardiopathy, (C5) male-mostly-OSA-low-LVEF). Of note, the male-mostly-OSA-low-LVEF-cluster-5 had significantly lower fixed end-expiratory-airway-pressure (EPAP) settings versus C1 (p = 0.029) and C4 (p = 0.007). Auto-EPAP usage was higher in the male-mostly-TECSA-no cardiopathy-cluster-3 versus C1 (p = 0.006) and C2 (p < 0.001). MV differences between ASV-F (p = 0.002) and ASV-V (p < 0.001) were not homogenously distributed across clusters, suggesting specific cluster and ASV-algorithm interactions. Individual ASV-data suggest that the hyperventilation risk is not related to the cluster nor the ASV-monitoring type. CONCLUSIONS: Real-life ASV settings are associated with combinations of baseline and follow-up variables wherein cardiological variables remain clinically meaningful. At the patient level, a hyperventilation risk exists regardless of cluster or ASV-monitoring type, spotlighting a future role of MV-telemonitoring in the interest of patient-safety. TRIAL REGISTRATION: The OTRLASV study was registered on ClinicalTrials.gov (Identifier: NCT02429986 ). 1 April 2015.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/sangue , Apneia Obstrutiva do Sono/terapia , Volume de Ventilação Pulmonar/fisiologia , Idoso , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Ventilação Pulmonar/fisiologia , Respiração Artificial/métodos , Síndromes da Apneia do Sono/sangue , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Apneia Obstrutiva do Sono/diagnóstico
17.
BMC Med Ethics ; 21(1): 72, 2020 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-32791969

RESUMO

BACKGROUND: Patient skepticism concerning medical innovations can have major consequences for current public health and may threaten future progress, which greatly relies on clinical research. The primary objective of this study is to determine the variables associated with patient acceptation or refusal to participate in clinical research. Specifically, we sought to evaluate if distrust in pharmaceutical companies and associated psychosocial factors could represent a recruitment bias in clinical trials and thus threaten the applicability of their results. METHODS: This prospective, multicenter survey consisted in the administration of a self-questionnaire to patients during a pulmonology consultation. The 1025 questionnaires distributed collected demographics, socio-professional and basic health literacy characteristics. Patients were asked to rank their level of trust for pharmaceutical companies and indicate their willingness to participate in different categories of research (pre or post marketing, sponsored by an academic institution or pharmaceutical company). Logistic regression was used to determine factors contributing to "trust" versus "distrust" group membership and willingness to participate in each category of research. RESULTS: One thousand patients completed the survey, corresponding to a response rate of 97.5%. Data from 838 patients were analyzed in this study. 48.3% of respondents declared that they trusted pharmaceutical companies, while 35.5% declared distrust. Being female (p = 0.042), inactive in the employment market(p = 0.007), and not-knowing the name of one's disease(p = 0.010) are factors related to declared distrust. Distrust-group membership is associated with unwillingness to participate in certain categories of trials such as pre-marketing and industry-sponsored trials. CONCLUSION: Distrust in pharmaceutical companies is associated with a specific patient profile and with refusal to participate in certain subcategories of trials. This potential recruitment bias may explain the under-representation of certain categories of patients such as women in pre-marketing drug trials.


Assuntos
Preparações Farmacêuticas , Confiança , Altruísmo , Indústria Farmacêutica , Feminino , Humanos , Marketing , Estudos Prospectivos
18.
Chest ; 158(5): 2165-2171, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32544491

RESUMO

BACKGROUND: Unintentional leaks (ULs) are frequent adverse effects in CPAP-treated patients. We previously published a novel methodology for analyzing the determinants of UL using polysomnography. We now propose a simplified recording system using a type 3 polygraphic device (Somnolter; Nomics S.A.). RESEARCH QUESTION: (1) To describe individual UL determinants provided by the Somnolter software in automatic-CPAP-treated OSA patients; (2) To subsequently describe the clinical consensus of four physicians on how to manage each individual UL situation. STUDY DESIGN AND METHODS: Somnoler recordings performed under nasal automatic-CPAP were automatically analyzed with APIOS software. For each polygraphic recording, APIOS provided the OR and the CIs for potential determinants of UL: mouth opening, CPAP pressure, body position, and mandibular oscillation. Based on these results, each of four physicians was asked to choose one of four strategies: (1) increase or decrease therapeutic pressure; (2) change nasal mask for oro-nasal mask/chinstrap; (3) favor a nonsupine or supine position; (4) no action for individual leak management. Subsequently, a meeting was held to determine a consensus choice for each individual case. RESULTS: Seventy-eight consecutive patients underwent home-polygraphy with Somnolter. Fifty recordings were analyzed (16 females; 65 [57-75] years of age; BMI = 31.1 [27.4-35.3]). Individual diagnosis of UL was routinely feasible. The determinants of UL were heterogeneous in the population, and diagnosis of UL was not feasible in 10 patients. Based on the results from this analysis, we established consensus leak management strategies at the individual level. The average Cohen κ coefficient for the four raters was 0.58. Pressure modification was proposed in 36% of patients, no action in 24%, installation of a facial mask/chinstrap in 22%, and positional treatment in 18%. INTERPRETATION: The use of type 3 polygraphy for characterizing leak determinants in patients treated with nasal automatic-CPAP is feasible in routine practice. Leak determinants are patient specific. Interrater concordance for determining individual leak management strategies demonstrated a "fair" level of agreement. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT03381508; URL: www.clinicaltrials.gov).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Máscaras/efeitos adversos , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Idoso , Falha de Equipamento , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia
19.
Respir Res ; 20(1): 235, 2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31665026

RESUMO

BACKGROUNDS: As a consequence of the increased mortality observed in the SERVE-HF study, many questions concerning the safety and rational use of ASV in other indications emerged. The aim of this study was to describe the clinical characteristics of ASV-treated patients in real-life conditions. METHODS: The OTRLASV-study is a prospective, 5-centre study including patients who underwent ASV-treatment for at least 1 year. Patients were consecutively included in the study during the annual visit imposed for ASV-reimbursement renewal. RESULTS: 177/214 patients were analysed (87.57% male) with a median (IQ25-75) age of 71 (65-77) years, an ASV-treatment duration of 2.88 (1.76-4.96) years, an ASV-usage of 6.52 (5.13-7.65) hours/day, and 54.8% were previously treated via continuous positive airway pressure (CPAP). The median Epworth Scale Score decreased from 10 (6-13.5) to 6 (3-9) (p < 0.001) with ASV-therapy, the apnea-hypopnea-index decreased from 50 (38-62)/h to a residual device index of 1.9 (0.7-3.8)/h (p < 0.001). The majority of patients were classified in a Central-Sleep-Apnea group (CSA; 59.3%), whereas the remaining are divided into an Obstructive-Sleep-Apnea group (OSA; 20.3%) and a Treatment-Emergent-Central-Sleep-Apnea group (TECSA; 20.3%). The Left Ventricular Ejection Fraction (LVEF) was > 45% in 92.7% of patients. Associated comorbidities/etiologies were cardiac in nature for 75.7% of patients (neurological for 12.4%, renal for 4.5%, opioid-treatment for 3.4%). 9.6% had idiopathic central-sleep-apnea. 6.2% of the patients were hospitalized the year preceding the study for cardiological reasons. In the 6 months preceding inclusion, night monitoring (i.e. polygraphy or oximetry during ASV usage) was performed in 34.4% of patients, 25.9% of whom required a subsequent setting change. According to multivariable, logistic regression, the variables that were independently associated with poor adherence (ASV-usage ≤4 h in duration) were TECSA group versus CSA group (p = 0.010), a higher Epworth score (p = 0.019) and lack of a night monitoring in the last 6 months (p < 0.05). CONCLUSIONS: In real-life conditions, ASV-treatment is often associated with high cardiac comorbidities and high compliance. Future research should assess how regular night monitoring may optimize devices settings and patient management. TRIAL REGISTRATION: The OTRLASV study is registered on ClinicalTrials.gov (Identifier: NCT02429986 ) on 1 April 2015.


Assuntos
Respiração Artificial/métodos , Apneia do Sono Tipo Central/diagnóstico , Apneia do Sono Tipo Central/terapia , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Estudos Prospectivos , Apneia do Sono Tipo Central/sangue , Apneia Obstrutiva do Sono/sangue
20.
Respir Res ; 20(1): 209, 2019 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-31514751

RESUMO

BACKGROUND: Whereas telemedicine usage is growing, the only clinical algorithm for Continuous Positive Airway Pressure (CPAP) adherence management is that stipulated by the 2013 American Thoracic Society (ATS). The capacity of the latter to predict non-adherence in long-term CPAP-treated patients has not been validated. METHODS: Patients from the prospective real-life InterfaceVent study (NCT03013283, study conducted in an adult cohort undergoing at least 3 months of CPAP) and eligible for ATS algorithm usage were analysed. The residual device Apnea-Hypopnea-Index (AHIflow) and High Large Leak (HLL) thresholds proposed in the ATS algorithm were evaluated for predicting adherence (i.e. AHIflow > 10/h, HLLs 95th > 24 L/min for ResMed® devices and ResMed® nasal mask, HLLs 95th > 36 l/min for ResMed® devices and ResMed® oronasal masks, HLLs > 1 h for Philips® devices and HHLs > 60 l/min for Fisher & Paykel® devices). Adherence was defined according to the 2013 ATS algorithm (i.e. CPAP use > 4 h/j for at least 70% of days). RESULTS: 650/1484 patients eligible for ATS algorithm usage were analysed (15.38% non-adherent, 74% male with a median (IQ25-75) age of 68 (61-77) years, a body mass index of 30.8 (27.7-34.5) kg/m2, an initial AHI of 39 (31-55) events/h, and CPAP-treatment-duration of 5.1 (2.2-7.8) years). Logistic regression analysis demonstrated no significant relationship between the ATS proposed AHIflow or HLL thresholds and non-adherence. Complementary ROC curve analysis failed to determine satisfactory AHIflow and HLL thresholds. CONCLUSION: When managing non-adherence in long-term CPAP-treated patients, our data do not validate absolute AHIflow or HLL thresholds in general. TRIAL REGISTRATION: The INTERFACE-VENT study is registered on ClinicalTrials.gov (Identifier: study ( NCT03013283 ).


Assuntos
Algoritmos , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Cooperação do Paciente/estatística & dados numéricos , Adulto , Idoso , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , Masculino , Máscaras , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Telemedicina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...