Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
2.
Microsc Res Tech ; 87(1): 172-178, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37732407

RESUMO

AIM: This study aimed to use the micro-computed tomography to evaluate the interfacial adaptation and the presence of gaps of NeoMTA Plus, BioRoot RCS, and MTA in the root-end cavities. METHODOLOGY: Thirty standardized bovine roots measuring 15 mm in length were selected. Chemical-mechanical preparation was performed up to instrument #80 and obturation with the cold lateral compaction technique with cement based on zinc oxide and eugenol. The roots were kept at 37°C for 7 days. Afterward, apicectomy of the apical 3 mm and a root-end filling cavity was performed at 3 mm depth. Micro-computed tomography (micro-CT) was performed to measure the volume of the retroactivity. The roots were divided by stratified randomization into three groups according to the retro-end filling material: NeoMTA Plus, BioRoot RCS, and MTA. A new micro-CT was performed to assess the presence of voids in the root-end filling material and between it and the canal wall. One-way ANOVA and Tukey tests were performed using the BioEstat 4.0 program. RESULTS: There was no difference in the initial volume values of the root-end cavities (p > .05). After the insertion of root-end filling materials, the most significant volumes of voids were observed in the NeoMTA Plus group (p < .05), with no difference for the BioRoot RCS and MTA Angelus groups (p > .05). CONCLUSION: Micro-computed tomography showed that MTA and BioRoot RCS have better interfacial adaptation and presented fewer number of gaps than NeoMTA Plus when used as root-end filling materials. RESEARCH HIGHLIGHTS: Micro-computed tomography evaluation of different root-end fillings materials.


Assuntos
Materiais Restauradores do Canal Radicular , Animais , Bovinos , Microtomografia por Raio-X/métodos , Compostos de Cálcio , Guta-Percha , Obturação do Canal Radicular , Silicatos , Cavidade Pulpar
3.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557212

RESUMO

Abstract This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Resumo Este estudo avaliou o efeito de um novo método para aplicação do sistema adesivo na resistência de união entre pino de fibra e dentina radicular usando dois sistemas adesivos. Os canais de sessenta incisivos bovinos foram preparados e obturados. As raízes foram divididas em seis grupos (n=10) de acordo com o sistema adesivo (Clearfil SE - CSE e Single Bond Universal - SBU) e com a estratégia de aplicação (microbrush - MB, escova rotatória - RB e inserto ultrassônico - US). Os pinos de fibra foram cimentados utilizando cimento resinoso (RelyX ARC). As raízes foram seccionadas perpendicularmente ao seu longo eixo e três fatias foram obtidas. Previamente ao teste de push-out, foi realizada microscopia de varredura confocal a laser para ilustrar a adaptação interfacial do cimento às paredes do canal radicular. Os padrões de falha foram analisados com magnificação de 40x. O teste de Shapiro-Wilk indicou distribuição normal dos dados. Os valores de resistência de união foram comparados usando o teste ANOVA de uma via e post hoc de Tukey. As diferenças entre os sistemas adesivos em cada terço e de acordo com cada protocolo foram analisadas pelo teste T de Student. O nível de significância foi de 5%. CSE aplicado com RB apresentou maiores valores médios de resistência de união do que quando aplicado com MB (técnica convencional) (P<0,05). Aplicação com US apresentou valores intermediários de resistência de união para o CSE (P>0,05). A aplicação do SBU utilizando RB gerou maiores valores médios de resistência de união comparados com MB e US (P<0,05). Falhas adesivas foram predominantes (65,5%). A aplicação do CSE e SBU com a nova escova rotatória melhorou a resistência de união dos pinos de fibra à dentina radicular comparados com a estratégia convencional.

4.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513030

RESUMO

This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) - Bio-C Temp and Ultracal - after different activation protocols in teeth with simulated internal root resorption. Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05). There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05). Due to this, it can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption.

5.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513031

RESUMO

Aims: This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) -Bio-C Temp and Ultracal -after different activation protocols in teeth with simulated internal root resorption.Materials and methods: Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05).Results:There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05).Conclusion:It can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption.

6.
J. res. dent ; 11(1): 14-19, May 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513032

RESUMO

Aims: This study aims to evaluate, by micro-computed tomography, the filling capacity of two root canal dressings (RCD) -Bio-C Temp and Ultracal -after different activation protocols in teeth with simulated internal root resorption.Materials and methods: Eighty single-rooted bovine teeth were sectioned in the cervical portion, standardizing the roots at 16 mm. Then, the canals were prepared by the apex-crown technique until instrument #80 using 2mL of 2.5% sodium hypochlorite solution at each instrument change. Afterward, the roots were sectioned longitudinally, and internal root resorptions were simulated using a diamond bur 1016 at 5 mm from the root apex. Hemiroots were joined and fixed with cyanoacrylate, scanned in micro-computed tomography (micro-CT) to assess total canal volume and simulated internal resorption, and then divided by stratified randomization into experimental groups according to RCD and method of activation (n = 10): Ultracal/Syringe; Ultracal/PUI, Ultracal/XP Endo Finisher, Ultracal Easy Clean, Bio-C Temp/Syringe, Bio-C Temp/PUI, Bio-C Temp/XP Endo Finisher and Bio-C/Easy Clean. Another scanning was performed to assess the volume of voids after RCD activation methods. The ANOVA and Tukey tests compared the activation methods. Student's T-test compared the RCDs within each activation method. Initial root canal volume values were similar for all groups (P > 0.05).Results:There was no difference between activation protocols (P > 0.05). Higher volumes of void spaces were observed for Bio-C Temp compared to Ultracal after all activation methods (P < 0.05), except for Easy Clean (P > 0.05).Conclusion:It can be concluded that the agitation methods tested for the Bio-C Temp and Ultracal pastes did not improve the filling of bovine teeth with simulated internal root resorption

7.
Restor Dent Endod ; 47(4): e40, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36518607

RESUMO

Objectives: This study aimed to investigate the influence of different obturation techniques compared to cold lateral compaction on the success rate of primary non-surgical endodontic treatments. Materials and Methods: Systematic searches were performed for studies published up to May 17th, 2022 in MEDLINE/PubMed, Cochrane Library, Web of Science, Scopus, EMBASE, and Grey Literature Reports. Randomized clinical trials and nonrandomized (nonrandomized clinical trials, prospective or retrospective) studies that evaluated the success rate of primary non-surgical endodontic treatments obturated with the cold lateral compaction (control) and other obturation techniques were included. The revised Cochrane risk of bias tools for randomized trials (RoB 2) and nonrandomized studies of interventions (ROBINS-I) were used to evaluate the risk of bias. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) tool was used to evaluate the certainty of evidence. Results: Eleven studies (4 randomized clinical trials (RCTs), 4 prospective, and 3 retrospectives) were included. Two RCTs were classified as having some concerns risk of bias and 2 as a low risk of bias. Two nonrandomized studies were classified as having a critical risk of bias and 5 as having a moderate risk of bias. The GRADE analysis demonstrated a very low to moderate certainty of evidence. Conclusions: This systematic review generally evidenced no differences in the success rate of primary non-surgical endodontic treatments when the cold lateral compaction technique and other obturation techniques are performed. Further well-designed studies are still necessary.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA