Front Cardiovasc Med ; 10: 1160242, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37363094

RESUMO

Background: Smartwatches are commonly capable to record a lead-I-like electrocardiogram (ECG) and perform a photoplethysmography (PPG)-based atrial fibrillation (AF) detection. Wearable technologies repeatedly face the challenge of frequent premature beats, particularly in target populations for screening of AF. Objective: To investigate the potential diagnostic benefit of six-lead ECG compared to single-lead ECG and PPG-based algorithm for AF detection of the wrist-worn device. Methods and results: From the database of DoubleCheck-AF 249 adults were enrolled in AF group (n = 121) or control group of SR with frequent premature ventricular (PVCs) or atrial (PACs) contractions (n = 128). Cardiac rhythm was monitored using a wrist-worn device capable of recording continuous PPG and simultaneous intermittent six-lead standard-limb-like ECG. To display a single-lead ECG, the six-lead ECGs were trimmed to lead-I-like ECGs. Two diagnosis-blinded cardiologists evaluated reference, six-lead and single-lead ECGs as "AF", "SR", or "Cannot be concluded". AF detection based on six-lead ECG, single-lead ECG, and PPG yielded a sensitivity of 99.2%, 95.7%, and 94.2%, respectively. The higher number of premature beats per minute was associated with false positive outcomes of single-lead ECG (18.80 vs. 5.40 beats/min, P < 0.01), six-lead ECG (64.3 vs. 5.8 beats/min, P = 0.018), and PPG-based detector (13.20 vs. 5.60 beats/min, P = 0.05). Single-lead ECG required 3.4 times fewer extrasystoles than six-lead ECG to result in a false positive outcome. In a control subgroup of PACs, the specificity of six-lead ECG, single-lead ECG, and PPG dropped to 95%, 83.8%, and 90%, respectively. The diagnostic value of single-lead ECG (AUC 0.898) was inferior to six-lead ECG (AUC 0.971) and PPG-based detector (AUC 0.921). In a control subgroup of PVCs, the specificity of six-lead ECG, single-lead ECG, and PPG was 100%, 96.4%, and 96.6%, respectively. The diagnostic value of single-lead ECG (AUC 0.961) was inferior to six-lead ECG (AUC 0.996) and non-inferior to PPG-based detector (AUC 0.954). Conclusions: A six-lead wearable-recorded ECG demonstrated the superior diagnostic value of AF detection compared to a single-lead ECG and PPG-based AF detection. The risk of type I error due to the widespread use of smartwatch-enabled single-lead ECGs in populations with frequent premature beats is significant.

2.
Front Cardiovasc Med ; 9: 869730, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35463751

RESUMO

Background: Consumer smartwatches have gained attention as mobile health (mHealth) tools able to detect atrial fibrillation (AF) using photoplethysmography (PPG) or a short strip of electrocardiogram (ECG). PPG has limited accuracy due to the movement artifacts, whereas ECG cannot be used continuously, is usually displayed as a single-lead signal and is limited in asymptomatic cases. Objective: DoubleCheck-AF is a validation study of a wrist-worn device dedicated to providing both continuous PPG-based rhythm monitoring and instant 6-lead ECG with no wires. We evaluated its ability to differentiate between AF and sinus rhythm (SR) with particular emphasis on the challenge of frequent premature beats. Methods and Results: We performed a prospective, non-randomized study of 344 participants including 121 patients in AF. To challenge the specificity of the device two control groups were selected: 95 patients in stable SR and 128 patients in SR with frequent premature ventricular or atrial contractions (PVCs/PACs). All ECG tracings were labeled by two independent diagnosis-blinded cardiologists as "AF," "SR" or "Cannot be concluded." In case of disagreement, a third cardiologist was consulted. A simultaneously recorded ECG of Holter monitor served as a reference. It revealed a high burden of ectopy in the corresponding control group: 6.2 PVCs/PACs per minute, bigeminy/trigeminy episodes in 24.2% (31/128) and runs of ≥3 beats in 9.4% (12/128) of patients. AF detection with PPG-based algorithm, ECG of the wearable and combination of both yielded sensitivity and specificity of 94.2 and 96.9%; 99.2 and 99.1%; 94.2 and 99.6%, respectively. All seven false-positive PPG-based cases were from the frequent PVCs/PACs group compared to none from the stable SR group (P < 0.001). In the majority of these cases (6/7) cardiologists were able to correct the diagnosis to SR with the help of the ECG of the device (P = 0.012). Conclusions: This is the first wearable combining PPG-based AF detection algorithm for screening of AF together with an instant 6-lead ECG with no wires for manual rhythm confirmation. The system maintained high specificity despite a remarkable amount of frequent single or multiple premature contractions.

3.
J Electrocardiol ; 68: 157-163, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34455115

RESUMO

BACKGROUND: ST/T abnormalities recognized as electrocardiographic (ECG) left ventricular (LV) strain pattern are known as a marker of myocyte death and reduced survival. The purpose of this study was to determine whether ECG LV strain pattern, its components and atrial fibrillation (AF) predict lower survival at the time of diagnosis of systemic light chain (AL) amyloidosis. METHODS: 12­lead surface electrocardiogram (ECG), standard two-dimensional echocardiography, laboratory analyses were retrospectively evaluated within 2 months of diagnosis in 87 patients with biopsy-proven systemic AL amyloidosis from 2009 to 2017 in a single center. ECG strain pattern was defined as coexistence of ST-segment horizontal or downward sloping depression ≥0.05 mV at its most horizontal section and negative asymmetrical T-wave deeper than 0.1 mV in at least 1 of leads I,aVL,V1-V6. Patients with QRS >120 ms (BBB or major IVCD) were excluded from the analysis. RESULTS: Kaplan-Meier survival analysis revealed a 1.8-fold shorter overall survival (OS) at 2 years in the ECG strain (21% of participants) group (p = 0.0078), 2.0-fold shorter OS in the ST-segment depression (STd) (isolated and strain related as one group) (34% of participants) group (p < 0.0001), and 3.9-fold shorter OS in AF (23% of participants) group (p < 0.0001) compared with those without. Median survival of patients with STd and AF were and 13.0 (range 1-74) and 9.5 (range 1-74) months respectively. In univariate analysis STd and AF were stronger predictors of inferior OS than relative wall thickness, average E/e' ratio, and LV ejection fraction, but weaker predictors of OS than B-type natriuretic peptide. In multivariate analysis STd and AF lost significance after adjustment for age, gender, number of organs involved and BNP. CONCLUSIONS: ST-segment depression and AF were not significantly associated with reduced survival in AL amyloidosis at diagnosis.


Assuntos
Amiloidose , Fibrilação Atrial , Amiloidose de Cadeia Leve de Imunoglobulina , Amiloidose/diagnóstico , Amiloidose/epidemiologia , Fibrilação Atrial/diagnóstico , Depressão , Eletrocardiografia , Humanos , Incidência , Estudos Retrospectivos